The effect of concomitant fields in fast spin echo acquisition on asymmetric MRI gradient systems
Tao, Shengzhen , Weavers, Paul T., Trzasko, Joshua D. , Shu, Yunhong , Gray, Erin M. , Foo, Thomas , Bernstein, Matt A. , Bernstein, Matt A , Huston, John , Foo, Thomas K F

Magnetic Resonance in Medicine | June 23, 2017 | Volume: 79 | Issue: 3 | Pages: 1354-1364

10.1002/mrm.26789 Get It

PurposeTo investigate the effect of the asymmetric gradient concomitant fields (CF) with zeroth and first‐order spatial dependence on fast/turbo spin‐echo acquisitions, and to demonstrate the effectiveness of their real‐time compensation.MethodsAfter briefly reviewing the CF produced by asymmetric gradients, the effects of the additional zeroth and first‐order CFs on these systems are investigated using extended‐phase graph simulations. Phantom and in vivo experiments are performed to corroborate the simulation. Experiments are performed before and after the real‐time compensations using frequency tracking and gradient pre‐emphasis to demonstrate their effectiveness in correcting the additional CFs. The interaction between the CFs and prescan‐based correction to compensate for eddy currents is also investigated.ResultsIt is demonstrated that, unlike the second‐order CFs on conventional gradients, the additional zeroth/first‐order CFs on asymmetric gradients cause substantial signal loss and dark banding in fast spin‐echo acquisitions within a typical brain‐scan field of view. They can confound the prescan correction for eddy currents and degrade image quality. Performing real‐time compensation successfully eliminates the artifacts.ConclusionsWe demonstrate that the zeroth/first‐order CFs specific to asymmetric gradients can cause substantial artifacts, including signal loss and dark bands for brain imaging. These effects can be corrected using real‐time compensation. Magn Reson Med 79:1354–1364, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils
Weavers, Paul T., Tao, Shengzhen , Trzasko, Joshua D. , Frigo, Louis M., Shu, Yunhong , Frick, Matthew A., Foo, Thomas , Bernstein, Matt A. , Bernstein, Matt A , Lee, Seung‐Kyun , Foo, Thomas K F

Magnetic Resonance in Medicine | June 22, 2017 | Volume: 79 | Issue: 3 | Pages: 1538-1544

10.1002/mrm.26790 Get It

PurposeImaging gradients result in the generation of concomitant fields, or Maxwell fields, which are of increasing importance at higher gradient amplitudes. These time‐varying fields cause additional phase accumulation, which must be compensated for to avoid image artifacts. In the case of gradient systems employing symmetric design, the concomitant fields are well described with second‐order spatial variation. Gradient systems employing asymmetric design additionally generate concomitant fields with global (zeroth‐order or B0) and linear (first‐order) spatial dependence.MethodsThis work demonstrates a general solution to eliminate the zeroth‐order concomitant field by applying the correct B0 frequency shift in real time to counteract the concomitant fields. Results are demonstrated for phase contrast, spiral, echo‐planar imaging (EPI), and fast spin‐echo imaging.ResultsA global phase offset is reduced in the phase‐contrast exam, and blurring is virtually eliminated in spiral images. The bulk image shift in the phase‐encode direction is compensated for in EPI, whereas signal loss, ghosting, and blurring are corrected in the fast‐spin echo images.ConclusionA user‐transparent method to compensate the zeroth‐order concomitant field term by center frequency shifting is proposed and implemented. This solution allows all the existing pulse sequences—both product and research—to be retained without any modifications. Magn Reson Med 79:1538–1544, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Gradient pre-emphasis to counteract first-order concomitant fields on asymmetric MRI gradient systems
Tao, Shengzhen , Weavers, Paul T., Trzasko, Joshua D. , Shu, Yunhong , Frigo, Louis M., Bernstein, Matt A. , Bernstein, Matt A , Huston, John , Lee, Seung‐Kyun

Magnetic Resonance in Medicine | July 4, 2016 | Volume: 77 | Issue: 6 | Pages: 2250-2262

10.1002/mrm.26315 Get It

High slew‐rate head‐only gradient for improving distortion in echo planar imaging: Preliminary experience
Tan, Ek T. , Lee, Seung‐Kyun , Weavers, Paul T., Graziani, Dominic, Piel, Joseph E., Shu, Yunhong , Bernstein, Matt A. , Foo, Thomas , Huston, John , Bernstein, Matt A , Foo, Thomas K F , Tan, Ek T

Journal of Magnetic Resonance Imaging | February 27, 2016 | Volume: 44 | Issue: 3 | Pages: 653-664

10.1002/jmri.25210 Get It

PurposeTo investigate the effects on echo planar imaging (EPI) distortion of using high gradient slew rates (SR) of up to 700 T/m/s for in vivo human brain imaging, with a dedicated, head‐only gradient coil.Materials and MethodsSimulation studies were first performed to determine the expected echo spacing and distortion reduction in EPI. A head gradient of 42‐cm inner diameter and with asymmetric transverse coils was then installed in a whole‐body, conventional 3T magnetic resonance imaging (MRI) system. Human subject imaging was performed on five subjects to determine the effects of EPI on echo spacing and signal dropout at various gradient slew rates. The feasibility of whole‐brain imaging at 1.5 mm‐isotropic spatial resolution was demonstrated with gradient‐echo and spin‐echo diffusion‐weighted EPI.ResultsAs compared to a whole‐body gradient coil, the EPI echo spacing in the head‐only gradient coil was reduced by 48%. Simulation and in vivo results, respectively, showed up to 25–26% and 19% improvement in signal dropout. Whole‐brain imaging with EPI at 1.5 mm spatial resolution provided good whole‐brain coverage, spatial linearity, and low spatial distortion effects.ConclusionOur results of human brain imaging with EPI using the compact head gradient coil at slew rates higher than in conventional whole‐body MR systems demonstrate substantially improved image distortion, and point to a potential for benefits to non‐EPI pulse sequences. J. Magn. Reson. Imaging 2016;44:653–664.
Partial fourier and parallel MR image reconstruction with integrated gradient nonlinearity correction
Tao, Shengzhen , Trzasko, Joshua D. , Shu, Yunhong , Weavers, Paul T., Gray, Erin M. , Bernstein, Matt A. , Huston, John , Bernstein, Matt A

Magnetic Resonance in Medicine | July 17, 2015 | Volume: 75 | Issue: 6 | Pages: 2534-2544

10.1002/mrm.25842 Get It

PurposeTo describe how integrated gradient nonlinearity (GNL) correction can be used within noniterative partial Fourier (homodyne) and parallel (SENSE and GRAPPA) MR image reconstruction strategies, and demonstrate that performing GNL correction during, rather than after, these routines mitigates the image blurring and resolution loss caused by postreconstruction image domain based GNL correction.MethodsStarting from partial Fourier and parallel magnetic resonance imaging signal models that explicitly account for GNL, noniterative image reconstruction strategies for each accelerated acquisition technique are derived under the same core mathematical assumptions as their standard counterparts. A series of phantom and in vivo experiments on retrospectively undersampled data were performed to investigate the spatial resolution benefit of integrated GNL correction over conventional postreconstruction correction.ResultsPhantom and in vivo results demonstrate that the integrated GNL correction reduces the image blurring introduced by the conventional GNL correction, while still correcting GNL‐induced coarse‐scale geometrical distortion. Images generated from undersampled data using the proposed integrated GNL strategies offer superior depiction of fine image detail, for example, phantom resolution inserts and anatomical tissue boundaries.ConclusionNoniterative partial Fourier and parallel imaging reconstruction methods with integrated GNL correction reduce the resolution loss that occurs during conventional postreconstruction GNL correction while preserving the computational efficiency of standard reconstruction techniques. Magn Reson Med 75:2534–2544, 2016. © 2015 Wiley Periodicals, Inc.
Magnetic resonance imaging in Alzheimer's Disease Neuroimaging Initiative 2
Jack, Clifford R. , Barnes, Josephine , Bernstein, Matt A. , Borowski, Bret, Brewer, James, Clegg, Shona , Dale, Anders M. , Carmichael, Owen , Ching, Christopher R. K. , DeCarli, Charles , Desikan, Rahul S. , Fennema‐Notestine, Christine , Fjell, Anders M. , Fox, Nick C. , Gunter, Jeff, Holland, Dominic , Hua, Xue , Kantarci, Kejal , Krueger, Gunnar, Leung, Kelvin K., Mackin, Scott, Maillard, Pauline , Malone, Ian B. , Mattsson, Niklas , McEvoy, Linda K. , Modat, Marc , Mueller, Susanne G. , Nosheny, Rachel L. , Ourselin, Sébastien , Schuff, Norbert, Senjem, Matthew L. , Simonson, Alix, Thompson, Paul M. , Rettmann, Dan , Vemuri, Prashanthi , Walhovd, Kristine B. , Zhao, Yansong , Zuk, Samantha M., Weiner, Michael W. , DeCarli, Charles , Borowski, Bret J, Zuk, Samantha, Fletcher, Evan M. , Gutman, Boris A , Insel, Philip S. , Killiany, Ronald , Bernstein, Matt A , Jack, Clifford R , Vemuri, Prashanthi , Dale, Anders M , Thompson, Paul M , Senjem, Matthew L , Ching, Christopher R K , Kantarci, Kejal , Fox, Nick C , Maillard, Pauline

Alzheimer's & Dementia | July 17, 2015 | Volume: 11 | Issue: 7 | Pages: 740-756

10.1016/j.jalz.2015.05.002 Get It

AbstractIntroductionAlzheimer's Disease Neuroimaging Initiative (ADNI) is now in its 10th year. The primary objective of the magnetic resonance imaging (MRI) core of ADNI has been to improve methods for clinical trials in Alzheimer's disease (AD) and related disorders.MethodsWe review the contributions of the MRI core from present and past cycles of ADNI (ADNI‐1, ‐Grand Opportunity and ‐2). We also review plans for the future‐ADNI‐3.ResultsContributions of the MRI core include creating standardized acquisition protocols and quality control methods; examining the effect of technical features of image acquisition and analysis on outcome metrics; deriving sample size estimates for future trials based on those outcomes; and piloting the potential utility of MR perfusion, diffusion, and functional connectivity measures in multicenter clinical trials.DiscussionOver the past decade the MRI core of ADNI has fulfilled its mandate of improving methods for clinical trials in AD and will continue to do so in the future.
MRI in radiation oncology: Underserved needs
McGee, Kiaran P. , Hu, Yanle , Tryggestad, E., Brinkmann, Debra H. , Witte, Bob, Welker, Kirk M. , Panda, Anshuman , Haddock, Michael G. , Bernstein, Matt A. , Tryggestad, Erik, Brinkmann, Debra, Welker, Kirk, Haddock, Michael, Bernstein, Matt A

Magnetic Resonance in Medicine | July 14, 2015 | Volume: 75 | Issue: 1 | Pages: 11-14

10.1002/mrm.25826 Get It

Integrated image reconstruction and gradient nonlinearity correction
Tao, Shengzhen , Trzasko, Joshua D. , Shu, Yunhong , Bernstein, Matt A. , Huston, John , Bernstein, Matt A

Magnetic Resonance in Medicine | October 8, 2014 | Volume: 74 | Issue: 4 | Pages: 1019-1031

10.1002/mrm.25487 Get It

PurposeTo describe a model‐based reconstruction strategy for routine magnetic resonance imaging that accounts for gradient nonlinearity (GNL) during rather than after transformation to the image domain, and demonstrate that this approach reduces the spatial resolution loss that occurs during strictly image‐domain GNL‐correction.MethodsAfter reviewing conventional GNL‐correction methods, we propose a generic signal model for GNL‐affected magnetic resonance imaging acquisitions, discuss how it incorporates into contemporary image reconstruction platforms, and describe efficient nonuniform fast Fourier transform‐based computational routines for these. The impact of GNL‐correction on spatial resolution by the conventional and proposed approaches is investigated on phantom data acquired at varying offsets from gradient isocenter, as well as on fully sampled and (retrospectively) undersampled in vivo acquisitions.ResultsPhantom results demonstrate that resolution loss that occurs during GNL‐correction is significantly less for the proposed strategy than for the standard approach at distances >10 cm from isocenter with a 35 cm field‐of‐view gradient coil. The in vivo results suggest that the proposed strategy better preserves fine anatomical detail than retrospective GNL‐correction while offering comparable geometric correction.ConclusionAccounting for GNL during image reconstruction allows geometric distortion to be corrected with less spatial resolution loss than is typically observed with the conventional image domain correction strategy. Magn Reson Med 74:1019–1031, 2015. © 2014 Wiley Periodicals, Inc.
Patents and Pasteur: Why new metrics may point to imaging science as a model for innovation
Kalutkiewicz, Michael J., Bernstein, Matt A. , Ehman, Richard L. , Bernstein, Matt A

Magnetic Resonance in Medicine | August 8, 2014 | Volume: 72 | Issue: 5 | Pages: 1199-1200

10.1002/mrm.25413 Get It