Back to Authors

ezzedine, fatima m

Mayo Clinic

Mayo Clinic

Citations 3

Abstract 4147722: Clinical impact of new severe tricuspid regurgitation following device lead extraction
Mulpuru, Siva K. , Killu, Ammar M. , Siontis, Konstantinos, Cha, Yong‐Mei , Madhavan, Malini , ezzedine, fatima m, Sugrue, Alan , Padang, Ratnasari , Deshmukh, Abhishek , Karikalan, Suganya Arunachalam , O'Shea, Michael, Vemulapalli, Hema Srikanth , Kowlgi, Gurukripa N. , DeSimone, Christopher V. , Masry, Hicham El , Lee, Justin , Deshmukh, Abhishek

Circulation | November 14, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.4147722 Get It

Introduction: Tricuspid regurgitation (TR) is a common complication of right ventricle lead extraction (RVLE) in 5 to 10% of cases. This study aims to identify clinical outcomes such as predictors of heart failure hospitalization, need for tricuspid valve intervention, and death among patients with new severe TR after device lead removal (DLR). Methods: Patients who underwent DLR (pacemaker/ICD) between 3/1997 and 3/2024 were identified. Those who had an echocardiogram before and after RVLE with evidence of new severe TR were included. Cox univariable regression controlling for current age was used to assess association with death. Prentice Williams Peterson total time (PWPTT) Cox univariable regression was used to determine the rate of heart failure hospitalization up to three events per subject. Bivariable cox regression was used to control for ejection fraction for ICD and coil removal. Analysis was conducted using Stata IC16. Results: We identified 2,122 people who underwent RVLE, of whom 90 (4.24%) developed new severe TR and were included in the analysis. There were 68 hospitalizations among 38 people at a median of 2 years following lead extraction (IQR 0.57 to 4.5 years). The rate of hospitalization was 11.60 [9.14 to 14.71] per 100 person-years. Removal of an ICD was associated with increased hospitalization (HR 5.48 p<0.001) but not mortality (HR 1.21, p=0.707). Removal of a single coil ICD lead was associated with increased hospitalization rate (HR 3.01, p=0.031) but not mortality (HR =0.51, p=0.380). Removal of dual coil ICD lead was associated with more than a tenfold increase in hospitalization rate (HR 11.55, p=0.001) and four times the mortality rate (HR 4.05, p=0.031) (Figures 1&2). The presence of an abandoned (pacemaker/ICD) lead was associated with increased hospitalization (HR 5.75, p=0.004) and mortality (HR4.95, p=0.034). There was no change in hospitalization rate following tricuspid valve replacement (HR 1.33, p=0.716, n=18). Conclusion: Among people with new severe TR following DLR, the characteristics of the leads are strongly correlated with morbidity and mortality.
Safety and efficacy of ultra-long intermediate-power ablation for outflow tract ventricular arrhythmia arising from the left ventricular summit
Futela, Pragyat , Dai, Qiying , Gupta, Anuja, ezzedine, fatima m, Deshmukh, A J, Garg, Lohit , Siontis, Konstantinos C. , Kowlgi, Gurukripa Narayan, Kowlgi, Gurukripa N.

European Heart Journal | October 28, 2024 | Volume: 45 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehae666.686 Get It

Abstract Background Radiofrequency ablation (RFA) has been effective in managing premature ventricular contractions (PVCs). Despite improvement in ablation techniques, recurrence remains high for LV summit PVCs. Epicardial ablation here is often precluded due to fat and proximity to coronaries, thus, aggressive but safe endocardial options are needed. Purpose To evaluate the safety and effectiveness of ultra-long ablation (&gt;240 seconds) duration for refractory LV summit PVCs. Methods Patients with deep intramural LV summit PVCs were identified by lack of PVC elimination or late (&gt;60 s suppression) and recurrence post-lesion under the left aortic sinus of Valsalva. We included patients who received the longest RFA of at least 240 seconds (maximum 15 minutes). RFA power was titrated slowly from 20 to 35W, carefully ensuring that the impedance drop did not exceed 12 ohms. Acute procedure success was defined as clinical PVC suppression for ≥60 minutes after the last lesion. Short-term success was defined as symptom improvement, ejection fraction (EF) recovery, and drop in PVC burden at 3 months. Results Twenty patients (59.5 ± 16.4 years, 55% male) were included. Baseline features are shown in Table 1. All RFA were delivered endocardially. No steam pops were noted. PVC burden was significantly lower at 3-month follow-up (P&lt; 0.01), Figure 1A. Most patients had a normal ejection fraction (EF) at baseline; thus, no significant difference change in EF was observed (Figure 1B). One complication was recorded, which was tamponade likely caused by coronary sinus dissection requiring pericardiocentesis. Acute success was achieved in 95.0% of the cases, and all cases followed at 3 months (18/18) achieved short-term success. Conclusion Ultra-long duration RFA with lesions ≥ 240 seconds at 35W per lesion for LV summit PVCs appeared to be safe and effective in achieving acute and short-term success. The lack of acute suppression should not discourage operators, as there seems to be delayed suppression in some cases. Careful monitoring of biophysics is paramount when attempting this technique.
Ablation of right ventricular endocavitary arrhythmias
Ezzedine, F, Sugrue, Alan , Asirvatham, S J, Killu, Ammar M. , Haq, I, ezzedine, fatima m

European Heart Journal | October 28, 2024 | Volume: 45 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehae666.386 Get It

Abstract Background The right ventricular moderator band-papillary muscle (RV MB-PM) complex has a rich subendocardial network of purkinje fibers which can lead to ventricular arrhythmias (VA)1. Catheter ablation of such arrhythmias is procedurally challenging and there remains limited studies on long-term procedural success. Purpose We aimed to systematically study RV MB-PM complex VA. Methods A single center retrospective study from January 2013 to December 2023 identified 3249 patients who underwent VA ablation. The RV MB-PM complex was targeted in 47 patients. Acute success was defined as suppression of the targeted VA &gt;=30 minutes post ablation. Long-term success was defined as the absence of symptoms, total PVC burden &lt;5% or improvement in EF in patients presenting with isolated PVCs and as freedom from appropriate ICD therapy in patients presenting with malignant PVCs inducing VF, sustained VT or VT storm. Results Mean age was 51.9 ± 16.7 years and 64% were male. 40 (85%) patients had VA targeted from the MB and 7 (15%) from the PM complex (2 anterior, 2 inferior and 3 septal PM). 34 (72%) had no underlying structural heart disease, 3 (6%) ischemic cardiomyopathy and 10 (21%) non-ischemic cardiomyopathy. No patient had delayed gadolinium enhancement in the RV MB-PM complex. VA were inducible in 42 (89%) of patients and activation mapping was used in 9 (19%), pace mapping in 5 (11%) and a combination of activation and pace mapping used in 33 (70%) patients. Intracardiac echocardiography was used in all cases. Pre-QRS duration was 34.0 ± 10.4 ms. Radiofrequency ablation was used in 37 (78.7%) cases, cryotherapy in 4 (8.51%) cases and a combination of the 2 energy sources in 6 (12.8%) cases. In all cases, acute peri-procedural success was achieved. 24 (51.1%) patients presented with isolated PVCs and were followed up for 4.72 ± 3.55 years after their index procedure. 3 patients underwent repeat catheter ablation targeting the same PVC focus but all patients had long term success with a PVC burden of 16.1 ± 12.5% prior to ablation and 2.40 ± 2.44% at last follow-up. 16 patients underwent ablation for recurrent ICD shocks after initially presenting with PVC induced VF. Patients were followed up for 3.22 ± 2.09 years and 14 (88%) patients remained free from ICD therapy. 7 patients had MB ablation for sustained VT and were followed up for 4.06 ± 3.77 years. 5 (71%) patients remained free from ICD therapy. A purkinje potential was seen in 8% (2/24) cases of isolated PVCs and in 39% (9/23) cases of PVC induced VF or VT (p=0.13). Conclusions RV MB-PM VA commonly present with malignant VF and a purkinje potential is more likely to be seen in these cases suggesting different VA mechanisms to isolated PVCs and catheter ablation is an effective long-term strategy.