Citations

Mayo Clinic

Showing 10 of 108572 citations.

Abstract 17014: Differences in the Outcomes of Catheter Ablation for Ventricular Tachycardia in Patients With Ischemic versus Non-Ischemic Cardiomyopathy
Woelber, Tiffany, Dai, Qiying , Killu, Ammar M. , Siontis, Konstantinos C. , Deshmukh, Abhishek , Dhawan, Rahul , DeSimone, Christopher V. , Kowlgi, Gurukripa N.

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.17014 Get It

Background: Catheter ablation is an effective tool to reduce ventricular tachycardia (VT) burden. There is a lack of robust data studying the characteristics and outcomes of VT ablation in patients with ischemic (ICM) versus non-ischemic cardiomyopathy (NICM). Aims: The aim of this study was to assess the impact of ICM vs NICM on outcomes of VT ablation. Methods: A single-center, retrospective study of patients undergoing catheter ablation for VT was conducted. Results: A total of 168 patients, undergoing 200 VT ablation procedures, were included in this study. NICM group (112 procedures) was compared to ICM group (88 procedures). Patients in the ICM group were older (66.6 ± 13.4 vs 58.9 ± 14.4 years) and had higher rates of prior myocardial infarction (65.9% vs 3.6) and coronary artery bypass graft surgery (40.9% vs 1.8%). Overall, ICM group had more comorbidities like hypertension (80.7% vs 52.7%), diabetes mellitus (23.9% vs 12.5%), chronic kidney disease (45.5% vs 35.7%), stroke (17% vs 7.1%), and lower left ventricular ejection fraction (36.8 ± 13.2% vs 43.1 ± 14.7%). The ICM group had lower incidence of prior cardiac valvular surgery (9.1% vs 29.5%). The inducibility of VT (93% vs 93.5%; p= 1.0) and the number of different VT morphologies induced during the case (1.9 ± 1.5 vs 2.3 ± 2.5; p=0.19) was similar between the two groups. There was no acute mortality in either group. There was a non-significant trend towards greater VT recurrence in the NICM group (43.2% vs 33.3%, p= 0.19). However, patients with NICM had a lower VT-free survival as determined by Kaplan-Meier analysis (p=0.05) [Figure]. Long term mortality was higher in ICM group when compared to NICM group (18.2% vs 8.9%, p<0.01). Conclusion: Patients undergoing VT ablation in the NICM group when compared to the ICM group were noted to be younger, had fewer comorbidities, and lower long-term mortality. However, they had significantly less VT-free survival, likely owing to more challenging substrate responsible for VT.
Abstract 17002: Platelet-Derived Purified Exosome Product to Treat In-Stent Restenosis Porcine Model
Rizzo, Skylar A. , Singh, Swaiman, Witt, Tyra A. , Nagel, Mary, Stalboerger, Paul G., Nagel, Mary, Behfar, Atta

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.17002 Get It

Introduction: Patients with coronary artery disease (CAD) not amenable to revascularization are reported to have a 3-year mortality >14%. Advances in treatment modalities including medical management, rotational atherectomy, balloon lithotripsy, and drug-eluting stents work for focal disease but poorly treat diffuse CAD. In a porcine model of in-stent restenosis, we here evaluated whether a pro-angiogenic platelet-derived exosome product (PEP) could be delivered into the perivascular space to foster collateral vessel formation. Methods/Results: Cobalt chromium stents were placed and were oversized by 1 mm in the left anterior descending (LAD) and posterior descending arteries (PDA) of sus scrofa domesticus pigs. In-stent restenosis was angiographically visualized at the 2-month timepoint, with hemodynamic significance documented with fractional flow reserve (FFR) of <0.8. To document feasibility of PEP delivery into the perivascular space, exosomes were labeled with a far-red fluorescent tag and delivered into the perivascular bed. Here, the Bullfrog® micro-infusion catheter was positioned either in the great cardiac vein or the middle cardiac vein and PEP was delivered with the microneedle pointed towards the LAD or the PDA. Biodistribution demonstrated exosome retention and uptake around cardiac veins. Using the Bullfrog® technique, PEP was delivered in the perivascular space adjacent to areas of significant coronary stenosis. Initial results 1-month post-treatment demonstrated improved FFR of treated stenotic vessels (from 0.68 to 0.85), while untreated vessels demonstrate no change from previous FFR measurement (from 0.79 to 0.78). Conclusions: Here, exosome-mediated angiogenesis in the perivascular space improved coronary blood flow, distal to areas of stenosis. In patients with diffuse CAD, delivery of biotherapy in cardiac veins running anatomically parallel to stenosed epicardial arteries provides a novel therapeutic opportunity to supplement the existing armamentarium of therapies available for in-stent restenosis.
Abstract 16898: Myocardial Recovery Associated Gene Cdcp1 Expression Attenuates Cardiac Fibrosis in a Pressure Over-Load Mouse Model
Wang, Min , Vyas, Hridyanshu , Roos, Carolyn M, Huang, Runqing, Sahni, Jyotan , McNamara, Dennis M. , Barlera, Simona, Merlo, Marco , Chaloupka, Anna , Krejčí, Jan , Weinshilboum, Richard M. , Pereira, Naveen L. , Liu, Duan , Pileggi, Silvana , Mestroni, Luisa , Sinagra, Gianfranco , Pinet, F , Groote, Pascal de , Weinshilboum, Richard M. , Miller, Jordan D.

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.16898 Get It

Background: We have previously demonstrated by performing a genome-wide association study that a genetic locus resulting in ↓CDCP1 expression was associated with myocardial recovery in patients with dilated cardiomyopathy (DCM). We have subsequently shown that ↓CDCP1 decreases human cardiac fibroblast proliferation in vitro , however, its potential role in modulating cardiac fibrosis and function in vivo is unknown. Methods: A Cdcp1 knock-out (KO) mouse was generated on FVB/NJ background. Angiotensin II/Phenylephrine (AngII/PE) or saline was infused by an osmotic pump into mice ( Cdcp1 KO n=20; wild type/wt n=18) for 4 weeks. Echocardiography was performed at 0 and 4 weeks. Picrosirius red (PSR) staining was performed on cross-sectional heart tissue to identify cardiac fibrosis, which was quantified, using ImageJ software, as a percentage of left ventricular (LV) area stained by PSR. Results: LV mass index (LVMI) significantly increased in AngII/PE wt mice as compared to saline wt (figure a. 3.65±0.15 mg/g vs 3.05±0.17mg/g, p=0.01), however, AngII/PE Cdcp1 KO mice had significantly decreased LVMI as compared to AngII/PE wt mice (figure a. 3.17±0.09 mg/g vs 3.65±0.15 mg/g, p=0.01). In addition, fractional shortening trended higher in AngII/PE Cdcp1 KO mice as compared to AngII/PE wt mice (figure b. 50.36±2.06% vs 45.48±1.43%, p=0.07). Extent of cardiac fibrosis was significantly higher in AngII/PE wt mice as compared to saline wt (figure c. 15.79±0.49% vs 7.93±0.39%, p<0.0001), however AngII/PE Cdcp1 KO mice had significantly reduced cardiac fibrosis as compared to AngII/PE wt mice (figure c. 9.41±0.43%, p<0.0001). Conclusions: CDCP1 KO significantly reduces pressure over-load induced LV hypertrophy and cardiac fibrosis. Its role as a novel therapeutic target in attenuating fibrosis and improving cardiac function in DCM needs to be further explored.
Abstract 16885: Progression of Aortic Valve Stenosis in Atrial Fibrillation versus Sinus Rhythm: Implications for Clinical Practice and Severe Aortic Stenosis Diagnosis
Fabre, Katarina L. , Lewis, Bradley R., Miranda, William R. , Oh, Jae K. , Nkomo, Vuyisile T. , Ito, Saki , Pislaru, Sorin V.

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.16885 Get It

Introduction: Rate of aortic stenosis (AS) progression in patients with concurrent atrial fibrillation (AF) has not been previously described. Objectives: To describe changes over time in aortic valve area (AVA) and associated hemodynamics during AS progression in patients in AF versus sinus rhythm (SR). Methods: Patients with AVA ≤ 1 cm 2 and preserved left ventricular ejection fraction ≥50% were identified from the Mayo Clinic Echocardiographic Laboratory Database. Serial echocardiograms prior to the development of AVA ≤ 1 cm 2 (Time 0) were examined. Inverse probability weighting was used for statistical analysis. Results: A total of 166 patients were included (SR=79 and AF=87), mean age 78.1 ± 7.8 years, females 31%. The rates of AVA reduction (-0.14±0.01 vs -0.12±0.01 cm2/year, p=0.31) and increase in trans-aortic peak velocity (+0.23 ± 0.02 vs +0.22 ± 0.02 m/sec, p=0.55) and mean gradient (MG) (3.9 ± 0.3 vs 3.8 ± 0.4 mmHg, p=0.83) did not differ between AF and SR (Figure 1). However, AF was associated with systematically lower forward stroke volume index (SVi), peak velocity and MG for the same AVA compared to SR (p<0.04 for all) throughout AS progression. When AVA reached 1 cm 2 , SVi (38.8±6.6 vs 45.7 ±8.9, p=0.02), peak velocity (3.9 ± 0.6 vs 4.1 ± 0.6 m/sec, p=0.04) and MG (36.6±10.9 vs 41±12.8 mmHg, p=0.03) were lower in AF compared to SR. Conclusions: The rate of AS progression was not different in AF versus SR. However, forward flow was systematically lower in AF resulting in discordant AS during AS progression and when AVA reached 1 cm 2 . Doppler velocity and MG criteria for severe AS appear to be lower in AF versus SR which has implications for timely diagnosis of severe AS and patient management.
Abstract 16836: A View-Invariant Deep Learning Model for Estimating Ejection Fraction From Any Valid Echocardiogram Videoclip, Including Point-of-Care Ultrasound (POCUS)
Jackson, John I. , Rostami, Behrouz , Bird, Jared, Friedman, Paul A. , Kane, Garvan C. , Anisuzzaman, DM , Malins, Jeffrey G. , Lee, Eunjung , Naser, Jwan A. , López-Jiménez, Francisco , Pislaru, Sorin V. , Attia, Zachi I.

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.16836 Get It

Background: Recently, our team developed an end-to-end artificial intelligence (AI) framework that can successfully estimate left ventricular ejection fraction (LVEF) from echocardiogram videos. However, this framework requires specific views (A2C and PLAX), and cannot estimate LVEF for studies from which these views are missing. Goal: To develop a deep learning model to estimate LVEF from any type and number of echocardiogram video(s). Methods: We built a deep learning model for B-mode echocardiogram videos of the left ventricle (A2C, A3C, A4C, or PLAX views), using retrospective transthoracic echocardiography (TTE) data. The model was evaluated with two test datasets: one with random valid (i.e., showing the left ventricle) views, and one with preselected views (both having 433 patients). Later, the model was tested with a prospective patient cohort that had both TTE and point-of-care ultrasound (POCUS) data collected simultaneously (393 patients). Results: On the retrospective TTE test set, we observed excellent performance (five random valid views per study: RMSE of 6.87% and Pearson correlation (PC) of 0.82 on LVEF estimation, and an AUC of 0.96 (95% CI: of 0.94-0.98) on low LVEF classification (<=40%); preselected views: RMSE of 6.75%, PC of 0.83, and an AUC of 0.96 (95% CI: 0.94-0.98)). For both TTE and POCUS data from the prospective cohort, we also observed strong performance (TTE: RMSE of 5.62%, PC of 0.87, and an AUC of 0.97; POCUS: RMSE of 6.12%, PC of 0.84, and an AUC of 0.96). For the prospective test sets as well as for the retrospective TTE test set with preselected views, results reflect the estimated LVEF average of A2C, A3C, A4C, and PLAX videos from each patient. Conclusions: For both TTE and POCUS data, the current model showed strong performance which was comparable to that of our previously established view-specific model. Alongside this comparable performance, the current model surpasses our previous model in terms of flexibility, as it isn't dependent on view classification and allows a broader selection in terms of the number and types of videos per study or patient. This innovative approach could prove particularly beneficial in point-of-care situations in which it may not be feasible to obtain high-quality, view-specific videos.
Abstract 16830: Feasibility and Safety of Intracardiac Echocardiography Guidance in Mitral Transcatheter Edge-to-Edge Repair: Analysis of the National Inpatient Sample Data From 2015 to 2020
Khalouf, Amani, Aggarwal, Ankit, Mohamed, Mohamed Salah , Kashou, Anthony H. , Chaaya, Rody Bou, Little, Stephen H. , Naidu, Srihari S. , Hashem, Anas , Aggarwal, Ankit, Chaaya, Rody G. Bou , Rai, Devesh , Goel, Sachin S.

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.16830 Get It

Introduction: Data on use of ICE guidance in TEER procedure is limited to case reports and small case series. Our study aims to assess the feasibility, safety, utilization patterns and clinical outcomes of mitral TEER procedure with ICE guidance using a nationally representative real-world cohort of patients.Hypothesis: There is no difference between ICE-guided TEER and TEE-guided TEER in the clinical outcomes and complications. Methods: This study used the National Inpatient Sample database from quarter 4 of 2015 to 2020. We used a propensity-matched analysis and adjusted odds ratios for in-hospital outcomes/complications. A P value of <0.05 was considered significant. Results: A total of 38,770 weighted cases of mitral TEER were identified. Of the included patients 665 patients underwent ICE-guided TEER while 38,105 had TEE-guided TEER. There were no differences in the in-hospital mortality between both groups (2.5% vs. 3.0%, p=0.58). Adjusted odds of in-hospital mortality (aOR 0.83, 95%CI [0.42-1.64]) were not significantly different. There were no differences in periprocedural complications including cardiac (aOR 0.85, 95%CI [0.54-1.35]), bleeding (aOR 1.45, 95%CI [0.93-2.33]), respiratory (aOR 0.88, 95%CI [0.61-1.25]), and renal (aOR 0.89, 95%CI [0.66-1.20]) complications between patients undergoing ICE-guided versus TEE-guided TEER. There was no difference in GI complications between both groups (aOR 1.11, 95%CI [0.46-2.70]). The adjusted length of stay was less among ICE-guided TEER (median: 1 vs. 2, p<0.01) with no differences in costs of hospitalization ($137,312 vs. $153,773, p=0.06), Conclusions: In conclusion, ICE-guided mitral TEER is safe when compared with TEE guided TEER with no significant differences in in-hospital mortality, cardiac, bleeding, respiratory, and renal complications. The length of stay in ICE group is shorter as compared with the TEE group.
Abstract 16659: Neo LVOT Prediction With the Innovalve TMVR System - CT Preliminary Results
Goitein, Orly , Meerkin, David , Guetta, Victor , Avner, Avi , Rihal, Charanjit S. , Raanani, Ehud , Rihal, Charanjit S.

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.16659 Get It

Introduction: The Innovalve TMVR is a novel self-expandable trans-catheter mitral valve prosthesis, delivered trans-septally using femoral venous access. It is deployed in an intra-valvular posterior position after sub-valvular anchoring by rotation of 6 circumferential arms. LV outflow tract (LVOT) compromise is of great concern in TMVR. A predicted Neo LVOT area of 170 mm 2 is the currently accepted cut-off for LVOT obstruction. Hypothesis: CT can accurately predict the Neo LVOT area prior to Innovalve TMVR procedure. Methods: CT was performed as a screening tool to evaluate the Neo LVOT area prior to Innovalve TMVR procedure. CT protocol: Retrospectively ECG gated with full cardiac cycle coverage. CT was performed before and after the procedure. Predicted Neo LVOT (pNLVOT) was calculated using a dedicated simulation valve prior to TMVR, actual Neo LVOT (aNLVOT) was calculated with the inserted valve in place following TMVR. The native LVOT (nLVOT) area, the predicted % LVOT reduction (nLVOT area-pNLVOT area /nLVOT area), the actual % LVOT reduction (nLVOT area-aNLVOT area /nLVOT area) and the difference between them (pNLVOT%-aNLVOT%) were calculated. Results: One hundred patients were screened for Innovalve TMVR procedure based on Neo LVOT criteria. pNLVOT≥ 170 mm 2 was found in 11 patients (11%), (7 males) average age 68±10 years, these patients underwent Innovalve TMVR procedure. The median calculated LVOT was 647.8+/-260 mm 2 (range 373-1312), the median pNLVOT reduction was 16% ±15 (range 3-53), the median aNLVOT reduction was 5%±14 (range -5-40) and the median difference between the pNLVOT and aNLVOT was 8±12 (range -4-31). In 8/11 patients (73%), the aNLVOT was larger than the pNLVOT (range difference 1 to 31%). In 3/11 patients (27%), the aNLVOT was smaller than the pNLVOT (range difference -1 to -4%). Conclusions: Underestimation of neoLVOT reduction, was uncommon and documented only minor and clinically insignificant difference between the pNLVOT and aNLVOT. As overestimation of NLVOT reduction allows a margin of safety for MTVR, we conclude that CT can serve as reliable NLVOT screening tool.
Abstract 16590: Left Ventricular Remodelling Following Transcatheter Mitral Valve Replacement With the Innovalve System
Goitein, Orly , Meerkin, David , Guetta, Victor , Schwammenthal, Ehud, Butnaru, A, Avner, Avi , Rihal, Charanjit S. , Raanani, Ehud , Rihal, Charanjit S.

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.16590 Get It

Introduction: Transcatheter Mitral Valve Replacement (TMVR) using a trans-septal approach is a new therapeutic option for patients with severe mitral regurgitation (MR). However, both surgical as well as currently under-testing trans-catheter approach, are shown to cause decrease in LV function. The Innovalve TMVR is a novel self-expandable transcatheter mitral valve prosthesis, delivered trans-septally using femoral venous access. It is deployed in an intravalvular posterior position after subvalvular anchoring by rotation of 6 circumferential arms Hypothesis: TMVR procedure (Innovalve system) leads to LV anatomical and functional changes Methods: CT was performed before the Innovalve TMVR procedure, and after 3 to 6 months. CT protocol included retrospective ECG gating with full cardiac cycle coverage. LV end diastolic and end systolic diameters (LVEDD, LVESD) were measured in the left ventricular outflow tract orientation at the most basal level. Tip to tip papillary muscle distance was measured in the short axis orientation at the most basal slice demonstrating the papillary muscle tips. LV ejection fraction (LVEF) was calculated using the end systolic and end diastolic volumes. All measurements were performed at end systole and end diastole before MTVR and after 3-6 months using a dedicated platform (3Mensio). Results: Ten patients (7 males) average age 69+/-10 years, underwent the Innovalve TMVR procedure. Average LVESD decreased from 52±15 mm at baseline to 44±15mm (P=0.016) at 3-6 months. Similarly, LVEDD decreased from 60±14 mm at baseline, to 52±13mm at 3-6 months (P=0.039). Average papillary muscle tip to tip distance at end diastole (ED) decreased from 31.7±7mm at baseline to 28.4±6.5mm at 3-6 months (P=0.047).A trend of LVEF improvement was evident with an increase from 35%±12 average at baseline compared with 39%±12 average after 3-6 months (P=0.346). Conclusions: These preliminary results show that the TMVR procedure using the Innovalve system may result in favourable LV reverse remodelling changes including reduction of LVESD, LVEDD and ED papillary muscle distances, with improved LVEF. This encouraging data might suggest favourable postprocedural structural LV change.
Abstract 16570: Benchmarking Risk-Adjusted Outcomes in Congenital Heart Surgery
Subramanyan, Ram Kumar, Thibault, Dylan, O’Brien, Sean M. , Shahian, David M. , Bacha, Emile , Badhwar, Vinay , Caldarone, C.A., Fernández, Félix G. , Pasquali, Sara K. , Rainey, Tabitha, Romano, Jennifer C., Shashidharan, Subhadra, Tweddell, James S., Mayer, John E. , Gaynor, J. William , Dearani, Joseph A. , Jacobs, Jeffrey P. , Overman, David M.

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.16570 Get It

Background: Robust models exist to predict risk-adjusted mortality following congenital heart surgery. It is known that underlying diagnosis modifies predicted risk of operations, and institution-level outcomes vary based on their unique case mix. We therefore evaluated risk-adjusted outcomes for a subset of diagnosis-procedure (D-P) combinations within the Society of Thoracic Surgeons' (STS) congenital heart surgery database (CHSD). Methods: A clinician panel identified the most frequently encountered D-P combinations in CHSD between 07/2017 and 06/2021. Candidate modeling techniques were compared in a random 80% development cohort. Model performance was assessed using internal and cross-validation calibration, discrimination plots and optimism adjusted C-statistics. The final selected model was evaluated in the 20% validation sample. Results: The chosen subset of D-P combinations represented 45,384 of 87,589 (52%) unique episodes of surgical care in CHSD during this time-period. The development cohort (36,350 episodes) had 1.8% mortality (667 deaths). All candidate models had excellent discrimination with C-statistics ranging from 0.862 to 0.876. The model with the best combination of discrimination, calibration, and clinical face validity was a modified version of the current STS mortality risk model. This version included all current risk model variables with the addition of indicator variables for D-P combinations. In the 20% validation sample (9,034 episodes), this model was well calibrated (Figure) and had excellent discrimination (C = 0.879). Conclusion: We describe a cohort of D-P combinations widely encountered in the STS CHSD. Further, we refined the existing STS CHSD risk model for application to these D-P dyads to derive empirical risk-adjusted benchmark outcomes. This approach will benefit quality improvement efforts at an institutional level and may have implications for publicly reporting congenital heart surgery outcomes.
Abstract 16517: Association of Low Left Atrial Appendage Velocity With Increased Risk of Atrial Fibrillation Recurrence After Catheter Ablation: A Meta-Analysis
Katukuri, Nishanth , Venugopalan, Sruthi , Majmundar, Vidit , Siddiq, Sajid, Raval, Maharshi , Jain, Akhil , Desai, Rupak

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.16517 Get It

Background: Catheter ablation (CA) is an effective and potentially curative treatment in patients with atrial fibrillation (AF). However, the recurrence of AF following CA treatment in cases of persistent atrial fibrillation (PeAF) remains a significant concern. This study aims to establish a correlation between the peak flow velocity of the left atrial appendage (LAAV) and the AF recurrence post-CA for PeAF. Methods: PubMed/Medline, EMBASE, and SCOPUS databases were systematically reviewed to find studies through June 2023 reporting data on the relationship between the LAAV and the recurrence of AF in individuals who have undergone CA for PeAF. Binary random effects models were used to estimate pooled outcomes. I2 statistics were used to interpret heterogeneity, with I 2 >75% indicating substantial inter-study variation. Leave-one-out meta-analysis was performed to evaluate the effect of each study on the overall estimate. A p<0.05 was considered statistically significant. Results: A total of 9 studies between 2000-2023 were included in our meta-analysis. The pooled univariate analysis revealed no association between LAAV and recurrence of AF in individuals who have undergone CA with a pooled OR of 1.09 (95CI 0.96-1.22) p=0.45, I2=86.59%. The multivariate analysis, after adjusting for overall modifiable risk factors, yielded significant results, with an adjusted odds ratio (aOR) of 1.41 (95CI 1.15-1.74) p<0.01, I2=85.24%. Sensitivity analysis, using the leave-one-out method&nbsp;demonstrated the robustness and stability of the results, indicating that no single study disproportionately influenced the overall&nbsp;findings with aOR 1.41 (95CI 1.15-1.74) p<0.01. Conclusions: This meta-analysis revealed that low LAAV is associated with high-risk of AF recurrence following CA. Identifying a specific subgroup of individuals at high risk of AF recurrence with the help of pre-CA LAA velocity will facilitate the early institution of alternative treatment strategies.