Abstract Background Vasoactive intestinal peptide (VIP), a potent vasodilator, is produced by neuronal cells located in the central nervous system, the digestive, respiratory, and urogenital tracts, and the exocrine, thyroid, and adrenal glands. Increased circulating VIP is clinically useful to detect VIP-producing tumors in patients with chronic diarrheal diseases. Objective Develop a sensitive replacement radioimmunoassay (RIA) for VIP quantitation in human plasma due to the diminished supply of the antibody used in the previous in-house method. Method Patient VIP in EDTA plasma competes with labeled (125I) VIP for a limited number of primary rabbit polyclonal antibody (BMA Biomedicals, Augst, Switzerland) binding sites. Antibody-bound VIP is then complexed with a goat anti-rabbit secondary antibody and precipitated out of the solution with the use of polyethylene glycol and centrifugation. After the supernatant is discarded, the 125I signal from the pellet is counted on the Wizard2 gamma counter (Perkin Elmer, Waltham, MA). The measured signal is inversely proportional to the amount of VIP present in the patient’s sample. Method validation of the new assay included determination of imprecision (pooled human EDTA plasma), limits of detection and quantification, analytical measurement range (AMR), accuracy by spike recovery, interferences, cross-reactivity, stability, reference interval determination, and agreement with the current Mayo laboratory-developed assay. Results Stability studies on freshly collected EDTA plasma showed VIP is stable for 3 days ambient, 7 days refrigerated, and 14 days frozen. Intra-assay imprecision studies showed 8.3, 2.3, and 1.3%CV for mean VIP concentrations of 41, 144, and 304 pg/mL. Inter-assay imprecision was 12.9, 7.6, 5.2, and 7.5%CV for mean VIP concentrations of 30, 81, 180, and 308 pg/mL. The assay limit of detection was 29 pg/mL. The limit of quantitation was 30 pg/mL (%CV = 13%) and was established via precision profile. The AMR was 30–500 pg/mL (slope of 0.98, intercept of 3.0 pg/mL, and R2 of 0.97). The mean % spike recovery using a different preparation lot of calibrator material was 89% (range 83%–93%). The assay was not affected by up to 1000 mg/dL hemoglobin, 1000 mg/dL triglycerides, or 10 mg/dL bilirubin. Peptide histidine methionine 27, neurotensin, gastric inhibitory peptide, motilin, secretin, and glucagon do not cross-react in the assay. The 97.5th reference limit was <86 pg/mL (95% CI 81–90, n = 127). Positive percent agreement (PPA), negative percent agreement (NPA), and overall percent agreement (OPA) with the current Mayo VIP assay were 97, 82, and 90% respectively. Conclusion We have developed a replacement VIP RIA. This assay has a lower limit of quantitation and a broader AMR than the current assay. Concordance with the current assay was acceptable.
A-122 Fluid Type (STILL) Matters: An Analysis of Quality Control Material Suitability for Measuring Eleven Body Fluid Analytes in the Clinical Laboratory
Abstract Background Measuring the concentration of albumin, amylase, bilirubin, cholesterol, creatinine, glucose, lactate dehydrogenase (LDH), lipase, total protein(TP), triglycerides, and urea nitrogen(UN) in body fluids(BFs) provides important information to aid in clinical decision-making. The range of expected values of these analytes in BFs may not match serum, and the distribution by fluid type is not well described. Quality control (QC) materials are designed to reflect clinically relevant concentrations in blood. Hence, the measuring ranges for assays modified for BF testing vary in suitability. Laboratorians and manufacturers would benefit from understanding the overlap in BF and serum analyte concentrations. The aim of this study was to characterize the range of BF analyte concentrations compared to serum and assess the suitability of QC materials used on these assays. Methods A retrospective analysis was performed for the following analytes in BFs with reportable ranges(including maximum dilution factor): albumin = 0.2–12.0 g/dL(×2), amylase = 3–14 000 U/L(×100), bilirubin = 0.1–72.2 mg/dL(×2), cholesterol = 4–8000 mg/dL(×10), creatinine = 0.1–92.0 mg/dL(×4), glucose = 2–3375 mg/dL(×5), LDH = 10–9000 U/L(×10), lipase = 3–300 000 U/L(×1000), TP = 0.2–36.0 g/dL(×3), triglycerides = 4–8850 mg/dL(×10), and UN = 2–300 mg/dL(×3). Chemistry tests were run on a cobas® 6000 c501 (Roche Diagnostics,Indiana). Patient analyte concentration and fluid type results reported between 9/16/2019 and 1/27/2022 at all Mayo Clinic locations were extracted from an institutional database of electronic medical record data. Serum results were included for comparison. Descriptive statistical analyses (median and range) were performed with R (version 4.2.2)/R Studio(version 2022.12.0). QC materials for BF testing were purchased from Bio-Rad (Multilevel Qual, Levels 1 and 3; Hercules, CA, USA). Target concentrations are reported. Results Conclusion BF median (range) concentrations are similar or higher for bilirubin, creatinine, glucose, lipase, and UN. Serum QC material is likely appropriate for these assays in BFs. BF median(range) concentrations are lower for albumin, cholesterol, TP, and triglycerides suggesting that serum QC material may not be well suited for BFs. The need for extended dilutions may impact BF amylase and lipase.
A-219 A Multiplexed Targeted Assay for Gangliosides Using Liquid Chromatography-Tandem Mass Spectrometry
Abstract Background Gangliosides are a family of complex lipids that are molecules composed of glycosphingolipid with one or more sialic acid linked on the sugar moieties. Gangliosides are recognized to play an important role in many biological processes and the alterations in ganglioside profiles have been observed in some neurodegenerative diseases, neuropathies and lysosomal disorders. Gangliosidoses are a group of inherited lysosomal enzyme deficiencies characterized by an accumulation of incompletely degraded gangliosides in the lysosome. While the diagnosis of gangliosidoses can be accomplished by measurement of enzymatic activities and/or molecular genetic testing, biomarker analysis could facilitate monitoring affected patients, including those enrolled in clinical trials of new treatment approaches (ie., substrate reduction or gene therapies). We developed a rapid and sensitive LC-MS/MS assay that allows simultaneous quantification of multiple gangliosides and other glycosphingolipids and tested it in serum and plasma of patients with a diagnosis of GM2-gangliosidosis. Methods Gangliosides and other glycosphingolipids were extracted from 20 µL serum or plasma using chloroform:methanol (1:2, v/v). A multiplexed LC-MS/MS assay was developed that targeted several ganglioside species (GM3, GM2, GM1, GD3, GD2, GD1, GT3, GT2, GT1 and GQ1) along with several glycosphingolipid species (GlcCer, LacCer, Gb3, Gb4 and GA2). This assay was performed on a triple quadrupole mass spectrometer with scheduled MRM in both negative and positive ion modes after internal standards (GM3 18:0-d5, GM1 17:0, GA2 17:0 and Gb3 18:0-d3) were spiked into clinical samples. Results The multiplexed targeted assay applied to serum and plasma from controls (47 and 49 samples, respectively) and three GM2-gangliosidosis patients for identification and quantification of the targeted gangliosides and other glycosphingolipids. The abundance of GM2 and GM1 gangliosides inserum and plasma of patients with GM2-gangliosidosis was significantly higher than in the control group (P < 0.0001) whereas GM3 levels were significantly lower (P < 0.005). Other gangliosides including GD3, GD2, GD1 and GT1 and glycosphingolipids such as GlcCer, LacCer and Gb3 were not significantly different between these patients and controls. Conclusion A multiplexed targeted assay for glycosphingolipids including gangliosides was developed. This assay will be further validated for potential use in the diagnosis and monitoring of patients with additional gangliosidoses.
A-221 Evaluation of Apolipoprotein B Equivalent Low-density Lipoprotein Cholesterol Measurements
Abstract Background Low-density lipoprotein cholesterol (LDL-C) is the primary biomarker for assessing risk for atherosclerotic cardiovascular disease (ASCVD). However, multiple large studies have demonstrated greater accuracy using Apolipoprotein B (apoB). One obstacle to its widespread use is the lack of guideline endorsed apoB treatment targets. A recently published solution has proposed using population percentiles to calculate LDL-C using apoB values (PMID: 36366949). The LDL-C concentration correlated to an individual’s ApoB percentile may more appropriately reflect ASCVD risk compared to lipid panel LDL-C. Here we evaluated this approach using a cohort where LDL-C was measured with the gold-standard beta-quantification method (LDL-CBQ). Method Results from clinically ordered apoB, LDL-CBQ, and lipid panel were included (n = 18 852). Samples with triglycerides >1000 mg/dL or LpX were excluded. Total cholesterol, high-density lipoprotein cholesterol (HDL-C), triglycerides (TG), and apoB were measured using Roche Cobas c501 analyzers. LDL-CBQ was performed using Beckman LE-80K ultracentrifuge and dextran sulfate-Mg/Cl precipitation. ApoB equivalent LDL-C (eqLDL-CapoB) was calculated according to linear regression of LDL-C percentiles against apoB percentiles described by the equation eqLDL-CapoB = 1.45(apoB)-25. Concordance was determined based on clinical thresholds for LDL-CBQ and eqLDL-CapoB. Results Median (IQR) apoB and LDL-CBQ was 98 (79−119) mg/dL and 120 (94−150) mg/dL, respectively. LDL-CBQ and eqLDL-CapoB were concordant in 60% of samples overall. Discordance between eqLDL-CapoB and LDL-CBQ shifted from primarily overestimating to underestimating as LDL-CBQ increased. Discordant eqLDL-CapoB was directly associated with TG and inversely associated with HDL-C. Conclusion The eqLDL-CapoB calculation is a useful tool to present apoB results in a more familiar context of LDL-C-equivalent units. The concordance findings largely confirm previously published results using eqLDL-CapoB. Furthermore, the pattern of HDL-C and TG suggests that a discordantly elevated eqLDL-CapoB is an indicator of a higher risk lipid profile. More investigation is needed to determine if eqLDL-CapoB is appropriate for widespread adoption.
A-373 Comparison of the CoaguChek ® and Coag-Sense ® PT2 Meter Point of Care INR Devices
Abstract Background Warfarin monitoring may be done at the point-of-care (POC) at home, in a clinic environment, or be performed using plasma specimens in a central laboratory. With a goal of standardizing International Normalization Ratio (INR) measurements and improving data integrity by enabling electronic transmission of results from any location, we evaluated two POC INR devices against an internal plasma INR reference method. Methods We conducted a multicenter study to test the accuracy of two commercially available point of care devices: Coag-Sense PT2 Meter (Coagusense, Inc., Fremont, CA) and CoaguChek XS Pro or XS Plus (Roche Diagnostics, Indianapolis, IN) compared with plasma INR values among warfarin treated patients. Bias and linear regression analysis were assessed for device-plasma INR comparisons. Warfarin dosing decisions were assessed for each device compared to an internal plasma INR reference method (Instrumentation Laboratories ACLTOP 500, 550, 750 analyzers (Werfen Diagnostics, Bedford MA) in one of three CLIA-certified laboratories. The thromboplastin used at our institution for INR measures is HemosIL RecombiPlasTin 2G (R2G) reagent (Werfen Diagnostics, Bedford MA) which has an International Sensitivity Index (ISI) of 1.0. Results Two hundred ninety-nine warfarin patients treated across three Mayo Clinic sites agreed to participate in the study. Common anticoagulant indications were atrial fibrillation (63.9%), venous thromboembolism (21.7%) and heart valve prosthesis (15.4%) with a 2.0–3.0 INR target range for 93.6% of patients. For the CoaguChek devices, 81.3% of values fell within 0.2 INR units of plasma INR referent and 95.3% within 0.4 units. The correlation between CoaguChek whole blood and plasma INR was excellent (R2 = 0.93). For the Coag-Sense device, 34.1% of values fell within 0.2 INR units and 60.2% within 0.4 INR units of plasma INR values, with a slightly weaker correlation between Coag-Sense whole blood and plasma INR (R2 = 0.83; P < 0.0001). Mean (± standard deviation) deviation from plasma INR was 0.04 ± 0.2 for CoaguChek compared to 0.4 ± 0.3 for Coag-Sense (P < 0.0001). The difference between POC devices was largely attributed to systematic negative bias between Coag-Sense and ACL TOP plasma INR values. Using the plasma INR as the reference method for dosing decision making, appropriate dosing recommendations would have occurred for 97.7% of CoaguChek and 81.6% of Coag-Sense results. Conclusion Compared to our institution's plasma reference method, INR values obtained from the CoaguChek devices (XS Pro and XS Plus) exhibited less systematic bias compared to the Coag-Sense values. This translates to greater percentage of concordant management decisions between POC and laboratory plasma INR methods when the CoaguChek device is used.
B-044 Analytical validation of an serum glycerol measured by nuclear magnetic resonance spectroscopy NMR
Abstract Background Glycerol kinase deficiency (GKD) is a rare X-linked recessive disorder biochemically characterized by hyperglycerolaemia. Adults with GKD are usually asymptomatic. However, they often present with pseudohypertriglyceridemia because most clinical triglyceride methods measure enzymatically generated glycerol from triglycerides. Currently, assays for measuring plasma glycerol are lacking. We describe a preliminary validation of glycerol measured by nuclear magnetic resonance spectroscopy (NMR). Methods Serum glycerol was measured by NMR (Numares AG, Regensberg, Germany) using a Ascend 600 NMR (Bruker, Billerica, MA). Stability and matrix effects were determined by repeat measurement of 10 freshly collected samples following various storage conditions. Normal donors were recruited for reference interval (n = 143). Analytical specificity was assessed by spiking red cell lysate, bilirubin and intralipid. Precision was assessed by measuring three pools five times for five days. Accuracy was performed by spiking known concentrations of glycerol. Accuracy was assessed using an enzymatic method (Randox Laboratories, Ltd. County Antrim, UK) on a Roche Cobas c501 (Roche Diagnostics, Indianapolis, IN) as reference. Results Measured glycerol increased over time in both serum and plasma, however, prepared samples were stable on the instrument for up to 24 hours. Measured glycerol was not impacted by hemoglobin (1000 mg/dL) or bilirubin (625 mg/dL), however, spiking Intralipid® prevented any measurement. NMR and enzymatic assays strongly correlated, with a constant bias (Table 1). Repeatability and reproducibility were <10% CV and % recovery from glycerol standard were >80% for all concentrations. Conclusion Pre-analytical stability, imprecision and accuracy were acceptable for clinical measurement of glycerol using NMR. While there is a significant systematic bias with enzymatic methods, further studies in normal and disease populations will be necessary to determine clinical impact.
A-127 Bias and Precision of a NMR-based GFR Estimating Equation in Kidney Transplant Recipients
Abstract Background An accurate and reliable measurement of glomerular filtration rate (GFR) is essential to monitor for rejection and disease progression post-kidney transplantation. Measured GFR (mGFR) is the current gold standard. However, it has scarce availability at many centers and is labor intensive. Newer estimated GFR (eGFR) methods containing cystatin-C and/or other biomarkers have not been clinically validated in a post-transplant cohort. In this study, we evaluated a new NMR-based GFR (GFRNMR) equation that contains serum creatinine, cystatin C, myoinositol, and valine in post-kidney transplant recipients in a clinical routine setting. Methods Venipuncture for serum collection was performed immediately prior to mGFR measurement with urinary iothalamate clearance in 67 post-kidney transplant recipients. Serum was stored at 4°C and measured by NMR no later than four days after collection. eGFR was assessed using the following equations: i) GFRNMR, ii) CKD-EPI2021Cr (creatinine) and iii) CKD-EPI2021Cr,Cys (creatinine and cystatin-C). Bias was calculated as “eGFR—mGFR” for all equations. The Bootstrap method was employed to assess pairwise significance levels between bias distributions interquartile ranges (IQR), and P-value correction was determined with the Benjamini & Hochberg method. Precision, which was defined as percentage of samples within ±30% and ±15% from the mGFR value (P30 and P15, respectively), was calculated for each equation. Pairwise comparisons were made using McNemar’s Chi-squared and Benjamini & Hochberg correction. Precision was defined as the proportion of eGFR values concordant with mGFR values by CKD clinical stage. Results P30 for GFRNMR was significantly higher than CKD-EPI2021 Cr,Cys (97% vs 84%, P < 0.01) and higher than CKD-EPI2021 Cr (88%, P = 0.08). Similarly, P15 for GFRNMR was 63%; higher than for CKD-EPI2021 Cr (54%, P = 0.35) and CKD-EPI2021 Cr,Cys (51%, P = 0.19). Bias IQR for GFRNMR was 9.5 mL/min/1.73 m2 (median bias 2.0 mL/min/1.73 m2); significantly smaller than for CKD-EPI2021 Cr (Bias IQR 15.55 mL/min/1.73 m2, P < 0.05; median bias 1.47 mL/min/1.73 m2), and smaller than CKD-EPI2021 Cr,Cys (Bias IQR 14.4 mL/min/1.73 m2, P = 0.09; median bias 2.3 mL/min/1.73 m2). A broad range of medications such as immune modulators, and comorbidities such as hypertension, thyroid dysfunction, and coronary artery disease, did not interfere with GFRNMR performance. Conclusion NMR-based eGFR was less biased, more precise, and more accurate compared to creatinine and cystatin-C CKD-EPI eGFR equations in a post-kidney transplant setting. These findings suggest GFRNMR may more closely resemble mGFR in post-transplant patients and warrants further study on its potential use to improve clinical management in this patient group.
A-203 An Equation based on the Standard Lipid Panel for Calculating Low-Density Lipoproteins-Triglycerides
Abstract Background There is growing evidence that low-density lipoprotein-triglyceride (LDL-TG) may be a better biomarker to define atherosclerotic cardiovascular disease (ASCVD) risk than LDL-cholesterol (LDL-C), which is currently used to stratify risk and as a treatment goal. Because LDL-TG typically requires additional advanced lipid testing, we developed an equation for estimating LDL-TG (eLDL-TG) from the results of the standard lipid panel. Methods Results from a general dyslipidemic population (N = 40 202), which were obtained with beta-quantification (BQ) reference method, were randomly divided into a training and validation datasets and used to develop the equation for estimating LDL-TG shown in Fig. 1A. Association of Sampson-NIH-LDL-C (NIH-LDL-C) and eLDL-TG with ASCVD risk markers was done in the National Heart and Nutrition Examination Survey (NHANES) (N = 37 053) and with ASCVD events in the Atherosclerosis Risk in Communities (ARIC) study (N = 14 749). Results The comparison between eLDL-TG and measured LDL-TG was only modest (R2 = 0.601, slope = 0.611), but eLDL-TG (Fig. 1B) showed better risk stratification than NIH-LDL-C (Fig. 1C) by survival curve analysis in ARIC. Moreover, receiver-operating characteristic (ROC) analysis showed that eLDL-TG was better than all other lipid-marker tests for ASCVD events (AUC: eLDL-TG = 0.633, HDL-C = 0.627, sdLDL-C = 0.621, remnant-cholesterol = 0.613, NonHDL-C = 0.613, TG = 0.603, apoB = 0.598, NIH-LDL-C = 0.590, TC = 0.568). In NHANES, eLDL-TG was more strongly associated with hypertriglyceridemia, obesity, diabetes, metabolic syndrome and increased high-sensitivity C-reactive protein than NIH-LDL-C. Inclusion of eLDL-TG in a Cox-Proportional Hazards Model along with other conventional risk factors (age, sex, race, diabetes, systolic blood pressure, smoking, HDL-C, and total cholesterol) did not further improve risk prediction. Conclusions Like LDL-C, LDL-TG can also be estimated from the results of the standard lipid panel. It is a better univariate risk marker than LDL-C and hence can be useful for initial ASCVD risk stratification.
B-095 Determination of Error Rates with Duplicate Analysis in Anti-Drug Antibody Testing
Abstract Background Duplicate measurements can be used to characterize assay imprecision, identify outliers, and estimate error rates. The benefits of duplicate analysis, however, need to be balanced against the increased financial cost. The objective of this study was to evaluate the need for continued replicate measurement in a laboratory developed assay measuring anti-drug antibodies to infliximab (ATI). To this end, duplicate patient sample measurements from the ATI assay over a two-year period were analyzed to calculate outlier and error frequencies. Methods ATI were measured by electrochemiluminescence (ECL) on the MesoScale Discovery (MSD) platform, with a standard curve from 20–1250 U/mL using commercially available monoclonal ATIs. All patient samples tested for ATI over a 27-month period of time (n = 9582) were subject to inclusion in this study. Only patient samples with ATI levels within the analytical measuring range (AMR) of the assay, however, were selected for further analysis. Samples were divided equally into 7 bins across the measuring range based on mean replicate concentration. Within-run imprecision was determined for each bin using the standard deviation (combined from all replicates using sum of squares) and mean concentration derived from all replicates. Outliers were defined as replicate measurements with a percent difference greater than ±3 SD of the calculated assay imprecision. Errors were defined as samples which had replicate values on opposite sides of the clinical cutoff of positive ATI (≥50 U/mL) and a percent difference greater than 3SD of the assay imprecision. Results Of the 9582 total patient samples analyzed, 2467 had ATI values within the AMR and 1655 had levels over the clinical cut-off of 50 U/mL (17.3% positivity rate). Within-run imprecision determined from the mean and combined SD of the duplicate measurements ranged from 15.7% at the lowest concentration bin (20–27.5 U/mL) to 10.0% at the highest concentration bin (358–1243 U/mL). The mean percentage of outliers in each bin ranged from 0.8%–3.4% resulting in an overall outlier frequency of 2.1% when considering all samples within the AMR. There were 66 samples within the AMR which demonstrated qualitative discrepancies between the replicates. However, only 21 (31.8%) of these samples, had a percent agreement greater than 3SD of the assay imprecision resulting in an overall error rate of 0.2% when considering all 9582 samples. Conclusion In this study, the analysis of replicate patient samples enabled the establishment of a precision profile and estimation of error rates for a laboratory developed test measuring ATI. The calculated error rate of 0.2%, however, is well within the reported range of most clinical assays indicating that the continued practice of duplicate measurement may not be necessary. Additionally, updating the laboratory protocol to eliminate replicate testing would have positive impact in laboratory workflow, cost, and turn-around-time for results.
A-123 Increased Rate of Recurrent Hemolysis Is Associated With COVID-19 Infection and Propofol Administration in the Intensive Care Unit (ICU)
Abstract Background Hemolysis is a pre-analytic issue that challenges clinical laboratories. When a specimen with significant hemolysis is obtained in our laboratory, tests where the hemolysis threshold is exceeded are not reported and blood is recollected. Unfortunately, in a subset of patients, the recollected specimen is also hemolyzed (termed “recurrent hemolysis”). In these cases, the second recollection utilizes special collection and handling protocols (i.e., hand-carried to lab, plasma collection, etc.) to mitigate preventable causes of hemolysis. Lipemia is also a known contributor to specimen hemolysis. Mayo Clinic Rochester experienced an increased rate of hemolysis as well as recurrent hemolysis during the height of the COVID-19 pandemic (January 2022). The objective of this study was to investigate the increased rate of recurrent hemolysis and compare to a rate prior to the COVID-19 pandemic (January 2019). Methods Retrospective data analysis was performed for January 2019 (negative control) and January 2022. The number of Mayo Clinic Rochester hospital admissions, admitting diagnosis, medications administered, and number of test collections performed were obtained using reporting functionality in our Electronic Health Record (EHR), Epic. The Laboratory Information System, SoftLab, was utilized to obtain recollection rates due to hemolysis. Data were normalized to total patient admissions for the specified period to account for inter-year variability. R/R Studio was utilized to analyze and visualize the data. Pearson’s Chi-squared test for independence was performed on categorical variables (significance defined as P < 0.05). Results A 28% decrease in hospital admissions (n = 3958:Jan-22 vs n = 5517:Jan-19) and a 23% decrease in total specimens collected on hospitalized patients (n = 40 557:Jan-22 vs n = 52 373:Jan-19) was observed between Jan-19 to Jan-22. However, the laboratory observed a 6% increase in hemolyzed specimens (n = 256:Jan-22 vs n = 241:Jan-19). Recurrent hemolysis occurred in 24% (n = 62/256) of Jan-22 and 17% (n = 43/241) of Jan-19 hemolyzed specimens and required special handling protocols. COVID positive patients comprised 48% (n = 30/62) of those requiring special handling protocols in Jan-22. Further examination revealed 34% (n = 21/62) of Jan-22 and 12% (n = 5/43) of Jan-19 cases of recurrent hemolysis were due to lipemia (P < 0.01). Chart review highlighted a potential source of lipemia from the administration of propofol, a lipophilic sedative emulsion. Of those COVID positive cases with recurrent hemolysis due to lipemia (n = 15/30), 93% (n = 14/15) were receiving propofol at the time of collection (P < 0.001). Conclusion We observed increased rates of specimen hemolysis during the COVID-19 pandemic. While most hemolysis resolves upon specimen recollection, patients with recurrently hemolyzed specimens often require special specimen collection and handling protocols to mitigate hemolysis. Approximately half of the recurrent hemolysis cases in Jan 2022 were COVID-19 positive patients. Lipemia-induced hemolysis was also more frequent in this patient population presumably due to the administration of propofol, a lipophilic emulsion sedative commonly used for COVID positive patients requiring sedation and ICU-level care. It is critical to understand the variety of factors which may contribute to recurrent hemolysis, as intervening with specialized collection and handling protocols to reduce observed pre-analytical hemolysis is required to provide accurate and timely laboratory results.