P-425 Utility of non-contact mapping technique for identification and ablation of non-pulmonary vein foci
Leite, Luiz, Monahan, Kristi H. , Sarabanda, Álvaro Valentim Lima , Peterson, Lori Ann, Bluhm, Christine M., Munger, Thomas M. , Packer, D. L., Asirvatham, Samuel J.

EP Europace | January 31, 2012 | Volume: 4 | Issue: Supplement_2 | Pages: B166-B166

10.1016/eupace/4.supplement_2.b166-b Get It

Discrepancies Between Catheter Tip and Tissue Temperature in Cooled-Tip Ablation
Bruce, G. Keith, Bunch, T. Jared , Milton, Mark A., Sarabanda, Álvaro Valentim Lima , Johnson, Susan B., Packer, Douglas L.

Circulation | August 8, 2005 | Volume: 112 | Issue: 7 | Pages: 954-960

10.1161/circulationaha.104.492439 Get It

Background— It is not known whether catheter tip temperatures with a cooled-tip ablation can be reliably extrapolated to estimate actual tissue temperatures. The relationship between catheter tip temperatures, tissue temperatures, power, and microbubble formation is not known. Methods and Results— Nine dogs underwent 111 radiofrequency energy deliveries at the pulmonary vein ostia with a cooled-tip catheter. Catheter tip and tissue temperatures were markedly discrepant. Catheter tip temperature plateaus at 36°C to 39°C with increasing power, whereas tissue temperature increases to a mean of 75±3°C at 45 W (maximum temperature >100°C). Seventy-two energy deliveries were performed, titrating power to microbubble formation guided by intracardiac echocardiography. Type I and II microbubble formation occurred in 45 (63%) and 19 (26%) ablations, respectively. Type I microbubble emergence occurred at lower powers (21±8 versus 26±4 W; P =0.05), catheter tip temperatures (38±5°C versus 48±10°C; P =0.02), and tissue temperatures (65±19°C versus 81±9°C; P <0.001) than type II microbubble formation. Maximum impedance decreases during ablation before microbubble formation were less with type I microbubble (20±9 versus 37±11 Ω; P <0.001) compared with type II microbubbles. One quarter of type I microbubbles abruptly transitioned to type II microbubbles with significant changes in power or catheter tip temperature. No microbubbles were seen in 19 ablations (26%) despite powers up to 26±9 W and tissue temperatures up to 81±17°C. Conclusions— Catheter tip and tissue temperatures are markedly discrepant during cooled-tip ablation. Type I and II microbubble formation occurs at overlapping power and catheter tip and tissue temperature ranges. Neither the absence of microbubbles nor the presence of type I microbubble formation ensures against excessive tissue heating. The appearance of microbubbles may indicate possible tissue overheating and signal a need to decrease energy.
Analysis of Catheter-Tip (8-mm) and Actual Tissue Temperatures Achieved During Radiofrequency Ablation at the Orifice of the Pulmonary Vein
Bunch, T. Jared , Bruce, G. Keith, Johnson, Susan B., Sarabanda, Álvaro Valentim Lima , Milton, Mark A., Packer, Douglas L.

Circulation | October 25, 2004 | Volume: 110 | Issue: 19 | Pages: 2988-2995

10.1161/01.cir.0000146905.19945.99 Get It

Background— Many ablative approaches in or near the orifice of the pulmonary vein (PV) have demonstrated success in eliminating atrial fibrillation. Despite current practice, there are no data regarding the in vivo efficacy and safety of an 8-mm catheter tip for ablation at the PV orifice. Methods and Results— Ten mongrel dogs were studied. Thermocouples were implanted in the atrial muscle of the PV orifice. Intracardiac echocardiography monitored catheter position, tip/tissue orientation, and microbubble formation. Ninety-four ablations were performed for 120 seconds. A temperature discrepancy >10°C between the catheter tip and tissue occurred during 47 (50%) of the ablations. Despite termination of energy delivery, the average tissue temperature remained within 1°C of the achieved steady state for 9 seconds. A temperature discrepancy >10°C was more common in the right superior PV, with oblique catheter positioning, when tissue temperatures were >60°C or 80°C, and with type 1 or type 2 microbubble formation. However, microbubbles were not present in 7 (13%, type 1) and 10 (40%, type 2) ablations with tissue temperatures >80°C. The maximum tissue temperature achieved with non–full-thickness lesions was 47.3±7.4°C vs 75.9±11.7°C ( P <0.0001) for full-thickness lesions. Conclusions— Marked discrepancies between catheter-tip and tissue temperatures occurred with higher temperatures, prolonged ablation times, and unfavorable catheter thermistor–tissue contact. Also, these data suggest a conservative approach to atrial ablation, because full-thickness lesions were obtained when tissue temperatures reached 50°C to 60°C and the tissue retained high heat levels despite termination of radiofrequency energy. Finally, microbubbles are inconsistent markers of tissue overheating.