Comparison of the Roche LightCycler vanA / vanB Detection Assay and Culture for Detection of Vancomycin-Resistant Enterococci from Perianal Swabs
Sloan, Lynne M., Uhl, J. R., Vetter, Emily A., Schleck, Cathy D. , Harmsen, William S. , Manahan, Janice M., Thompson, Roger, Rosenblatt, Jon E., Cockerill, Franklin R.

Journal of Clinical Microbiology | June 7, 2004 | Volume: 42 | Issue: 6 | Pages: 2636-2643

10.1128/jcm.42.6.2636-2643.2004 Get It

ABSTRACT We compared the performance characteristics of a real-time PCR method, the LightCycler vanA / vanB detection assay (Roche Diagnostics Corporation, Indianapolis, Ind.) to that of Enterococcosel agar (BBL, Sparks, Md.) for direct detection of vancomycin-resistant enterococci (VRE) from 894 perianal stool swabs. For 421 of 894 swabs, the result for LightCycler PCR was compared to an Enterococcosel plate containing vancomycin at 6 μg/ml; for the remaining 473 swabs, the result for LightCycler PCR was compared to an Enterococcosel plate containing 8 μg/ml vancomycin. The LightCycler method produced considerably more positive results than either the Enterococcosel plate containing vancomycin at 6 μg/ml ( n = 25 versus n = 11; sensitivity, 100%; specificity, 97%; positive predictive value [PPV], 42%; negative predictive value [NPV], 100%) or the Enterococcosel plate containing vancomycin at 8 μg/ml ( n = 31 versus n = 10; sensitivity, 100%; specificity, 95%; PPV, 32%; NPV, 100%). When possible, additional testing, including culture, LightCycler PCR, and/or a conventional PCR method (PCR-restriction fragment length polymorphism assay), were performed on either the original specimens or original cultures or subsequent specimens for cases in which the original specimen was positive by LightCycler PCR but the Enterococcosel plate was negative. This additional testing demonstrated positive results for 7 of 14 (50%) evaluable discordant specimens which initially tested as LightCycler PCR positive but culture negative using the Enterococcosel plate containing vancomycin at 6 μg/ml and 12 of 17 (71%) evaluable discordant specimens which initially tested as LightCycler positive but culture negative using the Enterococcosel plate containing vancomycin at (8 μg/ml). These results demonstrate that the LightCycler VRE detection assay is considerably more sensitive than the standard culture method for detecting VRE directly from perianal swab specimens. The LightCycler assay also provides results much faster than culture (∼3.5 versus ≥72 h). The use of this test could have important implications for the effective control and prevention of nosocomial outbreaks of VRE.
Response of the Clinical Microbiology Laboratory to Emerging (New) and Reemerging Infectious Diseases
Cockerill, Franklin R., Smith, Thomas F.

Journal of Clinical Microbiology | June 7, 2004 | Volume: 42 | Issue: 6 | Pages: 2359-2365

10.1128/jcm.42.6.2359-2365.2004 Get It

Evaluation of the MagNA Pure LC Instrument for Extraction of Hepatitis C Virus RNA for the COBAS AMPLICOR Hepatitis C Virus Test, Version 2.0
Germer, Jeffrey J., Lins, Michele M., Jensen, Monica E., Harmsen, William S. , Ilstrup, Duane M., Mitchell, P. Shawn, Cockerill, Franklin R., Patel, Robin , Patel, Robin

Journal of Clinical Microbiology | August 6, 2003 | Volume: 41 | Issue: 8 | Pages: 3503-3508

10.1128/jcm.41.8.3503-3508.2003 Get It

ABSTRACT The COBAS AMPLICOR system has played a major role in the transition of molecular diagnostics from research to routine clinical laboratory use by automating the nucleic acid amplification and detection processes. However, sample preparation remains a labor-intensive portion of the procedure. In this study, we evaluated the performance of the COBAS AMPLICOR Hepatitis C Virus Test, version 2.0 (Roche Molecular Systems, Branchburg, N.J.) following manual hepatitis C virus (HCV) RNA extraction versus automated extraction with the MagNA Pure LC instrument (Roche Applied Science, Indianapolis, Ind.). Parallel replicate testing was performed with standard dilutions of 100, 75, 60, and 0 HCV IU/ml and 153 clinical specimens. An analytical sensitivity of 75 IU/ml was achieved with either the manual or the standard-volume (200 μl) automated extraction methodologies (25 of 26 [96.2%]; 95% confidence interval [95% CI], 80.4 to 99.9), whereas the clinical sensitivity and specificity were both 100% with either extraction method. A large-volume (1 ml) automated extraction method was also evaluated with standard dilutions of 40, 25, 10, and 0 IU/ml and the same 153 clinical specimens. The analytical sensitivity of the COBAS AMPLICOR assay with the large-volume extraction method was 25 HCV IU/ml (26 of 26 [100%]; 95% CI, 86.8 to 100), whereas the clinical sensitivity and specificity were both 100%. The MagNA Pure LC instrument is a versatile, labor-saving platform capable of integration with minimal modification of the existing assay procedure. The increased sensitivity of the COBAS AMPLICOR Hepatitis C Virus Test, version 2.0 performed in conjunction with large-volume HCV RNA extraction may be important in HCV diagnostic testing as new therapeutic strategies evolve.
Comparison of LightCycler PCR, Rapid Antigen Immunoassay, and Culture for Detection of Group A Streptococci from Throat Swabs
Uhl, J. R., Adamson, Steven C., Vetter, Emily A., Schleck, Cathy D. , Harmsen, William S. , Iverson, L. K., Santrach, Paula J., Henry, Nancy K., Cockerill, Franklin R.

Journal of Clinical Microbiology | January 7, 2003 | Volume: 41 | Issue: 1 | Pages: 242-249

10.1128/jcm.41.1.242-249.2003 Get It

ABSTRACT We compared the performance characteristics of a real-time PCR method, the LightCycler Strep-A assay (Roche Applied Science, Indianapolis, Ind.), to those of a rapid antigen immunoassay, the Directigen 1-2-3 Group A Strep Test kit (BD Diagnostic Systems, Sparks, Md.), and a standard culture method for detection of group A streptococci (GAS) from 384 throat swabs. The LightCycler PCR produced more positive results ( n = 58) than either culture ( n = 55) or the Directigen immunoassay ( n = 31). The results of the LightCycler PCR and the Directigen method were independently compared to the results of the accepted “gold standard,” bacterial culture. The sensitivities, specificities, and positive and negative predictive values for this comparison were as follows: for the Directigen method, 55, 99, 97, and 93%, respectively; for the LightCycler PCR, 93, 98, 88, and 99%, respectively. In no case was a throat swab positive by both the LightCycler PCR and the Directigen method but negative by culture. The medical histories of patients whose throat swabs were negative by culture but positive by either the LightCycler PCR ( n = 7) or the Directigen method ( n = 1) were reviewed. All of these patients had signs or symptoms compatible with GAS disease, and therefore, all of these discordant positive results (along with positive results by either the Directigen method or the LightCycler PCR that agreed with the culture results) were counted as true positives for statistical analysis. For this analysis, the LightCycler PCR detected more true-positive results than the culture method (58 versus 55 swabs); however, this difference was not statistically significant ( P = 0.5465). In contrast, statistically significantly more true-positive results occurred by culture than by the Directigen method (55 versus 31 swabs; P < 0.0001) and by the LightCycler PCR than by the Directigen method (58 versus 31 swabs; P < 0.0001). The LightCycler PCR is a suitable stand-alone method for the detection of GAS from throat swabs. Additionally, this method requires less than half the personnel time and the procedure can be completed in considerably less time (∼1 h) than our standard approach (up to 2 days) for detection of GAS in throat swabs (i.e., testing by the Directigen method with negative results verified by culture).
Comparison of the Borrelia DotBlot G, MarDx, and VIDAS Enzyme Immunoassays for Detecting Immunoglobulin G Antibodies to Borrelia burgdorferi in Human Serum
Jespersen, Deborah J., Smith, Thomas F., Rosenblatt, Jon E., Cockerill, Franklin R.

Journal of Clinical Microbiology | November 26, 2002 | Volume: 40 | Issue: 12 | Pages: 4782-4784

10.1128/jcm.40.12.4782-4784.2002 Get It

ABSTRACT Three enzyme immunoassays, Borrelia DotBlot G (GenBio, San Diego, Calif.), MarDx EIA (MarDx Diagnostics, Inc., Carlsbad, Calif.), and VIDAS (bioMérieux, St. Louis, Mo.) were compared for their ability to detect immunoglobulin G antibodies to Borrelia burgdorferi in 100 human serum samples. The “gold standard” positive result for each of these samples was determined by Western immunoblot analysis (MarDx Marblot Test System) ( n = 99) or clinical signs and symptoms suggestive of Lyme disease with other laboratory results positive for B. burgdorferi ( n = 1). Based on these criteria for a gold standard positive result, 29 of the 100 samples tested were considered true positives and 71 were considered true negatives. The following sensitivities and specificities were noted, respectively, for each method: Borrelia DotBlot G, 93 and 90%; MarDx, 100 and 35%; and VIDAS, 100 and 92%. Because of high sensitivity and specificity and ease of use, the VIDAS test is an appealing method, especially for laboratories that perform high volumes of tests. The high sensitivity but low specificity of the MarDx method compared to the VIDAS and Borrelia DotBlot G methods requires that Western blot confirmatory tests be performed frequently. The Borrelia DotBlot G method has acceptable specificity but appears to lack sensitivity when compared to the VIDAS and MarDx methods.
Detection of Bacillus anthracis DNA by LightCycler PCR
Bell, Constance A., Uhl, James R., Hadfield, Ted L., Meyer, Richard F. , Smith, Thomas F., Cockerill, Franklin R., David, J. C.

Journal of Clinical Microbiology | October 1, 2002 | Volume: 40 | Issue: 8 | Pages: 2897-2902

10.1128/jcm.40.8.2897-2902.2002 Get It

ABSTRACT Anthrax is a zoonotic disease that is also well recognized as a potential agent of bioterrorism. Routine culture and biochemical testing methods are useful for the identification of Bacillus anthracis , but a definitive identification may take 24 to 48 h or longer and may require that specimens be referred to another laboratory. Virulent isolates of B. anthracis contain two plasmids (pX01 and pX02) with unique targets that allow the rapid and specific identification of B. anthracis by PCR. We developed a rapid-cycle real-time PCR detection assay for B. anthracis that utilizes the LightCycler instrument (LightCycler Bacillus anthracis kit; Roche Applied Science, Indianapolis, Ind.). PCR primers and probes were designed to identify gene sequences specific for both the protective antigen (plasmid pX01) and the encapsulation B protein (plasmid pX02). The assays (amplification and probe confirmation) can be completed in less than 1 h. The gene encoding the protective antigen ( pagA ) was detected in 29 of 29 virulent B. anthracis strains, and the gene encoding the capsular protein B ( capB ) was detected in 28 of 29 of the same strains. Three avirulent strains containing only pX01 or pX02, and therefore only pagA or pagB genes, could be detected and differentiated from virulent strains. The assays were specific for B. anthracis : the results were negative for 57 bacterial strains representing a broad range of organisms, including Bacillus species other than anthracis ( n = 31) and other non- Bacillus species ( n = 26). The analytical sensitivity demonstrated with target DNA cloned into control plasmids was 1 copy per μl of sample. The LightCycler Bacillus anthracis assay appears to be a suitable method for rapid identification of cultured isolates of B. anthracis . Additional clinical studies are required to determine the usefulness of this test for the rapid identification of B. anthracis directly from human specimens.
Oxidative Stress Increases Susceptibility of Mycobacterium tuberculosis to Isoniazid
Bulatović, Vanja M., Wengenack, Nancy L. , Uhl, James R., Hall, Leslie, Roberts, Glenn D., Cockerill, Franklin R., Rusnak, Frank

Antimicrobial Agents and Chemotherapy | October 1, 2002 | Volume: 46 | Issue: 9 | Pages: 2765-2771

10.1128/aac.46.9.2765-2771.2002 Get It

ABSTRACT Isoniazid is a first-line antibiotic used in the treatment of infections caused by Mycobacterium tuberculosis . Isoniazid is a prodrug requiring oxidative activation by the catalase-peroxidase hemoprotein, KatG. Resistance to isoniazid can be obtained by point mutations in the katG gene, with one of the most common being a threonine-for-serine substitution at position 315 (S315T). The S315T mutation is found in more than 50% of isoniazid-resistant clinical isolates and results in an ≈200-fold increase in the MIC of isoniazid compared to that for M. tuberculosis H37Rv. In the present study we investigated the hypothesis that superoxide plays a role in KatG-mediated isoniazid activation. Plumbagin and clofazimine, compounds capable of generating superoxide anion, resulted in a lower MIC of isoniazid for M. tuberculosis H37Rv and a strain carrying the S315T mutation. These agents did not cause as great of an increase in isoniazid susceptibility in the mutant strain when the susceptibilities were assessed by using the inhibitory concentration that causes a 50% decrease in growth. These results provide evidence that superoxide can play a role in isoniazid activation. Since clofazimine alone has antitubercular activity, the observation of synergism between clofazimine and isoniazid raises the interesting possibility of using both drugs in combination to treat M. tuberculosis infections.
Detection of Smallpox Virus DNA by LightCycler PCR
Espy, Mark J., Cockerill, Franklin R., Meyer, Richard F. , Bowen, Michael D. , Hadfield, Ted L., Smith, Thomas F., Poland, Gregory A.

Journal of Clinical Microbiology | July 27, 2002 | Volume: 40 | Issue: 6 | Pages: 1985-1988

10.1128/jcm.40.6.1985-1988.2002 Get It

ABSTRACT A 300-bp plasmid fragment of the hemagglutinin gene was used as target DNA to develop a rapid real-time LightCycler (Roche Applied Science, Indianapolis, Ind.) PCR assay for laboratory detection of smallpox virus. PCR primers and probes were designed specifically for detection of smallpox virus DNA, but all viruses of the genus Orthopoxvirus tested could be detected by use of the hemagglutinin gene target sequence. Base pair mismatches in the 204-bp amplicon allowed discrimination of cowpox virus (melting temperature [ T m ], 56.40°C), monkeypox virus ( T m , 56.24°C), and vaccinia virus ( T m , 56.72°C), including the Dryvax vaccine strain, from smallpox virus ( T m , 62.45°C) by melting curve analysis. The analytical sensitivity was 5 to 10 copies of target DNA per sample. The assay was specific for members of the genus Orthopoxvirus ; the DNAs of herpes simplex virus and varicella-zoster virus were not detected by the smallpox virus LightCycler PCR.
The Biopesticide Paenibacillus popilliae Has a Vancomycin Resistance Gene Cluster Homologous to the Enterococcal VanA Vancomycin Resistance Gene Cluster
Patel, Robin , Piper, Kerryl E., Cockerill, Franklin R., Steckelberg, James M., Yousten, Allan A., Patel, Robin

Antimicrobial Agents and Chemotherapy | July 27, 2002 | Volume: 44 | Issue: 3 | Pages: 705-709

10.1128/aac.44.3.705-709.2000 Get It

ABSTRACT We have previously identified, in Paenibacillus popilliae , a 708-bp sequence which has homology to the sequence of the enterococcal vanA gene. We have performed further studies revealing five genes encoding homologues of VanY, VanZ, VanH, VanA, and VanX in P. popilliae . The predicted amino acid sequences are similar to those in VanA vancomycin-resistant enterococci: 61% identity for VanY, 21% for VanZ, 74% for VanH, 77% for VanA, and 79% for VanX. The genes in P. popilliae may have been a precursor to or have had ancestral genes in common with vancomycin resistance genes in enterococci. The use of P. popilliae biopesticidal preparations in agricultural practice may have an impact on bacterial resistance in human pathogens.
Direct Detection of Legionella Species from Bronchoalveolar Lavage and Open Lung Biopsy Specimens: Comparison of LightCycler PCR, In Situ Hybridization, Direct Fluorescence Antigen Detection, and Culture
Hayden, Randall T. , Uhl, J. R., Qian, Xiang , Hopkins, Marlene K., Aubry, MC , Lloyd, Ricardo V., Cockerill, F. R., Limper, Andrew H. , Cockerill, Franklin R., Hayden, Randall T

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 7 | Pages: 2618-2626

10.1128/jcm.39.7.2618-2626.2001 Get It

ABSTRACT We developed a rapid thermocycling, real-time detection (also known as real-time PCR) method for the detection of Legionella species directly from clinical specimens. This method uses the LightCycler (Roche Molecular Biochemicals, Indianapolis, Ind.) and requires approximately 1 to 2 h to perform. Both a Legionella genus PCR assay and Legionella pneumophila species-specific PCR assay were designed. A total of 43 archived specimens from 35 patients were evaluated, including 19 bronchoalveolar lavage (BAL) specimens and 24 formalin-fixed, paraffin-embedded open lung biopsy specimens. Twenty-five of the specimens were culture-positive for Legionella (9 BAL specimens and 16 tissue specimens). BAL specimens were tested by LightCycler PCR (LC-PCR) methods and by a direct fluorescent antibody (DFA) assay, which detects L. pneumophila serogroups 1 to 6 and several other Legionella species. Tissue sections were tested by the two LC-PCR methods, by DFA, by an in situ hybridization (ISH) assay, specifically designed to detect L. pneumophila , and by Warthin-Starry (WS) staining. The results were compared to the “gold standard” method of bacterial culture. With BAL specimens the following assays yielded the indicated sensitivities and specificities, respectively: Legionella genus detection by Legionella genus LC-PCR, 100 and 100%; Legionella genus detection by DFA assay, 33 and 100%; and L. pneumophila detection by L. pneumophila species-specific LC-PCR, 100 and 100%. With open lung biopsy specimens the following assays yielded the indicated sensitivities and specificities, respectively: Legionella genus detection by LC-PCR 68.8 and 100%; Legionella genus detection by DFA assay, 44 and 100%; Legionella genus detection by WS staining, 63 and 100%; L. pneumophila species-specific detection by LC-PCR, 17 and 100%; and L. pneumophila species-specific detection by ISH, 100 and 100%. The analytical sensitivity of both LC-PCR assays was <10 CFU/reaction. LC-PCR is a reliable method for the direct detection of Legionella species from BAL specimens. The Legionella genus LC-PCR assay could be performed initially; if positive, L. pneumophila species-specific LC-PCR could then be performed (if species differentiation is desired). The speed with which the LC-PCR procedure can be performed offers significant advantages over both culture-based methods and conventional PCR techniques. In contrast, for the methods evaluated, culture was the best for detecting multiple Legionella species in lung tissue. WS staining, Legionella genus LC-PCR, and L. pneumophila species-specific ISH were useful as rapid tests with lung tissue.