Abstract Background His bundle pacing aims to mimic the activation pattern of normal conduction to maintain ventricular synchrony. However, selective His capture can be challenging, and the activation sequence during His pacing may not replicate normal conduction. Purpose Compare the right ventricular (RV) and left ventricular (LV) activation pattern in sinus rhythm and His bundle pacing. Methods Baseline LV and RV map was created in sinus rhythm using Rhythmia mapping system (Boston Scientific Corporation) in canine animal model. Medtronic 3830 lead was placed near the bundle of His under fluoroscopic, intracardiac echocardiogram, and electroanatomic guidance. Conduction system capture was confirmed by observing a QRS duration <120ms and an isoelectric segment between pacing artifact and QRS on surface ECG. Repeat LV and RV activation map was obtained during His pacing. Average QRS, HV and pacing to V intervals were calculated with standard deviation. Results Mapping was performed successfully in four animals. At baseline, the average QRS duration was 44±2.6ms and HV interval was 32±4.2ms. Earliest site of myocardial activation was in the mid-septal LV region. The earliest RV myocardial activation was also at the septum closer to the apex, but later than the LV (Figure1A). With His pacing, the average QRS duration was 70±17.0ms and the average stim to V interval was 31±8.7ms. During His pacing, the earliest site of activation was in the RV septum, with an activation pattern from base to apex in both the RV and LV. Conclusion Unlike normal physiology, the activation pattern during conduction system pacing is from base to apex with earliest site in the RV. Funding Acknowledgement Type of funding source: Public hospital(s). Main funding source(s): Mayo Clinic
P2862Complementary use of contact force and local catheter impedance during RF ablation reduces ablation time in an in vivo swine model
Abstract Catheter-tissue coupling is crucial for effective delivery of radiofrequency (RF) energy during catheter ablation. Force sensing catheters provide a metric of mechanical tissue contact and catheter stability, while local impedance has been shown to provide sensitive information on real-time tissue heating. The complementary use of force and local impedance during RF ablation procedures could provide an advantage over the use of one metric alone. This study evaluates a prototype ablation catheter that measures both contact force (CF) using inductive sensors and local catheter impedance (LI) using only catheter electrodes. The complementary nature was assessed with discrete lesions in vitro and an intercaval line in vivo. A force-sensing catheter with LI was evaluated in explanted swine hearts (n=14) in an in vivo swine model (n=9, 50–70kg) using investigational electroanatomical mapping software. In vitro, discrete lesions were created in ventricular tissue at a range of forces (0–40g) controlled externally. RF energy was applied at a range of powers (20W, 30W, and 40W), durations (10s-60s), and catheter orientations (0°, 45°, and 90°). Lesions were stained with TTC and measured. LI drop relative to baseline during RF in the bench studies was used to inform the in vivo study. In a separate subset of animals in vivo, an intercaval line was created in three experimental groups: LI blinded, 20Ω ΔLI, and 30Ω ΔLI. CF was maintained between 15 and 25g in all groups. All ablations were performed with a power of 30W. In the LI blinded group, all lesions were delivered for 30s. In the 20Ω ΔLI group, the investigator ablated until a 20Ω drop or 30 seconds was achieved. Likewise, in the 30Ω ΔLI, the investigator ablated until a 30Ω drop or 30 seconds was achieved. In vitro, 137 discrete ventricular lesions were created. LI drop during ablation correlated strongly with lesion depth using a monoexponential fit (R=0.84) while force time integral (FTI) did not correlate as strongly (R=0.56). In the intercaval LI blinded group, starting LI ranged from 126–163Ω with a median of 138Ω. LI drops ranged from 13Ω-44Ω, with a median of 26Ω. In the 20Ω ΔLI group, starting LI ranged from 137–211Ω with a median of 161Ω and LI drop ranged from 7Ω-35Ω, with a median of 22Ω. In the 30Ω ΔLI group, starting LI ranged from 130–256Ω with a median of 171Ω and LI drop ranged from 20Ω-52Ω, with a median of 31Ω. Notably, RF time for the LI blinded group was 13±0.1 minutes while RF time in the 20Ω ΔLI group was 6.4±1.9 minutes and 7.5±0.7 minutes in the 30Ω ΔLI group. A catheter incorporating CF-sensing and LI capabilities provides a powerful tool for RF ablation. Bench studies demonstrate a strong correlation between LI drop and lesion dimensions, which guided the use of LI in vivo. In vivo, the confirmation of stable mechanical contact and viewing of real-time LI drops enabled a significant reduction in RF time while creating a continuous intercaval line. Acknowledgement/Funding This study was funded by Boston Scientific.