Citations

Mayo Clinic

Clear

343 citation(s) found for "Asirvatham, Samuel J".

Abstract 2500: Paroxysmal Atrial Fibrillation Detected By Prolonged Ambulatory Cardiac Monitoring In Patients With Cryptogenic Stroke: A Case-Control Study
Fugate, Jennifer E. , Mandrekar, Jay , Asirvatham, Samuel, Friedman, Paul A. , Rabinstein, Alejandro A. , Seet, Raymond C.S.

Stroke | March 20, 2022 | Volume: 43 | Issue: suppl_1 | Pages: No page available

10.1161/str.43.suppl_1.a2500 Get It

Background: Whether a significant proportion of cryptogenic stroke (CS) is caused by under-detected paroxysmal atrial fibrillation (PAF) is not known. Prolonged ambulatory cardiac monitoring may detect episodes of PAF in patients with stroke of unknown cause (cryptogenic stroke, CS). However, it is unclear whether PAF is more common in patients wtih CS compared with patients with stroke of known cause (SKC). We performed a case control study to compare the rates of detection of PAF in CS vs SKC using prolonged ambulatory cardiac rhythm monitoring. Methods and Results: We prospectively enrolled 132 patients within 3 months of a stroke (66 with CS and 66 with SKC) to undergo 3-week ambulatory cardiac rhythm monitoring using the CardioNet MCOT system. Stroke group was assigned by consensus between two vascular neurologists upon enrollment based on the Causative Classification of Stroke system. Primary endpoint was detection of PAF of any duration independently confirmed by two cardiologists blinded to the stroke group. The groups were well balanced except that patients with CS tended to be older and to have less hypertension and diabetes. Four patients (2 in each group) were excluded because of insufficient stroke evaluation or early discontinuation of monitoring. Episodes of PAF were detected in 16/64 (25%) patients with CS and 9/64 (14%) patients with SKC (p=0.12). Only 5 patients had episodes of PAF lasting > 30 seconds (3 with CS and 2 with SKC). Six of the 9 patients from the SKC group with PAF had small subcortical infarctions; the other 3 had cortical strokes ascribed to artery-to-artery embolism (2 with complex aortic plaques, 1 with severe vertebrobasilar stenosis). In patients under age 65, episodes of PAF were more common in the CS group (22% vs 3; p=0.07) while in patients age 65 or older the rates of detection were very similar (29% in CS vs 28% in SKC; p=0.9). Conclusions: Very short episodes of PAF are relatively common in patients with CS and with SKC, and their pathogenic significance is unclear. However, considering only patients under 65, a greater proportion of cryptogenic stroke patients had PAF, suggesting it might be pathogenic.
Abstract 55: Use of a Novel Electrogram Filter to Visualise the Conduction Tissue Signals in the Ventricle in Sinus Rhythm and Arrhythmia: Canine Studies
Padmanabhan, Deepak , Witt, Chance M. , Sugrue, Alan , Killu, Ammar M. , Naksuk, Niyada , Ladewig, Dorothy J., Powers, Joanne, Suddendorf, Scott H., DeSimone, Christopher V. , Asirvatham, Samuel J.

Circulation Research | March 20, 2022 | Volume: 121 | Issue: suppl_1 | Pages: No page available

10.1161/res.121.suppl_1.55 Get It

Background: Conduction tissue in the ventricles is closely intertwined with myocardium. Owing to high velocity of conduction, there is near simultaneous activation , making it difficult to discern. Restricted sampling rates and limited dynamic range make real time signal processing challenging for these signals in routine recording systems. Objectives: We aimed to use novel signal processing techniques in a new system to isolate the conduction tissue signals from the rest of the myocardial activation. Methods: We used the PURE-EP™ (BioSig Technologies, MN) signal processing system to record endocardial and epicardial signals from 6 anesthetized canines in an acute study setting. A novel filter based on proprietary algorithms to isolate the high frequency signal was applied at sites where the electrogram signals were thought to have a conduction tissue component to them. . In addition, ventricular fibrillation (VF) was induced at the end of the experiment and signals were then recorded from the endocardium and the conduction system. Results: This filter was successfully able to isolate conduction tissue signals in the myocardium from those of the ventricular muscle. It did over sense atrial signals at the basal left ventricular septum owing to the high frequency components of the atrial signal at this location. When applied to epicardial signals, it did not pick up any conduction tissue signals. In VF, we could discern signals originating from the conduction system endocardially. (Figure 1) Conclusions: This filter can isolate conduction tissue signals from those of the myocardium and may prove to be a useful adjunct in mapping arrhythmias originating near the conduction system.
Abstract 371: Assessment of Catheter Position Above or Below the Aortic Valve by Evaluation of Characteristics of the Local Electro Gram: an Acute Canine Study
Pa, Deepak, Witt, Chance M. , Sugrue, Alan , Suddendorf, Scott H., Powers, Joanne, Ladewig, Dejae, Drakulic, Budimir , Foxall, Thomas, LADEWIG, DEJAE J., Asirvatham, Samuel J.

Circulation Research | March 20, 2022 | Volume: 121 | Issue: suppl_1 | Pages: No page available

10.1161/res.121.suppl_1.371 Get It

Background: Ablation in the sinuses of Valsalva (SoV) within the aorta is fraught with risk, owing to the proximity of the coronary arteries. Assessment of catheter tip position is not very easy at this location owing to complex local anatomy and poor images from available modalities. Objectives: We propose the use of novel local unipolar electrogram characteristics using a new signal recording system to guide the assessment of catheter tip position in this region. Methods: We recorded unipolar signals from above the SoV, within the coronaries and below the SoV using the PURE-EP™ (BioSig Technologies, MN) signal processing system in 4 anesthetized canines in the setting of an acute study. We used fluoroscopy, intracardiac echocardiography and angiography for confirmation of the position of the catheter tip. We recorded changes in the signals when transitioning between (1) the coronary arteries and the SoV and (2) the SoV and below the SoV. Results: The unipolar signal showed a negative current of injury (COI) when the catheter tip was present in the SoV, whereas within the coronary artery or below the SoV, the COI was positive. We propose that the difference in the distribution of ventricular muscle below and above the SoV is responsible for this phenomenon. These changes in the COI were noted immediately when transitioning from one location to another and were present reproducibly in all the dogs. ( Figure 1 ) Conclusions: Analysis of the changes on the local electrogram can provide information about the location of the catheter tip which could prove critical in saving lives.
Abstract 344: Optimal Serum Potassium, Calcium and Magnesium in the Coronary Care Unit
Krittanawong, Chayakrit , Park, Jae Y, Sharma, Sunita , Gaba, Prakriti , Rosenbaum, Andrew , Hu, Tiffany , Bell, Malcolm R. , Brady, Peter A. , Naksuk, Niyada , Krittanawong, Chayakrit , Thongprayoon, Charat , Herasevich, Vitaly , Kapa, Suraj , Asirvatham, Samuel J.

Circulation: Cardiovascular Quality and Outcomes | March 20, 2022 | Volume: 8 | Issue: suppl_2 | Pages: No page available

10.1161/circoutcomes.8.suppl_2.344 Get It

Background: It is known that hypokalemia, hypocalcemia and hypomagnesemia cause a prolonged QTc interval and are associated with an increased risk of ventricular arrhythmias. However, there are limited data on optimal serum electrolytes for patients admitted to the coronary care unit (CCU). Objective: Here, we aimed to evaluate the relationship between serum potassium, ionized calcium and magnesium levels and in-hospital mortality in the CCU setting. Methods: This retrospective cohort study included 8,498 consecutive patients admitted to the CCU at an academic tertiary medical center from 2004 through 2013. The mean of serum electrolytes was categorized as <3.5, 3.5-<4.0, 4.0-<4.5 (reference), 4.5-<5.0, and ≥5.0 mEq/L for potassium; <4.4, 4.4-<4.6, 4.6-<4.8, 4.8-<5.0 (reference), and ≥5.0 mg/dL for ionized calcium; and <1.8, 1.8-<2.0, 2.0-<2.2 (reference), 2.2-<2.4, and ≥2.4 mg/dL for magnesium. Multivariate logistic regression analysis was used to determine the association between the mean of serum electrolytes and in-hospital mortality. Results: Of the 8,498 patients, 599 (7%) died during hospitalization. Relationship between mean serum potassium (U-shaped), ionized calcium (inverted J-shape) and magnesium (J-shaped) and in-hospital mortality was present in Figure. Serum potassium levels <3.5, 4.5-<5.0 and ≥5.0 mEq/L were independently associated with an increased risk of in-hospital mortality (adjusted OR 1.7 95% CI 1.1-2.5, OR 1.7 95% CI 1.3-2.2, and OR 3.4 95% CI 2.4-4.8, respectively), compared to the reference group. As for serum ionized calcium, the levels of <4.4, 4.4-<4.6, and 4.6-<4.8 mg/dL independently increased risk of mortality (adjusted OR 3.0 95% CI 2.3-4.0, OR 2.0 95% CI 1.5-2.6, and OR 1.4 95% CI, 1.1-1.8, respectively). As for serum magnesium, an only level above 2.4 mg/dL was associated with an increased mortality risk (OR 1.6 95% CI, 1.1-2.2). Conclusions: In the CCU setting, serum potassium 3.5-<4.5 mEq/L, ionized calcium ≥5.0 mg/dL and magnesium <2.4 mg/dL are associated with the lowest in-hospital mortality. These findings do not support supratherapeutic repletion of potassium and magnesium.
Abstract 19422: Origin of Ventricular Fibrillation in Bileaflet Mitral Valve Prolapse Syndrome
Syed, Faisal F. , Ackerman, Michael J. , Mulpuru, Siva K. , Sriram, Chenni S. , Cannon, Bryan C. , McLeod, Christopher J. , Kapa, Suraj , Asirvatham, Samuel J. , Noseworthy, Peter A.

Circulation | March 19, 2022 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.19422 Get It

Introduction: Although most patients with mitral valve prolapse (MVP) have a benign prognosis, there is a subgroup with bileaflet MVP syndrome (biMVPS) at increased risk of idiopathic ventricular fibrillation (VF). The phenotypic features of this syndrome include myxomatous bileaflet prolapse, complex ventricular ectopy (VE), T-wave inversion in inferolateral ECG leads, and female predominance. The mechanism of ventricular arrhythmia in these patients is unknown. Methods: We reviewed our center’s ablation experience of 14 consecutive patients with biMVPS patients between February 2007 and October 2013 (n=13 female, median [range] age at index ablation 33.8 [21.0 - 58.7] years, left ventricular ejection fraction [EF] 60 [45-67] %, all ≤ moderate mitral regurgitation [MR]). We compared findings from 6 with prior sudden cardiac arrest (SCA) and recurrent ICD shocks for drug refractory VF with 8 who had symptomatic drug-refractory complex VE but without prior SCA. Results: All patients with prior SCA had a predominant VE trigger for the VF. There was no difference between the two groups in EF, MR severity, VE burden, and number of different VE morphologies or foci ablated. Sites of successful VE ablation at index procedure were the LV papillary muscles (PM, n=6 anterior, 6 posterior), fascicular system (n=5 anterior, 4 posterior), mitral annulus (n=2), outflow tracts (3 RVOT, 1 LVOT), and coronary sinus (n=1). All patients had at least one LV papillary or fascicular VE focus. Purkinje origin VE was identified as the VF trigger in 6/6 SCA patients (3 from PM, 3 from LV fascicles) and only 4/8 (none from PM) non-SCA patients (p=0.04). Acute success was seen in 17/19 procedures with no complications. VF storm occurred within 24 hours of ablation in a single patient. At 310 (39 - 2099) days follow-up, 1 SCA patient received a single shock (p=0.031 compared to pre-ablation), and symptoms from VE were reduced in 12/14. Conclusions: BiMVPS is characterized by VE from the LV fascicles and papillary muscles that trigger VF. The VE is invariably multifocal and may also involve the outflow tracts and mitral annulus. Ablation of clinically dominant VE foci alleviates symptoms and reduces the number of VF-terminating ICD shocks.
Abstract 16562: Cardiac Device Implantation Post TAVR: Mortality and Rates of Pacemaker Dependency
Padmanabhan, Deepak , Eleid, Mackram F. , Deshmukh, Abhishek , Cha, Yong-Mei M, Asirvatham, Samuel, Friedman, Paul A. , Greason, Kevin L. , Gulati, Rajiv , Scott, Christopher G. , McLeod, Christopher J. , Cha, Yong-Mei M, Noseworthy, Peter A.

Circulation | March 19, 2022 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.16562 Get It

Background: Transcatheter aortic valve replacement (TAVR) is often complicated by AV block requiring pacing, but whether patients recover AV conduction and whether the need for pacing affects outcomes is unknown. Methods: We retrospectively studied 534 patients who underwent TAVR at Mayo Clinic in Rochester, Minnesota between November 2008 and January 2015. Of these, 115 patients had implantable cardiac devices. Data was collected from subsequent device follow-ups to determine pacemaker dependency and percentage pacing. Results: 44 patients (8.2%) had devices implanted in the immediate post procedural period. The most common indications for implantation were high grade AV block (18 patients) and complete heart block (14 patients). 17/44 (38.6%) patients were pacemaker-dependent at implant and only 4 of these patients were no longer pacemaker-dependent during subsequent followup. The indication for pacing among these four patients was high grade atrio-ventricular block (2 patients), asystole (1 patient) and complete heart block (1). Among non-pacemaker-dependent patients, no significant change in the ventricular pacing percentages was noted over time. Survival was similar between patients who required device implantation post TAVR and those who did not after adjustment for age and gender (HR 0.73 [0.39-1.36], p=ns; figure) Conclusion: Patients requiring pacing after TAVR are often pacemaker-dependent at the time of implant. It is uncommon for patients who are dependent at the time of implant to regain AV conduction, but the need for cardiac pacing is not associated with increased mortality.
Abstract 16326: Safety and Efficacy of Novel Oral Anticoagulants in Subjects With Atrial Fibrillation in Relation to Renal Function: Meta-analysis of Randomized Clinical Trials
Carpio, Freddy Del, Gharacholou, S. Michael , Branson, Andrea M, Paletta, Dawn M, Brose, Pamela K, Asirvatham, Samuel J.

Circulation | March 19, 2022 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.16326 Get It

Introduction: The efficacy and safety of novel oral anticoagulants (NOACs) has not been assessed in subjects with renal impairment. Methods: We performed a meta-analysis of RCTs comparing NOACs with warfarin in patients with atrial fibrillation (AF), in relation to renal function estimated by glomerular filtration rate (GFR): normal (GFR>80 ml/min/1.73m2), mild (50-80 mL/min/1.73m2), and moderate (<50 mL/min/1.73m2) impairment. MEDLINE, Embase, Web of Science and the Cochrane Library were searched to identify articles published up to the third week of January 2015. Data were supplemented with FDA data. Data on stroke or systemic embolism (S/SE) and major bleeding according to renal function were collected and extracted. We estimated the pooled relative risk (RR) of S/SE and major bleeding, for NOACs compared to warfarin. Results: We retrieved four randomized clinical trials (each randomizing dabigatran, rivaroxaban, apixaban, or endoxaban versus warfarin) enrolling a total of 58338 subjects, 29123 randomized to NOACs and 29123 randomized to warfarin; 21132 had normal renal function, 13126 had mild and 11027 had moderate renal impairment. In subjects with moderate renal impairment, compared to warfarin, NOACs reduced the risk of S/SE (RR 0.8; 95% CI 0.68-0.94) and major bleeding (RR 0.80; 95% CI 0.71-0.91). In subjects with mild renal impairment NOACs were associated with a reduced risk of S/SE (RR 0.75; 95% CI 0.66-0.85) and major bleeding (RR 0.87; 95% CI 0.79-0.95). In subjects with normal renal function no difference in the risk of S/SE was observed, while the risk of major bleeding was slightly less for subjects taking NOACs (RR 0.87; 95% CI 0.76-0.99). The test for interaction among groups of renal function was borderline significant for S/SE, but not for major bleeding. Conclusions: The use of NOACs was associated with a reduced risk of S/SE in subjects with mild or moderate renal impairment; while the risk of bleeding was reduced by NOACs compared to warfarin.
Abstract 16261: Risk of Stroke or Systemic Embolism After Transseptal Ablation in Patients With Implanted Cardiac Devices
Madhavan, Malini , Sangaralingham, Lindsey R. , Noseworthy, Peter A. , DeSimone, Christopher V. , McLeod, Christopher J. , Asirvatham, Samuel J. , Yao, Xiaoxi

Circulation | March 19, 2022 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.16261 Get It

Introduction: Mobile thrombi are commonly observed on endovascular leads at the time of catheter ablation. Transseptal puncture poses a risk of paradoxical embolism. We sought to examine the risk of stroke or systemic embolism after transseptal ablation in patients with and without cardiac implantable electronic devices (CIEDs). Methods: Using a large, national administrative claims database we identified 31,720 patients who underwent a catheter ablation requiring transseptal puncture between 1/1/2004 and 9/30/2014. We created two propensity-matched cohorts, matching on age, gender, race, household income, region, Charlson index, CHADS-Vasc score, and year and indication for ablation (5,533 patients with CIEDs and 11,300 patients without devices). Incidence rates (events/100 patient-years) and propensity score-matched cox proportional hazards models (with 95% confidence intervals) were used to estimate risk of stroke, transient ischemic attack, or systemic embolism for patients with or without CIEDs. We also examined the impact of presence of a CIED and oral anticoagulation (OAC) use on risk of stroke or systemic embolism within the matched cohort. Average follow up was 2.1 years. Results: The event rate was 1.5 per 100 person years in patients without device, and 1.9 per 100 person years in patients with device. Among patients not on OAC, presence of a cardiac device was associated with an increased risk of stroke or systemic embolism (HR 1.71 [1.24-2.35], P<0.01) whereas there was no association among patients treated with OAC (0.98 [0.75_1.28], p=ns) (Figure). Conclusions: Cardiac devices are associated with an increased risk of stroke or systemic embolism after transseptal ablation, but this risk is attenuated with post ablation OAC use. Anticoagulation should be considered for all patients with CIEDs post transseptal ablation, regardless of the presence of another compelling indication for anticoagulation.
A real‐world experience of atrioventricular synchronous pacing with leadless ventricular pacemakers
Kowlgi, Gurukripa N. , Tseng, Andrew S. , Tempel, Nathan D., Henrich, Mark, Venkatachalam, Kalpathi L., Scott, Luis R. , Shen, Win‐Kuang , Deshmukh, Abhishek , Madhavan, Malini , Lee, Hon‐Chi, Asirvatham, Samuel J. , Friedman, Paul A. , Cha, Yong‐Mei , Mulpuru, Siva K. , Henrich, Mark J, Deshmukh, Abhishek J , Tseng, A S , Asirvatham, Samuel J , Kowlgi, Narayan G

Journal of Cardiovascular Electrophysiology | March 2, 2022 | Volume: 33 | Issue: 5 | Pages: 982-993

10.1111/jce.15430 | PMID 35233867 Get It

AbstractAimsThe MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer‐based atrial sensing. Data regarding the real‐world experience with this novel system are scarce. We sought to characterize patients undergoing MicraTM‐AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony.MethodsIn this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM‐AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow‐up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous ventricular pacing (AsVP) ≥ 70%.ResultsSixty‐five percent of patients achieved AsVP ≥ 70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure, and prior cardiac surgery. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were small A4‐wave amplitude, high ventricular pacing burden, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow‐up.ConclusionWith the increasing popularity of leadless pacemakers, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM‐AV devices.
Cardiac ablation with pulsed electric fields: principles and biophysics
Sugrue, Alan , Munoz, Freddy Del‐Carpio , Killu, Ammar M. , Asirvatham, Samuel J. , Del-Carpio Munoz, Freddy , Asirvatham, Samuel J , Maor, Elad

EP Europace | February 25, 2022 | Volume: 24 | Issue: 8 | Pages: 1213-1222

10.1093/europace/euac033 | PMID 35426908 Get It

Abstract Pulsed electric fields (PEFs) have emerged as an ideal cardiac ablation modality. At present numerous clinical trials in humans are exploring PEF as an ablation strategy for both atrial and ventricular arrhythmias, with early data showing significant promise. As this is a relatively new technology there is limited understanding of its principles and biophysics. Importantly, PEF biophysics and principles are starkly different to current energy modalities (radiofrequency and cryoballoon). Given the relatively novel nature of PEFs, this review aims to provide an understanding of the principles and biophysics of PEF ablation. The goal is to enhance academic research and ultimately enable optimization of ablation parameters to maximize procedure success and minimize risk.