Abstract BACKGROUND Anticoagulation protocols used during mechanical circulatory support call for titration of antiplatelet agents. We compared the precision and reliability of 5 platelet function tests in healthy volunteers and donors on daily antiplatelet therapy to distinguish their efficacy for titrating antiplatelet therapy. METHODS We assessed arachidonic acid–induced platelet function by light transmission aggregometry (LTA), Multiplate impedance aggregometry, VerifyNow, and platelet mapping by thromboelastography (TEG PM). We assessed ADP-induced platelet function by the same methods and flow cytometry. Forty healthy volunteers and 10–13 volunteers on daily aspirin and/or clopidogrel therapy were evaluated. We compared tests for intraassay precision, interassay precision (samples from 2 separate blood draws), and reliability coefficient. RESULTS For arachidonic acid–induced platelet aggregation in healthy volunteers, intra- and interassay CVs were ≤10% for all methods. Intra- and interassay precision among donors on daily aspirin was ≤30% for all methods except LTA (38% interassay CV) and TEG PM (95% intraassay and 104% interassay CV). For ADP-induced platelet function, intra- and interassay precision was ≤10% and ≤30% for all methods. Only Multiplate demonstrated moderate or greater (R > 0.40) reliability coefficients for arachidonic acid–induced platelet function among all subjects. All methods of ADP-induced platelet function, except TEG PM, demonstrated substantial or greater (R > 0.60) reliability among all subjects. CONCLUSIONS TEG PM is least suited to monitor effects of antiplatelet agents. Multiplate impedance aggregometry was the only method to demonstrate an acceptable reliability coefficient among healthy volunteers and donors on both aspirin and clopidogrel therapy.
Local Verification and Assignment of Mean Normal Prothrombin Time and International Sensitivity Index Values across Various Instruments: Recent Experience and Outcome from North America
Abstract Objectives: To compare thromboelastography (TEG) tracings obtained from fresh and citrated whole-blood samples in patients on extracorporeal membrane oxygenation (ECMO) or after cardiopulmonary bypass and in healthy volunteers. Methods: Samples of fresh and citrated whole blood were analyzed for 25 patients and 4 healthy volunteers. Thromboelastography analysis was performed in both plain and heparinase cups. Results: In 5 of 6 patients on ECMO, use of citrated samples resulted in apparent partial or complete heparin reversal. In TEG tracings from patients following cardiopulmonary bypass, there was a slight hypercoagulable appearance in the citrated sample. No differences were noted between fresh and citrated samples from healthy volunteers whose blood was spiked with heparin. Conclusions: In some patients on ECMO, use of samples collected in sodium citrate tubes for TEG analysis results in significant artifacts, which could lead to heparin overdosing in these patients.
Accuracy of Whole Blood Glucose Measurement When Venous Catheter Blood Samples Are Used on Glucose Meters
Background: Previous studies have found positive bias and frequent outliers when central venous catheter (CVC) whole blood is used to dose glucose meters. We designed a study to determine whether positive bias and outliers with CVC whole blood glucose samples are due to exogenous glucose contamination of CVC samples, inherent bias and imprecision of glucose meters, or properties of CVC whole blood that interfere with the function of some glucose meters. Methods: We studied the relationship between venous whole blood and venous plasma glucose drawn by venipuncture to CVC whole blood and CVC plasma glucose in 50 hospitalized patients. In 27 patients whole blood glucose was measured on both the Accu-Chek ® Inform (Roche Diagnostics, Indianapolis, IN) and StatStrip™ (Nova Biomedical, Waltham, MA). Results: By comparing CVC plasma to venous plasma glucose, we determined that contamination of CVC samples with exogenous glucose was uncommon. On the Inform meter outliers were approximately twice as common with CVC whole blood compared to venous whole blood. In 27 patients who had CVC whole blood analyzed by both Inform and StatStrip, outliers occurred approximately twice as often on the Inform compared to the StatStrip. Accounting for CVC samples contaminated with exogenous glucose, outliers on the StatStrip did not occur significantly more often using CVC whole blood compared to venous whole blood. Conclusions: Properties unique to CVC whole blood differentially affect glucose meter bias and imprecision. Device selection is critical in practices that wish to use CVC whole blood to monitor glucose concentration in hospitalized patients.