Back to Authors

Buckingham, Bruce A.

https://orcid.org/0000-0003-4581-4887

Mayo Clinic

Stanford Medicine

Citations 14

Continuous Glucose Monitors and Automated Insulin Dosing Systems in the Hospital Consensus Guideline
Galindo, Rodolfo J. , Rushakoff, Robert J , Basu, Ananda , Lohnes, Suzanne, Nichols, James H. , Spanakis, Elias K. , Espinoza, Juan , Palermo, Nadine E. , Awadjie, Dessa Garnett, Bak, Leigh B., Buckingham, Bruce A. , Freckmann, Guido , Hovorka, Roman , Mathioudakis, Nestoras , Newman, Tonya, O’Neal, David N. , Rickert, Michaela , Wallia, Amisha , Shang, Trisha , Zhang, Jennifer Y. , Han, Julia , Klonoff, David C. , Nichols, James H , Spanakis, Elias K , Espinoza, Juan , Cook, Curtiss B. , Freckmann, Guido , Heinemann, Lutz , O'Neal, David N , Sacks, David B , Shang, Trisha , Zhang, Jennifer Y , Klonoff, David C , Galindo, Rodolfo J , Hovorka, Roman , Mathioudakis, Nestoras N , Buckingham, Bruce , Umpierrez, Guillermo E. , Heinemann, Lutz , Seley, Jane Jeffrie

Journal of Diabetes Science and Technology | September 28, 2020 | Volume: 14 | Issue: 6 | Pages: 1035-1064

10.1177/1932296820954163 Get It

This article is the work product of the Continuous Glucose Monitor and Automated Insulin Dosing Systems in the Hospital Consensus Guideline Panel, which was organized by Diabetes Technology Society and met virtually on April 23, 2020. The guideline panel consisted of 24 international experts in the use of continuous glucose monitors (CGMs) and automated insulin dosing (AID) systems representing adult endocrinology, pediatric endocrinology, obstetrics and gynecology, advanced practice nursing, diabetes care and education, clinical chemistry, bioengineering, and product liability law. The panelists reviewed the medical literature pertaining to five topics: (1) continuation of home CGMs after hospitalization, (2) initiation of CGMs in the hospital, (3) continuation of AID systems in the hospital, (4) logistics and hands-on care of hospitalized patients using CGMs and AID systems, and (5) data management of CGMs and AID systems in the hospital. The panelists then developed three types of recommendations for each topic, including clinical practice (to use the technology optimally), research (to improve the safety and effectiveness of the technology), and hospital policies (to build an environment for facilitating use of these devices) for each of the five topics. The panelists voted on 78 proposed recommendations. Based on the panel vote, 77 recommendations were classified as either strong or mild. One recommendation failed to reach consensus. Additional research is needed on CGMs and AID systems in the hospital setting regarding device accuracy, practices for deployment, data management, and achievable outcomes. This guideline is intended to support these technologies for the management of hospitalized patients with diabetes.
Glycemic Outcomes of Use of CLC Versus PLGS in Type 1 Diabetes: A Randomized Controlled Trial
Brown, Sue A. , Beck, Roy W. , Raghinaru, Dan, Buckingham, Bruce A. , Laffel, Lori M. , Kudva, Yogish C. , Pinsker, Jordan E. , Dassau, Eyal , Ambler-Osborn, Louise, Anderson, Stacey M. , Church, Mei Mei , Ekhlaspour, Laya , Forlenza, Gregory P. , Levister, Camilla, Simha, Vinaya , Breton, Marc D. , Kollman, Craig, Lum, John W. , Kovatchev, Boris , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Gondor-Fredrick, Linda, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Isganaitis, Elvira , Flint, Emily, Kim, Kenny, Roethke, Lindsay, André, Camille , Piper, Molly, Lam, David W. , O’Malley, Grenye , Ogyaadu, Selassie, Lovett, Jessica, Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Slover, Robert H., Jost, Emily , Berget, Cari , Towers, Lindsey, Rossick-Solis, Alex, Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Passman, Samantha, Campos, Tiffany, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreza-Rubin, Guillermo, Eggerman, Thomas L., Green, Neal, Reznik, Yves , Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Legault, Laurent , Wysham, Carol , Kudva, Yogish C. , Pinsker, Jordan E , Dassau, Eyal , Doyle, Francis J , Ekhlaspour, Laya , Forlenza, Gregory P , Breton, Marc D , Lum, John , Kovatchev, Boris , Buckingham, Bruce , Beck, Roy W , Wadwa, R Paul , Levy, Carol J. , Doyle, Francis J. , Kollman, Craig , Oliveri, Mary Clancy , Kumari, Kanchan , Alonso, G. Todd , Messer, Laurel H , Renard, Eric , Cobelli, Claudio , Green, Jennifer Greif , Willi, Steven Matthew

Diabetes Care | May 30, 2020 | Volume: 43 | Issue: 8 | Pages: 1822-1828

10.2337/dc20-0124 Get It

OBJECTIVE Limited information is available about glycemic outcomes with a closed-loop control (CLC) system compared with a predictive low-glucose suspend (PLGS) system. RESEARCH DESIGN AND METHODS After 6 months of use of a CLC system in a randomized trial, 109 participants with type 1 diabetes (age range, 14–72 years; mean HbA1c, 7.1% [54 mmol/mol]) were randomly assigned to CLC (N = 54, Control-IQ) or PLGS (N = 55, Basal-IQ) groups for 3 months. The primary outcome was continuous glucose monitor (CGM)-measured time in range (TIR) for 70–180 mg/dL. Baseline CGM metrics were computed from the last 3 months of the preceding study. RESULTS All 109 participants completed the study. Mean ± SD TIR was 71.1 ± 11.2% at baseline and 67.6 ± 12.6% using intention-to-treat analysis (69.1 ± 12.2% using per-protocol analysis excluding periods of study-wide suspension of device use) over 13 weeks on CLC vs. 70.0 ± 13.6% and 60.4 ± 17.1% on PLGS (difference = 5.9%; 95% CI 3.6%, 8.3%; P < 0.001). Time >180 mg/dL was lower in the CLC group than PLGS group (difference = −6.0%; 95% CI −8.4%, −3.7%; P < 0.001) while time <54 mg/dL was similar (0.04%; 95% CI −0.05%, 0.13%; P = 0.41). HbA1c after 13 weeks was lower on CLC than PLGS (7.2% [55 mmol/mol] vs. 7.5% [56 mmol/mol], difference −0.34% [−3.7 mmol/mol]; 95% CI −0.57% [−6.2 mmol/mol], −0.11% [1.2 mmol/mol]; P = 0.0035). CONCLUSIONS Following 6 months of CLC, switching to PLGS reduced TIR and increased HbA1c toward their pre-CLC values, while hypoglycemia remained similarly reduced with both CLC and PLGS.
Randomized Controlled Trial of Mobile Closed-Loop Control
Kovatchev, Boris , Anderson, Stacey M. , Raghinaru, Dan, Kudva, Yogish C. , Laffel, Lori M. , Pinsker, Jordan E. , Buckingham, Bruce A. , Doyle, Francis J. , Brown, Sue A. , Church, Mei Mei , Dadlani, Vikash, Dassau, Eyal , Ekhlaspour, Laya , Forlenza, Gregory P. , Isganaitis, Elvira , Lam, David W. , Lum, John W. , Group, iDCL Study, Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Ambler-Osborn, Louise, Flint, Emily, Schultz, Alan , Kim, Kenny, Church, Mei Mei, André, Camille , Lam, David W., O’Malley, Grenye , Levister, Camilla, Ogyaadu, Selassie, Simha, Vinaya , McCrady-Spitzer, Shelly , Reid, Corey, Jost, Emily , Berget, Cari , Towers, Lindsey, Buckingham, Bruce, Ekhlaspour, Laya, Hsu, Liana, Loebner, Sarah E., Doyle, Francis J., Campos, Tiffany, Passman, Samantha, Murphy, Carlos, Patibandla, Nandan, Kollman, Craig, Pinsker, Jordan E , Doyle, Francis J , Dassau, Eyal , Ekhlaspour, Laya , Forlenza, Gregory P , Lum, John , Kovatchev, Boris , Buckingham, Bruce , Levy, Carol J. , Wadwa, R Paul , Beck, Roy W. , Group, iDCL Study, Oliveri, Mary Clancy , Church, Mei Mei, Lam, David W., Messer, Laurel H , Buckingham, Bruce, Ekhlaspour, Laya, Doyle, Francis J., Kollman, Craig

Diabetes Care | January 15, 2020 | Volume: 43 | Issue: 3 | Pages: 607-615

10.2337/dc19-1310 Get It

OBJECTIVE Assess the efficacy of inControl AP, a mobile closed-loop control (CLC) system. RESEARCH DESIGN AND METHODS This protocol, NCT02985866, is a 3-month parallel-group, multicenter, randomized unblinded trial designed to compare mobile CLC with sensor-augmented pump (SAP) therapy. Eligibility criteria were type 1 diabetes for at least 1 year, use of insulin pumps for at least 6 months, age ≥14 years, and baseline HbA1c <10.5% (91 mmol/mol). The study was designed to assess two coprimary outcomes: superiority of CLC over SAP in continuous glucose monitor (CGM)–measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L. RESULTS Between November 2017 and May 2018, 127 participants were randomly assigned 1:1 to CLC (n = 65) versus SAP (n = 62); 125 participants completed the study. CGM time below 3.9 mmol/L was 5.0% at baseline and 2.4% during follow-up in the CLC group vs. 4.7% and 4.0%, respectively, in the SAP group (mean difference −1.7% [95% CI −2.4, −1.0]; P < 0.0001 for superiority). CGM time above 10 mmol/L was 40% at baseline and 34% during follow-up in the CLC group vs. 43% and 39%, respectively, in the SAP group (mean difference −3.0% [95% CI −6.1, 0.1]; P < 0.0001 for noninferiority). One severe hypoglycemic event occurred in the CLC group, which was unrelated to the study device. CONCLUSIONS In meeting its coprimary end points, superiority of CLC over SAP in CGM-measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L, the study has demonstrated that mobile CLC is feasible and could offer certain usability advantages over embedded systems, provided the connectivity between system components is stable.