Assessment of bone density is an important part of liver transplantation (LT) evaluation for early identification and treatment of osteoporosis. Dual‐energy X‐ray absorptiometry (DXA) is currently the standard clinical test for osteoporosis; however, it may contribute to the appointment burden on LT candidates during the cumbersome evaluation process, and there are limitations affecting its accuracy. In this study, we evaluate the utility of biomechanical analysis of vertebral images obtained during dual‐energy abdominal triple‐phase computed tomography (TPCT) in diagnosing osteoporosis among LT candidates. We retrospectively reviewed cases evaluated for LT between January 2017 and March 2018. All patients who underwent TPCT within 3 months of DXA were included. The biomechanical computed tomography (BCT) analysis was performed at a centralized laboratory (O.N. Diagnostics, Berkeley, CA) by 2 trained analysts blinded to the DXA data. DXA‐based osteoporosis was defined as a T score ≤−2.5 at the hip or spine. BCT‐based osteoporosis was defined as vertebral strength ≤4500 N for women or ≤6500 N for men or trabecular volumetric bone mineral density ≤80 mg/cm3. Comparative data were available for 91 patients who had complete data for both DXA and BCT: 31 women and 60 men, age 54 ± 11 years (mean ± standard deviation), mean body mass index 28 ± 6 kg/m2. Using DXA as the clinical reference, sensitivity of BCT to detect DXA‐defined osteoporosis was 83.3% (20/24 patients) and negative predictive value was 91.7%; specificity and positive predictive value were 65.7% and 46.5%, respectively. BCT analysis of vertebral images on triple‐phase computed tomography, routinely obtained during transplant evaluation, can reliably rule out osteoporosis in LT candidates. Patients with suspicion of osteoporosis on TPCT may need further evaluation by DXA.
Observer Performance for Detection of Pulmonary Nodules at Chest CT over a Large Range of Radiation Dose Levels
Introduction Crohn’s disease diagnosis and monitoring remains a great clinical challenge and often requires multiple testing modalities. Assessing Crohn’s disease activity in the entire gastrointestinal (GI) tract using a panenteric capsule endoscopy (CE) system could be used as an alternative to colonoscopy and cross-sectional imaging. This study assessed the accuracy and safety of panenteric CE in Crohn’s disease as compared with ileocolonoscopy (IC) and/or magnetic resonance enterography (MRE). Methods A prospective, multicentre study was performed in subjects with established Crohn’s disease. Individuals with proven small bowel patency underwent a standardised bowel preparation, followed by CE ingestion and IC either the same or following day. MRE, IC, and CE interpretations were performed by blinded central readers using validated scoring systems. The primary endpoint was the overall sensitivity of CE vs MRE and/or IC in Crohn’s disease subjects. Results Study enrolment included 158 subjects from 21 sites in the USA, Austria, and Israel. Of those, 99 were included in the analysis. Imaging modality scores indicated none to mild inflammation in the proximal small bowel and colon, but discrepant levels of inflammation in the terminal ileum. Overall sensitivity for active enteric inflammation (CE vs MRE and/or IC) was 94% vs 100% (p=0.125) and specificity was 74% vs 22% (p=0.001). Sensitivity of CE was superior to MRE for enteric inflammation in the proximal small bowel (97% vs 71%, p=0.021), and similar to MRE and/or IC in the terminal ileum and colon (p=0.500–0.625). There were seven serious adverse advents of which three were related to the CE device. Conclusion Panenteric CE is a reliable tool for assessing Crohn’s disease mucosal activity and extent compared with more invasive methods. This study demonstrates high performance of the panenteric CE as compared to MRE and/or IC without the need for multiple tests in non-stricturing Crohn’s disease. Trial registration number ClinicalTrials.gov NCT03241368
Image quality in abdominal CT using an iodine contrast reduction algorithm employing patient size and weight and low kV CT technique
Background Low tube potential-high tube current computed tomography (CT) imaging allows reduction in iodine-based contrast dose and may extend the benefit of routine contrast-enhanced CT exams to patients at risk of nephrotoxicity. Purpose To determine the ability of an iodine contrast reduction algorithm to maintain diagnostic image quality for contrast-enhanced abdominal CT. Material and Methods CT exams with iodine contrast reduction were prescribed for patients at risk for renal dysfunction. The iodine contrast reduction algorithm combines weight-based contrast volume reduction with patient width-based low tube potential selection and bolus-tracking. Control exams with routine iodine dose were selected based on weight, width, and scan protocol. Three radiologists evaluated image quality and diagnostic confidence using a 4-point scale (<2 acceptable). Another radiologist assessed contrast reduction indications and measured portal vein and liver contrast-to-noise ratios. Results Forty-six contrast reduction algorithm and control exams were compared (mean creatinine 1.6 vs. 1.2 mg/dL, P ≤ 0.0001). Thirty-nine contrast reduction patients had an eGFR <60 mL/min/1.73m 2 and 15 had single or transplanted kidney. Mean iodine contrast dose was lower in the contrast reduction group (20.9 vs. 39.4 g/mL, P < 0.0001). Diagnostic confidence was rated as acceptable in 95% (131/138) of contrast reduction and 100% of control exams (1.18–1.28 vs. 1.02–1.13, respectively; P > 0.06). Liver attenuation and contrast-to-noise ratio (CNR) were similar ( P = 0.08), but portal vein attenuation and CNR were lower with contrast-reduction (mean 176 vs. 198 HU, P = 0.02; 13 vs. 16, P = 0.0002). Conclusion This size-based contrast reduction algorithm using low kV and bolus tracking reduced iodine contrast dose by 50%, while achieving acceptable image quality in 95% of exams.
Dose Reduction for Sinus and Temporal Bone Imaging Using Photon-Counting Detector CT With an Additional Tin Filter
Objective The aim of this study was to quantitatively demonstrate radiation dose reduction for sinus and temporal bone examinations using high-resolution photon-counting detector (PCD) computed tomography (CT) with an additional tin (Sn) filter. Materials and Methods A multienergy CT phantom, an anthropomorphic head phantom, and a cadaver head were scanned on a research PCD-CT scanner using ultra-high-resolution mode at 100-kV tube potential with an additional tin filter (Sn-100 kV) and volume CT dose index of 10 mGy. They were also scanned on a commercial CT scanner with an energy-integrating detector (EID) following standard clinical protocols. Thirty patients referred to clinically indicated sinus examinations, and two patients referred to temporal bone examinations were scanned on the PCD-CT system after their clinical scans on an EID-CT. For the sinus cohort, PCD-CT scans were performed using Sn-100 kV at 4 dose levels at 10 mGy (n = 9), 8 mGy (n = 7), 7 mGy (n = 7), and 6 mGy (n = 7), and the clinical EID-CT was performed at 120 kV and 13.7 mGy (mean CT volume dose index). For the temporal bone scans, PCD-CT was performed using Sn-100 kV (10.1 mGy), and EID-CT was performed at 120 kV and routine clinical dose (52.6 and 66 mGy). For both PCD-CT and EID-CT, sinus images were reconstructed using H70 kernel at 0.75-mm slice thickness, and temporal bone images were reconstructed using a U70 kernel at 0.6-mm slice thickness. In addition, iterative reconstruction with a dedicated sharp kernel (V80) was used to obtain high-resolution PCD-CT images from a sinus patient scan to demonstrate improved anatomic delineation. Improvements in spatial resolution from the dedicated sharp kernel was quantified using modulation transfer function measured with a wire phantom. A neuroradiologist assessed the H70 sinus images for visualization of critical anatomical structures in low-dose PCD-CT images and routine-dose EID-CT images using a 5-point Likert scale (structural detection obscured and poor diagnostic confidence, score = 1; improved anatomic delineation and diagnostic confidence, score = 5). Image contrast and noise were measured in representative regions of interest and compared between PCD-CT and EID-CT, and the noise difference between the 2 acquisitions was used to estimate the dose reduction in the sinus and temporal bone patient cohorts. Results The multienergy phantom experiment showed a noise reduction of 26% in the Sn-100 kV PCD-CT image, corresponding to a total dose reduction of 56% compared with EID-CT (clinical dose) without compromising image contrast. The PCD-CT images from the head phantom and the cadaver scans demonstrated a dose reduction of 67% and 83%, for sinus and temporal bone examinations, respectively, compared with EID-CT. In the sinus cohort, PCD-CT demonstrated a mean dose reduction of 67%. The 10- and 8-mGy sinus patient images from PCD-CT were significantly superior to clinical EID-CT for visualization of critical sinus structures (median score = 5 ± 0.82 and P = 0.01 for lesser palatine foramina, median score = 4 ± 0.68 and P = 0.039 for nasomaxillary sutures, and median score = 4 ± 0.96 and P = 0.01 for anterior ethmoid artery canal). The 6- and 7-mGy sinus patient images did not show any significant difference between PCD-CT and EID-CT. In addition, V80 (sharp kernel, 10% modulation transfer function = 18.6 cm −1 ) PCD-CT images from a sinus patient scan increased the conspicuity of nasomaxillary sutures compared with the clinical EID-CT images. The temporal bone patient images demonstrated a dose reduction of up to 85% compared with clinical EID-CT images, whereas visualization of inner ear structures such as the incudomalleolar joint were similar between EID-CT and PCD-CT. Conclusions Phantom and cadaver studies demonstrated dose reduction using Sn-100 kV PCD-CT compared with current clinical EID-CT while maintaining the desired image contrast. Dose reduction was further validated in sinus and temporal bone patient studies. The ultra-high resolution capability from PCD-CT allowed improved anatomical delineation for sinus imaging compared with current clinical standard.
Synthesizing images from multiple kernels using a deep convolutional neural network
PurposeFiltering measured projections with a particular convolutional kernel is an essential step in analytic reconstruction of computed tomography (CT) images. A tradeoff between noise and spatial resolution exists for different choices of reconstruction kernel. In a clinical setting, this often requires producing multiple images reconstructed with different kernels for a single CT exam, which increases the burden of computation, networking, archival, and reading. We address this problem by training a deep convolutional neural network (CNN) to synthesize multiple input images into a single output image which exhibits low noise while also preserving features in images reconstructed with the sharpest kernels.MethodsA CNN architecture consisting of repeated blocks of residual units containing a total of 20 convolutional layers was used to combine features. The CNN inputs consisted of two images produced with different reconstruction kernels, one smooth and one sharp, which were stacked in the channel dimension. The network was trained using supervised learning with both full‐dose and simulated quarter‐dose abdominal CT images. After training, the performance was evaluated using a reserved set of full‐dose scans that were not used for network optimization. Noise reduction performance was measured by comparing root mean square (RMS) measurements in uniform regions. Spatial resolution was compared using line profiles of anatomic features.ResultsFor the regions tested, the synthetic images feature noise levels slightly below those of the smooth input images, while maintaining the resolution of anatomic details found in the sharp input images.ConclusionsA deep CNN can be used combine features from CT images reconstructed with different kernels to produce a single synthesized image series that exhibits both low noise and high spatial resolution. This approach has implications for improving image quality, reducing radiation dose, and simplifying the clinical workflow for CT imaging.
State of the Art in Abdominal CT: The Limits of Iterative Reconstruction Algorithms
Imaging Findings of Ileal Inflammation at Computed Tomography and Magnetic Resonance Enterography: What do They Mean When Ileoscopy and Biopsy are Negative?
Abstract Background and Aims Our goal was to determine the importance of ileal inflammation at computed tomography or magnetic resonance enterography in Crohn’s disease patients with normal ileoscopy. Methods Patients with negative ileoscopy and biopsy within 30 days of CT or MR enterography showing ileal inflammation were included. The severity [0–3 scale] and length of inflammation within the distal 20 cm of the terminal ileum were assessed on enterography. Subsequent medical records were reviewed for ensuing surgery, ulceration at ileoscopy, histological inflammation, or new or worsening ileal inflammation or stricture on enterography. Imaging findings were classified as: Confirmed Progression [subsequent surgery or radiological worsening, new ulcers at ileoscopy or positive histology]; Radiologic Response [decreased inflammation with medical therapy]; or Unlikely/Unconfirmed Inflammation. Results Of 1471 patients undergoing enterography and ileoscopy, 112 [8%] had imaging findings of inflammation with negative ileoscopy, and 88 [6%] had negative ileoscopy and ileal biopsy. Half [50%; 44/88] with negative biopsy had moderate/severe inflammation at enterography, with 45%, 32% and 11% having proximal small bowel inflammation, stricture or fistulas, respectively. Two-thirds with negative biopsy [67%; 59/88] had Confirmed Progression, with 68%, 70% and 61% having subsequent surgical resection, radiological worsening or ulcers at subsequent ileoscopy, respectively. Mean length and severity of ileal inflammation in these patients was 10 cm and 1.6. Thirteen [15%] patients had Radiologic Response, and 16 [18%] had Unlikely/Unconfirmed Inflammation. Conclusion Crohn’s disease patients with unequivocal imaging findings of ileal inflammation at enterography despite negative ileoscopy and biopsy are likely to have active inflammatory Crohn’s disease. Disease detected by imaging may worsen over time or respond to medical therapy.