Summary Modular, porous-coated, titanium segmental endoprostheses were implanted bilaterally in the femoral diaphysis of 7 adult mixed-breed dogs. Autogenous bone graft in particle form was placed around the implant and bone. In 1 limb, homologous fibrin adhesive was mixed with the graft in situ before soft tissue closure. The contralateral limb was grafted in identical manner, but without fibrin adhesive, and served as a control. Radiography was performed immediately after surgery and 1, 2, 3, 4, 6, 8, 10, and 12 weeks later to assess callus area and bone remodeling. At 12 weeks, dogs were euthanatized and bone/implant fixation strength was tested under torsion and compared with values for 6 in vitro controls. Histomorphometric and microradiographic analyses of transverse sections of the distal portion of the implanted femurs were performed. Radiographic callus area was significantly (P < 0.05) smaller in the femurs grafted with fibrin adhesive, compared with the contralateral control. New bone formation (21.4 ± 1.8% vs 19.2 ± 2.4%), unlabeled bone (64.8 ± 3.0% vs 67.9 ± 4.2%), porosity (13.9 ± 0.7% vs 12.9 ± 0.8%), and bone ingrowth into the porous coating (10.3 ± 0.9% vs 10.0 ± 1.2%) were not significantly different between fibrin- and nonfibrin-grafted implants, respectively. There were no significant differences in torsional strength of implant fixation between the fibrin- and nonfibrin-grafted femurs or between the in vivo implanted femurs and the in vitro controls. These data indicate that fibrin adhesive may have been advantageous in maintaining apposition of bone graft adjacent to the endoprosthesis, but it probably did not have an enhancing effect on extracortical bone bridging or ingrowth over a porous-coated segmental bone replacement endoprosthesis.
Effect of titanium endoprostheses on bone mineral density measurements, using quantitative computed tomography
Summary Quantitative computed tomography has been used extensively to measure bone mineral density; particularly in the vertebral column and in the proximal portion of the femur in human beings with osteoporosis. Other potential applications of this technique include evaluation of bone adjacent to metallic endoprostheses and evaluation of fractures as they heal. Unfortunately, metal causes severe image degradation, principally seen as starburst streaking. One method used to decrease these artifacts is by imaging less-attenuating materials, such as titanium alloy. Titanium decreases image degradation sufficiently to allow accurate determination of the geometric properties of cadaveric bone. In our study, the effect of a titanium segmental endoprosthesis on bone mineral density measurement was determined by use of bone specimens from dogs and calibration standards. Titanium decreased the bone mineral density of calibration solutions from 6.8 (500 mg/cm3) to 17.7% (250 mg/cm3), and increased bone mineral density of cortical bone by 5.3%. Titanium did not affect the repeatability of these scans, indicating that the error caused by titanium was systematic and can be corrected. Our data were suggestive that quantitative computed tomography can be used to measure bone mineral density of cortical bone adjacent to titanium endoprostheses, with a predictable increase in density measurement.
Multiplanar quantitative computed tomography for bone mineral analysis in dogs
Summary The purpose of this study was to determine the precision and accuracy of quantitative computed tomography bone mineral analysis in dogs in coronally reconstructed images. Nonhomogeneous tissues, such as bones with fractures or deformities, may be better analyzed if multiplanar reconstruction of the transaxial data could be performed without degradation of information. Our analysis demonstrated that coronal reconstruction of quantitative-computed tomography data was precise (1.2 to 4.7%) and accurate (1.3 to 7.5%) in vitro. The technique displays high-quality images, which can be analyzed at any location within the volume scanned. Quantitative computed tomography of canine osteotomy healing in vivo accurately determined bone mineral density of selected regions of interest. Bone mineral density correlated highly with calcium content of the tissue (R2 = 0.76, P < 0.0001).
Beta-globin chain hemoglobin polymorphism and hemoglobin stability in black rhinoceroses (Diceros bicornis)
Summary To evaluate the syndrome of acute intravascular hemolytic anemia in black rhinoceroses (Diceros bicornis), the hemoglobin of this species was evaluated by use of isopropanol- and heat-stability tests and was further characterized by electrophoretic studies. Samples were obtained from 22 apparently healthy captive North American black rhinoceroses, though 3 of the study animals had survived previous hemolytic events, and 3 others were parents of 3 offspring that had suffered hemolysis. The eastern African (Diceros bicornis michaeli) and the southern African subspecies (D b minor) were represented. Comparative samples were also obtained from 2 white (Ceratotherium simum) and 1 Indian (Rhinoceros unicornis) rhinoceroses. The hemoglobin of all 3 species appeared stable when tested by use of the heat and isopropanol methods. Thus, an unstable hemoglobin does not appear to be involved in the hemolytic crises of captive black rhinoceroses. Black rhinoceros hemoglobin had a striking polymorphism. Thirteen of the samples from black rhinoceroses had a single hemoglobin band, based on results of alkaline electrophoresis. Nine had, in addition to this major band, a slow (more cathodic) minor band that comprised about 10% of the total hemoglobin. Further studies indicated that the major band and the slower minor band may contain globin chains analogous to human β- and δ-chains respectively; these bands have been tentatively designated B and C. Phenotypes B and BC are common, in a ratio of 4:3. A genetic mechanism is proposed that assumes βb, and βc, gene loci and that βc-locus-expressed (βc+) and βc,-locus-inhibited (βc°) are common alleles for the βc-locus. The polymorphism of rhinoceros hemoglobins appears to be unrelated to the acute hemolytic anemia that occurs in this species.
ImportanceImplementing multidisciplinary teams for treatment of complex brain tumors needing awake craniotomies is associated with significant costs. To date, there is a paucity of analysis on the cost utility of introducing advanced multidisciplinary standardized teams to enable awake craniotomies.ObjectiveTo assess the cost utility of introducing a standardized program of awake craniotomies.Design, Setting, and ParticipantsA retrospective economic evaluation was conducted at Mayo Clinic Florida. All patients with single, unilateral lesions who underwent elective awake craniotomies between January 2016 and December 2021 were considered eligible for inclusion. The economic perspective of the health care institution and a time horizon of 1 year were considered. Data were analyzed from October 2022 to May 2023.ExposureTreatment with an awake craniotomy before standardization (2016-2018) compared with treatment with awake craniotomy after standardization (2018-2021).Main Outcomes and MeasuresPatient demographics, perioperative, and postoperative outcomes, including length of stay, intensive care (ICU) admission, extent of resection, readmission rates, and 1-year mortality were compared between patients undergoing surgery before and after standardization. Direct medical costs were estimated from Medicare reimbursement rates for all billed procedures. A cost-utility analysis was performed considering differences in direct medical costs and in 1-year mortality within the periods before and after standardization of procedures. Uncertainty was explored in probability sensitivity analysis.ResultsA total of 164 patients (mean [SD] age, 49.9 [15.7] years; 98 [60%] male patients) were included in the study. Of those, 56 underwent surgery before and 108 after implementation of procedure standardization. Procedure standardization was associated with reductions in length of stay from a mean (SD) of 3.34 (1.79) to 2.46 (1.61) days (difference, 0.88 days; 95% CI, 0.33-1.42 days; P = .002), length of stay in ICU from a mean (SD) of 1.32 (0.69) to 0.99 (0.90) nights (difference, 0.33 nights; 95% CI, 0.06-0.60 nights; P = .02), 30-day readmission rate from 14% (8 patients) in the prestandardization cohort to 5% (5 patients) (difference, 9%; 95% CI, 19.6%-0.3%; P = .03), while extent of resection and intraoperative complication rates were similar between both cohorts. The standardized protocol was associated with mean (SD) savings of $7088.80 ($12 389.50) and decreases in 1-year mortality (dominant intervention). This protocol was found to be cost saving in 75.5% of all simulations in probability sensitivity analysis.Conclusions and RelevanceIn this economic evaluation of standardization of awake craniotomy, there was a generalized reduction in length of stay, ICU admission time, and direct medical costs with implementation of an optimized protocol. This was achieved without compromising patient outcomes and with similar extent of resection, complication rates, and reduced readmission rates.
OP18 Efficacy and safety of darvadstrocel treatment in patients with complex perianal fistulas and Crohn’s Disease: results from the global ADMIRE-CD II phase 3 study
Abstract Background Complex perianal fistulas are a serious complication in patients with Crohn’s disease (CD). Darvadstrocel (DVS), a suspension of expanded adult allogeneic adipose-derived mesenchymal stem cells, is approved in Europe and Japan for treatment of complex Crohn’s perianal fistulas (CPF). The global ADMIRE-CD II phase 3 randomized double-blind placebo-controlled study evaluated the efficacy and safety of DVS for treatment of complex CPF. Methods Patients aged 18–75 years with clinically controlled, inactive or mildly active CD and complex CPF (≤2 internal openings [IO] and ≤3 external openings [EOs]) who had an inadequate, or a loss of response to immunosuppressive agents or biologics were included. Patients were randomized 1:1 to receive a local injection of DVS as a single dose (120 x 106 cells/24 mL) or placebo. In all patients, fistula preconditioning included vigorous curettage and seton placement 2–3 weeks before treatment, and seton removal, a further curettage and closure of IOs immediately before treatment. The primary endpoint was combined remission (closure of all treated EOs that were draining at baseline, despite gentle finger compression, and absence of collections >2 cm confirmed by MRI) at 24 weeks. Secondary endpoints included combined remission at 52 weeks, clinical remission (closure of all treated EOs without MRI confirmation) at 24 and 52 weeks, and time to clinical remission at 24 weeks. Safety was monitored up to 52 weeks. Results From 19 Oct 2017 to 26 Jul 2023, 568 patients received DVS (n = 283) or placebo (n = 285) with fistula preconditioning; 56.3% of patients enrolled in Europe and Israel, and 43.7% in North America. Mean (SD) age, sex and race were similar in the DVS and placebo arms (38.4 [11.9] vs 37.7 [10.8] years; 42.8% vs 45.6% female; 85.9% vs 89.1% White). Combined remission rates at 24 weeks did not statistically differ between treatments (48.8% DVS vs 46.3% placebo) and there were no differences in secondary endpoints (Table 1; Figure 1). Based on health authority guidelines, post hoc analyses of patients randomized before COVID-19 (11 March 2020; n = 141 DVS, n = 143 placebo) were performed: combined remission rates at 24 weeks were 46.8% (DVS) and 38.5% (placebo). The safety profile for DVS was consistent with prior studies with no new safety signals (Table 1). Conclusion The efficacy outcomes assessed did not statistically differ between DVS and placebo, and the placebo response rate (with fistula preconditioning) was higher than expected. Post hoc analyses revealed lower placebo response rates in patients randomized before COVID-19 (similar to the pivotal ADMIRE CD I study) than the overall placebo arm. DVS was well tolerated.
Closing the gap: improving the percentage of Annual Wellness Visits among Medicare patients
Background The Medicare Annual Wellness Visit (AWV) allows providers to acquire critical information about patients’ health through a review of vitals, environmental risks, and medical and family history. These visits are free to those enrolled in Medicare and prioritize patient–provider relationship building and preventative care. Despite this, AWV completion rates are suboptimal. Methods A quality improvement project was aimed to increase the percentage of AWVs among Medicare patients in a primary care internal medicine practice from a baseline of 1.7% completion to 2.7% in 3 months from January to April 2023. Intervention With eligible patients identified, a standardized approach was created where an AWV appointment was ordered, and a patient message explaining the benefit of the appointment was sent by the patient portal. Results Our AWV intervention resulted in 72 patients being seen for an AWV, which increased the percentage of completed AWVs in the division by 2.1% from 1.7% to 3.8% in 3 months. Conclusion This intervention will continue to improve AWV rates and improve patient care for Medicare patients in internal medicine. It could be applied to other areas of primary care and within other health systems.
The Impact of Polypill on Adherence and Cardiovascular Outcomes:
A Comprehensive Systematic Review with Meta-Analysis
Background: Cardiovascular disease (CVD) remains a leading cause of morbidity and mortality worldwide. Polypills, containing various combinations of medications for primary and secondary CVD prevention, have been developed to enhance medication adherence and reduce the healthcare burden of CVD. However, their effectiveness compared to usual care remains uncertain. Objective: This meta-analysis aimed to evaluate the effects of polypills on cardiovascular risk factors, major adverse cardiovascular events (MACE), and medication adherence. Methods: We conducted a comprehensive search for large-scale randomized controlled trials and observational studies comparing the effects of polypills versus usual care on CVD risk factors and events. Outcomes included changes in systolic and diastolic blood pressure (SBP, DBP), lipid profiles, occurrence of MACE, and medication adherence. Results: The use of polypills led to a statistically significant yet clinically modest reduction in SBP (mean difference -1.47 mmHg, 95% CI: -2.50 - -0.44, p<0.01) and DBP (mean difference1.10 mmHg, 95% CI: -1.68 - -0.51, p< 0.01) compared to usual care. Polypills also showed a significant reduction in the risk of MACE (RR: 0.86, 95% CI: 0.77 -0.95, p<0.01). There was a non-significant reduction in LDL and HDL levels. Adherence to medication improved by up to 17% in polypill users compared to those on usual care (p < 0.01). A multivariable metaregression analysis suggested that adherence may be the underlying factor responsible for the observed effect of the polypills on blood pressure. Conclusion: Polypills were found to significantly reduce SBP, DBP and MACE. An improvement in medication adherence was also observed among polypill users, which might be responsible for the significant reduction in SBP observed users. Future research might benefit from exploring a more personalized approach to the composition of polypills, which could reveal a more clinically significant impact of increased adherence on CVD outcomes.
The Use of Magnetic Resonance Imaging in Radiation Therapy Treatment Simulation and Planning
Ever since its introduction as a diagnostic imaging tool the potential of magnetic resonance imaging (MRI) in radiation therapy (RT) treatment simulation and planning has been recognized. Recent technical advances have addressed many of the impediments to use of this technology and as a result have resulted in rapid and growing adoption of MRI in RT. The purpose of this article is to provide a broad review of the multiple uses of MR in the RT treatment simulation and planning process, identify several of the most used clinical scenarios in which MR is integral to the simulation and planning process, highlight existing limitations and provide multiple unmet needs thereby highlighting opportunities for the diagnostic MR imaging community to contribute and collaborate with our oncology colleagues.Evidence Level5Technical EfficacyStage 5