Abstract Background To evaluate the long-term clinical performance, the impact of procedural configurations and post-procedure medications in atrial fibrillation patients with percutaneous left atrial appendage occlusion (LAAO). Methods The RECORD study was a prospective, all-comers registry conducted in 39 Chinese centers that consecutively enrolling patients who received LAAO between 1st April 2019 and 31st October 2020 with minimum inclusion and exclusion criteria. Events including any death, any stroke, systemic embolism and bleeding event were collected at 1 year and adjudicated by an independent clinical event committee. Cox proportional hazard models with multivariable adjustments were applied to estimate hazard ratios (HRs) for each outcome. Results Of the 3,096 participants, 3,082 successfully received an LAAO implant and 3,013 (97.8%) completed the 1-year follow-up. Participants had a high risk of stroke (mean CHA2DS2-VASc score of 4.0) and a moderate-to-high risk of bleeding (mean HAS-BLED score of 2.4). Local anesthetic was performed in 1,287 (41.6%) patients and fluoroscopy guidance in 492 (16.0%) patients. In 1295 (42.0%) cases, one-stage combination procedures of LAAO and radiofrequency ablation or cryoablation (CA) were performed. At 1 year, the composite ischemic endpoint of death, stroke, and systemic embolism occurred in 133 (4.51%) patients. Any life-threatening, disabling or major bleeding events occurred in 71 (2.36%) patients. There was no significant association between the type of anesthesia (general versus local), modality of image guidance (TEE, ICE, or fluoroscopy) with the ischemic or bleeding events. Combination procedures of LAAO plus CA was associated with a significantly lower rate of death, stroke, or systemic embolism than performing LAAO only (3.5% versus 5.2%, HRadjusted:0.69, 95%CI:0.48-0.98, P=0.041). The commonest antithrombotic strategy was OAC | APT | APT (38.1%; corresponded to medication prescribed at discharge | 45 days | 6 months), followed by OAC | OAC | APT (27.0%). Compared with OAC | APT | APT, the OAC | OAC | APT group was associated with a higher risk of life-threatening, disabling or major bleeding (1.2% versus 2.5%, HRadjusted:0.50, 95%CI: 0.25-0.99, P=0.47); whereas the risk of death, stroke and SE was numerically similar (2.9% versus 3.0%, HRadjusted:1.05, 95%CI: 0.61-1.78, P=0.867). There was no significant difference between OAC | APT | APT and OAC+APT | APT | APT groups regarding ischemic events; however, in patients with HAS-BLED ≥ 3, OAC | APT | APT was associated with lower rates of life-threatening, disabling or major bleeding events (1.1% versus 4.8%, HRadjusted:4.55, 95%CI: 1.31-15.81, P=0.017). Conclusion In Chinese centers, patients with a WATCHMAN LAAO device had low rates of ischemic and bleeding events at 1 year. One-stage combination procedures of LAAO and catheter ablation was associated with a significantly lower rate of ischemic events than performing LAAO only.Procedural configurations to outcomesPost-LAAO antithrombotic medications
Gamma-Glutamyl Transferase as a prognostic risk factor in complex coronary disease: a serendipitous (re)discovery of machine learning in the SYNTAXES?
Abstract Background/Introduction Over the last decade, epidemiology and pathology studies have suggested that gamma-glutamyl transferase (GGT) has an independent role in the pathogenesis and clinical evolution of cardiovascular diseases associated with atherosclerosis. Recently, machine learning (ML) algorithms have identified pre-procedural GGT as a significant predictor of long-term mortality after coronary revascularization in the SYNTAX trial. Purpose The aim of this study is to investigate the impact of pre-procedural GGT on 10-year all-cause mortality in patients with three-vessel disease (3VD) and/or left main coronary artery disease (LMCAD) following revascularization. Methods The SYNTAX trial was a randomized trial comparing percutaneous coronary intervention (PCI) with coronary artery bypass grafting (CABG) in 1,800 patients with complex CAD. The present report is a post-hoc sub-analysis of the SYNTAXES study, an investigator-driven extended 10-year follow-up of the SYNTAX trial. Before revascularization, blood samples were taken for GGT as well as other biological markers and analyzed by an independent central chemistry laboratory. The primary endpoint was all-cause mortality at 10-years. The changes in hazard for all-cause mortality in GGT over time were modelled using restricted cubic spline functions in a Cox regression model adjusted by age and sex. Subsequently, we compared survival in four groups defined by gender specific GGT thresholds of <32 IU and ≥32 IU for females and <64 IU and ≥64 IU for males, in accordance with prior studies. Results Out of 1,800 patients enrolled in the SYNTAX study, 167 (9.3%) did not have a GGT available at baseline and 1,633 (90.7%) patients were included in the present study. The mean values of GGT for males and females were 43.5±48.5 and 36.4±46.1 U/L, respectively. In the overall population a 10 U/L increase in GGT was significantly associated with 10-year all-cause death (adjusted hazard ratio [HR] 95% confidence interval [CI]: 1.03 [1.02–1.04], p <0.001, Figure A). For Kaplan–Meier analysis, patients were stratified into four groups according to previously reported sex related GGT thresholds. Ten-year mortality was numerically higher in males (adjusted HR 1.31, 95% CI: 0.90–1.91), and significantly higher in females (adjusted HR 1.88, 95% CI: 1.16–3.05) among patients with higher versus lower GGT (Figure B). Furthermore, GGT was significantly associated with CRP, a surrogate-marker of inflammation, as well as established cardiovascular risk biomarkers such as TG, total cholesterol, and glucose. Conclusions Preprocedural GGT is an independent predictor of 10-year mortality following coronary revascularization in patients with 3VD and/or LMCAD. This long-term association has been identified using ML algorithms and should be corroborated using data from large biobanks.Figure AFigure B
Verification and Validation of Lower Body Negative Pressure as a Non-Invasive Bioengineering Tool for Testing Technologies for Monitoring Human Hemorrhage
Since hemorrhage is a leading cause of preventable death in both civilian and military settings, the development of advanced decision support monitoring capabilities is necessary to promote improved clinical outcomes. The emergence of lower body negative pressure (LBNP) has provided a bioengineering technology for inducing progressive reductions in central blood volume shown to be accurate as a model for the study of the early compensatory stages of hemorrhage. In this context, the specific aim of this study was to provide for the first time a systematic technical evaluation to meet a commonly accepted engineering standard based on the FDA-recognized Standard for Assessing Credibility of Modeling through Verification and Validation (V&V) for Medical Devices (ASME standard V&V 40) specifically highlighting LBNP as a valuable resource for the safe study of hemorrhage physiology in humans. As an experimental tool, evidence is presented that LBNP is credible, repeatable, and validated as an analog for the study of human hemorrhage physiology compared to actual blood loss. The LBNP tool can promote the testing and development of advanced monitoring algorithms and evaluating wearable sensors with the goal of improving clinical outcomes during use in emergency medical settings.
Cost-effectiveness of left atrial appendage closure with Watchman for non-valvular atrial fibrillation patients in Japan
Background Transcatheter closure of patent foramen ovale (PFO) has reduced the risk of recurrent stroke in patients with cryptogenic strokes in randomized clinical trials. Whether PFO closure in clinical practice is associated with similar benefit remains unknown. Methods and Results We identified patients with PFO and a history of ischemic stroke or transient ischemic attack who were treated with PFO closure or medical therapy in the OptumLabs database. The primary end point was recurrent ischemic stroke or systemic embolization. Secondary outcomes included mortality, all stroke, transient ischemic attack, and major bleeding. A total of 6668 propensity‐matched patients were included (PFO closure n=4111; medical therapy n=2557). The incidence of stroke or systemic embolization per 100 person‐years was 2.38 after PFO cohort and 2.99 with medical therapy (hazard ratio [HR], 0.85 [95% CI, 0.68–1.05], P =0.13). Mortality was lower in the PFO closure cohort (1.78 versus 2.59 per 100 person‐years: HR, 0.69 [95% CI, 0.55–0.87], P =0.002). Falsification end points showed that this difference is unlikely to be completely explained by residual confounders. There were no significant differences between the groups in secondary end points including intracranial hemorrhage and major bleeding except for an increase in nonintracranial hemorrhage bleeding among patients treated with oral anticoagulation (1.42 versus 2.16 per 100 person‐years: HR, 0.69 [95% CI, 0.48–0.99], P =0.043). The main end point was consistent in subanalyses including patients <60 years of age, patients with prior stroke, and those treated after the publication of the positive PFO trials in 2017. Conclusions In contemporary US practice, PFO closure is not associated with lower rates of recurrent ischemic stroke or systemic embolization compared with medical therapy. Potential reasons for this discrepancy warrant further investigation.
Abstract 14439: Using Augmented Mean Arterial Pressure to Assess Post-Transcatheter Aortic Valve Replacement Mortality
Introduction: Post-transcatheter aortic valve replacement (TAVR) outcome of patients is an important research topic. To accurately assess post-TAVR mortality, we examined a family of new echo-parameters (augmented systolic blood pressure (AugSBP) and arterial mean pressure parameters (AugMAP)) derived from blood pressure and aortic valve gradient ( Figure 1 ). Methods: Patients in the Mayo Clinic National Cardiovascular Diseases Registry-TAVR database who underwent TAVR between January 1, 2012, and June 30, 2017, were identified to retrieve baseline clinical, echocardiographic, and mortality data. The median of AugSBP and AugMAP were used to stratify patients in Kaplan-Meier analysis. Results: The final cohort contained 974 patients with a mean age of 81.4±8.3 years old, and 56.6% were male. The mean Society of Thoracic Surgeons risk score was 8.2±5.2. The median follow-up duration was 354 days, and the one-year all-cause mortality rate was 14.2%. Detailed characteristics are summarized in Table 1. AugMAP1 < 102.5 mmHg (median) was associated with a 3-fold risk of all-cause mortality post-TAVR at 1 year (hazard ratio 3.0, 95%confidence interval 2.0-4.5, p<0.0001)( Figure 1 ). Conclusions: Augmented mean arterial pressure provides clinicians with a simple but effective approach to quickly identify patients at risk and potentially improve post-TAVR prognosis.
The impact of moderate aortic stenosis in acute myocardial infarction: A multicenter retrospective study
AbstractBackgroundAortic stenosis (AS) is associated with myocardial ischemia through different mechanisms and may impair coronary arterial flow. However, data on the impact of moderate AS in patients with acute myocardial infarction (MI) is limited.AimsThis study aimed to investigate the impact of moderate AS in patients presenting with acute myocardial infarction (MI).MethodsWe conducted a retrospective analysis of all patients who presented with acute MI to all Mayo Clinic hospitals, using the Enterprise Mayo PCI Database from 2005 to 2016. Patients were stratified into two groups: moderate AS and mild/no AS. The primary outcome was all cause mortality.ResultsThe moderate AS group included 183 (13.3%) patients, and the mild/no AS group included 1190 (86.7%) patients. During hospitalization, there was no difference between both groups in mortality. Patients with moderate AS had higher in‐hospital congestive heart failure (CHF) (8.2% vs. 4.4%, p = 0.025) compared with mild/no AS patients. At 1‐year follow‐up, patients with moderate AS had higher mortality (23.9% vs. 8.1%, p < 0.001) and higher CHF hospitalization (8.3% vs. 3.7%, p = 0.028). In multivariate analysis, moderate AS was associated with higher mortality at 1‐year (odds ratio 2.4, 95% confidence interval [1.4–4.1], p = 0.002). In subgroup analyses, moderate AS increased all‐cause mortality in STEMI and NSTEMI patients.ConclusionThe presence of moderate AS in acute MI patients was associated with worse clinical outcomes during hospitalization and at 1‐year follow‐up. These unfavorable outcomes highlight the need for a close follow‐up of these patients and for timely therapeutic strategies to best manage these coexisting conditions.
Transcatheter Aortic Valve Replacement Prognostication with Augmented Mean Arterial Pressure
Background: Post-transcatheter aortic valve replacement (TAVR) patient outcome is an important research topic. To accurately assess post-TAVR mortality, we examined a family of new echo parameters (augmented systolic blood pressure (AugSBP) and arterial mean pressure (AugMAP)) derived from blood pressure and aortic valve gradients. Methods: Patients in the Mayo Clinic National Cardiovascular Diseases Registry-TAVR database who underwent TAVR between 1 January 2012 and 30 June 2017 were identified to retrieve baseline clinical, echocardiographic and mortality data. AugSBP, AugMAP and valvulo-arterial impedance (Zva) (Zva) were evaluated using Cox regression. Receiver operating characteristic curve analysis and the c-index were used to assess the model performance against the Society of Thoracic Surgeons (STS) risk score. Results: The final cohort contained 974 patients with a mean age of 81.4 ± 8.3 years old, and 56.6% were male. The mean STS risk score was 8.2 ± 5.2. The median follow-up duration was 354 days, and the one-year all-cause mortality rate was 14.2%. Both univariate and multivariate Cox regression showed that AugSBP and AugMAP parameters were independent predictors for intermediate-term post-TAVR mortality (all p < 0.0001). AugMAP1 < 102.5 mmHg was associated with a 3-fold-increased risk of all-cause mortality 1-year post-TAVR (hazard ratio 3.0, 95%confidence interval 2.0–4.5, p < 0.0001). A univariate model of AugMAP1 surpassed the STS score model in predicting intermediate-term post-TAVR mortality (area under the curve: 0.700 vs. 0.587, p = 0.005; c-index: 0.681 vs. 0.585, p = 0.001). Conclusions: Augmented mean arterial pressure provides clinicians with a simple but effective approach to quickly identify patients at risk and potentially improve post-TAVR prognosis.
Two‐Year Outcomes With a Next‐Generation Left Atrial Appendage Device: Final Results of the PINNACLE FLX Trial
Background The PINNACLE FLX (Protection Against Embolism for Non‐valvular AF [Atrial Fibrillation] Patients: Investigational Device Evaluation of the Watchman FLX LAA [Left Atrial Appendage] Closure Technology) trial evaluated the safety and efficacy of a next‐generation left atrial appendage closure device (WATCHMAN FLX; Boston Scientific, Marlborough, MA). At 1 year, the study met the primary end points of safety and anatomical efficacy/appendage closure. This final report of the PINNACLE FLX trial includes the prespecified secondary end point of ischemic stroke or systemic embolism at 2 years, also making it the first report of 2‐year outcomes with this next‐generation left atrial appendage closure device. Methods and Results Patients with nonvalvular atrial fibrillation with CHA 2 DS 2 ‐VASc score ≥2 (men) or ≥3 (women), with an appropriate rationale for left atrial appendage closure, were enrolled to receive the left atrial appendage closure device at 29 US centers. Adverse events were assessed by an independent clinical events committee, and imaging was assessed by independent core laboratories. Among 395 implanted patients (36% women; mean age, 74 years; CHA 2 DS 2 ‐VASc, 4.2±1.5), the secondary efficacy end point of 2‐year ischemic stroke or systemic embolism was met, with an absolute rate of 3.4% (annualized rate, 1.7%) and an upper 1‐sided 95% confidence bound of 5.3%, which was superior to the 8.7% performance goal. Two‐year rates of adverse events were as follows: 9.3% all‐cause mortality, 5.5% cardiovascular death, 3.4% all stroke, and 10.1% major bleeding (Bleeding Academic Research Consortium 3 or 5). There were no additional systemic embolisms, device embolizations, pericardial effusions, or symptomatic device‐related thrombi after 1 year. Conclusions The secondary end point of 2‐year stroke or systemic embolism was met at 3.4%. In these final results of the PINNACLE FLX trial, the next‐generation WATCHMAN FLX device demonstrated favorable safety and efficacy outcomes.
Evaluation of Scapholunate Injury and Repair with Dynamic (4D) CT: A Preliminary Report of Two Cases
Abstract Background In predynamic or dynamic scapholunate (SL) instability, standard diagnostic imaging may not identify SL interosseous ligament (SLIL) injury, leading to delayed detection and intervention. This study describes the use of four-dimensional computed tomography (4DCT) in identifying early SLIL injury and following injured wrists to 1-year postoperatively. Description of Technique 4DCT acquires a series of three-dimensional volume data with high temporal resolution (66 ms). 4DCT-derived arthrokinematic data can be used as biomarkers of ligament integrity. Patients and Methods This study presents the use of 4DCT in a two-participant case series to assess changes in arthrokinematics following unilateral SLIL injury preoperatively and 1-year postoperatively. Patients were treated with volar ligament repair with volar capsulodesis and arthroscopic dorsal capsulodesis. Arthrokinematics were compared between uninjured, preoperative injured, and postoperative injured (repaired) wrists. Results 4DCT detected changes in interosseous distances during flexion-extension and radioulnar deviation. Generally, radioscaphoid joint distances were greatest in the uninjured wrist during flexion-extension and radioulnar deviation, and SL interval distances were smallest in the uninjured wrist during flexion-extension and radioulnar deviation. Conclusion 4DCT provides insight into carpal arthrokinematics during motion. Distances between the radioscaphoid joint and SL interval can be displayed as proximity maps or as simplified descriptive statistics to facilitate comparisons between wrists and time points. These data offer insight into areas of concern for decreased interosseous distance and increased intercarpal diastasis. This method may allow surgeons to assess whether (1) injury can be visualized during motion, (2) surgery repaired the injury, and (3) surgery restored normal carpal motion. Level of Evidence Level IV, Case series.