Back to Authors

Law, Ian H.

https://orcid.org/0000-0001-7309-6005

Mayo Clinic

University of Iowa

Citations 12

Multi-Institutional Study of Implantable Defibrillator Lead Performance in Children and Young Adults
Atallah, Joseph , Erickson, Christopher C. , Cecchin, Frank , Dubin, Anne M. , Law, Ian H. , Cohen, Mitchell I. , Cannon, Bryan C. , Freedenberg, Vicki , Gierdalski, Marcin , Berul, Charles I. , LaPage, Martin J , Chun, Terrence , Atallah, Joseph , Dubin, Anne M , Law, Ian H

Circulation | May 21, 2013 | Volume: 127 | Issue: 24 | Pages: 2393-2402

10.1161/circulationaha.112.001120 Get It

Background— Implantable cardioverter-defibrillator (ICD) therapy in children and congenital heart disease patients is hampered by poor long-term lead survival. Lead extraction is technically difficult and carries substantial morbidity. We sought to determine the outcomes of ICD leads in pediatric and congenital heart disease patients. Methods and Results— The Pediatric Lead Extractability and Survival Evaluation (PLEASE) is a 24-center international registry. Pediatric and congenital heart disease patients with ICD lead implantations from 2005 to 2010 were eligible. Study subjects comprised 878 ICD patients (44% congenital heart disease). Mean±SD age at implantation was 18.6±9.8 years. Of the 965 total leads, 54% were thin (≤7F), of which 57% were Fidelis, and 23% were coated with expanded polytetrafluoroethylene. There were 139 ICD lead failures (14%) in 132 patients (15%) at a mean lead age of 2.0±1.4 years, causing shocks in 53 patients (40%). Independent predictors of lead failure included younger implantation age and Fidelis leads. Actuarial analysis showed an incremental risk of lead failure with younger age at implantation: <8 years compared with >18 years ( P =0.015). The actuarial yearly failure rate was 2.3% for non-Fidelis and 9.1% for Fidelis leads. Extraction was performed on 143 leads (80% thin, 7% expanded polytetrafluoroethylene coated), with lead age as the only independent predictor for advanced extraction techniques. There were 6 major extraction complications (4%) but no procedural mortality. Conclusions— This study demonstrates that ICD leads in children and congenital heart disease patients have an age-related suboptimal performance, further compounded by a high failure rate of Fidelis leads. Advanced extraction techniques were common and correlated with older lead age. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00335036.
Safety of Sports for Athletes With Implantable Cardioverter-Defibrillators
Lampert, Rachel , Olshansky, Brian , Heidbüchel, Hein , Lawless, Christine E., Saarel, Elizabeth V. , Ackerman, Michael J. , Calkins, Hugh , Maron, Barry J. , Scheinman, Melvin M. , Wilkoff, Bruce L. , Zipes, Douglas P. , Berul, Charles I. , Cheng, Alan , Law, Ian H. , Loomis, Michele, Barth, Cheryl , Dziura, James , Cannom, David S. , Estes, N.A. Mark , Link, Mark S. , Marcus, Gregory M. , Brandt, Cynthia , Li, Fangyong , Olshansky, Brian , Law, Ian H , Zipes, Douglas P

Circulation | May 20, 2013 | Volume: 127 | Issue: 20 | Pages: 2021-2030

10.1161/circulationaha.112.000447 Get It

Background— The risks of sports participation for implantable cardioverter-defibrillator (ICD) patients are unknown. Methods and Results— Athletes with ICDs (age, 10–60 years) participating in organized (n=328) or high-risk (n=44) sports were recruited. Sports-related and clinical data were obtained by phone interview and medical records. Follow-up occurred every 6 months. ICD shock data and clinical outcomes were adjudicated by 2 electrophysiologists. Median age was 33 years (89 subjects <20 years of age); 33% were female. Sixty were competitive athletes (varsity/junior varsity/traveling team). A pre-ICD history of ventricular arrhythmia was present in 42%. Running, basketball, and soccer were the most common sports. Over a median 31-month (interquartile range, 21–46 months) follow-up, there were no occurrences of either primary end point—death or resuscitated arrest or arrhythmia- or shock-related injury—during sports. There were 49 shocks in 37 participants (10% of study population) during competition/practice, 39 shocks in 29 participants (8%) during other physical activity, and 33 shocks in 24 participants (6%) at rest. In 8 ventricular arrhythmia episodes (device defined), multiple shocks were received: 1 at rest, 4 during competition/practice, and 3 during other physical activity. Ultimately, the ICD terminated all episodes. Freedom from lead malfunction was 97% at 5 years (from implantation) and 90% at 10 years. Conclusions— Many athletes with ICDs can engage in vigorous and competitive sports without physical injury or failure to terminate the arrhythmia despite the occurrence of both inappropriate and appropriate shocks. These data provide a basis for more informed physician and patient decision making in terms of sports participation for athletes with ICDs.