Evaluation of a Routine Anaerobic Subculture of Blood Cultures for Detection of Anaerobic Bacteremia
Paisley, John, Rosenblatt, Jon E., Hall, M M, Washington, John A., Paisley, John W.

Journal of Clinical Microbiology | June 2, 2021 | Volume: 8 | Issue: 6 | Pages: 764-766

10.1128/jcm.8.6.764-766.1978 Get It

The value of a routine 48-h anaerobic subculture of blood cultures was assessed in our laboratory over a 4-month period. Excluding presumed contaminants, anaerobes represented 51 (6.9%) of the total number of 734 positive cultures. Sixteen isolates (all Bacteroides ) from six patients were detected by the anaerobic subculture. All but one of these were also detected macroscopically. Excluding the one isolate, the routine anaerobic subculture hastened the identification of anaerobic organisms by only 1 day in two patients. We conclude that a routine anaerobic subculture is not indicated for the detection of anaerobic bacteremia.
Clinical comparison of difco ESP, Wampole isolator, and Becton Dickinson Septi-Chek aerobic blood culturing systems
Cockerill, Franklin R., Torgerson, C A, Reed, G S, Vetter, Emily A., Weaver, Amy L. , Dale, J C, Roberts, Glenn D., Henry, Nancy K., Ilstrup, D M, Rosenblatt, Jon E.

Journal of Clinical Microbiology | January 6, 2020 | Volume: 34 | Issue: 1 | Pages: 20-24

10.1128/jcm.34.1.20-24.1996 Get It

The ESP 80A aerobic blood culture of the ESP automated blood culture system (Difco Laboratories. Detroit, Mich.) was compared with two manual aerobic blood culture systems, the Isolator (Wampole Laboratories, Cranbury, N.J.) and the Septi-Chek (Becton Dickinson, Cockeysville, Md.) systems, for the detection of bloodstream microorganisms from 5,845 blood samples for culture collected from adult patients with suspected septicemia. The bottles were incubated for 7 days, and the sediment from the Isolator tube was inoculated onto solid medium and this medium was incubated for 72 h. A total of 609 microorganisms were recovered from 546 blood cultures. There was no statistically significant difference in the total recovery of microorganisms for the ESP 80A system when compared with that for the Septi-Chek system (P = 0.083); however, the Isolator system recovered significantly more microorganisms overall than either the ESP 80A (P < 0.001) or the Septi-Chek (P < 0.001) system. When assessing individual probable pathogens, the Isolator system detected statistically significantly more Staphylococcus aureus and Candida spp. than either the ESP 80A or the Septi-Chek system (P < 0.05). Similarly, the Isolator system detected statistically significantly more bloodstream infections (septic episodes) caused by S. aureus and Candida spp. than either the ESP 80A or the Septi-Chek system (P < 0.05). In blood culture sets which produced growth of the same probable pathogens in the ESP 80A and the Isolator systems, there was no statistically significant difference in the median times to detection for all pathogens combined (P = 0.067). However, a similar comparison showed the Isolator and the ESP 80A systems to have statistically significantly shorter median detection times for all pathogens combined (P < 0.001) when they were independently compared with the Septi-Chek system. The ESP 80A system had 29 (0.5%) false-positive signals. The ESP system required less processing time than the Isolator system and eliminates the hands-on time for the detection of positive cultures required by the manual systems.
Evaluation of enzyme-linked immunoassay for serological diagnosis of cysticercosis
Sloan, Lynne M., Schneider, Susan K., Rosenblatt, Jon E.

Journal of Clinical Microbiology | January 6, 2020 | Volume: 33 | Issue: 12 | Pages: 3124-3128

10.1128/jcm.33.12.3124-3128.1995 Get It

We evaluated a commercially available enzyme-linked immunoassay (ELISA) from LMD Laboratories, Inc., Carlsbad, Calif., for the detection of antibodies in serum to the cysticercus of Taenia solium. The ELISA was performed on 308 serum samples; 198 from a pool of healthy individuals, 42 from patients who had antibodies against a variety of parasites other than T. solium, and 68 from patients suspected of having cysticercosis. All of these 68 specimens were tested both by the ELISA and by an immunoblot method (enzyme-linked immunoelectrotransfer blot assay [EITB]) developed at the Parasitic Serology Laboratory of the Centers for Disease Control and Prevention. Twenty-seven of the 68 serum samples from patients suspected of having cysticercosis were positive by both EITB and ELISA, while 31 were negative by both assays. ELISA results for three and two samples were considered false positive and false negative, respectively, when compared with the results of EITB. Results for an additional five samples were considered equivocal but were technically positive because their optical density readings were slightly above the cutoff value. Three of the 198 serum samples from the bank of serum samples from healthy individuals were also false positive by ELISA (the EITB result for the samples was negative). Six other serum samples from healthy individuals which had equivocal results and the five serum samples from patients with equivocal results were EITB negative. Serum samples containing antibodies against Echinococcus spp. frequently cross-reacted with the cysticercus ELISA antigen (13 of 16 specimens), but serum samples with antibodies against other parasites did not (2 of 26 specimens); all of these serum samples were EITB negative. The commercially available ELISA that we describe is a simple and rapid test. Considering all 308 specimens, the ELISA had a specificity of 93% (when samples with equivocal results were considered negative) or 89% (when samples with equivocal results were considered positive); the sensitivity was 93%.
Comparison of agar dilution, broth dilution, and disk diffusion testing of ampicillin against Haemophilus species by using in-house and commercially prepared media
Kohner, Peggy C., Rosenblatt, Jon E., Cockerill, Franklin R.

Journal of Clinical Microbiology | January 6, 2020 | Volume: 32 | Issue: 6 | Pages: 1594-1596

10.1128/jcm.32.6.1594-1596.1994 Get It

An evaluation to determine the optimal method for the in vitro susceptibility testing of Haemophilus strains to ampicillin was undertaken. In our hands, in-house-prepared Haemophilus Test Medium used by either the broth macrodilution or agar dilution method produced the most consistent results, especially for beta-lactamase-negative, ampicillin-resistant H. influenzae strains.
Evaluation of an enzyme-linked immunosorbent assay for detection of Cryptosporidium spp. in stool specimens
Rosenblatt, Jon E., Sloan, Lynne M.

Journal of Clinical Microbiology | January 5, 2020 | Volume: 31 | Issue: 6 | Pages: 1468-1471

10.1128/jcm.31.6.1468-1471.1993 Get It

We evaluated a commercially produced enzyme-linked immunosorbent assay (ELISA; LMD Laboratories, Inc.) for the detection of Cryptosporidium spp. in 296 stool specimens submitted to the Mayo Clinic parasitology laboratory for routine examination. The specimens examined were fresh (4 specimens), were stored frozen at -65 degrees C (49 specimens), or were preserved in 10% formalin (243 specimens). Results were compared with those obtained by indirect immunofluorescent antibody detection (Merifluor Cryptosporidium/Giardia; Meridian Diagnostics, Inc.). One hundred of the specimens were positive by indirect immunofluorescent antibody and ELISA, while 187 were negative by both methods; 91 of these negative stool samples contained 121 parasites of 17 different species. Eight ELISA false negatives and one false positive were observed. The ELISA sensitivity was 93%, specificity was 99%, and the positive predictive value was 99%. Storage of specimens preserved in 10% formalin or frozen fresh at -65 degrees C for up to 18 months did not appear to affect the results. There was no cross-reactivity with Giardia lamblia (54 negative specimens) or with the 16 other parasites present in the ELISA-negative stool samples. The ELISA is a fast, easy-to-read, and accurate method for the detection of Cryptosporidium spp. in stool specimens.
Bilophila wadsworthia bacteremia in two patients with hepatic abscesses
Kasten, Mary J. , Rosenblatt, Jon E., Gustafson, Daniel R.

Journal of Clinical Microbiology | January 5, 2020 | Volume: 30 | Issue: 9 | Pages: 2502-2503

10.1128/jcm.30.9.2502-2503.1992 Get It

Bilophila wadsworthia, a recently described anaerobic gram-negative bacillus, was isolated from blood cultures of two patients with liver abscesses. These isolates exhibited the expected phenotypic characteristics, and identification was confirmed by cell wall fatty acid analysis by gas-liquid chromatography. This is the first documentation of bacteremia due to B. wadsworthia.
Clinical Comparison of the Treponema pallidum CAPTIA Syphilis-G Enzyme Immunoassay with the Fluorescent Treponemal Antibody Absorption Immunoglobulin G Assay for Syphilis Testing
Halling, Valerie W., Jones, Mary F. , Bestrom, Jean E., Wold, Arlo D., Rosenblatt, Jon E., Smith, Thomas F., Cockerill, F. R., Cockerill, Franklin R.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 37 | Issue: 10 | Pages: 3233-3234

10.1128/jcm.37.10.3233-3234.1999 Get It

ABSTRACT Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTIA-positive samples (antibody indices of ≥0.650 and ≤0.900) were retested; if the second analysis produced an index of >0.900, the sample was considered positive. Thirteen of 89 (15%) samples had discrepant results. Compared to the FTA-ABS assay, the CAPTIA EIA had a sensitivity and specificity and positive and negative predictive values of 70.7, 97.9, 96.7, and 79.7%, respectively. In another analysis, discrepancies between results were resolved by repeated FTA-ABS testing (technologists were blinded to previous RPR results) and patient chart reviews. Seven CAPTIA-negative samples which were previously interpreted (unblinded) as minimally reactive by the FTA method were subsequently interpreted (blinded) as nonreactive. One other discrepant sample (CAPTIA negative and FTA-ABS positive [at an intensity of 3+], unblinded) was FTA negative with repeated testing (blinded). For the five remaining discrepant samples, chart reviews indicated that one patient (CAPTIA negative and FTA-ABS positive [minimally reactive], blinded) had possible syphilis. These five samples were also evaluated and found to be negative by another treponema-specific test, the Treponema pallidum microhemagglutination assay. Therefore, after repeated testing and chart reviews, 2 of the 89 (2%) samples had discrepant results; the adjusted sensitivity, specificity, and positive and negative predictive values were 96.7, 98.3, 96.7, and 98.3%, respectively. This study demonstrates that the CAPTIA IgG EIA is a reliable method for syphilis testing and that personnel performing tests which require subjective interpretation, like the FTA-ABS test, may be biased by RPR test results.
Detection of Plasmodium knowlesi by Real-Time Polymerase Chain Reaction
Sloan, Lynne M., Rosenblatt, Jon E., Pritt, Bobbi S. , Pritt, Bobbi S , Babady, N. Esther

The American Journal of Tropical Medicine and Hygiene | September 1, 2018 | Volume: 81 | Issue: 3 | Pages: 516-518

10.4269/ajtmh.2009.81.516 Get It

We previously developed a real-time polymerase chain reaction (PCR) assay for detection of the four Plasmodium species that infect humans. Recent studies have shown that natural transmission of the simian parasite Plasmodium knowlesi to humans occurs frequently in Southeast Asia. We have expanded our PCR assay to include detection of P. knowlesi.
Imaging New Paths for Malarial Parasites
Carmichael, Stephen W., Rosenblatt, Jon E.

Microscopy Today | March 14, 2018 | Volume: 14 | Issue: 4 | Pages: 3-5

10.1017/s1551929500050215 Get It

Abstract In general terms, parasites that cause malaria are injected into the skin by mosquitoes. They then travel into the bloodstream and then to the liver where they invade liver cells and mature into forms called schizonts. Within each schizont, cell division produces thousands of tiny new forms called merozoites, each of which, when released into the bloodstream, is capable of infecting a red blood cell. This “traditional” pathway for malarial parasites may not be the only way these parasites travel through the body. Using some increasingly more powerful immuno-imaging tools, Rogerio Amino, Sabine Thiberge, Béatrice Martin, Susanna Celli, Spencer Shorte, Friedrich Frischknecht, and Robert Ménard have demonstrated an additional route that could have profound implications for developing effective vaccines for this major worldwide disease.
Epitome: Maximizing the Productive Interface Between the Clinical Microbiologist and the Infectious Disease Clinician
Rosenblatt, Jon E.

American Journal of Clinical Pathology | February 24, 2016 | Volume: 90 | Issue: 3 | Pages: 355-357

10.1093/ajcp/90.3.355 Get It