Citations

Mayo Clinic

Clear

758 citation(s) found for "Lake, DF".

Core‐binding factor acute myeloid leukemia with t(8;21): Risk factors and a novel scoring system (I‐CBFit)
Üstün, Celalettin , Pullarkat, Sheeja T. , Yeung, Cecilia C.S. , Broesby‐Olsen, Sigurd , Ohgami, Robert S. , Kim, Young , Vestergaard, Hanne , Chen, Dong , Kluin, Philip M., Dolan, Michelle, Mrózek, Krzysztof , Czuchlewski, David R., Horny, Hans‐Peter, George, Tracy I. , Kristensen, Thomas Kielsgaard , Ku, Nam K., Yi, Cecilia Arana , Møller, Michael , Marcucci, Guido , Hilberink, Jacobien R. , Pullarkat, Vinod , Shanley, Ryan , Kohlschmidt, Jessica, Coulombe, Janie , Salhotra, Amandeep , Soma, Lori , Cho, Christina , Hoermann, Gregor , Nakamura, Ryo , Deeg, Joachim, Bloomfield, Clara D. , Weisdorf, Daniel J. , Litzow, Mark R. , Valent, Peter , Huls, Gerwin , Yeung, Cecilia , Baughn, Linda, Chen, Dong , Møller, Michael Boe , Weisdorf, Dan , George, Tracy I , Arana Yi, Cecilia , Valent, Peter , Morgan, Elizabeth A. , Moodie, Erica E. M. , Sperr, Wolfgang R. , Baughn, Linda B. , Schiefer, Ana-Iris , Linden, Michael A. , Akin, Cem , Gotlib, Jason , Hornick, Jason L. , Nakamura, Ryo, Perales, Miguel‐Angel , Borthakur, Gautam

Cancer Medicine | August 17, 2018 | Volume: 7 | Issue: 9 | Pages: 4447-4455

10.1002/cam4.1733 | PMID 30117318 Get It

AbstractBackgroundAlthough the prognosis of core‐binding factor (CBF) acute myeloid leukemia (AML) is better than other subtypes of AML, 30% of patients still relapse and may require allogeneic hematopoietic cell transplantation (alloHCT). However, there is no validated widely accepted scoring system to predict patient subsets with higher risk of relapse.MethodsEleven centers in the US and Europe evaluated 247 patients with t(8;21)(q22;q22).ResultsComplete remission (CR) rate was high (92.7%), yet relapse occurred in 27.1% of patients. A total of 24.7% of patients received alloHCT. The median disease‐free (DFS) and overall (OS) survival were 20.8 and 31.2 months, respectively. Age, KIT D816V mutated (11.3%) or nontested (36.4%) compared with KIT D816V wild type (52.5%), high white blood cell counts (WBC), and pseudodiploidy compared with hyper‐ or hypodiploidy were included in a scoring system (named I‐CBFit). DFS rate at 2 years was 76% for patients with a low‐risk I‐CBFit score compared with 36% for those with a high‐risk I‐CBFit score (P < 0.0001). Low‐ vs high‐risk OS at 2 years was 89% vs 51% (P < 0.0001).ConclusionsI‐CBFit composed of readily available risk factors can be useful to tailor the therapy of patients, especially for whom alloHCT is not need in CR1 (ie, patients with a low‐risk I‐CBFit score).
Waveguide effects and implications for cardiac magnetic resonance elastography: A finite element study
Manduca, Armando , Rossman, Timothy, Lake, David S. , Glaser, Kevin J. , Arani, Arvin , Rossman, Phillip J. , Trzasko, Joshua D. , Dragomir‐Daescu, Dan , Araoz, Philip A. , Manduca, A , Arunachalam, S P , Arani, Arvin , Arunachalam, Shivaram P. , Ehman, Richard L.

NMR in Biomedicine | August 13, 2018 | Volume: 31 | Issue: 10 | Pages: No page available

10.1002/nbm.3996 | PMID 30101999 Get It

Magnetic resonance elastography (MRE) is increasingly being applied to thin or small structures in which wave propagation is dominated by waveguide effects, which can substantially bias stiffness results with common processing approaches. The purpose of this work was to investigate the importance of such biases and artifacts on MRE inversion results in: (i) various idealized 2D and 3D geometries with one or more dimensions that are small relative to the shear wavelength; and (ii) a realistic cardiac geometry. Finite element models were created using simple 2D geometries as well as a simplified and a realistic 3D cardiac geometry, and simulated displacements acquired by MRE from harmonic excitations from 60 to 220 Hz across a range of frequencies. The displacement wave fields were inverted with direct inversion of the Helmholtz equation with and without the application of bandpass filtering and/or the curl operator to the displacement field. In all geometries considered, and at all frequencies considered, strong biases and artifacts were present in inversion results when the curl operator was not applied. Bandpass filtering without the curl was not sufficient to yield accurate recovery. In the 3D geometries, strong biases and artifacts were present in 2D inversions even when the curl was applied, while only 3D inversions with application of the curl yielded accurate recovery of the complex shear modulus. These results establish that taking the curl of the wave field and performing a full 3D inversion are both necessary steps for accurate estimation of the shear modulus both in simple thin‐walled or small structures and in a realistic cardiac geometry when using simple inversions that neglect the hydrostatic pressure term. In practice, sufficient wave amplitude, signal‐to‐noise ratio, and resolution will be required to achieve accurate results.
A Systematic Overview of Zoonotic Helminth Infections in North America
Mathison, Blaine A. , Pritt, Bobbi S. , Pritt, Bobbi S , Mathison, Blaine A

Laboratory Medicine | June 20, 2018 | Volume: 49 | Issue: 4 | Pages: e61-e93

10.1093/labmed/lmy029 | PMID 30032297 Get It

AMIA’s code of professional and ethical conduct 2018
Petersen, Carolyn , Embí, Peter J. , Hollis, Kate Fultz , Koppel, Ross , Lehmann, Christoph U. , Maulden, Sarah A., McGregor, Kyle A. , Terrazas, Enrique, Winkelstein, Peter , Fultz Hollis, Kate , Koppel, Ross , Lehmann, Christoph U , Petersen, Carolyn , Berner, Eta S. , Goodman, Kenneth W. , Lehmann, Harold P. , Solomonides, Anthony , Subbian, Vignesh

Journal of the American Medical Informatics Association | June 18, 2018 | Volume: 25 | Issue: 11 | Pages: 1579-1582

10.1093/jamia/ocy092 | PMID 30329055 Get It

Impact of Intensive Versus Standard Blood Pressure Management by Tertiles of Blood Pressure in SPRINT (Systolic Blood Pressure Intervention Trial)
Shapiro, Brian P. , Ambrosius, Walter T. , Blackshear, Joseph L., Whelton, Paul K. , Oparil, Suzanne , Dwyer, Jamie P. , Kostis, William J. , Lioudis, Michael , Pisoni, Roberto, Rosendorff, Clive , Haley, William E. , Dwyer, Jamie P , Cushman, William C. , Beddhu, Srinivasan , Gren, Lisa H.

Hypertension | April 30, 2018 | Volume: 71 | Issue: 6 | Pages: 1064-1074

10.1161/hypertensionaha.117.10646 | PMID 29712745 Get It

Intensive systolic blood pressure (SBP) control improved outcomes in SPRINT (Systolic Blood Pressure Intervention Trial). Our objective was to expand on reported findings by analysis of baseline characteristics, primary outcomes, adverse events, follow-up blood pressure, and medication use differences by baseline SBP (tertile 1 [T1], <132; tertile 2 [T2], 132–145; and tertile 3 [T3], >145 mm Hg). Participants with higher baseline SBP tertile were more often women and older, had higher cardiovascular risk, and lower utilization of antihypertensive medications, statins, and aspirin. Achieved SBP in both treatment arms was slightly higher in T2 and T3 compared with T1 and fewer in the T3 groups achieved SBP targets compared with T1 and T2 groups. The primary composite outcome with intensive versus standard SBP treatment was reduced by 30% in T1, 23% in T2, and 17% in T3 with no evidence of an interaction ( P =0.77). Event rates were lower in the intensive arm, and there was no evidence that this benefit differed by SBP tertile. There was no difference in the hazard for serious adverse events in any of the 3 tertiles. Medication utilization differed across the SBP tertiles at baseline with a lesser percentage of diuretics and angiotensin-converting enzyme inhibitors/angiotensin receptor blocker drugs in the higher tertiles—a finding that reversed during the trial. The beneficial effects of intensive SBP lowering were not modified by the level of baseline SBP. Within the parameters of this population, these findings add support for clinicians to treat blood pressure to goal irrespective of baseline SBP.
Outcomes of Medicare-age eligible NHL patients receiving RIC allogeneic transplantation: a CIBMTR analysis
Shah, Nirav N. , Ahn, Kwang Woo , Litovich, Carlos, Fenske, Timothy S. , Ahmed, Sairah , Bejanyan, Nelli , Bolaños‐Meade, Javier , Chen, Andy I. , Ciurea, Stefan O. , Bachanová, Veronika , DeFilipp, Zachariah , Epperla, Narendranath , Farhadfar, Nosha , Herrera, Alex F. , Haverkos, Bradley M. , Holmberg, Leona , Hossain, Nasheed , Kharfan‐Dabaja, Mohamed A. , Kenkre, Vaishalee P. , Murthy, Hemant S. , Rezvani, Andrew R. , D’Souza, Anita , Ulrickson, Matthew L. , Waller, Edmund K. , Sureda, Anna , Smith, Sonali M. , Holmberg, Leona , Chen, Andy , Kharfan-Dabaja, Mohamed A., D'Souza, Anita , Bachanova, Veronika , Murthy, Hemant S , Waller, Edmund K , Epperla, Narendranath , Ahmed, Sairah , Battiwalla, Minoo , Dahi, Parastoo B , Lazarus, Hillard M. , Nishihori, Taiga , Savani, Bipin N. , Hamadani, Mehdi

Blood Advances | April 23, 2018 | Volume: 2 | Issue: 8 | Pages: 933-940

10.1182/bloodadvances.2018018531 | PMID 29685953 Get It

Key Points There was no difference in overall survival after allogeneic transplant between patients aged 55-64 years and patients ≥65 years. Age alone should not be a determinant for allogeneic transplant eligibility among older non-Hodgkin lymphoma patients.
Fact Finders for Patient Safety: Are Gadolinium-Based Contrast Media Safe Alternatives to Iodinated Contrast Agents for the Safe Performance of Spinal Injection Procedures?
Popescu, Adrian, Patel, Jaymin , McCormick, Zachary L. , Maus, Timothy P. , Rodes, Meghan, Walega, David R., Smith, Clark C, McCormick, Zachary L , Smith, Clark

Pain Medicine | April 11, 2018 | Volume: 19 | Issue: 10 | Pages: 2089-2090

10.1093/pm/pny090 | PMID 29767782 Get It

Combined Pathologies in FTLD-TDP Types A and C
Gefen, Tamar , Mao, Qinwen , Kım, Garam , Seçkin, Mustafa , Bonakdarpour, Borna , Ramos, Eliana Marisa , Coppola, Giovanni , Rademakers, Rosa , Rogalskı, Emily , Rademaker, Alfred , Weıntraub, Sandra , Geula, Changiz , Bigio, Eileen H. , Ahmadian, Saman Seyed , Mesulam, Marsel M. , Mao, Qinwen

Journal of Neuropathology & Experimental Neurology | March 23, 2018 | Volume: 77 | Issue: 5 | Pages: 405-412

10.1093/jnen/nly018 | PMID 29584904 Get It

Incidence and Clinical Significance of New-Onset Device-Detected Atrial Tachyarrhythmia
Belkin, Mark N. , Soria, Cesar, Waldo, Albert L., Borleffs, C. Jan Willem, Hayes, David L. , Tung, Roderick , Upadhyay, Gaurav A. , Soria, Cesar E, Singh, Jagmeet P, Singh, Jagmeet P

Circulation: Arrhythmia and Electrophysiology | March 14, 2018 | Volume: 11 | Issue: 3 | Pages: No page available

10.1161/circep.117.005393 | PMID 29540371 Get It

Background: Despite the clear association between atrial fibrillation and risk for thromboembolic events (TEs), the clinical significance of new-onset device-detected atrial tachyarrhythmia (DDAT) and TE remains disputed. We aimed to determine the risk of TE in patients with new-onset DDAT. Methods and Results: The OVID Medline, Cochrane, and Scopus databases (inception to November 2016) were searched. Randomized controlled trials, prospective, or retrospective studies of pacemaker or defibrillator patients reporting incidence of DDAT were selected. Summary statistics were used for analysis. Of 4893 reports identified, 28 studies following 24 984 patients were included: average age 69.9 years, 34.7% women, mean study duration 21.8±18.6 months. New-onset DDAT was observed in 23% of patients. Among 9 studies (n=8181) reporting TE, the absolute incidence was 2.1%. TE risk was significantly greater among patients with new-onset DDAT (relative risk [RR], 2.88; 95% CI, 1.79–4.64; P <0.001). TE risk was correlated with DDAT duration, with an increased risk associated with DDAT ≥5 minutes (RR, 3.86; 95% CI, 2.04–7.30; P <0.001) compared with <1 minute (RR, 1.77; 95% CI, 1.15–2.74; P =0.01). Notably, the risk of TE was also increased in patients with adjudicated atrial electrograms (RR, 3.60; 95% CI, 2.06–6.30; P <0.001) compared with nonadjudicated electrograms (RR, 2.05; 95% CI, 1.06–3.97; P =0.03), even when lower mean thresholds for detection were used. Conclusions: New-onset DDAT is common, affecting close to one quarter of all patients with implanted pacemakers or defibrillators. Adjudication of atrial electrograms further identifies at-risk patients, even when relatively short detection thresholds are used.