Back to Authors

Bilgin, Cem

https://orcid.org/0000-0003-1832-1278

Mayo Clinic

Mayo Clinic

Citations 28

Comparative analysis of single plane and biplane angiography systems for mechanical thrombectomy for acute ischemic stroke: a systematic review and meta-analysis
Orscelik, Atakan , Bilgin, Cem , Cortese, Jonathan , Cayme, Joshua J , Şenol, Yiğit Can , Musmar, Basel , Ghozy, Sherief , Bayraktar, Esref Alperen , Beizavi, Zahra , Brinjikji, Waleed , Kallmes, David F. , Senol, Yigit Can , Musmar, Basel , Ghozy, Sherief , Bayraktar, Esref Alperen , Brinjikji, Waleed , Orscelik, Atakan , Cortese, Jonathan , Zandpazandi, Sara

Journal of NeuroInterventional Surgery | October 22, 2024 | Volume: 17 | Issue: 6 | Pages: 567-573

10.1136/jnis-2024-022381 Get It

Background The choice of angiography system could influence the outcomes of mechanical thrombectomy (MT) in the treatment of acute ischemic stroke (AIS), but its impact is not yet well understood. This study aims to compare the clinical and technical outcomes of MT performed with single plane versus biplane angiography systems. Method We conducted a systematic review and meta-analysis, following PRISMA guidelines, by searching PubMed, Embase, Web of Science, and Scopus to include studies on patients with AIS who underwent MT with either single plane or biplane angiography up to May 4, 2024. The primary outcome was a favorable outcome defined as a modified Rankin Scale (mRS) score of 0–2 at 90 days after the procedure. Data were analyzed using a random-effects model and heterogeneity was assessed using the I2 test and Q statistics. Results Five studies with a total of 1562 patients were analyzed. Of these, 68.4% were treated with biplane systems and 31.6% with single plane systems. Single plane angiography was associated with a significantly higher rate of favorable outcomes (OR 1.43; 95% CI 1.13 to 1.80; P<0.01). There were no significant differences in successful recanalization, periprocedural complications, procedure time, total fluoroscopy time, or contrast volume between the two systems. Conclusion While single plane angiography systems may offer slightly better outcomes in MT for AIS, both systems appear equally effective in most clinical and technical perspectives, suggesting that system selection may be more dependent on availability and procedural requirements rather than inherent superiority. Our findings may encourage clinicians to use single-plane angiography in settings where the biplane angiography suite availability is limited, but it should be noted that this observation may have been influenced by selection bias, particularly since the larger studies included in our meta-analysis did not observe this effect in adjusted analyses for potential confounder factors.
E-164 Safety profile of surgical embolectomy in acute ischemic stroke patients: a systematic review and meta-analysis
Pakkam, Madona , Bilgin, Cem , Kadirvel, R, Kallmes, D, Orscelik, Atakan , Musmar, Basel , Senol, Y, Ghozy, Sherief , Kadirvel, Ramanathan , Kallmes, David F.

SNIS 21st annual meeting electronic poster abstracts | July 22, 2024 | Volume: No volume available | Issue: No issue available | Pages: A183.2-A184

10.1136/jnis-2024-snis.269 Get It

Pipeline versus non-pipeline flow diverter treatment for M1 aneurysms: A systematic review and meta-analysis
Şenol, Yiğit Can , Orscelik, Atakan , Bilgin, Cem , Kallmes, David F. , Kadirvel, Ramanathan , Arul, Santhosh , Orscelik, Atakan , Senol, Yigit Can , Kobeissi, Hassan , Ghozy, Sherief

The Neuroradiology Journal | July 21, 2024 | Volume: 38 | Issue: 2 | Pages: 133-141

10.1177/19714009241260805 Get It

Background The flow diversion treatment of aneurysms located distal to the Circle of Willis has recently increased in frequency. We conducted a systematic review and meta-analysis of the clinical and radiological outcomes of flow diverter (FD) embolization in treating M1 aneurysms. Methods PubMed, Web of Science, Ovid Medline, Ovid Embase, and Scopus were searched up to May 2024 using the Nested Knowledge platform. We included studies assessing the long-term clinical and radiological outcomes for M1 aneurysms. Results of FDs classified as Pipeline Embolization Devices (PED) versus other types of FDs. Angiographic occlusion rates, ischemic and hemorrhagic complications, and favorable clinic outcomes were included. All data were analyzed using R software version 4.2.2. Results Thirteen studies with 112 total patients (58 patients for PED and 54 patients for other FD devices) were included in our meta-analysis. The overall adequate (complete + near-complete) occlusion rates were 85.1%. The complete occlusion rate was higher with PED than with other FD devices (72.9% PED and 41.6% for non-PED FDs, respectively, p -value <.01). The ischemic complications were 9.9% and 9.0% for the PED and non-PED groups, respectively ( p -value = .89). The overall modified Rankin Scale 0–2 was 100% for the non-PED and 97.1% for the PED group ( p -value = .51). In-stent stenosis rate was 7.5% for PED devices compared to 2.6% in the non-PED group ( p -value = .35). Conclusions This relatively small meta-analysis showed high rates of adequate and complete occlusion in FD treatment of M1 segment aneurysms, with favorable safety profiles. PEDs were associated with higher rates of complete aneurysm occlusion compared to other types of FDs.
In vitro evaluation of flow diverter performance using a human fibrinogen–based flow model
Bilgin, Cem , Kallmes, David F. , Kadirvel, Ramanathan , Bayraktar, Esref Alperen , Oliver, Alexander A , Li, Jiahui , Cebral, Juan R.

Journal of Neurosurgery | July 12, 2024 | Volume: 142 | Issue: 1 | Pages: 154-161

10.3171/2024.4.jns232567 Get It

OBJECTIVE Fibrin deposition represents a key step in aneurysm occlusion, promoting endothelization of implants and connective tissue organization as part of the aneurysm-healing mechanism. In this study, the authors introduce a novel in vitro testing platform for flow diverters based on human fibrinogen. METHODS A flow diverter was deployed in 4 different glass models. The glass models had the same internal parent artery (4 mm) and aneurysm (8 mm) diameters with varying parent artery angulations (paraophthalmic, sidewall, bifurcation, and slightly curved models). The neck size and area were 4 mm and 25 mm 2 , respectively. Human fibrinogen (330 mg/dl) was circulated within the glass models at varying flow rates (0, 3, 4, and 5 ml/sec) with or without heparin, calcium chloride, and thrombin for as long as 6 hours or until complete fibrin coverage of the flow diverter’s neck was achieved. Aneurysm neck coverage was defined as macroscopic fibrin deposition occluding the flow diverters’ pores. Flow characteristics after flow diverter deployment were assessed with computational fluid dynamics analysis. The effects of flow rates, heparin, calcium chloride, and thrombin on fibrin deposition rates were tested using 1-way ANOVA and the Tukey test. RESULTS A total of 84 replicates were performed. Human fibrin did not accumulate on the flow diverter stents under static conditions. The fibrin deposition rate on the aneurysm neck was significantly greater with the 5 ml/sec flow rate as compared to 3 ml/sec for all models. The paraophthalmic model had the highest inflow velocity of 48.7 cm/sec. The bifurcation model had the highest maximum shear stress (SS) and maximum normalized shear stress values at the device cells at 843.3 dyne/cm 2 and 35.1 SS/SS inflow , respectively. The fibrin deposition rates of the paraophthalmic and bifurcation models were significantly higher than those of sidewall and slightly curved models for all additive or flow rate comparisons (p = 0.001 for all comparisons). The incorporation of thrombin significantly increased the fibrin deposition rates across all models (p = 0.001 for all models). CONCLUSIONS Rates of fibrin deposition varied widely across different configurations and additive conditions in this novel in vitro model system. Fibrin accumulation started at the aneurysm inflow zone where flow velocity and shear stress were the highest. The primary factors influencing fibrin deposition included flow velocities, shear stress, and the addition of thrombin at a physiological concentration. Further research is needed to test the clinical utility of fibrinogen-based models for patient-specific aneurysms.
Creating elastase aneurysms in rabbits: a video primer
Cortese, Jonathan , Bayraktar, Esref Alperen , Oliver, Alexander A , Bilgin, Cem , Ding, Yong-Hong, Ueki, Yasuhito , Lortscher, Sarah, Brinjikji, Waleed , Kadirvel, Ramanathan , Kallmes, David F. , Cortese, Jonathan , Bayraktar, Esref Alperen , Oliver, Alexander A , Ding, Yonghong

Journal of NeuroInterventional Surgery | June 11, 2024 | Volume: 17 | Issue: 10 | Pages: 1133-1133

10.1136/jnis-2024-021912 Get It

The New Zealand rabbit elastase-induced arterial aneurysm of the right common carotid artery remains a widely used model for assessing the effectiveness and safety of new neuroendovascular devices.1 This model offers a simple and reliable platform for pre-clinical in vivo investigations, crucial for comprehending the biological processes underlying aneurysm healing after endovascular treatment.2 Notably, the induced aneurysm exhibits morphological, hemodynamic, and histological characteristics similar to human intracranial aneurysms. The creation of the aneurysm is performed using open and endovascular techniques. Each step of the procedure requires a meticulous and controlled gesture to ensure reproducibility of the aneurysm and minimize animal misuse. In video 1 we present a step-by-step procedural guide for aneurysm creation and follow-up. We hope this resource will help in promoting this model and provide useful guidance for researchers in the field. Video 1 Surgical procedure of creating elastase-induced aneurysms in rabbits.
How the elastase-induced rabbit aneurysm heals following flow diverter treatment: a histopathological study
Bilgin, Cem , Kallmes, David F. , Kadirvel, Ramanathan , Dai, Daying , Ding, Yonghong , Ghozy, Sherief , Mereuta, Oana Madalina

Journal of Neurosurgery | May 17, 2024 | Volume: 141 | Issue: 5 | Pages: 1262-1269

10.3171/2024.2.jns232262 Get It

OBJECTIVE Fibrin deposition is integral to thrombus formation and wound healing. The role of fibrin deposition and subsequent metabolism following flow diversion for aneurysm treatment remains poorly characterized. This study aimed to evaluate the role of fibrin in early thrombus organization after flow diverter treatment. METHODS Thirty-five elastase-induced aneurysms were induced in New Zealand white rabbits and subjected to endoluminal flow diversion treatment. The device-bearing arteries were harvested at 1, 3, and 6 months postimplantation and processed for histopathological examination, including a modified picro-Mallory stain (Carstairs method) to visualize fibrin and platelets, immunohistochemical targeting of smooth muscle actin (SMA), and H&E staining for conventional morphological evaluation. Quantitative analysis of tissue components was carried out using the Orbit Image Analysis software. The samples were also assessed qualitatively to investigate the morphology and location of fibrin and other thrombus components within the intra-aneurysmal thrombi. Statistical analyses were conducted using R software version 4.3.1. RESULTS Fibrin constituted 27.9% of the thrombus tissue within the aneurysm sac for aneurysms harvested at 1 month, and this rate was significantly lower in the 3-month group (10.2%, p = 0.018). The proportion of blood cells within the sac was also notably higher in the 1-month group compared with other time points. The primary tissue filling the dome at 1 month (14/15, 93%) was an unorganized thrombus primarily composed of fibrin, platelets, and red blood cells. Conversely, aneurysms harvested at 1 month had the lowest collagen level (25.6%). However, collagen became the dominant tissue component within the aneurysm sac, accounting for 71.8% of tissue in the 3-month group (p = 0.007). There were no differences observed among the examined components between the 3-month and 6-month groups. On qualitative analysis, collagen-producing SMA-positive myofibroblasts were located near or in between fibrin molecules. Healed aneurysms exhibited myofibroblasts, collagen, and a well-organized fibrin network on the aneurysm neck. In contrast, unhealed aneurysms displayed a poorly organized fibrin network with scattered myofibroblasts at the neck area. CONCLUSIONS These findings indicate that fibrin plays a foundational role in the gradual occlusion of aneurysms after flow diverter treatment. Endovascular approaches that enhance fibrin accumulation could potentially improve aneurysm occlusion rates. Further research is needed to establish the precise role of fibrin in aneurysm occlusion.
Abstract 236: Effects of intravenous thrombolysis on thrombectomy outcomes: a systematic review and meta‐analysis
Tolba, Hatem , Bilgin, Cem , Hassankhani, Amir , Kadrivel, Ramanathan, Kallmes, David F. , Ghozy, Sherief , Kobeissi, Hassan , Senol, Yigit, Arul, Santhosh , Kadrivel, Ram

Stroke: Vascular and Interventional Neurology | March 5, 2024 | Volume: 3 | Issue: S2 | Pages: No page available

10.1161/svin.03.suppl_2.236 Get It

Introduction Efficacy and safety of intravenous thrombolysis (IVT) in patients undergoing mechanical thrombectomy (MT) is still debatable. However, IVT's efficacy on stent retriever (SR) and aspiration thrombectomy (ASP) outcomes specifically remain unclear. In our meta‐analysis, we aimed to explore the effects of IVT on SR and ASP thrombectomy outcomes. Methods A systematic literature review was steered using Medline, Embase, Scopus, Web of Science, and Cochrane Center of Clinical Trials databases, according to PRISMA guidelines. Outcomes of interest included successful recanalization (modified Thrombolysis In Cerebral Infarction (mTICI) ≥2b), functional independence (modified Rankin Scale (mRS) ≤2), modified first pass efficacy (mFPE), symptomatic intracranial hemorrhage (sICH), and embolization to new territories (ENT). Results We included four randomized controlled trials with 1176 patients. SR and ASP had similar mTICI ≥2b, mFPE, and mRS 0‐2 rates whether they received IVT or not. SR without IVT was associated with a lower rate of mFPE compared with the SR+IVT (RR 0.85, 95% CI 0.74 to 0.97). Additionally, ASP without IVT resulted in a lower rate of mRS 0‐2 than the ASP+IVT (RR 0.78, 95% CI 0.60 to 1.01). Finally, bridging therapy did not increase sICH and ENT rates after ASP or SR thrombectomy. Conclusion Our analysis suggests that SR and ASP thrombectomy have equivalent efficacy and safety outcomes regardless of prior IVT administration. Moreover, our results indicate that administration of IVT before MT may improve certain outcomes based on the used first‐line MT technique.
Common design and data elements reported in active mechanical thrombectomy trials focusing on distal medium vessel occlusions and minor strokes: a systematic review
Bilgin, Cem , Bolsegui, Marisabel Linares , Ghozy, Sherief , Hassankhani, Amir , Kobeissi, Hassan , Jabal, Mohamed Sobhi , Gupta, Rishabh , Rubeis, Gianluca De , Kadirvel, Ramanathan , Brinjikji, Waleed , Saba, Luca , Kallmes, David F. , De Rubeis, Gianluca , Ghozy, Sherief , Kobeissi, Hassan , Saba, Luca

Journal of NeuroInterventional Surgery | January 11, 2024 | Volume: 17 | Issue: 5 | Pages: 530-538

10.1136/jnis-2023-021073 Get It

Background Distal medium vessel occlusions (DMVOs) and minor strokes represent emerging frontiers in mechanical thrombectomy (MT). Although several randomized clinical trials (RCTs) are underway, the design characteristics of these trials and the specific questions they aim to address have not been extensively explored. This current study sought to investigate the design and data elements reported in active prospective DMVO and minor stroke studies. Methods The ClinicalTrials.gov database was searched for ongoing prospective studies assessing the role of MT in patients with DMVOs or minor strokes. The Nested Knowledge AutoLit platform was utilized to categorize reported outcomes and inclusion/exclusion criteria. Frequencies of reported data elements were extracted from study protocols. Results A total of 10 (8 DMVO and 2 minor stroke) studies enrolling 3520 patients were included. All DMVO studies employ different criteria regarding target occlusion locations. Five DMVO studies use stent retrievers as the first-line thrombectomy technique (62.5%, 5/8), while three studies allow any MT techniques, generally at the operator’s discretion. Four DMVO studies permit intravenous thrombolysis (IVT) utilization in both intervention and control arms (50%, 4/8). The DISTALS trial excludes patients receiving IVT, while the DUSK trial and Tigertriever registry only enroll patients who are ineligible for IVT or for whom IVT failed to achieve reperfusion. DMVO studies exhibit notable heterogeneity in symptom onset duration thresholds for inclusion (<6 hours: 2 studies; <12 hours: 2 studies; <24 hours: 3 studies). Minor stroke trials employ similar inclusion criteria and outcome measures except for symptom duration thresholds for inclusion (8 hours for ENDOLOW and 23 hours for MOSTE). Conclusions There is considerable heterogeneity among active DMVO trials regarding potential target DMVO locations and time thresholds for inclusion based on the last known well time. Furthermore, our review indicates that the utility of aspiration thrombectomy in DMVOs and the advantages of MT without IVT over IVT alone will remain largely unexplored even after completion of active DMVO trials.
Performance of ChatGPT-4 and Bard Chatbots in Responding to Common Patient Questions on Prostate Cancer 177Lu-PSMA-617 Therapy
Bilgin, Gokce Belge , Bilgin, Cem , Orme, Jacob J. , Burkett, Brian J. , Packard, Annie T. , Johnson, Geoffrey B. , Sartor, Oliver A., Johnson, Geoffrey B , Burkett, Brian , Belge Bilgin, Gokce , Childs, Daniel S. , Johnson, Derek R. , Thorpe, Matthew , Riaz, Irbaz Bin , Hálfdánarson, Þorvarður R. , Kendi, A. Tuba

No container title available | December 20, 2023 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-3728387/v1 Get It

Abstract Background: Many patients use artificial intelligence (AI) chatbots as a rapid source of health information. This raises important questions about the reliability and effectiveness of AI chatbots in delivering accurate and understandable information. Purpose: To evaluate and compare the accuracy, conciseness, and readability of responses from OpenAI ChatGPT-4 and Google Bard to patient inquiries concerning the novel 177Lu-PSMA-617 therapy for prostate cancer. Materials and Methods: Two experts listed the 12 most commonly asked questions by patients on 177Lu-PSMA-617 therapy. These twelve questions were prompted to OpenAI ChatGPT-4 and Google Bard. AI-generated responses were distributed using an online survey platform (Qualtrics) and blindly rated by eight experts. The performances of the AI chatbots were evaluated and compared across three domains: accuracy, conciseness, and readability. Additionally, potential safety concerns associated with AI-generated answers were also examined. The Mann-Whitney U and chi-square tests were utilized to compare the performances of AI chatbots. Results: Eight experts participated in the survey, evaluating 12 AI-generated responses across the three domains of accuracy, conciseness, and readability, resulting in 96 assessments (12 responses x 8 experts) for each domain per chatbot. ChatGPT-4 provided more accurate answers than Bard (2.95 ± 0.671 vs 2.73 ± 0.732, p=0.027). Bard's responses had better readability than ChatGPT-4 (2.79 ± 0.408 vs 2.94 ± 0.243, p=0.003). Both ChatGPT-4 and Bard achieved comparable conciseness scores (3.14 ± 0.659 vs 3.11 ± 0.679, p=0.798). Experts categorized the AI-generated responses as incorrect or partially correct at a rate of 16.6% for ChatGPT-4 and 29.1% for Bard. Bard's answers contained significantly more misleading information than those of ChatGPT-4 (p = 0.039). Conclusion: AI chatbots have gained significant attention, and their performance is continuously improving. Nonetheless, these technologies still need further improvements to be considered reliable and credible sources for patients seeking medical information on 177Lu-PSMA-617 therapy.
Effects of intravenous thrombolysis on stent retriever and aspiration thrombectomy outcomes: a systematic review and meta-analysis of the randomized controlled trials
Bilgin, Cem , Tolba, Hatem , Ghozy, Sherief , Kobeissi, Hassan , Hassankhani, Amir , Şenol, Yiğit Can , Kadirvel, Ramanathan , Kallmes, David F. , Arul, Santhosh , Kadirvel, Ram , Ghozy, Sherief , Kobeissi, Hassan , Senol, Yigit Can

Journal of NeuroInterventional Surgery | May 31, 2023 | Volume: 16 | Issue: 2 | Pages: 163-170

10.1136/jnis-2023-020360 Get It

Background Risks and benefits of intravenous thrombolysis (IVT) in patients undergoing mechanical thrombectomy (MT) have been a topic of interest. However, IVT’s specific effects on stent retriever (SR) and aspiration thrombectomy (ASP) outcomes remain largely unexplored. In this meta-analysis, we aimed to investigate the effects of IVT on SR and ASP thrombectomy outcomes. Methods In accordance with PRISMA guidelines, a systematic literature review was conducted using Medline, Embase, Scopus, Web of Science, and Cochrane Center of Clinical Trials databases. Outcomes of interest included successful recanalization (modified Thrombolysis In Cerebral Infarction (mTICI) ≥2b), modified first pass efficacy (mFPE), functional independence (modified Rankin Scale (mRS) ≤2), symptomatic intracranial hemorrhage (sICH), and embolization to new territories (ENT). Results Four randomized controlled trials with 1176 patients were included. SR and ASP resulted in similar mTICI ≥2b, mFPE, and mRS 0–2 rates in patients with and without IVT administration. SR without IVT was associated with a significantly lower rate of mFPE compared with the SR+IVT (RR 0.85, 95% CI 0.74 to 0.97). Furthermore, ASP without IVT resulted in a lower rate of mRS 0–2 than the ASP+IVT with a strong trend towards significance (RR 0.78, 95% CI 0.60 to 1.01). Finally, bridging therapy did not increase sICH and ENT rates after ASP or SR thrombectomy. Conclusions Our findings suggest that SR and ASP thrombectomy have comparable safety and efficacy profiles, regardless of prior IVT administration. Additionally, our results indicate that the addition of IVT may improve certain efficacy outcomes based on the employed first-line MT technique.