Background Coronary microvascular function and hemodynamics may play a role in coronary circulation and myocardial remodeling in patients with aortic stenosis (AS). We aimed to evaluate the relationship between myocardial blood flow and myocardial function in patients with AS, no AS, and aortic valve sclerosis. Methods and Results We included consecutive patients who had resting transthoracic echocardiography and clinically indicated positron emission tomography myocardial perfusion imaging to capture their left ventricular ejection fraction, global longitudinal strain (GLS), and myocardial flow reserve (MFR). The primary outcome was major adverse cardiovascular event (all‐cause mortality, myocardial infarction, or late revascularization). There were 2778 patients (208 with aortic sclerosis, 39 with prosthetic aortic valve, 2406 with no AS, and 54, 49, and 22 with mild, moderate, and severe AS, respectively). Increasing AS severity was associated with impaired MFR ( P <0.001) and GLS ( P <0.001), even when perfusion was normal. Statistically significant associations were noted between MFR and GLS, MFR and left ventricular ejection fraction, and MFR and left ventricular ejection fraction reserve. After a median follow‐up of 349 (interquartile range, 116–662) days, 4 (7.4%), 5 (10.2%), and 6 (27.3%) patients experienced a major adverse cardiovascular event in the mild, moderate, and severe AS groups, respectively. In a matched‐control analysis, patients with mild‐to‐moderate AS had higher rates of impaired MFR (52.9% versus 39.9%; P =0.048) and major adverse cardiovascular event (11.8% versus 3.0%; P =0.002). Conclusions Despite lack of ischemia, as severity of AS increased, MFR decreased and GLS worsened, reflecting worse coronary microvascular health and myocardial remodeling. Positron emission tomography–derived MFR showed a significant independent correlation with left ventricular ejection fraction and GLS. Patients with prosthetic aortic valve showed a high prevalence of impaired MFR.
Association of Bovine Arch Anatomy With Incident Stroke After Transcatheter Aortic Valve Replacement
Background Acute ischemic stroke complicates 2% to 3% of transcatheter aortic valve replacements (TAVRs). This study aimed to identify the aortic anatomic correlates in patients after TAVR stroke. Methods and Results This is a single‐center, retrospective study of patients who underwent TAVR at the Mayo Clinic between 2012 and 2022. The aortic arch morphology was determined via a manual review of the pre‐TAVR computed tomography images. An “a priori” approach was used to select the covariates for the following: (1) the logistic regression model assessing the association between a bovine arch and periprocedural stroke (defined as stroke within 7 days after TAVR); and (2) the Cox proportional hazards regression model assessing the association between a bovine arch and long‐term stroke after TAVR. A total of 2775 patients were included (59.6% men; 97.8% White race; mean±SD age, 79.3±8.4 years), of whom 495 (17.8%) had a bovine arch morphology. Fifty‐seven patients (1.7%) experienced a periprocedural stroke. The incidence of acute stroke was significantly higher among patients with a bovine arch compared with those with a nonbovine arch (3.6% versus 1.7%; P =0.01). After adjustment, a bovine arch was independently associated with increased periprocedural strokes (adjusted odds ratio, 2.16 [95% CI, 1.22–3.83]). At a median follow‐up of 2.7 years, the overall incidence of post‐TAVR stroke was 6.0% and was significantly higher in patients with a bovine arch even after adjusting for potential confounders (10.5% versus 5.0%; adjusted hazard ratio, 2.11 [95% CI, 1.51–2.93]; P <0.001). Conclusions A bovine arch anatomy is associated with a significantly higher risk of periprocedural and long‐term stroke after TAVR.
Machine learning facilitates the prediction of long-term mortality in patients with tricuspid regurgitation
Objective Tricuspid regurgitation (TR) is a prevalent valve disease associated with significant morbidity and mortality. We aimed to apply machine learning (ML) to assess risk stratification in patients with ≥moderate TR. Methods Patients with ≥moderate TR on echocardiogram between January 2005 and December 2016 were retrospectively included. We used 70% of data to train ML-based survival models including 27 clinical and echocardiographic features to predict mortality over a 3-year period on an independent test set (30%). To account for differences in baseline comorbidities, prediction was performed in groups stratified by increasing Charlson Comorbidity Index (CCI). Permutation feature importance was calculated using the best-performing model separately in these groups. Results Of 13 312 patients, mean age 72 ± 13 years and 7406 (55%) women, 7409 (56%) had moderate, 2646 (20%) had moderate–severe and 3257 (24%) had severe TR. The overall performance for 1-year mortality by 3 ML models was good, c-statistic 0.74–0.75. Interestingly, performance varied between CCI groups, (c-statistic = 0.774 in lowest CCI group and 0.661 in highest CCI group). The performance decreased over 3-year follow-up (average c-index 0.78). Furthermore, the top 10 features contributing to these predictions varied slightly with the CCI group, the top features included heart rate, right ventricular systolic pressure, blood pressure, diuretic use and age. Conclusions Machine learning of common clinical and echocardiographic features can evaluate mortality risk in patients with TR. Further refinement of models and validation in prospective studies are needed before incorporation into the clinical practice.
Prognostic Value of Patient‐Reported Outcomes in Predicting Long‐Term Mortality After Transcatheter Aortic Valve Replacement
Background Patient‐reported outcome measures have been shown to have important prognostic value after various cardiac interventions. We assessed the association between the change in Kansas City Cardiomyopathy Questionnaire 12 (KCCQ‐12) score after transcatheter aortic valve replacement and mortality. Methods and Results We included patients who underwent transcatheter aortic valve replacement at Mayo Clinic between February 2012 to June 2022 and who completed a KCCQ‐12 before and 30 to 45 days after the procedure. Patients were categorized into 3 groups: those who experienced significant (>+19 points; group 1), modest (1–19 points; group 2), and no (≤0 points; group 3) improvement. A total of 1124 patients were included: 60.8% men; 97.6% White. Mean age was 79.4±8.3 years, baseline KCCQ‐12 score was 53.9±24.5, and median Society of Thoracic Surgeons score was 4.9% (interquartile range, 3.1–8.0). At 45 days, the mean change in KCCQ‐12 score was 19±24 points; 46.3% (n=520) of patients had a significant improvement in their KCCQ‐12 score, while 33.4% (n=375) and 20.4% (n=229) had modest and no improvement, respectively. Median survival was higher in group 1 (5.7±0.2 years) compared with groups 2 and 3 (5.1±0.3 and 4.1±0.4 years, respectively; P <0.001). Compared with patients in group 1, those in groups 2 and 3 had higher long‐term risk‐adjusted mortality (adjusted hazard ratios, 1.54 [95% CI, 1.20–1.96], and 2.30 [95% CI, 1.74–3.04], respectively). Conclusions Patients who experience modest or no improvement in KCCQ‐12 score after transcatheter aortic valve replacement have substantially higher long‐term mortality. Delta KCCQ‐12 is a cost‐effective, efficient tool that can identify patients at increased risk of death at long‐term follow‐up post‐transcatheter aortic valve replacement.
Augmented Reality and Ultrasound-Guided Vascular Access
Background Transcatheter closure of patent foramen ovale (PFO) has reduced the risk of recurrent stroke in patients with cryptogenic strokes in randomized clinical trials. Whether PFO closure in clinical practice is associated with similar benefit remains unknown. Methods and Results We identified patients with PFO and a history of ischemic stroke or transient ischemic attack who were treated with PFO closure or medical therapy in the OptumLabs database. The primary end point was recurrent ischemic stroke or systemic embolization. Secondary outcomes included mortality, all stroke, transient ischemic attack, and major bleeding. A total of 6668 propensity‐matched patients were included (PFO closure n=4111; medical therapy n=2557). The incidence of stroke or systemic embolization per 100 person‐years was 2.38 after PFO cohort and 2.99 with medical therapy (hazard ratio [HR], 0.85 [95% CI, 0.68–1.05], P =0.13). Mortality was lower in the PFO closure cohort (1.78 versus 2.59 per 100 person‐years: HR, 0.69 [95% CI, 0.55–0.87], P =0.002). Falsification end points showed that this difference is unlikely to be completely explained by residual confounders. There were no significant differences between the groups in secondary end points including intracranial hemorrhage and major bleeding except for an increase in nonintracranial hemorrhage bleeding among patients treated with oral anticoagulation (1.42 versus 2.16 per 100 person‐years: HR, 0.69 [95% CI, 0.48–0.99], P =0.043). The main end point was consistent in subanalyses including patients <60 years of age, patients with prior stroke, and those treated after the publication of the positive PFO trials in 2017. Conclusions In contemporary US practice, PFO closure is not associated with lower rates of recurrent ischemic stroke or systemic embolization compared with medical therapy. Potential reasons for this discrepancy warrant further investigation.
Racial and Ethnic Disparities in the Use and Outcomes of Transcatheter Mitral Valve Replacement: Analysis From the National Inpatient Sample Database
Background Racial and ethnic disparities in outcomes exist following many cardiac procedures. Transcatheter mitral valve replacement (TMVR) has grown as an alternative to mitral valve surgery for patients at high surgical risk. The outcomes of TMVR by race and ethnicity are unknown. We aimed to evaluate racial and ethnic disparities in the outcomes of TMVR. Methods and Results We analyzed the National Inpatient Sample database from 2016 to 2020 to identify hospitalizations for TMVR. Racial and ethnic disparities in TMVR outcomes were determined using logistic regression models. Between 2016 and 2020, 5005 hospitalizations for TMVR were identified, composed of 3840 (76.7%) White race, 505 (10.1%) Black race, 315 (6.3%) Hispanic ethnicity, and 345 (6.9%) from other races (Asian, Pacific Islander, American Indian or Alaska Native, Other). Compared with other racial and ethnic groups, Black patients were significantly younger and more likely to be women (both P <0.01). There were no significant differences between White, Black, and Hispanic patients in in‐hospital mortality (5.2% versus 5.0% versus <3.5%; P =0.89) and procedural complications, including heart block ( P =0.91), permanent pacemaker ( P =0.49), prosthetic valve dysfunction ( P =0.45), stroke ( P =0.37), acute kidney injury ( P =0.32), major bleeding ( P =0.23), and blood transfusion ( P =0.92), even after adjustment for baseline characteristics. Adjusted vascular complications were higher in Black compared with White patients ( P =0.03). Trend analysis revealed a significant increase in TMVR in all racial and ethnic groups from 2016 to 2020 ( P trend <0.05). Conclusions Between 2016 and 2020, Black and Hispanic patients undergoing TMVR had similar in‐hospital outcomes compared with White patients, except for higher vascular complications in Black patients. Further comparative studies of TMVR in clinically similar White patients and other racial and ethnic groups are warranted to confirm our findings.
Racial, Ethnic, and Socioeconomic Inequities in Access to Left Atrial Appendage Occlusion
Background Inequitable access to high‐technology therapeutics may perpetuate inequities in care. We examined the characteristics of US hospitals that did and did not establish left atrial appendage occlusion (LAAO) programs, the patient populations those hospitals served, and the associations between zip code–level racial, ethnic, and socioeconomic composition and rates of LAAO among Medicare beneficiaries living within large metropolitan areas with LAAO programs. Methods and Results We conducted cross‐sectional analyses of Medicare fee‐for‐service claims for beneficiaries aged 66 years or older between 2016 and 2019. We identified hospitals establishing LAAO programs during the study period. We used generalized linear mixed models to measure the association between zip code–level racial, ethnic, and socioeconomic composition and age‐adjusted rates of LAAO in the most populous 25 metropolitan areas with LAAO sites. During the study period, 507 candidate hospitals started LAAO programs, and 745 candidate hospitals did not. Most new LAAO programs opened in metropolitan areas (97.4%). Compared with non‐LAAO centers, LAAO centers treated patients with higher median household incomes (difference of $913 [95% CI, $197–$1629], P =0.01). Zip code–level rates of LAAO procedures per 100 000 Medicare beneficiaries in large metropolitan areas were 0.34% (95% CI, 0.33%–0.35%) lower for each $1000 zip code–level decrease in median household income. After adjustment for socioeconomic markers, age, and clinical comorbidities, LAAO rates were lower in zip codes with higher proportions of Black or Hispanic patients. Conclusions Growth in LAAO programs in the United States had been concentrated in metropolitan areas. LAAO centers treated wealthier patient populations in hospitals without LAAO programs. Within major metropolitan areas with LAAO programs, zip codes with higher proportions of Black and Hispanic patients and more patients experiencing socioeconomic disadvantage had lower age‐adjusted rates of LAAO. Thus, geographic proximity alone may not ensure equitable access to LAAO. Unequal access to LAAO may reflect disparities in referral patterns, rates of diagnosis, and preferences for using novel therapies experienced by racial and ethnic minority groups and patients experiencing socioeconomic disadvantage.
Cardiac computed tomography following Watchman FLX implantation: device-related thrombus or device healing?
Abstract Aims Cardiac computed tomography (CT) is increasingly utilized during follow-up after left atrial appendage closure (LAAC). Hypoattenuated thickening (HAT) is a common finding and might represent either benign device healing or device-related thrombosis (DRT). The appearance and characteristics of HAT associated with the Watchman FLX have not been previously described. Therefore, we sought to investigate cardiac CT findings during follow-up after Watchman FLX implantation with a focus on HAT and DRT. Methods and results Retrospective single-centre, observational study including all patients with successful Watchman FLX implantation and follow-up cardiac CT between March 2019 and September 2021 (n = 244). Blinded analysis of CT images was performed describing the localization, extent, and morphology of HAT and correlated to imaging and histology findings in a canine model. Relevant clinical and preclinical ethical approvals were obtained. Overall, HAT was present in 156 cases (64%) and could be classified as either subfabric hypoattenuation (n = 59), flat sessile HAT (n = 78), protruding sessile HAT (n = 16), or pedunculated HAT (n = 3). All cases of pedunculated HAT and five cases of protruding sessile HAT were considered as high-grade HAT (n = 7). Subfabric hypoattenuation and flat sessile HAT correlated with device healing and endothelialization in histological analysis of explanted devices. Conclusion Subfabric hypoattenuation and flat sessile HAT are frequent CT findings for Watchman FLX, likely representing benign device healing and endothelialization. Pedunculated HAT and protruding HAT are infrequent CT findings that might represent DRT.
Preemptive Septal Radiofrequency Ablation to Prevent Left Ventricular Outflow Tract Obstruction With Transcatheter Mitral Valve Replacement: A Case Series
Background: Left ventricular outflow tract obstruction may occur following transcatheter mitral valve replacement in the setting of mitral annular calcification. Methods: We present a case series whereby preemptive septal radiofrequency ablation (RADIO-TMVR) was used to augment the left ventricular outflow tract for transcatheter mitral valve replacement in 4 patients at risk for left ventricular outflow tract obstruction despite alcohol septal ablation. Results: All patients were female, average age of 74.9 (68.8–80.4) years. Baseline ejection fraction was 71% (63%–75%). Mean mitral valve area was 1.28 (range, 1.0–1.59) cm 2 . Mean mitral valve gradient at rest was 9.5 (range, 7–11) mm Hg. New York Heart Association symptoms were III to IV at baseline. Patients underwent preemptive septal radiofrequency ablation to prevent left ventricular outflow tract obstruction with transcatheter mitral valve replacement a range between 69 and 154 days after alcohol septal ablation. Procedural time was 384 (337–424) minutes with a fluoroscopic time of 31 (14–71) minutes. Radiofrequency ablation time was 132 (100–175) minutes. As anticipated, 3 patients developed complete heart block and underwent pacemaker implantation, whereas 1 had a preexisting pacemaker. One patient developed groin hematoma and heart failure exacerbation. There were no peri-procedural deaths. Preemptive septal radiofrequency ablation to prevent left ventricular outflow tract obstruction with transcatheter mitral valve replacement resulted in septal end-diastolic wall thickness reduction compared with baseline (28.6%, 30.4%, 30.3%, and 11.1%) and following alcohol septal ablation (23.1%, 12%, 8.5%). Valve replacement in the setting of mitral annular calcification was performed in all patients 89 (range, 38–45) days after preemptive septal radiofrequency ablation to prevent left ventricular outflow tract obstruction with transcatheter mitral valve replacement. Two patients had concomitant laceration of the anterior mitral leaflet to further augment the neo-left ventricular outflow tract. Postprocedure, New York Heart Association symptoms improved to class I (3 patients) and class II (1 patient). Conclusions: In at-risk individuals, preemptive septal radiofrequency ablation may be an effective strategy at preventing left ventricular outflow tract obstruction with transcatheter mitral valve replacement.