PurposeTo reduce slice‐to‐slice motion effects in multislice ‐weighted fast‐spin‐echo ( FSE) imaging, manifest as “scalloping” in reformats, by modification of the acquisition strategy and to show applicability in prostate MRI.Methods FSE images of contiguous or overlapping slices are typically acquired using multiple passes in which each pass is comprised of multiple slices with slice‐to‐slice gaps. Combination of slices from all passes provides the desired sampling. For enhancement of through‐plane resolution with super resolution or for reformatting into other orientations, subtle ≈1 mm motion between passes can cause objectionable “scalloping” artifact. Here we address this by subdivision of each pass into multiple segments. Interleaving of segments from the multiple passes causes all slices to be acquired over substantially the same time, reducing pass‐to‐pass motion effects. This was implemented in acquiring 78 overlapped FSE axial slices and studied in phantoms and in 14 prostate MRI patients. Super‐resolution axial images and sagittal reformats from the original and new segmented acquisitions were evaluated by 3 uroradiologists.ResultsFor all criteria of sagittal reformats, the segmented acquisition was statistically superior to the original. For all sharpness criteria of axial images, although the trend preferred the original acquisition, the difference was not significant. For artifact in axial images, the segmented acquisition was significantly superior.ConclusionsFor prostate MRI the new segmented acquisition significantly reduces the scalloping motion artifact that can be present in reformats due to long time lags between the acquisition of adjacent or overlapped slices while retaining image sharpness in the acquired axial slices.
Current Imaging Techniques for and Imaging Spectrum of Prostate Cancer Recurrence and Metastasis: A Pictorial Review
AbstractIn 2019, the American Cancer Society (ACS) estimates that 174,650 new cases of prostate cancer will be diagnosed and 31,620 will die due to the prostate cancer in the United States. Prostate cancer is often managed with aggressive curative intent standard therapies including radiotherapy or surgery. Regardless of how expertly done, these standard therapies often bring significant risk and morbidity to the patient's quality of life with potential impact on sexual, urinary, and bowel functions. Additionally, improved screening programs, using prostatic-specific antigen and transrectal ultrasound-guided systematic biopsy, have identified increasing numbers of low-risk, low-grade “localized” prostate cancer. The potential, localized, and indolent nature of many prostate cancers presents a difficult decision of when to intervene, especially within the context of the possible comorbidities of aggressive standard treatments. Active surveillance has been increasingly instituted to balance cancer control versus treatment side effects; however, many patients are not comfortable with this option. Although active debate continues on the suitability of either focal or regional therapy for the low- or intermediate-risk prostate cancer patients, no large consensus has been achieved on the adequate management approach. Some of the largest unresolved issues are prostate cancer multifocality, limitations of current biopsy strategies, suboptimal staging by accepted imaging modalities, less than robust prediction models for indolent prostate cancers, and safety and efficiency of the established curative therapies following focal therapy for prostate cancer. In spite of these restrictions, focal therapy continues to confront the current paradigm of therapy for low- and even intermediate-risk disease. It has been proposed that early detection and proper characterization may play a role in preventing the development of metastatic disease. There is level-1 evidence supporting detection and subsequent aggressive treatment of intermediate- and high-risk prostate cancer. Therefore, accurate assessment of cancer risk (i.e., grade and stage) using imaging and targeted biopsy is critical. Advances in prostate imaging with MRI and PET are changing the workup for these patients, and advances in MR-guided biopsy and therapy are propelling prostate treatment solutions forward faster than ever.
Use of kZ‐space for high through‐plane resolution in multislice MRI: Application to prostate
PurposeThe goal of this work is to demonstrate 1 mm through‐plane resolution in multislice T2SE MRI using k‐space processing of overlapping slices and show applicability in prostate MRI.MethodsMultiple overlapped slices are acquired and Fourier transformed in the slice‐select direction. The slice profile is incorporated into a Tikhonov‐regularized reconstruction. Through‐plane resolution is tested in a resolution phantom. An anthropomorphic prostate phantom is used to study the SNR, and results are compared with theoretical prediction. The proposed method is tested in 16 patients indicated for clinical prostate MRI who gave written informed consent as overseen by our IRB. The “proposed” vs. “reference” multislice images are compared using multiple evaluation criteria for through‐plane resolution.ResultsThe modulation transfer function (MTF) plots of the resolution phantom show good modulation at frequency 0.5 lp/mm, demonstrating 1 mm through‐plane resolution restoration. The SNR measurements experimentally match the theoretically predicted values. The radiological evaluation shows that the proposed method is superior to the reference method for five criteria of sharpness but inferior with respect to artifacts.ConclusionsIn conjunction with overlapped slices a k‐space‐based reconstruction approach can be used to improve through‐plane resolution in multislice T2SE MRI. 1 mm resolution is demonstrated from 3.2 mm thick slices. The in vivo results from prostate MRI show improved sharpness when compared to the standard multislice method.
Safety and Image Quality of 1.5-T Endorectal Coil Multiparametric MRI of the Prostate or Prostatectomy Fossa for Patients With Pacemaker or Implantable Cardioverter-Defibrillator
A multi-reader in vitro study using porcine kidneys to determine the impact of integrated circuit detectors and iterative reconstruction on the detection accuracy, size measurement, and radiation dose for small (
Background Detection of small renal calculi has benefitted from recent advances in computed tomography (CT) scanner design. Information regarding observer performance when using state-of-the-art CT scanners for this application is needed. Purpose To assess observer performance and the impact of radiation dose for detection and size measurement of <4 mm renal stones using CT with integrated circuit detectors and iterative reconstruction. Material and Methods Twenty-nine <4 mm calcium oxalate stones were randomly placed in 20 porcine kidneys in an anthropomorphic phantom. Four radiologists used a workstation to record each calculus detection and size. JAFROC Figure of Merit (FOM), sensitivity, false positive detections, and calculus size were calculated. Results Mean calculus size was 2.2 ± 0.7 mm. The CTDI vol values corresponding to the automatic exposure control settings of 160, 80, 40, 25, and 10 Quality Reference mAs (QRM) were 15.2, 7.9, 4.2, 2.7, and 1.3 mGy, respectively. JAFROC FOM was ≥ 0.97 at ≥ 80 QRM, ≥ 0.89 at ≥ 25 QRM, and was inferior to routine dose (160 QRM) at 10 QRM (0.72, P < 0.05). Per-calculus sensitivity remained ≥ 85% for every reader at ≥ 25 QRM. Mean total false positive detections per reader were ≤ 3 at ≥ 80 QRM, but increased substantially for two readers ( ≥ 12) at ≤ 40 QRM. Measured calculus size significantly decreased at ≤ 25 QRM ( P ≤ 0.01). Conclusion Using low dose renal CT with iterative reconstruction and ≥ 25 QRM results in high sensitivity, but false positive detections increase for some readers at very low dose levels (≤ 40 QRM). At very low doses with iterative reconstruction, measured calculus size will artifactually decrease.
Differentiation of Benign From Metastatic Adrenal Masses in Patients With Renal Cell Carcinoma on Contrast-Enhanced CT