Back to Authors

Karon, Barry L.

Mayo Clinic

Mayo Clinic

Citations 8

A-301 Evaluation of Second-Generation Visby Medical Sexual Health Point-of-Care Test: Clinical Concordance, Analytical Error Rates, and Result Turnaround Time
Kelley, Barbara R, Wockenfus, Amy M., Binnicker, Matthew J. , Karon, Barry L., Kelley, B, Donato, Leslie J.

Clinical Chemistry | October 2, 2024 | Volume: 70 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvae106.298 Get It

Abstract Background Rapid testing for Neisseria gonorrhoeae, Chlamydia trachomatis, and Trichomonas vaginalis may be useful for antibiotic stewardship initiatives. Our institution recently implemented the second-generation Visby Medical Sexual Health Test (Visby Gen2) for rapid diagnosis of STIs in our emergency department. Here we (1) compared result concordance of the (Visby Gen2) to the first-generation Visby Medical Sexual Health Click Test (Visby Gen1), (2) compared assay failure rates of the Visby Gen1 to Gen2 tests, and (3) compared result turnaround time (TAT) for clinically ordered rapid STI tests to central laboratory STI results. Methods Accuracy was assessed using residual clinical samples in Aptima buffer submitted for routine molecular STI testing (C. trachomatis, N. gonorrhoeae, and T. vaginalis) in the central laboratory on the Panther platform (Hologic). Aptima samples were diluted 1:33 in Visby collection buffer prior to testing on the Visby cartridge. Clinically reported results were used as reference results. Diluted samples with discordant results were re-tested on the reference method and the result from the dilution was used in calculations. Assay failure rates were calculated as the number of failed assays compared to the total assays performed. TAT for rapid and central lab testing was calculated as time of sample received in laboratory to time verified in laboratory information system. Results For Visby Gen1 we observed negative concordance of 100% (41/41) for C. trachomatis, 97.5% (39/40) for N. gonorrhoeae, and 97.1% (34/35) for T. vaginalis. Positive concordance was 91.7% (11/12) for C. trachomatis, 100% (11/11) for N. gonorrhoeae, and 100% (17/17) for T. vaginalis. For Visby Gen1 we observed a 10.5% (12/114) cartridge failure rate. For Visby Gen2, we observed negative concordance of 100% (59/59) for C. trachomatis, 100% (63/63) for N. gonorrhoeae, and 100% (55/55) for T. vaginalis while positive concordance was 100% (10/10) for C. trachomatis, 100% (6/6) for N. gonorrhoeae, and 90.9% (10/11) for T. vaginalis. The Visby Gen2 assay displayed a 4.9% (4/81) cartridge failure rate. Six weeks after implementing the Visby Gen2 assay in our ED, rapid STI panel TAT was 0.48 hours on average (n=20). In the central laboratory the average TAT was 22.31 hours (n=7892). Conclusions Assay concordance to reference method was similar for Visby Gen1 and Gen2 assays. The cartridge failure rate improved by 46.7% with the Gen2 assay which should decrease the need to repeat testing due to assay failure. Result TAT decreased by 97.8% when comparing rapid Visby results to central laboratory. Therefore, Visby STI testing using the Gen2 assay can provide accuracy and rapid results likely to facilitate more rapid patient management.
Abstract 18738: Pulmonary Artery Systolic Pressures Increase With Aging: A Longitudinal, Population Based Study
Chandra, Suparna, Redfield, Margaret M. , Karon, Barry L., Rodeheffer, Richard J. , Kane, Garvan C.

Circulation | April 23, 2024 | Volume: 128 | Issue: suppl_22 | Pages: No page available

10.1161/circ.128.suppl_22.a18738 Get It

Background: A community based, cross-sectional echo survey demonstrated that pulmonary artery systolic pressure (PASP) increases with age and that PASP is associated with systemic arterial stiffness, Doppler estimated left ventricular (LV) filling pressures and lung function. Longitudinal assessment of PASP is needed to confirm cross-sectional observations. Objectives: To assess the whether PASP changes over time in longitudinally studied subjects and determine whether changes in PASP are associated with changes in systemic vascular stiffness, LV filling pressures or lung function. Methods: A random sample (n=2042) of the Olmsted County, MN population over age 40 underwent echo, record review and spirometry between 1997-2000 (Exam 1). A subset (n=1402) underwent repeat studies four years later (2001-2004; Exam 2). The current analysis includes the 723 subjects with paired PASP measurements. Changes ([[Unable to Display Character: ▵]]) in PASP, systemic arterial stiffness (pulse pressure; PP), LV filling pressure (E/e’) and lung function (% age/sex expected forced expiratory volume, %FEV1) were assessed. Results: At Exam 1, the median (interquartile range) age was 62 (69-70) years (62% female). Median time between exams was 48 (47-49) months. PASP increased from 26.1 (24.4-30.0) mmHg at Exam 1 to 28.0 (24.4-32.0) mmHg at Exam 2 (p<0.0001 by paired t test) for an average (SD) [[Unable to Display Character: ▵]] of 1.2 ± 5.5 mmHg. Adjusting for age and PASP at Exam 1, [[Unable to Display Character: ▵]]PASP was associated with [[Unable to Display Character: ▵]] age with an increase (parameter estimate (pe) ± standard error (se)) of 1.4±0.7 mmHg per year increase in age (p=0.046). [[Unable to Display Character: ▵]]PASP was not associated with sex and there was no age-sex interaction. Adjusting for age and PASP at Exam 1, [[Unable to Display Character: ▵]] age and Exam 1 values for PP, E/e or %FEV1 as appropriate, [[Unable to Display Character: ▵]]PASP was associated with [[Unable to Display Character: ▵]] PP (pe±se = 0.03±0.01 mmHg; p=0.01) [[Unable to Display Character: ▵]]E/e’ (pe±se = 0.21±0.06 mmHg, p=0.001) and [[Unable to Display Character: ▵]]%FEV1 (-0.09±0.02 mmHg, p<0.0001) suggesting that increases in PASP were related to increases in vascular stiffening, increases in LV filling pressures and declining lung function. Conclusions: In this longitudinal, population based study we find that PASP increases with aging and that increases in PASP over time are related to increases in systemic vascular stiffness and LV filling pressures and decreases in lung function.
A-373 Comparison of the CoaguChek ® and Coag-Sense ® PT2 Meter Point of Care INR Devices
Schumann, Thomas L. , Karon, Barry L., O’Connor, Clare , Jennifer, L, Blanco, J, Hartman, Lisa L.R., Uy, J. , Myhre, Nikki K., GAYLE, DAVID D., Hartung, K, David, H., Santrach, Paula J., O'Connor, C, Jennifer, L, Kramer, A, Hartung, K, David, H, McBane, Robert D.

Clinical Chemistry | September 27, 2023 | Volume: 69 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvad097.329 Get It

Abstract Background Warfarin monitoring may be done at the point-of-care (POC) at home, in a clinic environment, or be performed using plasma specimens in a central laboratory. With a goal of standardizing International Normalization Ratio (INR) measurements and improving data integrity by enabling electronic transmission of results from any location, we evaluated two POC INR devices against an internal plasma INR reference method. Methods We conducted a multicenter study to test the accuracy of two commercially available point of care devices: Coag-Sense PT2 Meter (Coagusense, Inc., Fremont, CA) and CoaguChek XS Pro or XS Plus (Roche Diagnostics, Indianapolis, IN) compared with plasma INR values among warfarin treated patients. Bias and linear regression analysis were assessed for device-plasma INR comparisons. Warfarin dosing decisions were assessed for each device compared to an internal plasma INR reference method (Instrumentation Laboratories ACLTOP 500, 550, 750 analyzers (Werfen Diagnostics, Bedford MA) in one of three CLIA-certified laboratories. The thromboplastin used at our institution for INR measures is HemosIL RecombiPlasTin 2G (R2G) reagent (Werfen Diagnostics, Bedford MA) which has an International Sensitivity Index (ISI) of 1.0. Results Two hundred ninety-nine warfarin patients treated across three Mayo Clinic sites agreed to participate in the study. Common anticoagulant indications were atrial fibrillation (63.9%), venous thromboembolism (21.7%) and heart valve prosthesis (15.4%) with a 2.0–3.0 INR target range for 93.6% of patients. For the CoaguChek devices, 81.3% of values fell within 0.2 INR units of plasma INR referent and 95.3% within 0.4 units. The correlation between CoaguChek whole blood and plasma INR was excellent (R2 = 0.93). For the Coag-Sense device, 34.1% of values fell within 0.2 INR units and 60.2% within 0.4 INR units of plasma INR values, with a slightly weaker correlation between Coag-Sense whole blood and plasma INR (R2 = 0.83; P &lt; 0.0001). Mean (± standard deviation) deviation from plasma INR was 0.04 ± 0.2 for CoaguChek compared to 0.4 ± 0.3 for Coag-Sense (P &lt; 0.0001). The difference between POC devices was largely attributed to systematic negative bias between Coag-Sense and ACL TOP plasma INR values. Using the plasma INR as the reference method for dosing decision making, appropriate dosing recommendations would have occurred for 97.7% of CoaguChek and 81.6% of Coag-Sense results. Conclusion Compared to our institution's plasma reference method, INR values obtained from the CoaguChek devices (XS Pro and XS Plus) exhibited less systematic bias compared to the Coag-Sense values. This translates to greater percentage of concordant management decisions between POC and laboratory plasma INR methods when the CoaguChek device is used.
Abstract 19760: Longitudinal Changes in Cardiac Structure and Function After Creation of Dialysis Access in People With End Stage Kidney Disease: A 15 Year Experience
Dean, Patrick G. , Nath, Karl A. , Karon, Barry L., Reddy, Yogesh N.V. , Borlaug, Barry A.

Circulation | March 19, 2022 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.19760 Get It

Introduction: Arteriovenous fistulas(AVF) have been associated with high output heart failure but little is known about their effect on patients initiating hemodialysis. We sought to describe echocardiographic changes and identify those with incident heart failure after AVF creation. Methods: This was a retrospective analysis of all patients undergoing AVF creation over a 15 year period from 2000-2014 at the Mayo Clinic in Rochester, MN. Patients undergoing echocardiogram <3 months (median 40 days) before AVF creation and >6 months (median 2.5 years) following surgery were included. Patients with independent modifiers of LV structural changes (such as revascularization or myocardial infarction) were excluded by chart review. Clinical heart failure was defined by Framingham criteria. Results: From 2000-2014, 2236 patients underwent creation of AVFs and 137 patients met inclusion criteria. There was a longitudinal decrease in systolic function as evident by a drop in ejection fraction(-2%, p=0.047) with decrease in s’ tissue Doppler velocity(-0.6 cm/s, p=0.055) and increase in HR(+5 beats/min, p=0.003). There was also an increase in the prevalence of RV dilation(20 to 40%, p=0.002) and RV dysfunction(12 to 29%, p=0.002). With initiation of dialysis and decrease in weight (-7.3kg) and estimated plasma volume (-303ml) (both p<0.0001), there was a decrease in LV end diastolic dimension (-2mm, p=0.006). Despite better volume control, left atrial volume index increased (+5ml/m2, p=0.004). On multivariate Cox regression, worsening RV dilation [HR 1.8 (1.06-3.09),p=0.03] was independently associated with mortality. Incident heart failure developed in 43%(28/65) with no pre-existing HF, of whom 75% had HFPEF and 25% HFrEF. The development of new systolic HF (but not HFPEF) was associated with increased age and sex adjusted mortality [HR 3.0(1.0-7.9), p=0.045]. Conclusions: AVF creation is associated with worsening biventricular function and left atrial and RV dilatation, despite reduction in LV size. These changes are coupled with high incidence of new, unexplained heart failure. Further research is needed to identify the hemodynamic mechanisms underlying heart failure development in patients with ESRD requiring dialysis access.
Longitudinal Changes in Left Ventricular Stiffness
Redfield, Margaret M. , Melenovský, Vojtěch , Kane, Garvan C. , Karon, Barry L., Jacobsen, Steven J. , Rodeheffer, Richard J. , Borlaug, Barry A. , Melenovský, Vojtěch

Circulation: Heart Failure | June 29, 2013 | Volume: 6 | Issue: 5 | Pages: 944-952

10.1161/circheartfailure.113.000383 Get It

Background— Cross-sectional studies suggest that left ventricular (LV) and arterial elastance (stiffness) increase with age, but data examining longitudinal changes within human subjects are lacking. In addition, it remains unknown whether age-related LV stiffening is merely a reaction to arterial stiffening or caused by other processes. Methods and Results— Comprehensive echo-Doppler cardiography was performed in 1402 subjects participating in a randomly selected community-based study at 2 examinations separated by 4 years. From this population, 788 subjects had adequate paired data to determine LV end-systolic elastance (Ees), end-diastolic elastance (Eed), and effective arterial elastance. Throughout 4 years, blood pressure, arterial elastance, and LV mass decreased, coupled with significantly greater use of antihypertensive medications. However, despite reductions in arterial load, Ees increased by 14% (2.10±0.67–2.26±0.70 mm Hg/mL; P <0.0001) and Eed increased by 8% (0.13±0.03–0.14±0.04 mm Hg/mL; P <0.0001). Increases in Eed were greater in women than men, whereas Ees changes were similar. Age-related increases in Ees and Eed were correlated with changes in body weight, but were similar in subjects with or without cardiovascular disease. Changes in Ees were correlated with Eed ( r =0.5; P <0.0001), but not with other measures of contractility, indicating that the increase in Ees was reflective of passive stiffening rather than enhanced systolic function. Conclusions— Despite reductions in arterial load with medical therapy, LV systolic and diastolic stiffness increase over time in humans, particularly in women. In addition to blood pressure control, therapies targeting load-independent ventricular stiffening may be effective to treat and prevent age-associated cardiovascular diseases, such as heart failure.
Brief Report: Rheumatoid Arthritis Is Associated With Left Ventricular Concentric Remodeling: Results of a Population‐Based Cross‐Sectional Study
Davis, John M. , Crowson, Cynthia S. , Roger, Véronique L. , Karon, Barry L., Borgeson, Daniel D., Therneau, Terry M. , Matteson, Eric L. , Rodeheffer, Richard J. , Gabriel, Sherine E., Myasoedova, Elena , Davis, John M

Arthritis & Rheumatism | April 1, 2013 | Volume: 65 | Issue: 7 | Pages: 1713-1718

10.1002/art.37949 Get It

ObjectiveTo study left ventricular (LV) geometry in patients with rheumatoid arthritis (RA) and no history of heart failure compared with that in subjects with neither RA nor a history of heart failure, and to determine the impact of RA on LV remodeling.MethodsA cross‐sectional, community‐based study was conducted among adult (age ≥50 years) patients with RA and age‐ and sex‐matched subjects with neither RA nor a history of heart failure. All participants underwent standard 2‐dimensional Doppler echocardiography. LV geometry was classified into the following 4 categories based on relative wall thickness and sex‐specific cutoffs for the LV mass index: concentric remodeling, concentric hypertrophy, eccentric hypertrophy, or normal geometry.ResultsAmong 200 patients with RA and 600 age‐ and sex‐matched subjects without RA, the mean age was 65 years, and 74% of the individuals in both cohorts were female. Compared with subjects without RA, patients with RA were significantly more likely to have abnormal LV geometry (odds ratio [OR] 1.44, 95% confidence interval [95% CI] 1.03–2.00), even after adjusting for cardiovascular risk factors and comorbidities. Among subjects with abnormal LV geometry, the odds of concentric LV remodeling were significantly increased in patients with RA (OR 4.73, 95% CI 2.85–7.83). In linear regression analyses, the LV mass index appeared to be lower in patients with RA who were currently receiving corticosteroids (β ± SE −0.082 ± 0.027, P = 0.002), even after adjusting for cardiovascular risk factors and comorbidities.ConclusionRA was strongly associated with abnormal LV remodeling (particularly concentric LV remodeling) among RA patients without heart failure. This association remained significant after adjustment for cardiovascular risk factors and comorbidities. RA disease–related factors may promote changes in LV geometry. The biologic mechanisms underlying LV remodeling warrant further investigation.
Strain Dyssynchrony Index Correlates With Improvement in Left Ventricular Volume After Cardiac Resynchronization Therapy Better Than Tissue Velocity Dyssynchrony Indexes
Miyazaki, Chinami , Lin, Grace, Powell, Brian D. , Espinosa, Raúl E. , Miller, Fletcher A., Karon, Barry L., Rea, Robert F., Hayes, David L. , Oh, Jae K. , Bruce, Charles J.

Circulation: Cardiovascular Imaging | July 23, 2008 | Volume: 1 | Issue: 1 | Pages: 14-22

10.1161/circimaging.108.774513 Get It

Background— Various dyssynchrony indexes derived from tissue velocity and strain imaging have been proposed to predict the effectiveness of cardiac resynchronization therapy (CRT). We sought to compare the effect of CRT on dyssynchrony indexes derived by tissue velocity and strain and to determine which baseline intraventricular dyssynchrony parameters correlate with improvement in left ventricular volume after CRT. Methods and Results— Echocardiography with tissue Doppler imaging was performed in 45 patients with systolic heart failure at baseline, 1 day after CRT, and a median of 6 months after CRT. We calculated septal–lateral delay and anteroseptal–posterior delay and standard deviation of time to peak systolic velocity in the 12 basal and mid-left ventricular segments (Tv-SD). The standard deviation for time to peak strain in the 12 basal and mid-left ventricular segments (Tε-SD) was calculated as a strain-derived dyssynchrony index. None of the tissue velocity–derived dyssynchrony indexes improved after CRT (septal–lateral delay, P =0.39; anteroseptal–posterior delay, P =0.46; Tv-SD, P =0.30), whereas Tε-SD decreased significantly after CRT ( P <0.001). Improvement in Tε-SD 1 day after CRT correlated with the reduction in end-systolic volume at follow-up ( r =0.66; P <0.001). Baseline Tε-SD demonstrated significant correlation with the reduction of end-systolic volume at follow-up ( r =0.57; P <0.001); however, baseline tissue velocity–derived dyssynchrony indexes failed to predict the effect of CRT. Conclusions— The strain-derived dyssynchrony index is a better measurement than the tissue velocity dyssynchrony index for monitoring changes in mechanical dyssynchrony after CRT and for predicting reduction in left ventricular volume after CRT.
Prostate Brachytherapy Seed Migration To A Coronary Artery Found During Angiography
Bresnahan, John F., Stafford, Scott L., Karon, Barry L., King, Bernard F., Wilson, Torrence M., Davis, Brian J.

Journal of Urology | January 18, 2006 | Volume: 168 | Issue: 3 | Pages: 1103-1103

10.1016/s0022-5347(05)64589-2 Get It