Atrioventricular Node Ablation in Langendorff-Perfused Porcine Hearts Using Carbon Ion Particle Therapy
Richter, Daniel , Prokesch, Hannah, Graeff, Christian , Prall, Matthias, Simoniello, Palma , Fournier, Claudia , Bauer, Julia , Kaderka, Robert, Weymann, Alexander , Szabó, Gábor , Sonnenberg, Karin, Constantinescu, A., Johnson, Susan B., Misiri, Juna, Takami, Mitsuru , Miller, Robert C. , Herman, Michael , Asirvatham, Samuel J. , Jäkel, Oliver , Haberer, Thomas, Durante, Marco , Bert, Christoph , Packer, Douglas L. , Lehmann, H. Immo , Constantinescu, Anna M, Herman, Michael G., Brons, Stephan, Debus, Jürgen, Sonnenberg, Karin, Brons, Stephan , Debus, Jürgen , Bert, Christoph , Durante, Marco , Graeff, Christian , Asirvatham, Samuel J

Circulation: Arrhythmia and Electrophysiology | January 22, 2015 | Volume: 8 | Issue: 2 | Pages: 429-438

10.1161/circep.114.002436 Get It

Background— Particle therapy, with heavy ions such as carbon-12 ( 12 C), delivered to arrhythmogenic locations of the heart could be a promising new means for catheter-free ablation. As a first investigation, we tested the feasibility of in vivo atrioventricular node ablation, in Langendorff-perfused porcine hearts, using a scanned 12C beam. Methods and Results— Intact hearts were explanted from 4 (30–40 kg) pigs and were perfused in a Langendorff organ bath. Computed tomgraphic scans (1 mm voxel and slice spacing) were acquired and 12 C ion beam treatment planning (optimal accelerator energies, beam positions, and particle numbers) for atrioventricular node ablation was conducted. Orthogonal x-rays with matching of 4 implanted clips were used for positioning. Ten Gray treatment plans were repeatedly administered, using pencil beam scanning. After delivery, positron emission tomography-computed tomgraphic scans for detection of β + ( 11 C) activity were obtained. A 12 C beam with a full width at half maximum of 10 mm was delivered to the atrioventricular node. Delivery of 130 Gy caused disturbance of atrioventricular conduction with transition into complete heart block after 160 Gy. Positron emission computed tomgraphy demonstrated dose delivery into the intended area. Application did not induce arrhythmias. Macroscopic inspection did not reveal damage to myocardium. Immunostaining revealed strong γH2AX signals in the target region, whereas no γH2AX signals were detected in the unirradiated control heart. Conclusions— This is the first report of the application of a 12 C beam for ablation of cardiac tissue to treat arrhythmias. Catheter-free ablation using 12C beams is feasible and merits exploration in intact animal studies as an energy source for arrhythmia elimination.
Spatial and Time-Course Thermodynamics During Pulmonary Vein Isolation Using the Second-Generation Cryoballoon in a Canine In Vivo Model
Takami, Mitsuru , Misiri, Juna, Parker, Kay D., Johnson, Susan B., Sarmiento, Ray I., Packer, Douglas L. , Lehmann, H. Immo

Circulation: Arrhythmia and Electrophysiology | December 23, 2014 | Volume: 8 | Issue: 1 | Pages: 186-192

10.1161/circep.114.002137 Get It

Background— Thermodynamics in the left atrium–pulmonary vein (PV) junction, phrenic nerve, and esophagus during PV isolation (PVI) using the second-generation cryoballoon are not known. Methods and Results— Twenty dogs underwent PVI using second-generation cryoballoon. Ablations were performed for ≤2 deliveries based on PVI without a bonus freeze. Inner balloon, balloon surface, and tissue temperatures were monitored during cryoablation. The tissue thermocouples were placed on the epicardial surface of the left atrium–PV junction, as well as on the phrenic nerve and within the esophagus. A total of 259 cryoballoon and 229 tissue tissue thermocouples profiles during 53 cryoablations of 40 PVs were analyzed. Acutely, PVI was achieved in 36 of 40 PVs (90%). Conductive tissue cooling spread radially from the balloon–left atrium–PV contact point. The lowest tissue temperatures were dependent on the distance of the tissue thermocouples to the balloon surface ( r =0.85; P <0.001). In addition, blood flow leaks around the balloon had a warming effect on the balloon and tissue temperature profiles. Chronic isolation (mean, 48±16 days) was achieved in 27 of 36 PVs (75%). In 8 of 9 acutely isolated but with chronic reconnection PVs, the blood flow leak location was concordant with chronic reconnection gap. Although only 1 esophageal ulcerated lesion was observed, neither phrenic nerve palsy nor severe PV stenosis was seen in any dogs. Conclusions— Variance in tissue thermodynamics during cryothermal ablation depends on the distance from balloon and peri-balloon blood flow leaks. This information may be useful for successful PVI without severe complications.
Transvenous Stimulation of the Renal Sympathetic Nerves Increases Systemic Blood Pressure: A Potential New Treatment Option for Neurocardiogenic Syncope
Madhavan, Malini , Ebrille, Elisa , Mulpuru, Siva K. , Mikell, Susan B. , Johnson, Susan B., Suddendorf, Scott H., Ladewig, Dorothy J., Gilles, Emily J., Danielsen, Andrew J., Asirvatham, Samuel J. , DeSimone, Christopher V. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | June 5, 2014 | Volume: 25 | Issue: 10 | Pages: 1115-1118

10.1111/jce.12466 Get It

Renal Vein Stimulation Increases Blood PressureBackgroundNeurocardiogenic syncope (NCS) is a common and sometimes debilitating disorder, with no consistently effective treatment. NCS is due to a combination of bradycardia and vasodilation leading to syncope. Although pacemaker devices have been tried in treating the bradycardic aspect of NCS, no device‐based therapy exists to treat the coexistent vasodilation that occurs. The renal sympathetic innervation has been the target of denervation to treat hypertension. We hypothesized that stimulation of the renal sympathetic nerves can increase blood pressure and counteract vasodilation in NCS.Methods and ResultsHigh‐frequency stimulation (800–900 pps, 10 V, 30–200 seconds) was performed using a quadripolar catheter in the renal vein of 7 dogs and 1 baboon. A significant increase in blood pressure (BP; mean [SD] systolic BP 117 [±28] vs. 128 [±33], diastolic BP 75 [±19] vs. 87 [±29] mmHg) was noted during the stimulation, which returned to baseline after cessation of stimulation. The mean increase in systolic and diastolic BP was 13.0 (±3.3) (P = 0.006) and 10.2 (±4.6) (P = 0.08), respectively.ConclusionWe report the first ever study of feasibility and safety of high‐frequency electrical stimulation of the renal sympathetic innervation to increase BP in animal models. This has potential applications in the treatment of hypotensive states such as NCS.
Compatibility of Electroanatomical Mapping Systems with a Concurrent Percutaneous Axial Flow Ventricular Assist Device
Vaidya, Vaibhav R. , Madhavan, Malini , Noheria, Amit , Shahid, Mohammed , Walters, Jacob, Ladewig, Dorothy J., Mikell, Susan B. , Johnson, Susan B., Suddendorf, Scott H., Asirvatham, Samuel J. , DeSimone, Christopher V. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | April 24, 2014 | Volume: 25 | Issue: 7 | Pages: 781-786

10.1111/jce.12437 Get It

Electromagnetic Interference with Ventricular Assist DeviceBackgroundHemodynamic instability hinders activation and entrainment mapping during ventricular tachycardia ablation. The Impella 2.5 microaxial flow device (MFD; Abiomed Inc., Danvers, MA, USA) is used to prevent hemodynamic instability during electrophysiologic study. However, electromagnetic interference (EMI) generated by this device can preclude accurate electroanatomic mapping.MethodsImpella was placed in the left ventricle of 7 canines for circulatory support. Electroanatomic mapping during sinus rhythm, ventricular pacing, and ventricular fibrillation (VF) was performed using magnet‐ (CARTO3, Biosense Webster Inc., Diamond Bar, CA, USA) and impedance‐ (EnSite Velocity System/EnSite NavX, St. Jude Medical Inc., St. Paul, MN, USA) based systems. Distance from device to points with severe EMI precluding acquisition was compared to points with mild/no EMI. Two methods were used to reduce EMI: (1) titration of MFD performance, and (2) impedance‐only mapping combined with manual annotation of activation.ResultsSevere EMI did not occur during impedance‐based mapping. Severe EMI was observed using CARTO3 at 9.4% of all points attempted at maximum performance level (P8) of device. Severe EMI occurred at points closer to device (40.1 ± 16.8 mm) versus (55.5 ± 20.0 mm) for mild/no EMI, P < 0.0001. Severe EMI using CARTO3 was resolved by either (1) reduction of performance from P8 to P6 or (2) impedance‐only mapping with manual annotation.ConclusionConcurrent use of MFD caused EMI to prevent acquisition of points with magnet‐based mapping. Predictors for EMI were distance from device and performance level. Temporary reductions to P6 or impedance‐only mapping are 2 methods to resolve EMI.
β-Adrenergic Augmentation of Flecainide-Induced Conduction Slowing in Canine Purkinje Fibers
Cragun, Kevin T., Johnson, Susan B., Packer, Douglas L.

Circulation | June 12, 2012 | Volume: 96 | Issue: 8 | Pages: 2701-2708

10.1161/01.cir.96.8.2701 Get It

Background This study was undertaken to test the hypothesis that β-adrenergic stimulation in the setting of membrane depolarization will potentiate flecainide-induced conduction slowing. Methods and Results To elucidate the potential mechanism for the flecainide proarrhythmia observed in CAST, the voltage dependence of β-adrenergic modulation of impulse propagation in eight flecainide-superfused canine Purkinje fibers was examined with a dual-microelectrode technique. At physiological membrane potentials (V m ) ([K + ] o =5.4 μmol), 1 μmol flecainide decreased V̇ max from 698±55 to 610±72 V/s ( P =.003) and squared conduction velocity (θ 2 ) from 2.11±1.1 to 1.72±0.9 (m/s) 2 ( P =.001). With K + depolarization to V m =−70 mV, flecainide further reduced V̇ max from 306±101 to 245±65 V/s and θ 2 from 1.12±0.4 to 0.99±0.6 (m/s) 2 , producing a 2.0-mV hyperpolarizing shift of apparent Na + channel availability curves derived from θ 2 . The addition of 1 μmol isoproterenol to flecainide-superfused fibers at physiological V m increased θ 2 by 8% to 1.84±0.6 (m/s) 2 ( P <.01) without altering V̇ max . At −70 mV, the addition of isoproterenol magnified the flecainide-induced reduction of V̇ max an additional 24% to 185±52 V/s ( P <.01) and θ 2 by 17% to 0.82±0.5 (m/s) 2 ( P =.04), producing an additional 1.8-mV ( P =.002) and 1.9-mV ( P =.002) hyperpolarizing shift in the apparent Na + channel inactivation curves generated from V̇ max and θ 2 , respectively. At physiological V m , the action potential duration (APD 95 ) was reduced from 307±35 to 269±27 ms ( P <.001) by flecainide and subsequently to 217±4 ms ( P <.001) with isoproterenol addition. With 12 mmol/L K + , APD 95 decreased from 198±23 to 182±17 ms ( P =.005) with flecainide and to 164±10 ms ( P =.004) with isoproterenol. Conclusions At depolarized V m , isoproterenol amplified the flecainide-induced reduction of V̇ max and θ 2 , suggesting a further adrenergic-mediated reduction of Na + current. Consequently, the synergy between catecholamines and flecainide at depolarized V m and the shortened APD 95 could facilitate arrhythmogenesis in the presence of underlying ischemia.
Three-Dimensional Ultrasound for Image-Guided Mapping and Intervention
Henz, Benhur Davi , Johnson, Susan B., Bunch, T. Jared , O'BRIEN, CHRISTINE J., Hodge, David O. , Altman, Andres, Govari, Assaf , Packer, Douglas L. , Okumura, Yasuo

Circulation: Arrhythmia and Electrophysiology | April 30, 2008 | Volume: 1 | Issue: 2 | Pages: 110-119

10.1161/circep.108.769935 Get It

Background— Multiple factors create discrepancies between electroanatomic maps and merged, preacquired computed tomographic images used in guiding atrial fibrillation ablation. Therefore, a Carto-based 3D ultrasound image system (Biosense Webster Inc) was validated in an animal model and tested in 15 atrial fibrillation patients. Methods and Results— Twelve dogs underwent evaluation using a newly developed Carto-based 3D ultrasound system. After fiducial clip markers were percutaneously implanted at critical locations in each cardiac chamber, 3D ultrasound geometries, derived from a family of 2D intracardiac echocardiographic images, were constructed. Point-source error of 3D ultrasound-derived geometries, assessed by actual real-time 2D intracardiac echocardiographic clip sites, was 2.1�1.1 mm for atrial and 2.4�1.2 mm for ventricular sites. These errors were significantly less than the variance on CartoMerge computed tomographic images (atria: 3.3�1.6 mm; ventricles: 4.8�2.0 mm; P< 0.001 for both). Target ablation at each clip, guided only by 3D ultrasound-derived geometry, resulted in lesions within 1.1�1.1 mm of the actual clips. Pulmonary vein ablation guided by 3D ultrasound-derived geometry resulted in circumferential ablative lesions. Mapping in 15 patients produced modestly smaller 3D ultrasound versus electroanatomic map left atrial volumes (98�24 cm 3 versus 109�25 cm 3 , P< 0.05). Three-dimensional ultrasound-guided pulmonary vein isolation and linear ablation in these patients were successfully performed with confirmation of pulmonary vein entrance/exit block. Conclusions— These data demonstrate that 3D ultrasound images seamlessly yield anatomically accurate chamber geometries. Image volumes from the ultrasound system are more accurate than possible with CartoMerge computed tomographic imaging. This clinical study also demonstrates the initial feasibility of this guidance system for ablation in patients with atrial fibrillation.
Impact of Transforming Growth Factor-β1 on Atrioventricular Node Conduction Modification by Injected Autologous Fibroblasts in the Canine Heart
Bunch, T. Jared , Mahapatra, Srijoy, Bruce, G. Keith, Johnson, Susan B., Miller, Dylan V. , Horne, Benjamin D. , Wang, Xiao-Li, Lee, Hon-Chi, Caplice, Noel M. , Packer, Douglas L. , Wang, Shaohua , Wang, Xiao-Li

Circulation | May 23, 2006 | Volume: 113 | Issue: 21 | Pages: 2485-2494

10.1161/circulationaha.105.570796 Get It

Background— Atrioventricular (AV) nodal ablation for management of atrial fibrillation (AF) is irreversible and requires permanent pacemaker implantation. We hypothesized that as an alternative, implantation of autologous fibroblasts in the perinodal region would focally modify AV nodal conduction and that this modulation would be enhanced by pretreatment with transforming growth factor-β1 (TGF-β1), a stimulant of fibroblasts. Methods and Results— Skin biopsies were taken from 12 mongrel dogs, and derived fibroblasts were dissociated and grown in culture for 2 weeks. Multiple injections (0.25 mL) were made through an 8F NOGA catheter along the fast/slow AV nodal pathways as guided by an electroanatomic mapping system. Seven dogs received fibroblasts alone (1×10 6 cells/mL), 7 dogs received TGF-β1 (5 μg), 4 dogs received fibroblasts and TGF-β1 (1×10 6 cells/mL+5 μg), and 4 dogs received saline only. AV node function was assessed at baseline and after 4 weeks. Saline (80 mL) with assigned therapy (0.25 mL per injection) was injected into the peri-AV nodal region in each dog. At baseline, the AH interval (66±3 ms) and the average RR interval (331±17 ms) in pacing-induced AF were similar in each cohort. The increase in AH interval in normal sinus rhythm was longer after fibroblast (23±4 versus 5±5 ms; P =0.05) and fibroblast plus TGF-β1 (50±5 versus 5±5 ms; P <0.001) injections than with saline alone, with similar findings during high right atrium and distal coronary sinus pacing. The AH interval was not significantly increased after TGF-β1 injections. The AH interval was significantly longer after fibroblast plus TGF-β1 injections than with either therapy (TGF-β1 or fibroblasts) alone. The RR interval during AF was increased in dogs that received fibroblasts alone (110±36 versus −41±34 ms) and to a greater extent with the addition of TGF-β1 (294±108 versus −41±34 ms). No AV block was seen in any cohort at 4 weeks. Labeled fibroblasts that expressed vimentin were identified in all dogs that received cell injections at 4 weeks. Conclusions— AV nodal modification can be achieved with injected fibroblasts without the creation of AV block. The effect on AV node conduction is substantially enhanced by pretreatment of fibroblasts with TGF-β1. These data have therapeutic potential for the management of rapid ventricular rate during AF without pacemaker implantation.
Discrepancies Between Catheter Tip and Tissue Temperature in Cooled-Tip Ablation
Bruce, G. Keith, Bunch, T. Jared , Milton, Mark A., Sarabanda, Álvaro Valentim Lima , Johnson, Susan B., Packer, Douglas L.

Circulation | August 8, 2005 | Volume: 112 | Issue: 7 | Pages: 954-960

10.1161/circulationaha.104.492439 Get It

Background— It is not known whether catheter tip temperatures with a cooled-tip ablation can be reliably extrapolated to estimate actual tissue temperatures. The relationship between catheter tip temperatures, tissue temperatures, power, and microbubble formation is not known. Methods and Results— Nine dogs underwent 111 radiofrequency energy deliveries at the pulmonary vein ostia with a cooled-tip catheter. Catheter tip and tissue temperatures were markedly discrepant. Catheter tip temperature plateaus at 36°C to 39°C with increasing power, whereas tissue temperature increases to a mean of 75±3°C at 45 W (maximum temperature >100°C). Seventy-two energy deliveries were performed, titrating power to microbubble formation guided by intracardiac echocardiography. Type I and II microbubble formation occurred in 45 (63%) and 19 (26%) ablations, respectively. Type I microbubble emergence occurred at lower powers (21±8 versus 26±4 W; P =0.05), catheter tip temperatures (38±5°C versus 48±10°C; P =0.02), and tissue temperatures (65±19°C versus 81±9°C; P <0.001) than type II microbubble formation. Maximum impedance decreases during ablation before microbubble formation were less with type I microbubble (20±9 versus 37±11 Ω; P <0.001) compared with type II microbubbles. One quarter of type I microbubbles abruptly transitioned to type II microbubbles with significant changes in power or catheter tip temperature. No microbubbles were seen in 19 ablations (26%) despite powers up to 26±9 W and tissue temperatures up to 81±17°C. Conclusions— Catheter tip and tissue temperatures are markedly discrepant during cooled-tip ablation. Type I and II microbubble formation occurs at overlapping power and catheter tip and tissue temperature ranges. Neither the absence of microbubbles nor the presence of type I microbubble formation ensures against excessive tissue heating. The appearance of microbubbles may indicate possible tissue overheating and signal a need to decrease energy.
Analysis of Catheter-Tip (8-mm) and Actual Tissue Temperatures Achieved During Radiofrequency Ablation at the Orifice of the Pulmonary Vein
Bunch, T. Jared , Bruce, G. Keith, Johnson, Susan B., Sarabanda, Álvaro Valentim Lima , Milton, Mark A., Packer, Douglas L.

Circulation | October 25, 2004 | Volume: 110 | Issue: 19 | Pages: 2988-2995

10.1161/01.cir.0000146905.19945.99 Get It

Background— Many ablative approaches in or near the orifice of the pulmonary vein (PV) have demonstrated success in eliminating atrial fibrillation. Despite current practice, there are no data regarding the in vivo efficacy and safety of an 8-mm catheter tip for ablation at the PV orifice. Methods and Results— Ten mongrel dogs were studied. Thermocouples were implanted in the atrial muscle of the PV orifice. Intracardiac echocardiography monitored catheter position, tip/tissue orientation, and microbubble formation. Ninety-four ablations were performed for 120 seconds. A temperature discrepancy >10°C between the catheter tip and tissue occurred during 47 (50%) of the ablations. Despite termination of energy delivery, the average tissue temperature remained within 1°C of the achieved steady state for 9 seconds. A temperature discrepancy >10°C was more common in the right superior PV, with oblique catheter positioning, when tissue temperatures were >60°C or 80°C, and with type 1 or type 2 microbubble formation. However, microbubbles were not present in 7 (13%, type 1) and 10 (40%, type 2) ablations with tissue temperatures >80°C. The maximum tissue temperature achieved with non–full-thickness lesions was 47.3±7.4°C vs 75.9±11.7°C ( P <0.0001) for full-thickness lesions. Conclusions— Marked discrepancies between catheter-tip and tissue temperatures occurred with higher temperatures, prolonged ablation times, and unfavorable catheter thermistor–tissue contact. Also, these data suggest a conservative approach to atrial ablation, because full-thickness lesions were obtained when tissue temperatures reached 50°C to 60°C and the tissue retained high heat levels despite termination of radiofrequency energy. Finally, microbubbles are inconsistent markers of tissue overheating.