Inhibition of 11β‐Hydroxysteroid dehydrogenase‐1 with
AZD4017
in patients with nonalcoholic steatohepatitis or nonalcoholic fatty liver disease: A randomized, double‐blind, placebo‐controlled, phase
Abstract Aim To evaluate whether short‐term treatment with a selective 11β‐Hydroxysteroid dehydrogenase‐1 (11β‐HSD1) inhibitor, AZD4017, would block hepatic cortisol production and thereby decrease hepatic fat in patients with nonalcoholic fatty liver disease (NAFLD)/nonalcoholic steatohepatitis (NASH), with or without type 2 diabetes (T2D). Materials and Methods This was a randomized, double‐blind, placebo‐controlled, phase 2 study conducted at two sites. Key inclusion criteria were the presence of NAFLD or NASH on magnetic resonance imaging (MRI) or recent biopsy positive for NASH. Enrolled patients were randomly assigned (1:1) to AZD4017 or placebo for 12 weeks. Primary outcomes were between‐group differences in mean change from baseline to week 12 in liver fat fraction (LFF) and conversion of 13 C cortisone to 13 C cortisol in the liver. Results A total of 93 patients were randomized; 85 patients completed treatment. The mean (standard deviation [SD]) change in LFF was −0.667 (5.246) and 0.139 (4.323) in the AZD4017 and placebo groups ( P = 0.441). For patients with NASH and T2D, the mean (SD) change in LFF was significantly improved in the AZD4017 versus the placebo group (−1.087 [5.374] vs. 1.675 [3.318]; P = 0.033). Conversion of 13 C cortisone to 13 C cortisol was blocked in all patients in the AZD4017 group. There were no significant between‐group differences (AZD4017 vs. placebo) in changes in fibrosis, weight, levels of liver enzymes or lipids, or insulin sensitivity. Conclusion Although the study did not meet one of the primary outcomes, AZD4017 blocked the conversion of 13 C cortisone to 13 C cortisol in the liver in all patients who received the drug. In patients with NASH and T2D, AZD4017 improved liver steatosis versus placebo.
Coronavirus Disease 2019 Vaccine-Breakthrough Infections Requiring Hospitalization in Mayo Clinic Florida Through August 2021
Abstract We characterized coronavirus disease 2019 (COVID-19) breakthrough cases admitted to a single center in Florida. With the emergence of delta variant, an increased number of hospitalizations was seen due to breakthrough infections. These patients were older and more likely to have comorbidities. Preventive measures should be maintained even after vaccination.
A Pilot Study to Estimate the Impact of High Matrix Image Reconstruction on Chest Computed Tomography
Objectives: The objectives of the study were to estimate the impact of high matrix image reconstruction on chest computed tomography (CT) compared to standard image reconstruction. Material and Methods: This retrospective study included patients with interstitial or parenchymal lung disease, airway disease, and pulmonary nodules who underwent chest CT. Chest CT images were reconstructed using high matrix (1024 × 1024) or standard matrix (512 × 512), with all other parameters matched. Two radiologists, blinded to reconstruction technique, independently examined each lung, viewing image sets side by side and rating the conspicuity of imaging findings using a 5-point relative conspicuity scale. The presence of pulmonary nodules and confidence in classification of internal attenuation was also graded. Overall image quality and subjective noise/artifacts were assessed. Results: Thirty-four patients with 68 lungs were evaluated. Relative conspicuity scores were significantly higher using high matrix image reconstruction for all imaging findings indicative of idiopathic lung fibrosis (peripheral airway visualization, interlobular septal thickening, intralobular reticular opacity, and end-stage fibrotic change; P ≤ 0.001) along with emphysema, mosaic attenuation, and fourth order bronchi for both readers (P ≤ 0.001). High matrix reconstruction did not improve confidence in the presence or classification of internal nodule attenuation for either reader. Overall image quality was increased but not subjective noise/artifacts with high matrix image reconstruction for both readers (P < 0.001). Conclusion: High matrix image reconstruction significantly improves the conspicuity of imaging findings reflecting interstitial lung disease and may be useful for diagnosis or treatment response assessment.
Variable differences of nerve conduction amplitudes versus velocities and distal latencies of healthy subjects assessed in ethnic cohorts
Abstract Variable differences of nerve conduction amplitudes vs velocities and distal latencies (DLs) of healthy subjects assessed in ethnic cohorts. Introduction/Aims The variables affecting reference compound muscle (CMAP) and sensory nerve action potential (SNAP) amplitudes as compared to ones affecting conduction velocities and DLs have not been adequately evaluated in previous studies. In this report, this subject is studied in healthy subject cohorts mainly of Northern European extraction, Northern Plains Indians, and Latinos. Methods Nineteen variables and 18 attributes of nerve conductions (NCs) were assessed using highly standard testing conditions and techniques. Classification and Regression Tree analyses were used to assess variable differences among amplitudes, conduction velocities, and DLs. Results The most important variable affecting CMAP and SNAP amplitudes was age. For conduction velocities (CVs) and DLs, the variables were height, ethnic cohort, and age. Discussion The variables affecting attributes of NCs were similar for the three ethnic cohorts evaluated. The differences of variables affecting amplitudes compared to CVs and DLs need to be taken into account in interpretation of NC results and in setting reference limits for use in medical practice, epidemiology surveys, and therapeutic trials. Scores of CMAP and SNAP amplitudes are suitable measures of sensorimotor polyneuropathy severity, whereas conduction velocities and DLs reflect physiologic/pathologic abnormality of nerve fibers.
Detecting cardiomyopathies in pregnancy and the postpartum period with an electrocardiogram-based deep learning model
Abstract Aims Cardiovascular disease is a major threat to maternal health, with cardiomyopathy being among the most common acquired cardiovascular diseases during pregnancy and the postpartum period. The aim of our study was to evaluate the effectiveness of an electrocardiogram (ECG)-based deep learning model in identifying cardiomyopathy during pregnancy and the postpartum period. Methods and results We used an ECG-based deep learning model to detect cardiomyopathy in a cohort of women who were pregnant or in the postpartum period seen at Mayo Clinic. Model performance was evaluated using the area under the receiver operating characteristic curve (AUC), accuracy, sensitivity, and specificity. We compared the diagnostic probabilities of the deep learning model with natriuretic peptides and a multivariable model consisting of demographic and clinical parameters. The study cohort included 1807 women; 7%, 10%, and 13% had left ventricular ejection fraction (LVEF) of 35% or less, <45%, and <50%, respectively. The ECG-based deep learning model identified cardiomyopathy with AUCs of 0.92 (LVEF ≤ 35%), 0.89 (LVEF < 45%), and 0.87 (LVEF < 50%). For LVEF of 35% or less, AUC was higher in Black (0.95) and Hispanic (0.98) women compared to White (0.91). Natriuretic peptides and the multivariable model had AUCs of 0.85 to 0.86 and 0.72, respectively. Conclusions An ECG-based deep learning model effectively identifies cardiomyopathy during pregnancy and the postpartum period and outperforms natriuretic peptides and traditional clinical parameters with the potential to become a powerful initial screening tool for cardiomyopathy in the obstetric care setting.
SARS-CoV-2 Serologic Assays Dependent on Dual-Antigen Binding Demonstrate Diverging Kinetics Relative to Other Antibody Detection Methods
Longitudinal studies assessing durability of the anti-severe acute respiratory syndrome coronavirus 2 (anti-SARS-CoV-2) humoral immune response have generated conflicting results. This has been proposed to be due to differences in patient populations, the lack of standardized methodologies, and the use of assays that measure distinct aspects of the humoral response.
Directed stimulation of the dentato-rubro-thalamic tract for deep brain stimulation in essential tremor: a blinded clinical trial
Objective Observational studies utilising diffusion tractography have suggested a common mechanism for tremor alleviation in deep brain stimulation for essential tremor: the decussating portion of the dentato-rubro-thalamic tract. We hypothesised that directional stimulation of the dentato-rubro-thalamic tract would result in greater tremor improvement compared to sham programming, as well as comparable improvement as more tedious standard-of-care programming. Methods A prospective, blinded crossover trial was performed to assess the feasibility, safety and outcomes of programming based solely on dentato-rubro-thalamic tract anatomy. Using magnetic resonance imaging diffusion-tractography, the dentato-rubro-thalamic tract was identified and a connectivity-based treatment setting was derived by modelling a volume of tissue activated using directional current steering oriented towards the dentato-rubro-thalamic tract centre. A sham setting was created at approximately 180° opposite the connectivity-based treatment. Standard-of-care programming at 3 months was compared to connectivity-based treatment and sham settings that were blinded to the programmer. The primary outcome measure was percentage improvement in the Fahn–Tolosa–Marín tremor rating score compared to the preoperative baseline. Results Among the six patients, tremor rating scores differed significantly among the three experimental conditions ( P=0.030). The mean tremor rating score improvement was greater with the connectivity-based treatment settings (64.6% ± 14.3%) than with sham (44.8% ± 18.6%; P=0.031) and standard-of-care programming (50.7% ± 19.2%; P=0.062). The distance between the centre of the dentato-rubro-thalamic tract and the volume of tissue activated inversely correlated with the percentage improvement in the tremor rating score (R 2 =0.24; P=0.04). No significant adverse events were encountered. Conclusions Using a blinded, crossover trial design, we have shown the technical feasibility, safety and potential efficacy of connectivity-based stimulation settings in deep brain stimulation for treatment of essential tremor.
Abstract The aim of the European Heart Journal (EHJ) is to attract innovative, methodologically sound, and clinically relevant research manuscripts able to change clinical practice and/or substantially advance knowledge on cardiovascular diseases. As the reference journal in cardiovascular medicine, the EHJ is committed to publishing only the best cardiovascular science adhering to the highest ethical principles. EHJ uses highly rigorous peer-review, critical statistical review and the highest quality editorial process, to ensure the novelty, accuracy, quality, and relevance of all accepted manuscripts with the aim of inspiring the clinical practice of EHJ readers and reducing the global burden of cardiovascular diseases. This review article summarizes the quality standards pursued by the EHJ to fulfill its mission.
Convalescent plasma use in the USA was inversely correlated with COVID-19 mortality
Background: The US Food and Drug Administration authorized COVID-19 convalescent plasma (CCP) therapy for hospitalized COVID-19 patients via the Expanded Access Program (EAP) and the Emergency Use Authorization (EUA), leading to use in about 500,000 patients during the first year of the pandemic for the USA. Methods: We tracked the number of CCP units dispensed to hospitals by blood banking organizations and correlated that usage with hospital admission and mortality data. Results: CCP usage per admission peaked in Fall 2020, with more than 40% of inpatients estimated to have received CCP between late September and early November 2020. However, after randomized controlled trials failed to show a reduction in mortality, CCP usage per admission declined steadily to a nadir of less than 10% in March 2021. We found a strong inverse correlation (r = −0.52, p=0.002) between CCP usage per hospital admission and deaths occurring 2 weeks after admission, and this finding was robust to examination of deaths taking place 1, 2, or 3 weeks after admission. Changes in the number of hospital admissions, SARS-CoV-2 variants, and age of patients could not explain these findings. The retreat from CCP usage might have resulted in as many as 29,000 excess deaths from mid-November 2020 to February 2021. Conclusions: A strong inverse correlation between CCP use and mortality per admission in the USA provides population-level evidence consistent with the notion that CCP reduces mortality in COVID-19 and suggests that the recent decline in usage could have resulted in excess deaths. Funding: There was no specific funding for this study. AC was supported in part by RO1 HL059842 and R01 AI1520789; MJJ was supported in part by 5R35HL139854. This project has been funded in whole or in part with Federal funds from the Department of Health and Human Services; Office of the Assistant Secretary for Preparedness and Response; Biomedical Advanced Research and Development Authority under Contract No. 75A50120C00096.
Wearable electronic devices for chronic pain intensity assessment: A systematic review
AbstractWearable electronic devices are a convenient solution to pain intensity assessment as they can provide continuous monitoring for more precise medication adjustments. However, there is little evidence regarding the use of wearable electronic devices for chronic pain intensity assessment. Our primary objective was to examine the physiologic parameters used by wearable electronic devices for chronic pain intensity assessment. We initially inquired PubMed, CINAHL, and Embase for studies evaluating the use of wearable electronic devices for chronic pain intensity assessment. We updated our inquiry by searching on PubMed, Embase, Scopus, and Google Scholar. English peer‐reviewed studies were included, with no exclusions based on time frame or publication status. Of 348 articles that were identified on the first inquiry, 8 fulfilled the eligibility criteria. Of 179 articles that were identified on the last inquiry, only 1 fulfilled the eligibility criteria. We found articles evaluating wristbands, smartwatches, and belts. Parameters evaluated were psychomotor and sleep patterns, space and time mobility, heart rate variability, and skeletal muscle electrical activity. Most of the studies found significant positive associations between physiological parameters measured by wearable electronic devices and self‐reporting pain scales. Wearable electronic devices reliably reflect physiologic or biometric parameters, providing a physiological correlation for pain. Early stage investigation suggests that the degree of pain intensity can be discerned, which ideally will reduce the bias inherent to existing numeric/verbal scales. Further research on the use of these devices is vital.