Citations

Mayo Clinic

Clear

37 citation(s) found for "Vaidya, Vaibhav".

Activation pattern during his pacing: how close are we to normal physiology?
Yasin, Omar , Vaidya, Vaibhav R. , Tri, Jason , Zyl, Martin van , Ladejobi, Adetola, Scheuermann, Carolin, Bush, J , Taubel, R, Pedersen, Joanne, Yngsdal, Lisa, Asirvatham, S, Cha, Y, Xiao, Ping , Han, Jin

European Heart Journal | November 26, 2020 | Volume: 41 | Issue: Supplement_2 | Pages: No page available

10.1093/ehjci/ehaa946.0804 Get It

Abstract Background His bundle pacing aims to mimic the activation pattern of normal conduction to maintain ventricular synchrony. However, selective His capture can be challenging, and the activation sequence during His pacing may not replicate normal conduction. Purpose Compare the right ventricular (RV) and left ventricular (LV) activation pattern in sinus rhythm and His bundle pacing. Methods Baseline LV and RV map was created in sinus rhythm using Rhythmia mapping system (Boston Scientific Corporation) in canine animal model. Medtronic 3830 lead was placed near the bundle of His under fluoroscopic, intracardiac echocardiogram, and electroanatomic guidance. Conduction system capture was confirmed by observing a QRS duration <120ms and an isoelectric segment between pacing artifact and QRS on surface ECG. Repeat LV and RV activation map was obtained during His pacing. Average QRS, HV and pacing to V intervals were calculated with standard deviation. Results Mapping was performed successfully in four animals. At baseline, the average QRS duration was 44±2.6ms and HV interval was 32±4.2ms. Earliest site of myocardial activation was in the mid-septal LV region. The earliest RV myocardial activation was also at the septum closer to the apex, but later than the LV (Figure1A). With His pacing, the average QRS duration was 70±17.0ms and the average stim to V interval was 31±8.7ms. During His pacing, the earliest site of activation was in the RV septum, with an activation pattern from base to apex in both the RV and LV. Conclusion Unlike normal physiology, the activation pattern during conduction system pacing is from base to apex with earliest site in the RV. Funding Acknowledgement Type of funding source: Public hospital(s). Main funding source(s): Mayo Clinic
Injectable conductive hydrogel restores conduction through ablated myocardium
Zyl, Martin van , Pedrotty, Dawn , Kuzmenko, Volodymyr , Sämfors, Sanna, Livia, Christopher , Vaidya, Vaibhav R. , Sugrue, Alan , Behfar, Atta , Asirvatham, Samuel J. , Gatenholm, Paul , Kapa, Suraj , van Zyl, Martin , Livia, Christopher , Vaidya, Vaibhav , Sugrue, Alan , Asirvatham, Samuel J , Gatenholm, Paul , Kapa, Suraj , Behfar, Atta , Karabulut, Erdem , McLeod, Christopher J.

Journal of Cardiovascular Electrophysiology | September 23, 2020 | Volume: 31 | Issue: 12 | Pages: 3293-3301

10.1111/jce.14762 | PMID 32966655 Get It

AbstractIntroductionTherapies for substrate‐related arrhythmias include ablation or drugs targeted at altering conductive properties or disruption of slow zones in heterogeneous myocardium. Conductive compounds such as carbon nanotubes may provide a novel personalizable therapy for arrhythmia treatment by allowing tissue homogenization.MethodsA nanocellulose carbon nanotube‐conductive hydrogel was developed to have conduction properties similar to normal myocardium. Ex vivo perfused canine hearts were studied. Electroanatomic activation mapping of the epicardial surface was performed at baseline, after radiofrequency ablation, and after uniform needle injections of the conductive hydrogel through the injured tissue. Gross histology was used to assess distribution of conductive hydrogel in the tissue.ResultsThe conductive hydrogel viscosity was optimized to decrease with increasing shear rate to allow expression through a syringe. The direct current conductivity under aqueous conduction was 4.3 × 10−1 S/cm. In four canine hearts, when compared with the homogeneous baseline conduction, isochronal maps demonstrated sequential myocardial activation with a shift in direction of activation to surround the edges of the ablated region. After injection of the conductive hydrogel, isochrones demonstrated conduction through the ablated tissue with activation restored through the ablated tissue. Gross specimen examination demonstrated retention of the hydrogel within the tissue.ConclusionsThis proof‐of‐concept study demonstrates that conductive hydrogel can be injected into acutely disrupted myocardium to restore conduction. Future experiments should focus on evaluating long‐term retention and biocompatibility of the hydrogel through in vivo experimentation.
Trends in reported industry payments to physicians practicing cardiac electrophysiology from 2013 to 2018 in the United States
Tseng, Andrew S. , Hu, Tiffany , Lee, Justin Z. , Amin, Mustapha, Vaidya, Vaibhav R. , Deshmukh, Abhishek , Madhavan, Malini , Cha, Yong‐Mei , Asirvatham, Samuel J. , Mulpuru, Siva K. , Hu, Tiffany Y, Vaidya, Vaibhav , Tseng, A S , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | September 21, 2020 | Volume: 31 | Issue: 12 | Pages: 3106-3114

10.1111/jce.14754 | PMID 32955151 Get It

AbstractIntroductionThe need for transparency in financial relationships in the healthcare system, has culminated in Open Payments database, managed by the Center for Medicare and Medicaid Services (CMS). Since its inception in 2013, the trend in such payments to physicians practicing cardiac electrophysiology was not examined.Methods and ResultsPayment information reported to CMS from January 2013 to December 2018 was obtained from the publicly available Open Payments data set using the online query tool. The data were analyzed by an individual provider and by state. An in‐depth analysis of payments in the year 2018 payments was performed. From 2014 to 2018, there was an 18% increase in the total number of payments reported from 88 877 payments in 2014 to 105 000 in 2018. Despite the increase in the total number of payments reported, the average payment steadily decreased over time, resulting in an overall reduction in the total amount of payments from 2014 to 2018 ($34.9 million to $28.2 million). Payments to the top 5% of individual recipients have also decreased over this time. In 2018, 2888 unique providers received reportable payments, a total of 105 000 payments, with a median payment amount of $1378 (interquartile range: $165–$5781). The majority of these payments were for food and beverage (82%) and travel/lodging (10%). The top five payers include Boston Scientific, Medtronic Vascular, Abbott Laboratories, Janssen Pharmaceuticals, and Biotronik.ConclusionAmong cardiac electrophysiologists, there is increased reporting of payments in the Open Payments program over time, with a notable decrease in the payment amount.
Incremental benefit of a novel signal recording system during mapping and ablation
Padmanabhan, Deepak , Sugrue, Alan , Vaidya, Vaibhav R. , Witt, Chance M. , Yasin, Omar , Naksuk, Niyada , Killu, Ammar M. , Foxall, T., Drakulic, Budimir , Venkatachalam, K, Asirvatham, Samuel J. , Vaidya, Vaibhav, Witt, Chance, Killu, Ammar, Venkatachalam, Kalapathi Lakshminarayana, Asirvatham, Samuel J , Foxall, Thomas

EP Europace | August 10, 2020 | Volume: 23 | Issue: 1 | Pages: 130-138

10.1093/europace/euaa194 | PMID 33094311 Get It

Abstract Aims Current electrophysiology signal recording and mapping systems have limited dynamic range (DR) and bandwidth, which causes loss of valuable information during acquisition of cardiac signals. We evaluated a novel advanced signal processing platform with the objective to obtain and assess additional information of clinical importance. Methods and results Over 10 canines, we compared intracardiac recordings within all cardiac chambers, in various rhythms, in pacing and during radiofrequency (RF) ablation across two platforms; a conventional system and the PURE EP™ [(PEP); Bio Sig Technologies, Inc., Los Angeles, CA, USA]. Recording cardiac signals with varying amplitudes were consistently and reproducibly observed, without loss of detail or introduction of artefact. Further the amplitude of current of injury (COI) on the unipolar signals correlated with the instantaneous contact force (CF) recorded on the sensing catheter in all the animals (r2 = 0.94 in ventricle). The maximum change in the unipolar COI correlated with the change in local electrogram amplitude during non-irrigated RF ablation (r2 = 0.61 in atrium). Reduction in artefact attributable to pacing (20 sites) and noise during ablation (48 sites) was present on the PEP system. Within the PEP system, simultaneous display of identical signals, filtered differently, aided the visualization of discrete conduction tissue signals. Conclusion Compared to current system, the PEP system provided incremental information including identifying conduction tissue signals, estimates of CF and a surrogate for lesion formation. This novel signal processing platform with increased DR and minimal front-end filtering may be useful in clinical practice.
Burden of Arrhythmia in Hospitalized HIV Patients
Abudan, Anas , Vaidya, Vaibhav, Tripathi, Byomesh , Egbe, Alexander , Arora, Shilpkumar , Sridhar, Haarini , DeSimone, Christopher V. , Mulpuru, Siva K. , Deshmukh, Abhishek , DeSimone, Christopher V , Noseworthy, Peter A. , DeSimone, Daniel C.

No container title available | July 16, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.159493215.58844465 Get It

Background: The improved life expectancy observed in patients living with Human Immunodeficiency Virus (HIV) infection has made age-related cardiovascular complications, including arrhythmias, a growing health concern. We describe the temporal trends in frequency of various arrhythmias and assess impact of arrhythmias on hospitalized HIV patients using the Nationwide Inpatient Sample (NIS) Methods and Results: Data on HIV-related hospitalizations from 2005 to 2014 were obtained from the NIS using International Classification of Diseases, 9th Revision (ICD-9) codes. Data was further subclassified into hospitalizations with associated arrhythmias and those without arrhythmia. Baseline demographics and comorbidities were determined. Outcomes including in-hospital mortality, cost of care, and length of stay were extracted. SAS 9.4 (SAS Institute Inc., Cary, North Carolina) was utilized for analysis. A multivariable analysis was performed to identify predictors of arrhythmias among hospitalized HIV patients. Among 2,370,751 HIV-related hospitalizations identified, the overall frequency of any arrhythmia was 3.01%. Atrial fibrillation (AF) was the most frequent arrhythmia (2110 per 100,000). The overall frequency of arrhythmias has increased over time by 108%, primarily due to a 132% increase in AF. Arrhythmias are more frequent among older males, lowest income quartile and non-elective admissions. Patients with arrhythmias had a higher in-hospital mortality rate (9.6%). In-hospital mortality among patients with arrhythmias has decreased over time by 43.8%. The cost of care and length of stay associated with arrhythmia-related hospitalizations were mostly unchanged. Conclusions: Arrhythmias are associated with significant morbidity and mortality in hospitalized HIV patients. AF is the most frequent arrhythmia in hospitalized HIV patients.
Injectable conductive hydrogel restores conduction through ablated myocardium
Zyl, Martin van , Pedrotty, Dawn , Karabalut, Erdem, mfors, Sanna S, Livia, Chris, Vaidya, Vaibhav R. , Sugrue, Alan , Gatenholm, Paul , Kuzmenko, Volodymyr , Livia, Christopher , McLeod, Christopher J. , Behfar, Atta , Asirvatham, Samuel J. , Kapa, Suraj

No container title available | July 6, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.159406900.02369826 Get It

Abstract Introduction: Therapies for substrate-related arrhythmias include ablation or drugs targeted at altering conductive properties or disruption of slow zones in heterogeneous myocardium. Conductive compounds such as carbon nanotubes may provide a novel personalizable therapy for arrhythmia treatment by allowing tissue homogenization. Methods: A nanocellulose-carbon nanotube conductive hydrogel was developed to have conduction properties similar to normal myocardium. Ex vivo perfused canine hearts were studied. Electroanatomic activation mapping of the epicardial surface was performed at baseline, after radiofrequency ablation, and after uniform needle injections of the conductive hydrogel through the injured tissue. Gross histology was used to assess distribution of conductive hydrogel in the tissue. Results: The conductive hydrogel viscosity was optimized to decrease with increasing shear rate to allow expression through a syringe. The DC conductivity under aqueous conduction was 4.3·10-1 S/cm. In 4 canine hearts, when compared to the homogeneous baseline conduction, isochronal maps demonstrated sequential myocardial activation with a shift in direction of activation to surround the edges of the ablated region. After injection of conductive hydrogel, isochrones demonstrated conduction through the ablated tissue with activation similar to baseline in all 4 hearts. Gross specimen examination demonstrated retention of the hydrogel within the tissue. Conclusions: This proof-of-concept study demonstrates that conductive hydrogel can be injected into acutely disrupted myocardium to restore conduction. Future experiments should focus on evaluating long-term retention and biocompatibility of the hydrogel through in vivo experimentation.
Injectable Flexible Subcutaneous Electrode Array Technology for Electrocardiogram Monitoring Device
Bong, Jihye , Yasin, Omar , Vaidya, Vaibhav R. , Park, Jeongpil , Padmanabhan, Deepak , Cho, Sang June , Asirvatham, Roshini, Schneider, Noah, Lee, Juhwan , Kim, Eun‐Mee , Friedman, Paul A. , Cho, Sang June , Lee, Juhwan , Ma, Zhenqiang , Attia, Zachi I.

ACS Biomaterials Science & Engineering | October 26, 2019 | Volume: 6 | Issue: 5 | Pages: 2652-2658

10.1021/acsbiomaterials.9b01102 | PMID 33463304 Get It

Incidence and Natural History of Left Bundle Branch Block Induced Cardiomyopathy
Barake, Walid , Witt, Chance M. , Vaidya, Vaibhav R. , Cha, Yong‐Mei

Circulation: Arrhythmia and Electrophysiology | September 12, 2019 | Volume: 12 | Issue: 9 | Pages: No page available

10.1161/circep.119.007393 | PMID 31510788 Get It

Epicardial access: Adjusting the approach as we discover complications
Vaidya, Vaibhav R. , Asirvatham, Samuel J. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | June 21, 2019 | Volume: 30 | Issue: 8 | Pages: 1341-1344

10.1111/jce.14036 | PMID 31222891 Get It

Comparing the incidence of ventricular arrhythmias during epicardial ablation in swine versus canine models
Caluori, Guido , Wojtaszczyk, Adam , Yasin, Omar , Pešl, Martin , Wolf, Jiří , Bělašková, Silvie , Crha, Michal, Sugrue, Alan , Vaidya, Vaibhav R. , Naksuk, Niyada , Killu, Ammar M. , Padmanabhan, Deepak , Asirvatham, Samuel J. , Stárek, Zdeněk , DeSimone, Christopher V , Killu, Ammar M , Stárek, Zdeněk , Asirvatham, Samuel J , DeSimone, Christopher V.

Pacing and Clinical Electrophysiology | April 16, 2019 | Volume: 42 | Issue: 7 | Pages: 862-867

10.1111/pace.13698 | PMID 30989679 Get It

Abstract Background Choosing the appropriate animal model for development of novel technologies requires an understanding of anatomy and physiology of these different models. There are little data about the characteristics of different animal models for the study of technologies used for epicardial ablation. We aimed to compare the incidence of ventricular arrhythmias during epicardial radiofrequency ablation between swine and canine models using novel epicardial ablation catheters. Methods We conducted a retrospective study using data obtained from epicardial ablation experiments performed on swine ( Sus Scrofa ) and canine ( Canis familiaris ) models. We compared the incidence of ventricular arrhythmias during ablation between swine and canine using multivariate regression analysis. Six swine and six canine animals underwent successful epicardial radiofrequency ablation. A total of 103 ablation applications were recorded. Results Ventricular arrhythmias requiring cardioversion occurred in 13.11% of radiofrequency ablation applications in swine and 9.75% in canine (relative risk: 117.6%, 95% confidence interval [CI]: 83.97‐164.69, animal‐based odds ratio [OR]: .55, 95% CI: .23‐61.33; P = .184). When adjusting for application position, duration of ablation and power, the odds of developing potentially lethal ventricular arrhythmia in swine increased significantly compared to canine (OR: 3.60, 95% CI: 1.35‐9.55; P = .010). Conclusions The swine myocardium is more susceptible to developing ventricular arrhythmias compared to canine model during epicardial ablation. This issue should be carefully considered in future studies.