Somatotopic heat pain thresholds and intraepidermal nerve fibers in health
Davies, Jenny L., Engelstad, JaNean , Gove, Linde E., Linbo, L., Carter, Rickey E. , Staff, Nathan P. , Dyck, Peter James , Herrmann, David N. , E Gove, Linde, Linbo, Linda K, Staff, Nathan P , Carter, Rickey E , Lynch, Christopher, Klein, Christopher J.

Muscle & Nerve | March 15, 2018 | Volume: 58 | Issue: 4 | Pages: 509-516

10.1002/mus.26128 Get It

ABSTRACTIntroduction: For sequential and somatotopic assessment of small fiber neuropathy, heat pain (HP) tests of hypoalgesia might be used instead of decreased counts of epidermal nerve fibers (ENFs), but then healthy subject reference values of HP thresholds are needed. Methods: Using the Computer Assisted Sensation Evaluator IVc system, HP thresholds of hypoalgesia were estimated for 10 unilateral sites and counts of ENFs for 4 of them in healthy subjects. Results: In healthy subjects, small but statistically significant differences of both HP thresholds of hypoalgesia and counts of ENFs were observed among tested sites. Significant correlations between HP thresholds and counts of ENFs were not found. Discussion: For the studied somatotopic sites, we provide ≥95th and ≥99th percentile reference limits for HP 0.5 and 5 of 1–10 HP thresholds of hypoalgesia and decreased counts of ENFs at ≤5th and ≤1st percentile levels. Muscle Nerve 58: 509–516, 2018
Impact of electronic clinical decision support on adherence to guideline-recommended treatment for hyperlipidaemia, atrial fibrillation and heart failure: protocol for a cluster randomised trial
Kessler, Maya , Carter, Rickey E. , Cook, David A. , Kor, Daryl J. , Pencille, Laurie J., Scheitel, Marianne, Chaudhry, Rajeev , Kessler, Maya Elizabeth, Kor, Daryl Jon, McKie, Paul M. , Scheitel, Marianne R, Carter, Rickey E

BMJ Open | December 5, 2017 | Volume: 7 | Issue: 12 | Pages: e019087

10.1136/bmjopen-2017-019087 Get It

Introduction Clinical practice guidelines facilitate optimal clinical practice. Point of care access, interpretation and application of such guidelines, however, is inconsistent. Informatics-based tools may help clinicians apply guidelines more consistently. We have developed a novel clinical decision support tool that presents guideline-relevant information and actionable items to clinicians at the point of care. We aim to test whether this tool improves the management of hyperlipidaemia, atrial fibrillation and heart failure by primary care clinicians. Methods/analysis Clinician care teams were cluster randomised to receive access to the clinical decision support tool or passive access to institutional guidelines on 16 May 2016. The trial began on 1 June 2016 when access to the tool was granted to the intervention clinicians. The trial will be run for 6 months to ensure a sufficient number of patient encounters to achieve 80% power to detect a twofold increase in the primary outcome at the 0.05 level of significance. The primary outcome measure will be the percentage of guideline-based recommendations acted on by clinicians for hyperlipidaemia, atrial fibrillation and heart failure. We hypothesise care teams with access to the clinical decision support tool will act on recommendations at a higher rate than care teams in the standard of care arm. Ethics and dissemination The Mayo Clinic Institutional Review Board approved all study procedures. Informed consent was obtained from clinicians. A waiver of informed consent and of Health Insurance Portability and Accountability Act (HIPAA) authorisation for patients managed by clinicians in the study was granted. In addition to publication, results will be disseminated via meetings and newsletters. Trial registration number NCT02742545 .
High Glucose Variability in Hospitalized Patients with Type 1 Diabetes Mellitus
Dadlani, Vikash, Tamhane, Shrikant , Sun, Ai-dong, Sharma, Anu , Delivanis, Danae A. , Thapa, Prabin , Carter, Ricky E., Kudva, Yogish C. , Carter, Rickey E. , Tamhane, Shrikant U, Sun, Aidong, Carter, Rickey E

Diabetes Technology & Therapeutics | October 18, 2017 | Volume: 19 | Issue: 10 | Pages: 572-579

10.1089/dia.2017.0107 Get It

Background: Glucose variability (GV) has been increasingly (or more extensively) studied in patients with type 1 diabetes (T1D) in the ambulatory setting; limited data exist on GV in hospitalized patients with T1D. Materials and Methods: Retrospective single center cohort study, we analyzed in-hospital glucose measurements to assess GV in 736 hospitalized patients in different units over a consecutive 5-year period of time. GV was assessed by mean blood glucose (BG), Average daily risk range (ADRR), high BG index, and low BG index. To place our findings in context, we conducted a systematic review using Cochrane collaboration methodology to critically analyze current published literature on GV in hospitalized T1D patients. Results: Overall, glycemic control was suboptimal with mean BG 183 ± 51.5 mg/dL and mean ADRR 35 with only 16% patients being categorized as low risk (ADRR <20) for hypo or hyperglycemia. Patients admitted in medical units had mean BG of 194.4 ± 42.8 mg/dL (95% CI = 101.2–346.6) and ADRR of 39.4 ± 16 (95% CI = 1.3–118.7), which were higher than the patients admitted in the surgical units (mean BG 168.1 ± 35.7 (95% CI = 74.8–301.8) and mean ADRR (28.8 ± 13.1 [95% CI = 0.3–93.1]). For the systematic review, initial search yielded 2336 studies for screening, however, none of them had data specific for T1D. Conclusion: GV is high in hospitalized T1D patients admitted at our tertiary care center. Review of the literature shows paucity of data regarding GV in hospitalized patients with T1D.
Twelve-Week 24/7 Ambulatory Artificial Pancreas With Weekly Adaptation of Insulin Delivery Settings: Effect on Hemoglobin A1c and Hypoglycemia
Dassau, Eyal , Pinsker, Jordan E. , Kudva, Yogish C. , Brown, Sue A. , Gondhalekar, Ravi , Man, Chiara Dalla , Patek, Steve, Schiavon, Michele , Dadlani, Vikash, Dasanayake, Isuru , Church, Mei Mei , Carter, Rickey E. , Bevier, Wendy C. , Huyett, Lauren M. , Hughes, Jonathan , Anderson, Stacey M. , Lv, Dayu, Schertz, Elaine, Emory, Emma, McCrady-Spitzer, Shelly , Jean, Tyler, Bradley, Paige K., Hinshaw, Ling , Sanz, Alejandro José Laguna , Basu, Ananda , Kovatchev, Boris , McCrady-Spitzer, Shelly K, Cobelli, Claudio , Doyle, Francis J , Dalla Man, Chiara , Carter, Rickey E , Kovatchev, Boris , Cobelli, Claudio , Doyle, Francis J. , Schiavon, Michele

Diabetes Care | October 14, 2017 | Volume: 40 | Issue: 12 | Pages: 1719-1726

10.2337/dc17-1188 Get It

OBJECTIVE Artificial pancreas (AP) systems are best positioned for optimal treatment of type 1 diabetes (T1D) and are currently being tested in outpatient clinical trials. Our consortium developed and tested a novel adaptive AP in an outpatient, single-arm, uncontrolled multicenter clinical trial lasting 12 weeks. RESEARCH DESIGN AND METHODS Thirty adults with T1D completed a continuous glucose monitor (CGM)-augmented 1-week sensor-augmented pump (SAP) period. After the AP was started, basal insulin delivery settings used by the AP for initialization were adapted weekly, and carbohydrate ratios were adapted every 4 weeks by an algorithm running on a cloud-based server, with automatic data upload from devices. Adaptations were reviewed by expert study clinicians and patients. The primary end point was change in hemoglobin A1c (HbA1c). Outcomes are reported adhering to consensus recommendations on reporting of AP trials. RESULTS Twenty-nine patients completed the trial. HbA1c, 7.0 ± 0.8% at the start of AP use, improved to 6.7 ± 0.6% after 12 weeks (−0.3, 95% CI −0.5 to −0.2, P &lt; 0.001). Compared with the SAP run-in, CGM time spent in the hypoglycemic range improved during the day from 5.0 to 1.9% (−3.1, 95% CI −4.1 to −2.1, P &lt; 0.001) and overnight from 4.1 to 1.1% (−3.1, 95% CI −4.2 to −1.9, P &lt; 0.001). Whereas carbohydrate ratios were adapted to a larger extent initially with minimal changes thereafter, basal insulin was adapted throughout. Approximately 10% of adaptation recommendations were manually overridden. There were no protocol-related serious adverse events. CONCLUSIONS Use of our novel adaptive AP yielded significant reductions in HbA1c and hypoglycemia.
Low‐dose CT for the detection and classification of metastatic liver lesions: Results of the 2016 Low Dose CT Grand Challenge
Bartley, Adam C. , Carter, Rickey E. , Chen, Baiyu , Drees, Tammy A., Edwards, Phillip K , Holmes, David R. , Huang, Alice E. , Khan, Farhana, McMillan, Kyle, Michalak, Gregory J. , Nunez, Kristina M., Yu, Lifeng , Edwards, Phillip, McMillan, Kyle L, Carter, Rickey E , McCollough, Cynthia H. , Leng, Shuai , Yu, Lifeng , Fletcher, Joel G.

Medical Physics | October 13, 2017 | Volume: 44 | Issue: 10 | Pages: No page available

10.1002/mp.12345 Get It

Purpose Using common datasets, to estimate and compare the diagnostic performance of image‐based denoising techniques or iterative reconstruction algorithms for the task of detecting hepatic metastases. Methods Datasets from contrast‐enhanced CT scans of the liver were provided to participants in an NIH ‐, AAPM ‐ and Mayo Clinic‐sponsored Low Dose CT Grand Challenge. Training data included full‐dose and quarter‐dose scans of the ACR CT accreditation phantom and 10 patient examinations; both images and projections were provided in the training data. Projection data were supplied in a vendor‐neutral standardized format ( DICOM ‐ CT ‐ PD ). Twenty quarter‐dose patient datasets were provided to each participant for testing the performance of their technique. Images were provided to sites intending to perform denoising in the image domain. Fully preprocessed projection data and statistical noise maps were provided to sites intending to perform iterative reconstruction. Upon return of the denoised or iteratively reconstructed quarter‐dose images, randomized, blinded evaluation of the cases was performed using a Latin Square study design by 11 senior radiology residents or fellows, who marked the locations of identified hepatic metastases. Markings were scored against reference locations of clinically or pathologically demonstrated metastases to determine a per‐lesion normalized score and a per‐case normalized score (a faculty abdominal radiologist established the reference location using clinical and pathological information). Scores increased for correct detections; scores decreased for missed or incorrect detections. The winner for the competition was the entry that produced the highest total score (mean of the per‐lesion and per‐case normalized score). Reader confidence was used to compute a Jackknife alternative free‐response receiver operating characteristic ( JAFROC ) figure of merit, which was used for breaking ties. Results 103 participants from 90 sites and 26 countries registered to participate. Training data were shared with 77 sites that completed the data sharing agreements. Subsequently, 41 sites downloaded the 20 test cases, which included only the 25% dose data ( CTDI vol = 3.0 ± 1.8 mG y, SSDE = 3.5 ± 1.3 mG y). 22 sites submitted results for evaluation. One site provided binary images and one site provided images with severe artifacts; cases from these sites were excluded from review and the participants removed from the challenge. The mean (range) per‐lesion and per‐case normalized scores were −24.2% (−75.8%, 3%) and 47% (10%, 70%), respectively. Compared to reader results for commercially reconstructed quarter‐dose images with no noise reduction, 11 of the 20 sites showed a numeric improvement in the mean JAFROC figure of merit. Notably two sites performed comparably to the reader results for full‐dose commercial images. The study was not designed for these comparisons, so wide confidence intervals surrounded these figures of merit and the results should be used only to motivate future testing. Conclusion Infrastructure and methodology were developed to rapidly estimate observer performance for liver metastasis detection in low‐dose CT examinations of the liver after either image‐based denoising or iterative reconstruction. The results demonstrated large differences in detection and classification performance between noise reduction methods, although the majority of methods provided some improvement in performance relative to the commercial quarter‐dose images with no noise reduction applied.
Radiation dose reduction during neuroendovascular procedures
Morris, Pearse , Geer, Carol P. , Singh, Jasmeet , Brinjikji, Waleed , Carter, Rickey E. , Morris, Pearse P, Carter, Rickey E

Journal of NeuroInterventional Surgery | September 23, 2017 | Volume: 10 | Issue: 5 | Pages: 481-486

10.1136/neurintsurg-2017-013189 Get It

Aim To describe the impact of steps towards reduction of procedural doses of radiation during neuroendovascular procedures. Methods Phantom exposures under controlled circumstances were performed using a Rando-Alderson adult-sized head phantom. Customized imaging protocols were devised for pediatric and adult imaging and implemented in clinical use. Outcome data for estimated skin doses (ESD) and dose–area product (DAP) following pediatric and adult diagnostic and interventional procedures over 4.5 years were analyzed retrospectively. Results Dose estimates were reduced by 50% or more after introduction of customized imaging protocols in association with modification of personnel behavior compared with doses recorded with previously used vendor-recommended protocols. Discussion Substantial reductions in radiation use during neuroendovascular procedures can be achieved through a combination of equipment modification and operator behavior.
Quantitative assessment of lung stiffness in patients with interstitial lung disease using MR elastography
Marinelli, John P. , Levin, David L. , Hubmayr, Rolf D., McGee, Kiaran P. , Vassallo, Robert , Carter, Rickey E. , Ehman, Richard L.

Journal of Magnetic Resonance Imaging | July 13, 2017 | Volume: 46 | Issue: 2 | Pages: No page available

10.1002/jmri.25805 Get It

PurposeTo investigate the use of magnetic resonance elastography (MRE) in the quantitative assessment of pulmonary fibrosis by comparing quantitative shear stiffness measurements of lung parenchyma in patients diagnosed with fibrotic interstitial lung disease (ILD) and healthy controls.Materials and MethodsA 1.5T spin‐echo, echo planar imaging MRE (SE‐EPI MRE) pulse sequence was utilized to assess absolute lung shear stiffness in 15 patients with diagnosed ILD and in 11 healthy controls. Data were collected at residual volume (RV) and total lung capacity (TLC). Spirometry data were obtained immediately prior to scanning. To test for statistical significance between RV and TLC shear stiffness estimates a two‐sample t‐test was performed. To assess variability within individual subject shear stiffness estimates, the intraclass correlation coefficient (ICC) and Krippendorff's alpha were calculated.ResultsPatients with ILD exhibited an average (±1 standard deviation) shear stiffness of 2.74 (±0.896) kPa at TLC and 1.32 (±0.300) kPa at RV. The corresponding values for healthy individuals were 1.33 (±0.195) kPa and 0.849 (±0.250) kPa, respectively. The difference in shear stiffness between RV and TLC was statistically significant (P < 0.001). At TLC, the ICC and alpha values were 0.909 and 0.887, respectively. At RV, the ICC and alpha values were 0.852 and 0.862, respectively.ConclusionIn subjects with known fibrotic interstitial lung disease, parenchymal shear stiffness is increased when compared to normal controls at both RV and TLC, with TLC demonstrating the most significant difference. MRE‐derived parenchymal shear stiffness is a promising new noninvasive imaging‐based biomarker of interstitial lung disease.Level of Evidence:1J. MAGN. RESON. IMAGING 2017;46:1–1
Automated low‐contrast pattern recognition algorithm for magnetic resonance image quality assessment
Ehman, Morgan O., Bao, Zhonghao , Stiving, Scott O., Kasam, Mallikarjunarao , Lanners, Dianna , Peterson, Teresa, Jonsgaard, Renee , Carter, Rickey E. , McGee, Kiaran P. , Kasam, Mallik, Carter, Rickey, Carter, Rickey E

Medical Physics | May 25, 2017 | Volume: 44 | Issue: 8 | Pages: 4009-4024

10.1002/mp.12370 Get It

PurposeLow contrast (LC) detectability is a common test criterion for diagnostic radiologic quality control (QC) programs. Automation of this test is desirable in order to reduce human variability and to speed up analysis. However, automation is challenging due to the complexity of the human visual perception system and the ability to create algorithms that mimic this response. This paper describes the development and testing of an automated LC detection algorithm for use in the analysis of magnetic resonance (MR) images of the American College of Radiology (ACR) QC phantom.MethodsThe detection algorithm includes fuzzy logic decision processes and various edge detection methods to quantify LC detectability. Algorithm performance was first evaluated using a single LC phantom MR image with the addition of incremental zero mean Gaussian noise resulting in a total of 200 images. A c‐statistic was calculated to determine the role of CNR to indicate when the algorithm would detect ten spokes. To evaluate inter‐rater agreement between experienced observers and the algorithm, a blinded observer study was performed on 196 LC phantom images acquired from nine clinical MR scanners. The nine scanners included two MR manufacturers and two field strengths (1.5 T, 3.0 T). Inter‐rater and algorithm‐rater agreement was quantified using Krippendorff's alpha.ResultsFor the Gaussian noise added data, CNR ranged from 0.519 to 11.7 with CNR being considered an excellent discriminator of algorithm performance (c‐statistic = 0.9777). Reviewer scoring of the clinical phantom data resulted in an inter‐rater agreement of 0.673 with the agreement between observers and algorithm equal to 0.652, both of which indicate significant agreement.ConclusionsThis study demonstrates that the detection of LC test patterns for MR imaging QC programs can be successfully developed and that their response can model the human visual detection system of expert MR QC readers.
Percutaneous Pericardial Resection
Borlaug, Barry A. , Carter, Rickey E. , Melenovský, Vojtěch , Gaba, Prakriti , Killu, Ammar M. , Naksuk, Niyada , Lerman, Lilach O. , Asirvatham, Samuel J. , Killu, Ammar, Lerman, Lilach, DeSimone, Christopher V. , Asirvatham, Samuel J , Borlaug, Barry A , Carter, Rickey E , Melenovský, Vojtěch

Circulation: Heart Failure | April 11, 2017 | Volume: 10 | Issue: 4 | Pages: No page available

10.1161/circheartfailure.116.003612 Get It

Background— People with heart failure and preserved ejection fraction develop increases in left ventricular (LV) end-diastolic pressures during exercise that contribute to dyspnea. In normal open-chest animal preparations, the pericardium restrains LV filling when central blood volume increases. We hypothesized that resection of the pericardium using a minimally invasive epicardial approach would mitigate the increase in LV end-diastolic pressure that develops during volume loading in normal and diseased hearts with the chest intact. Methods and Results— Invasive hemodynamic assessment was performed at baseline and after saline load before and after pericardial resection in normal canines with open (n=3) and closed chest (n=5) and in a pig model with features of human heart failure and preserved ejection fraction with sternum intact (n=4). In closed-chest animals, pericardiotomy was performed using a novel subxiphoid procedure. In both experimental preparations of normal dogs, pericardiotomy blunted the increase in LV end-diastolic pressure with saline infusion, while enhancing the saline-mediated increase in LV end-diastolic volume. With chest intact in the pig model, percutaneous pericardial resection again blunted the increase in LV end-diastolic pressure secondary to volume expansion (+4±3 versus +13±5 mm Hg; P =0.014), while enhancing the saline-mediated increase in LV end-diastolic volume (+17±1 versus +10±2 mL; P =0.016). Conclusions— This proof of concept study demonstrates that pericardial resection through a minimally invasive percutaneous approach mitigates the elevation in LV filling pressures with volume loading in both normal animals and a pig model with diastolic dysfunction. Further study is warranted to determine whether this method is safe and produces similar acute and chronic hemodynamic benefits in people with heart failure and preserved ejection fraction.
Continuous Glucose Monitor Interference With Commonly Prescribed Medications: A Pilot Study
Basu, Ananda , Slama, Michael , Nicholson, Wayne T. , Langman, Loralie J., Peyser, Thomas A. , Carter, Rickey E. , Basu, Rita , Slama, Michael Q, Langman, Loralie, Carter, Rickey E

Journal of Diabetes Science and Technology | March 23, 2017 | Volume: 11 | Issue: 5 | Pages: 936-941

10.1177/1932296817697329 Get It

Background: Reliability of continuous glucose monitors (CGM) is a prerequisite for therapeutic dosing of insulin without the need for confirmatory blood glucose meter measurements. Interference of CGMs with commonly prescribed substances has not been extensively evaluated. Methods: We sought to undertake a novel pilot study to determine the susceptibility of FDA-approved CGM systems (Medtronic Guardian Sof-Sensor, Dexcom G4 Platinum) to erroneous readings in the presence of common medications. CGMs were placed on the abdomen of healthy subjects 48 hours prior to study. Subjects were admitted to the Clinical Research Trials Unit (CRTU) on the evening before study and fed a standard supper. The following morning, an oral medication was administered in the fasted state and blood was sampled for 9 hours. CGM values were compared to ambient glucose (measured with YSI) to observe variations in CGM readings. Microdialysis catheters were also placed in the abdomen to sample interstitial fluid (ISF) for drug concentrations. Results: Nineteen healthy drug-naïve subjects without diabetes participated in the study. A drug/substance was tested up to a maximum of nine times on separate occasions. Comparison of CGM glucose patterns to actual plasma glucose concentrations show several drugs, including lisinopril, albuterol, and acetaminophen, appear to interfere with commonly used CGM devices. Wine also interfered with CGM readings. Conclusions: We conclude there is some evidence of CGM interference with lisinopril, albuterol, acetaminophen, atenolol, and red wine. Future studies are required to address interference with newer sensors being approved or in the process of approval.