Back to Authors

Noheria, Amit

https://orcid.org/0000-0002-9947-3849

Mayo Clinic

Cedars-Sinai Medical Center

Citations 13

Abstract 9770: Anatomic Findings and Myocardial Extensions Into the Thoracic Venous Connections of the Heart
Lachman, Nirusha , Edwards, William D. , Gami, Apoor S., Talreja, Deepak, Friedman, Paul A. , Munger, Thomas M. , Hammill, Stephen C., Packer, Douglas L. , DeSimone, Christopher V. , Noheria, Amit , Asirvatham, Samuel J.

Circulation | April 23, 2024 | Volume: 124 | Issue: suppl_21 | Pages: No page available

10.1161/circ.124.suppl_21.a9770 Get It

Introduction: Cardiac veins serve as substrate for arrhythmogenesis, and are especially involved as foci in atrial fibrillation. Understanding cardiac vein anatomy along with myocardial extension into these structures can improve electrophysiological mapping and electrical isolation of arrhythmogenic substrate. Accurately defining cardiac vein anatomy is critical in improving success of ablation therapy for atrial fibrillation. Methods: We performed measurements on 620 formalin-fixed autopsy hearts explanted from October 1998 to July 2003. The integrity of the thoracic veins and their cardiac connections were examined and systematic measurements of the superior and inferior vena cavae, azygous vein, vein of Marshall, coronary sinus, and pulmonary veins were performed and data were analyzed using univariate statistics. Results: We found that muscular extensions into the pulmonary veins were visible in 99% of the examined hearts, and were circumferential around the vein ostia (99.6%). Muscle extension into the SVC was found in 78% of examined hearts. These extensions were largely circumferential around the ostium (39%), but were also found to be asymmetric in a majority of hearts. Asymmetry was found in hearts with longer muscle extensions; no symmetry was observed in extensions greater than 0.8cm. Muscle extensions into the IVC were not seen. Occasionally, macroscopic muscle extensions into the azygous vein were visible (6%). The vein of Marshall was found to be patent to probing in the majority of hearts examined (72%) and was almost always overlying the lateral left atrial endocardial ridge. Conclusions: Our data suggest that all pulmonary veins need to be electrically isolated during atrial fibrillation ablation because of the almost universal presence of myocardial tissue extending into the veins. Mapping of the SVC should be done circumferentially and if potentials are noted isolation should also be performed. The IVC did not have muscle extensions and is unlikely to be a site of arrhythmogenesis. The azygous vein occasionally had muscle extensions and thus requires mapping and possible isolation. The vein of Marshall can be a substrate for arrhythmogenesis and is accessible for ablation by targeting the lateral left atrial endocardial ridge.
Abstract 9992: Rhythm Control Versus Rate Control and Clinical Outcomes in Patients With Atrial Fibrillation: Results From the Outcomes Registry for Better Informed Treatment of Atrial Fibrillation (ORBIT-AF)
Shrader, Peter, Piccini, Jonathan P. , Kowey, Peter R. , Reiffel, James A. , Thomas, Laine , Noheria, Amit , Fonarow, Gregg C. , Mahaffey, Kenneth W. , Naccarelli, Gerald V. , Noseworthy, Peter A. , Steinberg, Benjamin A. , Peterson, Eric D. , Gersh, Bernard J.

Circulation | March 19, 2022 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.9992 Get It

Introduction: Randomized trials have not demonstrated significant differences in stroke, heart failure or mortality between rhythm and rate control strategies for management of atrial fibrillation (AF). The comparative outcomes in contemporary clinical practice are not well described. The objective of this study was to evaluate outcomes in clinical practice with rhythm control versus rate control strategy. Methods: Patients managed with a rhythm control strategy targeting maintenance of sinus rhythm were retrospectively compared with a strategy of rate control alone in a AF registry across various US practice settings. Unadjusted and adjusted (inverse-propensity weighted) outcomes were estimated. Results: The overall study population (n=6988) had a median age of 74 (25th, 75th percentile 65, 81) years, 56% were males, 77% had first detected or paroxysmal AF and 89% had CHA2DS2-VASc score ≥2. In unadjusted analyses, rhythm control was associated with lower all-cause death, cardiovascular death, first stroke/non-central nervous system systemic embolization/transient ischemic attack, or first major bleeding event (all p<0.05); however, rhythm control was associated with more cardiovascular hospitalizations (HR 1.24, 95% CI 1.10-1.39, p=0.0003; Figure). Conclusion: Among patients with AF in clinical practice, rhythm control was not superior to rate control strategy for outcomes of stroke, heart failure, or mortality, but was associated with more cardiovascular hospitalizations.
Single-site ventricular pacing via the coronary sinus in patients with tricuspid valve disease
Noheria, Amit , Zyl, Martin van , Scott, Luis R. , Madhavan, Malini , Asirvatham, Samuel J. , Van Zyl, Martin, Asirvatham, Samuel J , Srivathsan, Komandoor , McLeod, Christopher J.

EP Europace | January 24, 2018 | Volume: 20 | Issue: 4 | Pages: 636-642

10.1093/europace/euw422 Get It

Endocardial Device Leads in Patients with Patent Foramen Ovale: Echocardiographic Correlates of Stroke/TIA and Mortality
Ponamgi, Shiva , Vaidya, Vaibhav R. , Noheria, Amit , Hodge, David O. , Slusser, Joshua P. , Ammash, Naser M., Friedman, Paul A. , Asirvatham, Samuel J. , Ponamgi, Shiva P , Bruce, Charles J. , DeSimone, Christopher V. , Rabinstein, Alejandro A. , Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | December 12, 2016 | Volume: 40 | Issue: 3 | Pages: 310-322

10.1111/pace.12985 Get It

BackgroundEchocardiographically detected patent foramen ovale (PFO) has been associated with stroke/transient ischemic attack (TIA) in patients with cardiac implantable electronic devices (CIEDs). We sought to evaluate the relationship between echocardiographic characteristics and risk of stroke/TIA and mortality in CIED patients with PFO.MethodsIn 6,086 device patients, PFO was detected in 319 patients. A baseline echocardiogram was present in 250 patients, with 186 having a follow‐up echocardiogram.ResultsOf 250 patients with a baseline echocardiogram, 9.6% (n = 24) had a stroke/TIA during mean follow‐up of 5.3 ± 3.1 years; and 42% (n = 105) died over 7.1 ± 3.7 years. Atrial septal aneurysm, prominent Eustachian valve, visible shunting across PFO, baseline or change in estimated right ventricular systolic pressure (RVSP)/tricuspid regurgitation (TR), or maximum RVSP were not associated with postimplant stroke/TIA (P > 0.05). An exploratory multivariate analysis using time‐dependent Cox models showed increased hazard of death in patients with increase in TR ≥2 grades (hazard ratio [HR] 1.780, 95% confidence interval [CI] 1.447–2.189, P < 0.0001), or increase in RVSP by >10 mm Hg (HR 2.018, 95% CI 1.593–2.556, P < 0.0001), or maximum RVSP in follow‐up (HR 1.432, 95% CI 1.351–1.516, P < 0.0001). A significant increase (P < 0.001) in TR was also noted during follow‐up.ConclusionsIn patients with CIED and PFO, structural and hemodynamic echocardiographic markers did not predict future stroke/TIA. However, a significantly higher TR or RVSP was associated with higher mortality.
Unusual Atrioventricular Reentry Tachycardia in Congenitally Corrected Transposition of Great Arteries
Noheria, Amit , Asirvatham, Samuel J. , McLeod, Christopher J. , Asirvatham, Samuel J

Circulation: Arrhythmia and Electrophysiology | May 24, 2016 | Volume: 9 | Issue: 6 | Pages: No page available

10.1161/circep.116.004120 Get It

Trends in Use and Adverse Outcomes Associated with Transvenous Lead Removal in the United States
Deshmukh, Abhishek , Patel, Nileshkumar , Patel, Nileshkumar, Patel, Achint , Patel, Nilay, Patel, Nilay, Arora, Shilpkumar , Noheria, Amit , Mulpuru, Siva K. , Badheka, Apurva, Fischer, Avi, Coffey, James O., Cha, Yong‐Mei , Friedman, Paul A. , Asirvatham, Samuel J. , Viles-González, Juan F., Patel, Achint A, Kapa, Suraj , Mulpuru, Siva, Patel, Nileshkumar, Noseworthy, Peter A. , Patel, Nilay, Patel, Nilay, Asirvatham, Samuel J

Circulation | November 4, 2015 | Volume: 132 | Issue: 25 | Pages: 2363-2371

10.1161/circulationaha.114.013801 Get It

Background— Transvenous lead removal (TLR) has made significant progress with respect to innovation, efficacy, and safety. However, limited data exist regarding trends in use and adverse outcomes outside the centers of considerable experience for TLR. The aim of our study was to examine use patterns, frequency of adverse events, and influence of hospital volume on complications. Methods and Results— Using the Nationwide Inpatient Sample, we identified 91 890 TLR procedures. We investigated common complications including pericardial complications (hemopericardium, cardiac tamponade, or pericardiocentesis), pneumothorax, stroke, vascular complications (consisting of hemorrhage/hematoma, incidents requiring surgical repair, and accidental arterial puncture), and in-hospital deaths described with TLR, defining them by the validated International Classification of Diseases, Ninth Revision, Clinical Modification diagnosis code. We specifically assessed in-hospital death (2.2%), hemorrhage requiring transfusion (2.6%), vascular complications (2.0%), pericardial complications (1.4%), open heart surgery (0.2%), and postoperative respiratory failure (2.4%). Independent predictors of complications were female sex and device infections. Hospital volume was not independently associated with higher complications. There was a significant rise in overall complication rates over the study period. Conclusions— The overall complication rate in patients undergoing TLR was higher than previously reported. Female sex and device infections are associated with higher complications. Hospital volume was not associated with higher complication rates. The number of adverse events in the literature likely underestimates the actual number of complications associated with TLR.
Effects on Repolarization Using Dynamic QT Interval Monitoring in Long‐QT Patients Following Left Cardiac Sympathetic Denervation
Bos, J. Martijn , Bos, Katy M., Liang, Jackson J. , Patel, Nikhil A. , Hodge, David O. , Noheria, Amit , Asirvatham, Samuel J. , Ackerman, Michael J. , DeSimone, Christopher V. , Asirvatham, Samuel J , Bos, Johan M , Liang, Jackson

Journal of Cardiovascular Electrophysiology | January 5, 2015 | Volume: 26 | Issue: 4 | Pages: 434-439

10.1111/jce.12609 Get It

Dynamic QT Interval Monitoring Post‐LCSDBackgroundVideoscopic left cardiac sympathetic denervation (LCSD) is an adjunct therapy for reduction of arrhythmia‐induced events in patients with long‐QT syndrome (LQTS). LCSD reduces LQTS‐triggered breakthrough cardiac events. The temporal effects of QTc changes post‐LCSD have not been studied.MethodsWe utilized continuous QTc monitoring on 72 patients with LQTS. We evaluated acute and long‐term QTc changes in comparison to 12‐lead ECG‐derived QTc values prior to surgery, 24 hours postsurgery, and at follow up ≥3 months.ResultsSeventy‐two patients underwent LCSD at our institution (46% male, mean age at LCSD was 14 ± 10 years). The mean baseline, pre‐LCSD QTc was 505 ± 56 ms, which had decreased significantly at ≥3 months post‐LCSD to 491 ± 40 ms (P = 0.001). QTc monitoring revealed that the majority of the cohort (53/72; 74%) had a transient increase >30 ms in QTc from baseline, with an average maximum increase of 72 ± 30 ms. Resolution within 10 ms of baseline or less occurred in 57% (30/53) at 24 hours post‐LCSD.ConclusionsAlthough LQTS patients may have a paradoxically increased QTc post‐LCSD, the effects are transient in most patients. Importantly, no patients experienced any arrhythmias in the postoperative setting related to this transient rise in QTc.
Response to Letters Regarding Article, “Stroke or Transient Ischemic Attack in Patients With Transvenous Pacemaker or Defibrillator and Echocardiographically Detected Patent Foramen Ovale”
Friedman, Paul A. , Noheria, Amit , Ackerman, Michael J. , Asirvatham, Samuel J. , Aakre, Christopher A. , Vaidya, Vaibhav R. , Bdeir, Sami, Slusser, Joshua P. , Hodge, David O. , DeSimone, Christopher V. , DeSimone, Daniel C. , Patel, Nikhil A. , Rabinstein, Alejandro A. , Asirvatham, Samuel J

Circulation | July 7, 2014 | Volume: 130 | Issue: 2 | Pages: No page available

10.1161/circulationaha.114.009351 Get It

Compatibility of Electroanatomical Mapping Systems with a Concurrent Percutaneous Axial Flow Ventricular Assist Device
Vaidya, Vaibhav R. , Madhavan, Malini , Noheria, Amit , Shahid, Mohammed , Walters, Jacob, Ladewig, Dorothy J., Mikell, Susan B. , Johnson, Susan B., Suddendorf, Scott H., Asirvatham, Samuel J. , DeSimone, Christopher V. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | April 24, 2014 | Volume: 25 | Issue: 7 | Pages: 781-786

10.1111/jce.12437 Get It

Electromagnetic Interference with Ventricular Assist DeviceBackgroundHemodynamic instability hinders activation and entrainment mapping during ventricular tachycardia ablation. The Impella 2.5 microaxial flow device (MFD; Abiomed Inc., Danvers, MA, USA) is used to prevent hemodynamic instability during electrophysiologic study. However, electromagnetic interference (EMI) generated by this device can preclude accurate electroanatomic mapping.MethodsImpella was placed in the left ventricle of 7 canines for circulatory support. Electroanatomic mapping during sinus rhythm, ventricular pacing, and ventricular fibrillation (VF) was performed using magnet‐ (CARTO3, Biosense Webster Inc., Diamond Bar, CA, USA) and impedance‐ (EnSite Velocity System/EnSite NavX, St. Jude Medical Inc., St. Paul, MN, USA) based systems. Distance from device to points with severe EMI precluding acquisition was compared to points with mild/no EMI. Two methods were used to reduce EMI: (1) titration of MFD performance, and (2) impedance‐only mapping combined with manual annotation of activation.ResultsSevere EMI did not occur during impedance‐based mapping. Severe EMI was observed using CARTO3 at 9.4% of all points attempted at maximum performance level (P8) of device. Severe EMI occurred at points closer to device (40.1 ± 16.8 mm) versus (55.5 ± 20.0 mm) for mild/no EMI, P < 0.0001. Severe EMI using CARTO3 was resolved by either (1) reduction of performance from P8 to P6 or (2) impedance‐only mapping with manual annotation.ConclusionConcurrent use of MFD caused EMI to prevent acquisition of points with magnet‐based mapping. Predictors for EMI were distance from device and performance level. Temporary reductions to P6 or impedance‐only mapping are 2 methods to resolve EMI.
Stroke or Transient Ischemic Attack in Patients With Transvenous Pacemaker or Defibrillator and Echocardiographically Detected Patent Foramen Ovale
Friedman, Paul A. , Noheria, Amit , Bdeir, Sami, Aakre, Christopher A. , Vaidya, Vaibhav R. , Slusser, Joshua P. , Hodge, David O. , Ackerman, Michael J. , Asirvatham, Samuel J. , DeSimone, Christopher V. , Patel, Nikhil A. , DeSimone, Daniel C. , Rabinstein, Alejandro A. , Asirvatham, Samuel J

Circulation | August 15, 2013 | Volume: 128 | Issue: 13 | Pages: 1433-1441

10.1161/circulationaha.113.003540 Get It

Background— A patent foramen ovale (PFO) may permit arterial embolization of thrombi that accumulate on the leads of cardiac implantable electronic devices in the right-sided cardiac chambers. We sought to determine whether a PFO increases the risk of stroke/transient ischemic attack (TIA) in patients with endocardial leads. Methods and Results— We retrospectively evaluated all patients who had endocardial leads implanted between January 1, 2000, and October 25, 2010, at Mayo Clinic Rochester. Echocardiography was used to establish definite PFO and non-PFO cohorts. The primary end point of stroke/TIA consistent with a cardioembolic etiology and the secondary end point of mortality during postimplantation follow-up were compared in PFO versus non-PFO patients with the use of Cox proportional hazards models. We analyzed 6075 patients (364 with PFO) followed for a mean 4.7±3.1 years. The primary end point of stroke/TIA was met in 30/364 (8.2%) PFO versus 117/5711 (2.0%) non-PFO patients (hazard ratio, 3.49; 95% confidence interval, 2.33–5.25; P <0.0001). The association of PFO with stroke/TIA remained significant after multivariable adjustment for age, sex, history of stroke/TIA, atrial fibrillation, and baseline aspirin/warfarin use (hazard ratio, 3.30; 95% confidence interval, 2.19–4.96; P <0.0001). There was no significant difference in all-cause mortality between PFO and non-PFO patients (hazard ratio, 0.91; 95% confidence interval, 0.77–1.07; P =0.25). Conclusions— In patients with endocardial leads, the presence of a PFO on routine echocardiography is associated with a substantially increased risk of embolic stroke/TIA. This finding suggests a role of screening for PFOs in patients who require cardiac implantable electronic devices; if a PFO is detected, PFO closure, anticoagulation, or nonvascular lead placement may be considered.