Cha, Yong‐Mei

https://orcid.org/0000-0002-5897-9464

Mayo Clinic

Mayo Clinic

Citations 164

A Case Report of a Wenckebach Phenomenon Occurring during a His-Bundle Pacing Procedure: Is It Atrioventricular Node Pacing?
Ma, Chengming , Li, Wen-wen , Cha, Yong‐Mei , Xia, Yunlong , Gao, Lianjun , Dong, Yingxue, Li, Wenwen , Cha, Yongmei

Journal of Cardiovascular Development and Disease | July 19, 2022 | Volume: 9 | Issue: 7 | Pages: 231

10.3390/jcdd9070231 Get It

A 70-year-old man with severe valvular cardiomyopathy, permanent atrial fibrillation (AF) with a slow ventricular response, and transient atrioventricular (AV) block, was admitted to our center for severe heart failure and recurrent presyncope. While hospitalized, the coronary computed tomography angiography (CTA) showed huge atriums. We tried His bundle pacing (HBP). HB potential was observed at site A, and the His-ventricular (HV) interval was 68 ms. The duration from the stimulus signal to the onset of paced QRS (S-QRSonset) at site A was 232 ms when pacing at 60 beats per minute (BPM) with the pacing threshold of 2.0 V/0.5 ms. The S-QRSonset was longer than the HV interval and had a notable and progressive prolongation from 252 ms to 456 ms during the pacing at 90 BPM. Then, we pushed another lead a little forward, and the S-QRSonset shortened back to 68 ms, and the paced QRS morphology was the same as the intrinsic QRS morphology with the pacing threshold of 1.5 V/0.5 ms. The progressively prolonged S-QRSonset demonstrated a Wenckebach phenomenon (WP), a well-known electrophysiological characteristic of the AV node (AVN). It is the first time to report an intraoperative AVN-pacing related-WP in a patient with persistent AF. The enlarged atrium might be convenient for capturing the AVN. There are some other potential explanations for this phenomenon. The diameters of atriums decreased significantly, and the symptoms improved after the procedure. This is the first reported case in which we might achieve AVN capture in a patient with persistent AF. Although we ultimately chose HBP for better long-term pacing thresholds, the result of this case suggested that AVN pacing may be possible.
Implantable cardioverter defibrillators in patients with orthotopic heart transplant: A multicenter case series
Maskoun, Waddah , Raad, Mohamad , Cha, Yong‐Mei , Houmsse, Mahmoud , Abualsuod, Amjad , Ezzeddine, Fatima M. , Pieper, Justin, Jamoor, Khaled, Tita, Cristina , Miller, John M. , Ezzeddine, Fatima

Journal of Cardiovascular Electrophysiology | June 7, 2022 | Volume: 33 | Issue: 8 | Pages: 1813-1822

10.1111/jce.15588 Get It

AbstractBackgroundSudden cardiac death (SCD) is common after orthotopic heart transplant (OHT). No clear guidelines for implantable cardioverter defibrillator (ICD) implantation in OHT patients at high risk for SCD currently exist.ObjectivesTo assess the safety, efficacy, and benefit of ICDs and resynchronization therapy post‐OHT. We also provide a systematic review of previous reports.MethodsA retrospective multicenter cohort study within the United States. Patients with ICD post‐OHT between 2000 and 2020 were identified.ResultsWe analyzed 16 patients from 4 centers. The mean standard‐deviation (SD) age was 43 (18) years at OHT and 51 (20) years at ICD implantation. The mean (SD) duration from OHT to ICD implantation was 9 (5) years. The mean (SD) left ventricular ejection fraction (LVEF) was 35% (17%). There were 2 (13%) postprocedural complications: 1 hematoma and 1 death. Mean (SD) follow‐up was 24 (23) months. Survival rate was 63% (10/16) at 1 year and 56% (9/16) at 2 years, with 6/7 of those who died having LVEF < 35% at the time of the ICD implantation. Patients were more likely to receive appropriate therapy if their ICD was implanted for secondary (5/8) rather than primary (0/8) prevention (p = .007). Of those who did, 4 patients survived to 30 days post‐ICD therapy. Severe CAV was not associated with the rate of appropriate therapy.ConclusionsBeneficial outcomes were observed when ICDs were implanted for secondary prevention only, and in patients with higher baseline LVEF. We also observed benefits with resynchronization therapy.
One-year outcomes of catheter ablation for atrial fibrillation in young patients
Patel, Harsh , Patel, Kirtenkumar , Jaswaney, Rahul , Thakkar, Samarthkumar , Kowlgi, Narayan G., Arora, Shilpkumar , Mulpuru, Siva K. , Madhavan, Malini , Killu, Ammar M. , Cha, Yong‐Mei , Deshmukh, Abhishek , Tseng, Andrew S. , Kumar, Ashish , Jani, Chinmay , Kowlgi, Narayan G., Dani, Sourbha S. , DeSimone, Christopher V.

No container title available | May 18, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-1399820/v1 Get It

Abstract Background: Atrial fibrillation (AF) is relatively less frequent in younger patients (age<50). Recently, studies have suggested that early restoration of sinus rhythm may lead to improved outcomes compared with rate control. Methods: We included all hospitalized patients between 18 and 50 years with a diagnosis of AF from the Nationwide Readmission Database 2016-2017 from the Healthcare Cost and Utilization Project. Demographic and comorbidity data were collected and analyzed. Outcomes assessed included one-year AF readmission rates, all-cause readmission, ischemic stroke, and all-cause mortality. Subgroup analyses were performed for all demographic and comorbidity variables.Results: Overall, 52,598 patients (medium age 44, interquartile range 38-48, female 25.7%) were included in the study, including 2,146 (4.0%) who underwent catheter ablation for AF. Patients who underwent catheter ablation had a significantly lower rate of readmission for AF or any cause at one year (adjusted hazard ratios (HR) of 0.52 [95% confidence interval (CI): 0.43-0.63] and HR of 0.81 [95% CI: 0.72 - 0.89], respectively). There was no difference in 1-year readmission for stroke or all-cause mortality between the two groups. Subgroup analyses showed a consistent reduction in the risk of AF readmission among major demographic and comorbidity subgroups.Conclusion: Catheter ablation in young patients with AF was associated with a reduction in 1-year AF related and all-cause readmissions. These data merit further prospective investigation for validation.
Abstract 10726: Cardiac Resynchronization Therapy Response in Cardiac Sarcoidosis
Shabtaie, Samuel A. , Lee, Justin Z. , Cha, Yong‐Mei , Bois, John P. , Rosenbaum, Andrew , Siontis, Konstantinos C. , Mulpuru, Siva K. , Deshmukh, Abhishek , DeSimone, Christopher V. , Kapa, Suraj , AbouEzzeddine, Omar F.

Circulation | March 19, 2022 | Volume: 144 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.144.suppl_1.10726 Get It

Introduction: Cardiac Sarcoidosis (CS) is a non-ischemic cardiomyopathy (NICM) characterized by infiltration of non-caseating granulomas involving in the heart with highly variable clinical manifestations. Cardiac resynchronization therapy (CRT) has shown significant promise in NICM, though little is known about its effectiveness in patients with CS. Hypothesis: We sought to determine if CRT improved cardiac remodeling and reduced hospitalizations in patients with CS. Methods: We retrospectively reviewed all patients with a clinical or histological diagnosis of CS who underwent CRT implantation at a Mayo Clinic site from 2000-2021. Baseline characteristics, echocardiographic parameters, heart failure hospitalization, and major adverse cardiac events (MACE) were assessed. Results: Our cohort was comprised of 55 patients with 61.8% male and a mean age of 58.7 ± 10.9 years. At baseline, 38 (69.1%) patients had isolated CS, while 17 (30.9%) had evidence of CS with extra-cardiac sarcoidosis. The overwhelming majority underwent CRT-D implantation (n=52, 94.5%) with 67.3% of implanted devices upgrades from prior pacemaker or implantable cardioverter defibrillator. At 6 months post-implantation there was no significant different in ejection fraction (34.8 ± 10.9 % vs. 37.7 ± 14.2 %, p = 0.237), left ventricular end systolic diameter (49.1 ± 9.9 mm vs. 45.7 ± 9.9 mm, p = 0.077) or left ventricular end-diastolic diameter (58.5 ± 10.2 mm vs. 57.5 ± 8.1 mm, p = 0.574). Within the first 6 months post-implantation, 5 (9.1%) patients sustained a heart failure hospitalization. At a mean follow up of 4.1 ± 3.7 years, 14 (25.5%) patients experienced a heart failure hospitalization, 11 (20.0%) underwent cardiac transplantation, 1 (1.8%) underwent LVAD implantation and 7 (12.7%) patients died. Conclusions: Our findings suggest a poor response to CRT in patients with CS with no significant evidence of reverse remodeling within 6 months and a substantial proportion of patients progressing to advanced heart failure therapies.
A real‐world experience of atrioventricular synchronous pacing with leadless ventricular pacemakers
Kowlgi, Gurukripa N. , Tseng, Andrew S. , Tempel, Nathan D., Henrich, Mark, Venkatachalam, Kalpathi L., Scott, Luis R. , Shen, Win‐Kuang , Deshmukh, Abhishek , Madhavan, Malini , Lee, Hon‐Chi, Asirvatham, Samuel J. , Friedman, Paul A. , Cha, Yong‐Mei , Mulpuru, Siva K. , Henrich, Mark J, Deshmukh, Abhishek J , Tseng, A S , Asirvatham, Samuel J , Kowlgi, Narayan G

Journal of Cardiovascular Electrophysiology | March 2, 2022 | Volume: 33 | Issue: 5 | Pages: 982-993

10.1111/jce.15430 Get It

AbstractAimsThe MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer‐based atrial sensing. Data regarding the real‐world experience with this novel system are scarce. We sought to characterize patients undergoing MicraTM‐AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony.MethodsIn this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM‐AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow‐up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous ventricular pacing (AsVP) ≥ 70%.ResultsSixty‐five percent of patients achieved AsVP ≥ 70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure, and prior cardiac surgery. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were small A4‐wave amplitude, high ventricular pacing burden, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow‐up.ConclusionWith the increasing popularity of leadless pacemakers, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM‐AV devices.
A wearable cardioverter defibrillator with a low false alarm rate
Poole, Jeanne E. , Gleva, Marye J. , Birgersdotter‐Green, Ulrika , Branch, Kelley R. , Salam, Tariq , Crawford, Thomas , Willcox, Mark E. , Sridhar, Arun Mahankali, Mikdadi, Ghiath, Beinart, Sean C., Cha, Yong‐Mei , Russo, Andrea M. , Rowbotham, Ron, Sullivan, Joseph, Gustavson, Laura , Kivilaid, Kaisa, Salam, Tariq , Cha, Yong-Mei , Doshi, Rahul N.

Journal of Cardiovascular Electrophysiology | February 17, 2022 | Volume: 33 | Issue: 5 | Pages: 831-842

10.1111/jce.15417 Get It

AbstractIntroductionA wearable cardioverter defibrillator (WCD) is indicated in appropriate patients to reduce the risk for sudden cardiac death. Challenges for patients wearing a WCD have been frequent false shock alarms primarily due to electrocardiogram noise and wear discomfort. The objective of this study was to test a contemporary WCD designed for reduced false shock alarms and improved comfort.MethodsOne hundred and thirty patients with left ventricular ejection fraction ≤40% and an active implantable cardioverter defibrillator (ICD) were fitted with the ASSURE WCD (Kestra Medical Technologies) and followed for 30 days. WCD detection was enabled and shock alarm markers recorded, but shocks and shock alarms were disabled. All WCD episodes and ICD ventricular tachycardia/ventricular fibrillation (VT/VF) episodes were adjudicated. The primary endpoint was the false‐positive shock alarm rate with a performance goal of 1 every 3.4 days (0.29 per patient‐day).ResultsOf 163 WCD episodes, 4 were VT/VF and 159 non‐VT/VF (121 rhythms with noise, 32 uncertain with noise, 6 atrial flutter without noise). Only three false‐positive shock alarm markers were recorded; one false‐positive shock alarm every 1333 patient‐days (0.00075 per patient‐day, 95% confidence interval: 0.00015–0.00361; p < .001). No ICD recorded VT/VF episodes meeting WCD detection criteria (≥170 bpm for ≥20 s) were missed by the WCD during 3501 patient‐days of use. Median wear was 31.0 days (interquartile range [IQR] 2.0) and median daily use 23.0 h (IQR 1.7). Adverse events were mostly mild: skin irritation (19.4%) and musculoskeletal discomfort (8.5%).ConclusionThe ASSURE WCD demonstrated a low false‐positive shock alarm rate, low patient‐reported discomfort, and no serious adverse events.
Ventricular Arrhythmias Among Patients With Advanced Heart Failure: A Population‐Based Study
Tan, Nicholas Y. , Roger, Véronique L. , Killian, Jill M. , Cha, Yong‐Mei , Noseworthy, Peter A. , Dunlay, Shannon M. , Noseworthy, Peter A , Dunlay, Shannon

Journal of the American Heart Association | December 22, 2021 | Volume: 11 | Issue: 1 | Pages: No page available

10.1161/jaha.121.023377 Get It

Background The epidemiology of ventricular arrhythmias (VAs) in patients with advanced heart failure (HF) is not well defined. Methods and Results Residents of Olmsted County, Minnesota, with advanced HF from 2007 to 2017 were identified using the 2018 European Society of Cardiology criteria. Billing codes were used to capture VAs; severe VAs requiring emergency care were defined as events associated with emergency department visits or hospitalizations. The cumulative incidence of VAs postadvanced HF was estimated with the Kaplan–Meier method. Multivariable Cox analyses were used to determine the following: (1) Predictors of severe VAs postadvanced HF; and (2) Impact of severe VAs on mortality. Of 936 patients with advanced HF, 261 (27.9%) had a history of VA. The 1‐year cumulative incidence of severe VAs postadvanced HF was 5.4%. Prior VAs (hazard ratio [HR] 2.22 [95% CI, 1.26–3.89], P =0.006) and left ventricular ejection fraction <40% (HR, 3.79 [95% CI, 1.72–8.39], P <0.001) were independently associated with increased severe VA risk postadvanced HF. New‐onset severe VAs were associated with increased mortality (HR, 4.41 [95% CI, 2.80–6.94]; P <0.001), whereas severe VAs in patients with prior VAs had no significant association with mortality risk (HR, 1.08 [95% CI, 0.65–1.78]; P =0.77). Severe VAs were associated with increased mortality in patients without implantable cardioverter defibrillators (HR, 4.89 [95% CI, 2.89–8.26]; P <0.001), but not in patients with implantable cardioverter defibrillators (HR, 1.42 [95% CI, 0.92–2.19]; P =0.11). Conclusions Patients with left ventricular ejection fraction <40% and prior VAs have increased risk of severe VA postadvanced HF. New‐onset severe VAs or severe VAs without implantable cardioverter defibrillators postadvanced HF are associated with increased mortality.
Characteristics and outcomes of ventricular tachycardia and premature ventricular contractions ablation in patients with prior mitral valve surgery
Khalil, Fouad , Madhavan, Malini , Ahmad, Ali , Mulpuru, Siva K. , Siontis, Konstantinos C. , Deshmukh, Abhishek , Cha, Yong‐Mei , Friedman, Paul A. , Munger, Thomas M. , Asirvatham, Samuel J. , Killu, Ammar M. , Madhavan, Malini , Kapa, Suraj , Mulpuru, Siva K , Siontis, Konstantinos C , Deshmukh, Abhishek J , Friedman, Paul A , Munger, Thomas, Asirvatham, Samuel J , Killu, Ammar M , Khalil, Fouad , Toya, Takumi , Badawy, Mohamed, Kapa, Suraj , DeSimone, Christopher V.

Journal of Cardiovascular Electrophysiology | December 15, 2021 | Volume: 33 | Issue: 2 | Pages: 274-283

10.1111/jce.15331 Get It

AbstractBackgroundData regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation following mitral valve surgery (MVS) is limited. Catheter ablation (CA) can be challenging given perivalvular substrate in the setting of mitral annuloplasty or prosthetic valves.ObjectiveTo investigate the characteristics, safety, and outcomes of radiofrequency CA in patients with prior MVS and ventricular arrhythmias (VA).MethodsWe identified consecutive patients with prior MVS who underwent CA for VT or PVC between January 2013 and December 2018. We investigated the mechanism of arrhythmia, ablation approach, peri‐operative complications, and outcomes.ResultsIn our cohort, 31 patients (77% men, mean age 62.3 ± 10.8 years, left ventricular ejection fraction 39.2 ± 13.9%) with prior MVS underwent CA (16 VT; 15 PVC). Access to the left ventricle was via transseptal approach in 17 patients, and a retrograde aortic approach was used in 13 patients. A combined transseptal and retrograde aortic approach was used in one patient, and a percutaneous epicardial approach was combined with trans‐septal approach in one patient. Heterogenous scar regions were present in 94% of VT patients and scar‐related reentry was the dominant mechanism of VT. Forty‐seven percent of PVC patients had abnormal substrate at the site targeted for ablation. Clinical VA substrates involved the peri‐mitral area in six patients with VT and five patients with PVC ablation. No procedure‐related complications were reported. The overall recurrence‐free rate at 1‐year was 72.2%; 67% in the VT group and 78% in the PVC group. No arrhythmia‐related death was documented on long‐term follow‐up.ConclusionCA of VAs can be performed safely and effectively in patients with MVS.
A Real-world Experience of Atrioventricular Synchronous Pacing with Leadless Ventricular Pacemakers
Kowlgi, Gurukripa N. , Tempel, Nathan D., Henrich, Mark, Venkatachalam, Kalpathi L., Scott, Luis R. , Shen, Win‐Kuang , Deshmukh, Abhishek , Madhavan, Malini , Lee, Hon-Chi , Friedman, Paul A. , Cha, Yong‐Mei , Mulpuru, Siva K. , Kowlgi, Narayan G , Tseng, Andrew S. , Asirvatham, Samuel J.

No container title available | November 16, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.163711930.05423871/v1 Get It

Aims: The MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer-based atrial sensing. Data regarding the real-world experience with this novel system are currently lacking. We sought to characterize patients undergoing MicraTM -AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony. Methods: In this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM -AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow-up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous-ventricular pacing (AsVP) ≥70%. Results: Fifty-six percent of patients achieved AsVP ≥70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure and pulmonary hypertension. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were persistent atrial arrhythmias, small A4-wave amplitude, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow-up. Conclusion: With the increasing popularity of leadless PM, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM -AV devices.
Catheter ablation of ventricular tachycardia in patients with postinfarction left ventricular aneurysm
Amin, Mustapha, Hilaire, Emilie, Siontis, Konstantinos C. , Madhavan, Malini , Mulpuru, Siva K. , Deshmukh, Abhishek , Cha, Yong‐Mei , Friedman, Paul A. , Munger, Thomas M. , Asirvatham, Samuel J. , Killu, Ammar M. , Farwati, Medhat , Siontis, Konstantinos C , Madhavan, Malini , Kapa, Suraj , Mulpuru, Siva K , Deshmukh, Abhishek J , Cha, Yong-Mei , Friedman, Paul A , Munger, Thomas, Asirvatham, Samuel J , Killu, Ammar M , Kapa, Suraj

Journal of Cardiovascular Electrophysiology | October 20, 2021 | Volume: 32 | Issue: 12 | Pages: 3156-3164

10.1111/jce.15273 Get It

AbstractBackgroundWhile ventricular tachycardia (VT) in the setting of postmyocardial infarction left ventricular aneurysms (LVA) is not uncommonly encountered, there is a scarcity of data regarding the safety, efficacy, and outcomes of ablation of VT in this subset of patients.MethodsOur study included consecutive patients aged 18 years or older with postmyocardial infarction LVA who presented to Mayo Clinic for catheter ablation of VT between 2002 and 2018.ResultsOf 34 patients, the mean age was 70.4 ± 9.1 years; 91% were male. Mean LVEF was 29 ± 9.7% and left ventricular end‐diastolic dimension was 64.9 ± 6.6 mm. The site of the LVA was apical in 21 patients (62%). Fifteen patients (44%) presented with electrical storm or incessant VT. Nine patients (26%) had a history of intracardiac thrombus. All except for one patient had at least one VT originating from the aneurysm. The mean number of VTs was 2.9 ± 1.7. All patients underwent ablation at the site of the aneurysm. Ablation outside the aneurysm was performed in 13 patients (38%). Low‐voltage fractionated potentials and/or late potentials at the aneurysmal site were present in all cases. Complete elimination of all VTs was achieved in 18 (53%), while the elimination of the clinical VT with continued inducibility of nonclinical VTs was achieved in a further 11 patients (32%). Two patients developed cardiac tamponade requiring pericardiocentesis. During a mean follow‐up period of 2.3 ± 2.4 years, 11 patients (32%) experienced VT recurrence. Freedom from all‐cause mortality at 1‐year follow‐up was 94%.ConclusionRadiofrequency catheter ablation targeting the aneurysmal site is a feasible and reasonably effective management strategy for clinical VTs in patients with postinfarction LVA.