Abstract Aims Pulsed field ablation for atrial fibrillation offers shorter procedural times and improved safety compared with thermal ablation, but the optimal anaesthesia strategy remains uncertain. Most centres in the USA use general anaesthesia with endotracheal intubation, whereas monitored anaesthesia care without endotracheal intubation may be a safe and efficient alternative. Objectives To compare procedural efficiency and safety between monitored anaesthesia care and general anaesthesia for pulsed field ablation. Methods and results Consecutive adults who underwent pulsed field ablation for atrial fibrillation between 2024 and 2025 at Marshfield Clinic Health System were included. The anaesthesia approach was determined by operator preference. Procedural times, medication use, complications, and patient tolerance were recorded prospectively. Among 200 patients, 100 received monitored anaesthesia care without endotracheal intubation, and 100 received general anaesthesia. The mean age was 67 years, 42% were female, and the mean body mass index was 33 kilograms per square metre. Monitored anaesthesia care shortened case duration (77 vs. 95 min; P < 0.001) and laboratory time (118 vs. 153 min; P = 0.002) and required fewer adjunct medications (P < 0.001). Twenty-five procedures (25%) were challenging due to cough or motion but were all completed safely. Complications occurred in one monitored anaesthesia care case and six general anaesthesia cases (P = 0.054). Pulmonary vein isolation was achieved in all patients. Conclusion Monitored anaesthesia care without endotracheal intubation was safe, efficient, and resource-sparing compared with general anaesthesia for pulsed field atrial fibrillation ablation.
Outcomes of Minimally Interrupted versus Uninterrupted Direct Oral Anticoagulants Use Prior to Implantation of Cardiac Implantable Electronic Devices
ABSTRACT Background Optimal management of direct oral anticoagulants (DOAC) prior to implantation of cardiac implantable electronic devices (CIED) remains controversial. Objective To determine whether a strategy of minimal interruption of DOAC before cardiac CIED implantation is associated with improved clinical outcomes compared to uninterrupted DOAC use. Methods The electronic clinical records of 310 patients who were on DOAC and underwent CIED implantation were evaluated. The patients were separated into 2 groups: patients in Group 1 had minimal DOAC interruption (DOAC held < 24 h before procedure), while patients in Group 2 continued DOAC before procedure. Resumption of DOAC in both groups was on the same day of the procedure or the next morning at the operator's discretion. Clinically significant pocket hematoma and thromboembolic events were compared. Results Among the 310 patients, 71 (22.9%) of them had DOAC held < 24 h before procedure, while DOAC was continued without interruption in 239 (77.1%) in the periprocedural period. Clinically significant pocket hematomas were found in 1 patient (1.4%) in the DOAC interrupted group and 24 (10.0%) in the DOAC continuous group ( p = 0.046). Low thromboembolic events were observed in both groups: 0 in the minimally interrupted group and 1 (0.4%) in the un‐interrupted group ( p > 0.05). Conclusion The bleeding risk in our cohort of patients who underwent CIED implantation with the uninterrupted DOAC approach is higher than previously reported in the literature. A minimally interrupted approach appears to mitigate this risk without significantly increasing the risk of thromboembolism.
Atrial and Ventricular Dyssynchrony, Cardiomyopathy, and Atrial Fibrillation: To Synchronize or to Ablate First?
ABSTRACT Background Optimal management in patients presenting with persistent atrial fibrillation, cardiomyopathy, and atrial as well as ventricular dyssynchrony with left bundle branch block is unclear. Results and Methods A 67‐year‐old female patient presented with persistent atrial fibrillation, cardiomyopathy with a newly reduced ejection fraction (EF), increased P wave duration on electrocardiogram (ECG) and left bundle branch block. After shared decision making, the patient elected to proceed with Bachman bundle/left bundle branch area pacing plus atrioventricular (AV) node ablation. At 6‐month follow‐up post procedure, a repeat echocardiogram showed normalized atrial size and EF (65%). Device interrogation demonstrated no recurrent atrial fibrillation with the patient off antiarrhythmic and heart failure medical therapy. Conclusions Integrated atrial and ventricular synchronization through Bachmann bundle and left bundle branch area pacing may help break the cycle of dyssynchrony, remodeling, and arrhythmia. In combination with AV node ablation, it may be considered as an alternative treatment option in certain cases after shared decision making.
Safety and efficacy of ultra-long intermediate-power ablation for outflow tract ventricular arrhythmia arising from the left ventricular summit
Abstract Background Radiofrequency ablation (RFA) has been effective in managing premature ventricular contractions (PVCs). Despite improvement in ablation techniques, recurrence remains high for LV summit PVCs. Epicardial ablation here is often precluded due to fat and proximity to coronaries, thus, aggressive but safe endocardial options are needed. Purpose To evaluate the safety and effectiveness of ultra-long ablation (>240 seconds) duration for refractory LV summit PVCs. Methods Patients with deep intramural LV summit PVCs were identified by lack of PVC elimination or late (>60 s suppression) and recurrence post-lesion under the left aortic sinus of Valsalva. We included patients who received the longest RFA of at least 240 seconds (maximum 15 minutes). RFA power was titrated slowly from 20 to 35W, carefully ensuring that the impedance drop did not exceed 12 ohms. Acute procedure success was defined as clinical PVC suppression for ≥60 minutes after the last lesion. Short-term success was defined as symptom improvement, ejection fraction (EF) recovery, and drop in PVC burden at 3 months. Results Twenty patients (59.5 ± 16.4 years, 55% male) were included. Baseline features are shown in Table 1. All RFA were delivered endocardially. No steam pops were noted. PVC burden was significantly lower at 3-month follow-up (P< 0.01), Figure 1A. Most patients had a normal ejection fraction (EF) at baseline; thus, no significant difference change in EF was observed (Figure 1B). One complication was recorded, which was tamponade likely caused by coronary sinus dissection requiring pericardiocentesis. Acute success was achieved in 95.0% of the cases, and all cases followed at 3 months (18/18) achieved short-term success. Conclusion Ultra-long duration RFA with lesions ≥ 240 seconds at 35W per lesion for LV summit PVCs appeared to be safe and effective in achieving acute and short-term success. The lack of acute suppression should not discourage operators, as there seems to be delayed suppression in some cases. Careful monitoring of biophysics is paramount when attempting this technique.
Abstract 17014: Differences in the Outcomes of Catheter Ablation for Ventricular Tachycardia in Patients With Ischemic versus Non-Ischemic Cardiomyopathy
Background: Catheter ablation is an effective tool to reduce ventricular tachycardia (VT) burden. There is a lack of robust data studying the characteristics and outcomes of VT ablation in patients with ischemic (ICM) versus non-ischemic cardiomyopathy (NICM). Aims: The aim of this study was to assess the impact of ICM vs NICM on outcomes of VT ablation. Methods: A single-center, retrospective study of patients undergoing catheter ablation for VT was conducted. Results: A total of 168 patients, undergoing 200 VT ablation procedures, were included in this study. NICM group (112 procedures) was compared to ICM group (88 procedures). Patients in the ICM group were older (66.6 ± 13.4 vs 58.9 ± 14.4 years) and had higher rates of prior myocardial infarction (65.9% vs 3.6) and coronary artery bypass graft surgery (40.9% vs 1.8%). Overall, ICM group had more comorbidities like hypertension (80.7% vs 52.7%), diabetes mellitus (23.9% vs 12.5%), chronic kidney disease (45.5% vs 35.7%), stroke (17% vs 7.1%), and lower left ventricular ejection fraction (36.8 ± 13.2% vs 43.1 ± 14.7%). The ICM group had lower incidence of prior cardiac valvular surgery (9.1% vs 29.5%). The inducibility of VT (93% vs 93.5%; p= 1.0) and the number of different VT morphologies induced during the case (1.9 ± 1.5 vs 2.3 ± 2.5; p=0.19) was similar between the two groups. There was no acute mortality in either group. There was a non-significant trend towards greater VT recurrence in the NICM group (43.2% vs 33.3%, p= 0.19). However, patients with NICM had a lower VT-free survival as determined by Kaplan-Meier analysis (p=0.05) [Figure]. Long term mortality was higher in ICM group when compared to NICM group (18.2% vs 8.9%, p<0.01). Conclusion: Patients undergoing VT ablation in the NICM group when compared to the ICM group were noted to be younger, had fewer comorbidities, and lower long-term mortality. However, they had significantly less VT-free survival, likely owing to more challenging substrate responsible for VT.
Abstract 15352: Deep Learning Model-Enabled Electrocardiogram to Localize Premature Ventricular Contractions in Patients Referred for Catheter Ablation
Introduction: Accurate pre-procedure localization of the premature ventricular contractions (PVCs) is critical in preparing for the ablation. So far, no tools exist for artificial intelligence guided PVC-localization. Hypothesis: Trained deep learning model will be able to predict the site of origin (SOO) of PVCs using 12 lead electrocardiogram (ECG). Methods: We analyzed 707 ECG-ablation pairs from 2403 patients who had at least one ECG flagged for PVCs in the 6 months prior to their procedure. First, we used a cohort of 100,000 ECGs without PVCs and 10,000 ECGs with PVCs to train a convolutional neural network (CNN) to isolate the ECG segments with PVCs in them from a 12-lead ECG (Figure 1). We then trained two models, one utilizing a 10-second 12-lead ECG, and the other with just the isolated PVC beats as input. The models were trained using the Keras framework with TensorFlow (Google). Results: The mean age of the patients in the cohort was 61.2 ± 15.0 years. 66.3 percent of patients underwent left ventricle ablation, 54.6 percent had outflow ablation, and 55.3 percent had ablation of sites with leftward axis (septal location for midline and left ventricle PVCs). The model trained on 10-second ECGs yielded validation and test AUCs of 0.941 and 0.931 for outflow, 0.898 and 0.891 for ventricle, and 0.863 and 0.846 for leftward axis (Figure 1A). The model trained on isolated segments containing PVC beats yielded validation and test AUCs of 0.966 and 0.957 for outflow, 0.879 and 0.907 for ventricle, and 0.846 and 0.829 for SOO for leftward axis (Figure 1B). Conclusions: We have trained an accurate convolutional neural network that can predict SOO using the surface ECG. Further fine-tuning would be needed to refine the model and develop prediction of specific sites.
Detection of left ventricular contractile dysfunction in patients with premature ventricular contractions using electrocardiogram trained using a deep learning model
Abstract Background Premature ventricular contractions (PVCs) are the most common arrhythmia affecting the ventricle. Frequent PVCs are associated with the development of PVC-cardiomyopathy (CM). It is known that the PVC burden has a direct correlation to the severity of left ventricular (LV) dysfunction. However, only 5% of patients with frequent PVCs (>10,000 per day) have associated PVC-CM. Thus, selecting patients for therapy options with drugs or catheter ablation is challenging, especially, when patients are asymptomatic with the PVCs. Purpose To train a deep learning model to predict the probability of low LV ejection fraction (LVEF) in patients with PVCs on a 12-lead electrocardiogram (ECG). Methods Using 69,440 paired 12-lead ECGs (containing at least one PVC), and echocardiogram data, including the left ventricular ejection fraction at Mayo Clinic, we trained a convolutional neural network to identify patients with ventricular dysfunction, defined as ejection fraction ≤35%, using the ECG data alone. ECGs were acquired at a sampling rate of 500 Hz using a Marquette ECG machine (GE Healthcare) and stored using the MUSE data management system for later retrieval. Comprehensive 2-D or 3-D and Doppler echocardiography were available for all patients. We trained a convolutional neural network using the Keras framework with TensorFlow (Google). The ECG-echocardiogram pairs were divided into a 60:20:20 training:validation:test split. Results The mean age of the patients used to train the model was 69.9 ± 13.0 years, and 65.2 percent of patients were male. The mean LVEF for this population was 52 ± 14.9 %, and the proportion of patients with low LVEF was 16.8 percent. The model yielded values for area under the curve, sensitivity, specificity, and accuracy of 0.897, 0.830, 0.813, and 0.816, respectively (Figure 1). A representative example of model prediction of normal LVEF and low LVEF is shown in Figure 2. Conclusion Using large-scale data, we have trained a highly accurate convolutional neural network with excellent predictive accuracy for LV systolic dysfunction using the surface ECG. Such a tool would be invaluable for cardiologists when risk-stratifying patients with frequent PVCs, especially those that are asymptomatic. Patients at risk will benefit from early referral to electrophysiologists for drug therapy and catheter ablation to mitigate the risk of PVC-CM.Figure 1Figure 2
Left bundle branch area pacing for heart failure patients requiring cardiac resynchronization therapy: A meta‐analysis
AbstractIntroductionLeft bundle branch area pacing (LBBP) is a novel conduction system pacing method to achieve effective physiological pacing and an alternative to cardiac resynchronization therapy (CRT) with biventricular pacing (BVP) for patients with heart failure with reduced ejection fraction (HFrEF). We conduted this meta‐analysis and systemic review to review current data comparing BVP and LBBP in patients with HFrEF and indications for CRT.MethodsWe searched PubMed/Medline, Web of Science, and Cochrane Library from the inception of the database to November 2022. All studies that compared LBBP with BVP in patients with HFrEF and indications for CRT were included. Two reviewers performed study selection, data abstraction, and risk of bias assessment. We calculated risk ratios (RRs) with the Mantel–Haenszel method and mean difference (MD) with inverse variance using random effect models. We assessed heterogeneity using the I2 index, with I2 > 50% indicating significant heterogeneity.ResultsTen studies (9 observational studies and 1 randomized controlled trial; 616 patients; 15 centers) published between 2020 and 2022 were included. We observed a shorter fluoroscopy time (MD: 9.68, 95% confidence interval [CI]: 4.49–14.87, I2 = 95%, p < .01, minutes) as well as a shorter procedural time (MD 33.68, 95% CI: 17.80–49.55, I2 = 73%, p < .01, minutes) during the implantation of LBBP CRT compared to conventional BVP CRT. LBBP was shown to have a greater reduction in QRS duration (MD 25.13, 95% CI: 20.06–30.20, I2 = 51%, p < .01, milliseconds), a greater left ventricular ejection fraction improvement (MD: 5.80, 95% CI: 4.81–6.78, I2 = 0%, p < .01, percentage), and a greater left ventricular end‐diastolic diameter reduction (MD: 2.11, 95% CI: 0.12–4.10, I2 = 18%, p = .04, millimeter). There was a greater improvement in New York Heart Association function class with LBBP (MD: 0.37, 95% CI: 0.05–0.68, I2 = 61%, p = .02). LBBP was also associated with a lower risk of a composite of heart failure hospitalizations (HFH) and all‐cause mortality (RR: 0.48, 95% CI: 0.25–0.90, I2 = 0%, p = .02) driven by reduced HFH (RR: 0.39, 95% CI: 0.19–0.82, I2 = 0%, p = .01). However, all‐cause mortality rates were low in both groups (1.52% vs. 1.13%) and similar (RR: 0.98, 95% CI: 0.21–4.68, I2 = 0%, p = .87).ConclusionThis meta‐analysis of primarily nonrandomized studies suggests that LBBP is associated with a greater improvement in left ventricular systolic function and a lower rate of HFH compared to BVP. There was uniformity of these findings in all of the included studies. However, it would be premature to conclude based solely on the current meta‐analysis alone, given the limitations stated. Dedicated, well‐designed, randomized controlled trials and observational studies are needed to elucidate better the comparative long‐term efficacy and safety of LBBP CRT versus BIV CRT.
Left bundle branch area pacing for heart failure patients requiring cardiac resynchronization therapy: a meta-analysis
Background: Left bundle area branch pacing (LBBP) is a novel conduction system pacing method to achieve effective physiological pacing and an alternative to cardiac resynchronization therapy (CRT) with biventricular pacing (BVP) for patients with heart failure and reduced ejection fraction (HFrEF). Objective: To review current data comparing BVP and LBBP in patients with HFrEF and indication CRT. Methods: We searched PubMed/Medline, Web of Science, and Cochrane Library from the inception of the database to November 2022. All studies that compared LBBP with BVP in patients with HFrEF and indications of CRT were included. Two reviewers performed the study selection, data abstraction, and risk of bias assessment. We calculated risk ratios with the Mantel-Haenszel method and mean difference with inverse variance using random effect models. We assessed heterogeneity using the I 2 index, with I 2 > 50% indicating significant heterogeneity. Results: Ten studies (9 observational studies and 1 randomized controlled trial; 616 patients; 15 centers) published between 2020 and 2022 were included. We observed a shorter fluoroscopy time [mean difference (MD) 9.68, 95% CI 4.49-14.87, I 2 =95%, P<0.01, minutes] as well as a shorter procedure time (MD 33.68, 95% CI 17.80-49.55, I 2 =73%, P<0.01, minutes) during implantation of LBBP CRT compared to conventional BVP CRT. LBBP was shown to have a greater reduction in QRSd (MD 25.13, 95%CI 20.06-30.20, I 2 = 51%, P<0.01, milliseconds) a greater left ventricular ejection fraction (LVEF) improvement (MD 5.80, 95% CI 4.81-6.78, I 2 =0%, P<0.01, percentage) and a greater ventricular end-diastolic diameter (LVEDD) reduction (MD 2.11, 95% CI 0.12-4.10, I 2 =18%, P=0.04, millimeter). There was a greater improvement in New York Heart Association function (NYHA) class with LBBP (MD 0.37, 95% CI 0.05-0.68, I 2 =61%, P=0.02).LBBP was also associated with a lower risk of a composite of heart failure hospitalizations and all-cause mortality [Risk ratio (RR) 0.48, 95% CI 0.25-0.90, I 2 =0%, p=0.02] driven by reduced heart failure hospitalizations (RR 0.39, 95% CI 0.19-0.82, I 2 =0%, p=0.01). However, all-cause mortality rates were low in both groups (1.52% vs. 1.13%) and similar (RR 0.98, 95%CI 0.21-4.68, I 2 =0%, p=0.87). Conclusion: Compared to BVP, LBBP is associated with, a greater improvement in LV systolic function, and a lower rate of heart failure-related hospitalization. Dedicated randomized controlled trials and larger patient populations are needed to further elucidate the long-term safety and efficacy of LBBP CRT.