Citations

Mayo Clinic

Clear

31 citation(s) found for "Lynne, Sloan".

Comparison of Two Commercial Molecular Assays to a Laboratory-Developed Molecular Assay for Diagnosis of Clostridium difficile Infection
Karre, Tess, Sloan, Lynne M., Patel, Robin , Mandrekar, Jayawant N. , Rosenblatt, Jon E., Patel, Robin

Journal of Clinical Microbiology | December 2, 2010 | Volume: 49 | Issue: 2 | Pages: 725-727

10.1128/jcm.01028-10 | PMID 21123537 Get It

ABSTRACT We compared two commercial PCR assays, the Prodesse ProGastro CD assay and the BD GeneOhm Cdiff assay, with a laboratory-developed Clostridium difficile toxin PCR assay with previously established performance characteristics. Results of all methods were in agreement for 333 (96%) of 346 stool specimens. No significant difference in performance among the assays was found ( P values, >0.05).
Three-Hour Molecular Detection of Campylobacter , Salmonella , Yersinia , and Shigella Species in Feces with Accuracy as High as Tha
Cunningham, Scott A. , Sloan, Lynne M., Nyre, Lisa M., Vetter, Emily A., Mandrekar, Jayawant N. , Patel, Robin , Patel, Robin , Cunningham, Scott A

Journal of Clinical Microbiology | June 3, 2010 | Volume: 48 | Issue: 8 | Pages: 2929-2933

10.1128/jcm.00339-10 | PMID 20519461 Get It

ABSTRACT Campylobacter jejuni and Salmonella , Shigella , and Yersinia species (along with Shiga toxin-producing Escherichia coli ) are the most common causes of acute bacterial diarrheal disease in the United States. Current detection techniques are time-consuming, limiting usefulness for patient care. We developed and validated a panel of rapid PCR assays for the detection and identification of C. jejuni , C. coli , Salmonella , and Yersinia species and Shigella and enteroinvasive E. coli in stool samples. A total of 392 archived stool specimens, previously cultured for enteric pathogens, were evaluated by PCR. Overall, 104 stool specimens had been culture positive ( C. jejuni / coli [ n = 51], Salmonella species [ n = 42], Shigella species [ n = 6], and Yersinia species [ n = 5]). Compared to culture, the overall sensitivity and specificity of PCR detection of these organisms were 92 and 98% (96/104 and 283/288), respectively, from fresh or Cary Blair stool ( P = 0.41); 87 and 98% (41/47 and 242/246), respectively, from fresh stool ( P = 0.53); and 96 and 98% (55/57 and 41/42), respectively, from Cary Blair stool ( P = 0.56). For individual genera, PCR was as sensitive as the culture method, with the exception of Salmonella culture using selenite enrichment for which PCR was less sensitive than culture from fresh, but not Cary Blair ( P = 0.03 and 1.00, respectively) stools. This PCR assay panel for the rapid diagnosis of acute infectious bacterial diarrheal pathogens has a sensitivity and specificity equivalent to that of culture for stools in Cary Blair transport medium. Paired with reflexive culture of stools testing positive, this should provide an improvement in care for patients with acute infectious diarrheal disease.
Rapid and Sensitive Detection of Shiga Toxin-Producing Escherichia coli from Nonenriched Stool Specimens by Real-Time PCR in Comparison to Enzyme Immunoassay and Culture
Grys, Thomas E. , Sloan, Lynne M., Rosenblatt, Jon E., Patel, Robin , Patel, Robin , Grys, Thomas E

Journal of Clinical Microbiology | May 14, 2009 | Volume: 47 | Issue: 7 | Pages: 2008-2012

10.1128/jcm.02013-08 | PMID 19439539 Get It

ABSTRACT Shiga toxin (Stx)-producing Escherichia coli (STEC) bacteria are a frequent cause of food-borne gastroenteritis, hemorrhagic colitis, and hemolytic uremic syndrome. Because antimicrobial agents are generally contraindicated in patients infected with STEC, a sensitive and specific diagnostic test with rapid turnaround is essential. Current culture methods may fail to detect non-O157 STEC. We evaluated a Stx gene real-time PCR assay using hybridization probes and the LightCycler instrument with 204 prospectively collected stool specimens, which were also tested for Stx by enzyme immunoassay (EIA) (ProSpecT STEC; Remel, Lenexa, KS) and by culturing on chromogenic agar (Chromagar O157; BD BBL, Sparks, MD). In addition, 85 archived stool specimens previously tested for Stx (by EIA) and/or E. coli O157:H7 (by culture) were tested by PCR. Sample preparation for PCR included mixing the stool in sterile water and extraction of nucleic acid using the MagNA Pure LC instrument (Roche Diagnostics). The PCR assay had 100% sensitivity and specificity compared to EIA and culture for specimens collected prospectively (4 of 204 specimens were positive) and compared to culture and/or EIA for archival specimens (42 of 85 specimens were positive). Both the EIA and PCR produced positive results from a specimen containing an O103 serotype STEC in the prospective specimens, and the PCR test detected three positive specimens that contained nonviable STEC in the archived specimens. The PCR assay demonstrated 100% sensitivity and specificity compared to EIA and/or culture and more rapid turnaround than either EIA or culture.
Comparison of Real-Time PCR for Detection of the tcdC Gene with Four Toxin Immunoassays and Culture in Diagnosis of Clostridium difficile Infection
Sloan, Lynne M., Duresko, Brian J., Gustafson, Daniel R., Rosenblatt, Jon E.

Journal of Clinical Microbiology | April 24, 2008 | Volume: 46 | Issue: 6 | Pages: 1996-2001

10.1128/jcm.00032-08 | PMID 18434563 Get It

ABSTRACT We have developed a rapid real-time PCR method using fluorescence resonance energy transfer probes and the LightCycler (Roche Diagnostics), which will detect the presence of the tcdC gene of Clostridium difficile in stool samples. Our PCR method also will identify the presence of base pair deletions, one of which (18 bp) has been associated with the “epidemic” toxin-hyperproducing strains. We compared the results of this PCR with those of three C. difficile toxin-detecting enzyme immunoassays (EIAs), an EIA for the detection of glutamate dehydrogenase (GDH), and culture of C. difficile . A total of 200 stool specimens were studied by the methods under comparison. C. difficile was isolated from 49 specimens by culture, and 44 of these were confirmed as containing one of the genes associated with toxin production (“toxigenic culture”). Using toxigenic culture as the “gold standard”, the sensitivities, specificities, and positive and negative predictive values, respectively, of the assays were 48%, 98%, 88%, and 87% for the Premier toxin A and B test; 48%, 99%, 91%, and 87% for the ImmunoCard toxin A & B test; 48%, 84%, 46%, and 85% for the Xpect C. difficile toxin A/B test; 32%, 100%, 100%, and 84% for the Triage C. difficile panel (for toxin A); and 86%, 97%, 90%, and 96% for the LightCycler PCR. Thus, in comparison to the sensitivity of toxigenic culture, the sensitivities of the toxin immunoassays were unacceptably low, while the LightCycler real-time PCR assay for the detection of the tcdC gene of C. difficile is sensitive and specific.
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, Mark J., Uhl, J. R., Sloan, Lynne M., Buckwalter, Seanne P., Jones, Mary F. , Vetter, Emily A., Yao, Joseph D. , Wengenack, Nancy L. , Rosenblatt, Jon E., Cockerill, F. R., Smith, T. F., Cockerill, Franklin R.

Clinical Microbiology Reviews | July 17, 2006 | Volume: 19 | Issue: 3 | Pages: 595-595

10.1128/cmr.00022-06 Get It

Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, Mark J., Uhl, J. R., Sloan, Lynne M., Buckwalter, Seanne P., Jones, Mary F. , Vetter, Emily A., Yao, Joseph D. , Wengenack, Nancy L. , Rosenblatt, Jon E., Cockerill, Franklin R., Smith, Thomas F.

Clinical Microbiology Reviews | January 17, 2006 | Volume: 19 | Issue: 1 | Pages: 165-256

10.1128/cmr.19.1.165-256.2006 | PMID 16418529 Get It

SUMMARY Real-time PCR has revolutionized the way clinical microbiology laboratories diagnose many human microbial infections. This testing method combines PCR chemistry with fluorescent probe detection of amplified product in the same reaction vessel. In general, both PCR and amplified product detection are completed in an hour or less, which is considerably faster than conventional PCR detection methods. Real-time PCR assays provide sensitivity and specificity equivalent to that of conventional PCR combined with Southern blot analysis, and since amplification and detection steps are performed in the same closed vessel, the risk of releasing amplified nucleic acids into the environment is negligible. The combination of excellent sensitivity and specificity, low contamination risk, and speed has made real-time PCR technology an appealing alternative to culture- or immunoassay-based testing methods for diagnosing many infectious diseases. This review focuses on the application of real-time PCR in the clinical microbiology laboratory.
Detection of Tropheryma whipplei DNA in Clinical Specimens by LightCycler Real-Time PCR
Sloan, Lynne M., Rosenblatt, Jon E., Cockerill, Franklin R.

Journal of Clinical Microbiology | July 6, 2005 | Volume: 43 | Issue: 7 | Pages: 3516-3518

10.1128/jcm.43.7.3516-3518.2005 | PMID 16000494 Get It

ABSTRACT A real-time PCR method using the LightCycler (Roche Applied Science, Indianapolis, IN) was compared to a conventional PCR assay for the detection of Tropheryma whipplei in 321 clinical specimens. The LightCycler method had sensitivity and specificity comparable to the conventional method but required considerably less labor and time (3 h versus 3 to 5 days).
Comparison of the Roche LightCycler vanA / vanB Detection Assay and Culture for Detection of Vancomycin-Resistant Enterococci from Perianal Swabs
Sloan, Lynne M., Uhl, J. R., Vetter, Emily A., Schleck, Cathy D. , Harmsen, William S. , Manahan, Janice M., Thompson, Roger, Rosenblatt, Jon E., Cockerill, Franklin R.

Journal of Clinical Microbiology | June 7, 2004 | Volume: 42 | Issue: 6 | Pages: 2636-2643

10.1128/jcm.42.6.2636-2643.2004 | PMID 15184445 Get It

ABSTRACT We compared the performance characteristics of a real-time PCR method, the LightCycler vanA / vanB detection assay (Roche Diagnostics Corporation, Indianapolis, Ind.) to that of Enterococcosel agar (BBL, Sparks, Md.) for direct detection of vancomycin-resistant enterococci (VRE) from 894 perianal stool swabs. For 421 of 894 swabs, the result for LightCycler PCR was compared to an Enterococcosel plate containing vancomycin at 6 μg/ml; for the remaining 473 swabs, the result for LightCycler PCR was compared to an Enterococcosel plate containing 8 μg/ml vancomycin. The LightCycler method produced considerably more positive results than either the Enterococcosel plate containing vancomycin at 6 μg/ml ( n = 25 versus n = 11; sensitivity, 100%; specificity, 97%; positive predictive value [PPV], 42%; negative predictive value [NPV], 100%) or the Enterococcosel plate containing vancomycin at 8 μg/ml ( n = 31 versus n = 10; sensitivity, 100%; specificity, 95%; PPV, 32%; NPV, 100%). When possible, additional testing, including culture, LightCycler PCR, and/or a conventional PCR method (PCR-restriction fragment length polymorphism assay), were performed on either the original specimens or original cultures or subsequent specimens for cases in which the original specimen was positive by LightCycler PCR but the Enterococcosel plate was negative. This additional testing demonstrated positive results for 7 of 14 (50%) evaluable discordant specimens which initially tested as LightCycler PCR positive but culture negative using the Enterococcosel plate containing vancomycin at 6 μg/ml and 12 of 17 (71%) evaluable discordant specimens which initially tested as LightCycler positive but culture negative using the Enterococcosel plate containing vancomycin at (8 μg/ml). These results demonstrate that the LightCycler VRE detection assay is considerably more sensitive than the standard culture method for detecting VRE directly from perianal swab specimens. The LightCycler assay also provides results much faster than culture (∼3.5 versus ≥72 h). The use of this test could have important implications for the effective control and prevention of nosocomial outbreaks of VRE.
Real-Time PCR Method for Detection of Encephalitozoon intestinalis from Stool Specimens
Wolk, Donna M. , Schneider, Susan K., Wengenack, Nancy L. , Sloan, Lynne M., Rosenblatt, Jon E.

Journal of Clinical Microbiology | October 30, 2002 | Volume: 40 | Issue: 11 | Pages: 3922-3928

10.1128/jcm.40.11.3922-3928.2002 | PMID 12409353 Get It

ABSTRACT The prevalence of microsporidiosis is likely underestimated due to the labor-intensive, insensitive, and nonspecific clinical laboratory methods used for the diagnosis of this disease. A real-time PCR assay was designed to assess DNA extraction methods and to detect three Encephalitozoon species in feces. Modifications of the MagNA Pure LC DNA isolation kit protocol (Roche Applied Sciences, Indianapolis, Ind.) were compared by using the automated MagNA Pure LC instrument (Roche) and fecal specimens spiked with Encephalitozoon intestinalis spores. Extracted DNA was amplified by the LightCycler (Roche) PCR assay. Assay sensitivity, reproducibility, and efficiency were assessed by comparing threshold crossover values achieved with different extraction and storage conditions (fresh, refrigerated, frozen, and preserved specimens). Optimal extraction conditions were achieved by using a commercial buffer, tissue lysis buffer (Roche), as the specimen diluent. LightCycler PCR results were compared to those obtained from routine stool microscopy with trichrome blue stain. The lower limit of detection for the LightCycler PCR assay varied by storage conditions from 10 2 to 10 4 spores/ml of feces, a value which represented a significant improvement over that achieved by staining (≥1.0 × 10 6 spores/ml). Melting temperature analysis of the amplicons allowed for the differentiation of three Encephalitozoon species ( E . intestinalis , E . cuniculi , and E . hellem ). The assay is readily adaptable to the clinical laboratory and represents the first real-time PCR assay designed to detect Encephalitozoon species.
Detection of Herpes Simplex Virus DNA in Genital and Dermal Specimens by LightCycler PCR after Extraction using the IsoQuick, MagNA Pure, and BioRobot 9604 Methods
Espy, Mark J., Rys, Paul N., Wold, Arlo D., Uhl, James R., Sloan, Lynne M., Jenkins, G. Douglas , Ilstrup, Duane M., Cockerill, F. R., Patel, Robin , Rosenblatt, Jon E., Smith, Thomas F., Cockerill, Franklin R., Patel, Robin

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 6 | Pages: 2233-2236

10.1128/jcm.39.6.2233-2236.2001 | PMID 11376062 Get It

ABSTRACT We evaluated two automated systems, MagNA Pure (Roche Molecular Biochemicals, Indianapolis, Ind.) and BioRobot 9604 (Qiagen, Inc., Chatsworth, Calif.) as effective replacements for the manual IsoQuick method (Orca Research, Inc., Bothell, Wash.) for extraction of herpes simplex virus (HSV) DNA from dermal and genital tract specimens prior to analysis by LightCycler PCR. Of 198 specimens (152 genital, 46 dermal), 92 (46.2%) were positive for HSV DNA by LightCycler PCR after automated extraction of specimens with either the MagNA Pure or BioRobot 9604 instrument. The manual IsoQuick method yielded HSV DNA (total n = 95) from three additional specimens that were negative by the automated method ( P = 0.25, sign test). Although the mean numbers of LightCycler PCR cycles required to reach positivity differed statistically significantly among all three of the methods of extraction, the estimated means differed by no more than 1.5 cycles ( P < 0.05). Seventy (76%) of the 92 specimens that were LightCycler PCR positive by all three extraction methods were also positive by shell vial cell culture assay. HSV DNA was detected by a lower LightCycler PCR cycle number (26.1 cycles) in specimens culture positive for the virus than in culture-negative samples (33.3 cycles) ( P < 0.0001). The manual IsoQuick and automated MagNA Pure and BioRobot 9604 methods provide standardized, reproducible extraction of HSV DNA for LightCycler PCR. The decision to implement a manual versus an automated procedure depends on factors such as costs related to the number of specimens processed rather than on the minimal differences in the technical efficiency of extraction of nucleic acids among these methods.