Back to Authors

Baumann, Nikola A

Mayo Clinic

Department of Laboratory Medicine and Pathology, Mayo Clinic Rochester, Minnesota.

Citations 22

New Insights into Unexpected Enzymatic Creatinine Assay Interference: A Case of Acetaminophen Toxicity
Swartchick, Chelsea B. , Rosemark, Christopher L., Block, Darci R , Baumann, N, Katzman, Brooke M. , Baumann, Nikola A

The Journal of Applied Laboratory Medicine | June 30, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/jalm/jfag111 Get It

Feasibility of Capillary Self-Collected Blood Specimens for Routine Outpatient Laboratory Testing
Swartchick, Chelsea B. , Gurudu, Rachana, Lexvold, Nathanael S, Lasho, Michael A., Baumann, N, Block, Darci R , Katzman, Brooke M. , Meeusen, Jeffrey W. , Baumann, Nikola A

The Journal of Applied Laboratory Medicine | April 23, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/jalm/jfag075 Get It

Abstract Background Capillary self-collection (CSC) devices allow patients to collect blood samples at home, potentially reducing outpatient phlebotomy visits. This study aimed to (a) assess the patient experience with multiple commercially available CSC devices; (b) determine which laboratory tests are commonly ordered together, which could reduce the need for appointments; and (c) evaluate the analytical performance of these tests using CSC samples. Methods User experience for 3 CSC devices was evaluated. Clinical feasibility was determined by comparing test results in paired sera collected by venipuncture (VP) and CSC devices. VP samples were centrifuged within 2 h and tested immediately. CSC sera were centrifuged and tested both immediately and after delayed processing to simulate shipping temperature extremes (−20°C or 40°C). Basic metabolic panel, lipid panel, thyroid function cascade, and prostate-specific antigen were evaluated. Differences between VP and CSC collections were characterized according to their statistical and clinical differences. Results Patients reported CSC devices were easy to use and painless. Clinically significant differences between VP and CSC sera processed immediately were limited to potassium and bicarbonate. Following delayed processing of CSC serum samples (48 h at room temperature), clinically significant differences in potassium, bicarbonate, and glucose were observed. Frozen samples could not be analyzed. A 48 h delay at 40°C caused clinically significant differences in all analytes except creatinine, lipid panel, prostate-specific antigen, and the thyroid cascade. Conclusion Potassium, bicarbonate, and glucose were not stable at room temperature in CSC sera. CSC serum specimens may be a viable option but require analyte-specific evaluation and consideration of transportation conditions.
Low magnesium levels and prognosis in newly diagnosed diffuse large B-cell lymphoma
Gile, Jennifer , Maurer, Matthew J. , Ruan, Gordon , Abeykoon, Jithma P. , Heimgartner, Joy , Baumann, N, McMahon, Molly, Gile, Jennifer Jane , Maurer, Matthew , Ruan, Gordon J , Heimgartner, Joy R, Baumann, Nikola A, Lin, Yi , Witzig, Thomas E.

The Oncologist | October 17, 2024 | Volume: 29 | Issue: 12 | Pages: e1779-e1782

10.1093/oncolo/oyae255 Get It

Abstract Magnesium (Mg) is an essential element involved in cellular metabolism. We demonstrated that in patients with diffuse large B-cell lymphoma (DLBCL) undergoing autologous stem cell transplant (SCT), those with a serum Mg < 2.0 mg/dL at the time of transplant had worse outcomes. In this study, we aimed to learn the prognostic value of low serum Mg in patients with untreated DLBCL. We analyzed serum from 408 patients and tested 2 Mg cutpoints—low (<1.7 mg/dL) and low normal (<2.0 mg/dL), a range we found associated with lower survival in the SCT group. We found 3% of patients with low levels and 23% with low normal levels. Low normal serum Mg levels were associated with a higher stage at diagnosis, more extranodal involvement, higher international prognostic index score, lower overall survival (OS), and event-free survival. These data warrant testing Mg replacement to a target of >2.0 mg/dL to learn if survival can be improved.
Limited Correlation between SARS-CoV-2 Serologic Assays for Identification of High-Titer COVID-19 Convalescent Plasma Using FDA Thresholds
Larkey, Nicholas E., Ewaisha, Radwa , Lasho, Michael A., Roforth, Matthew M., Granger, Dane, Jerde, Calvin R. , Gorsh, Amy P., Klassen, Stephen A. , Senefeld, Jonathon W. , Joyner, Michael J. , Baumann, N, Theel, Elitza S. , Mills, John R. , Wu, Liang, Gorsh, Amy, Baumann, Nikola A, Theel, Elitza S , Mills, J R , Joyner, Michael J , Senefeld, Jonathon W , Klassen, Stephen A , Wu, Liang Li

Microbiology Spectrum | July 5, 2022 | Volume: 10 | Issue: 4 | Pages: No page available

10.1128/spectrum.01154-22 Get It

COVID-19 convalescent plasma (CCP) was one of the first therapeutic options available for the treatment of SARS-CoV-2 infections and continues to be used selectively for immunosuppressed patients. Given the emergence of novel SARS-CoV-2 variants which are resistant to treatment with available monoclonal antibody (MAb) therapy, CCP remains an important therapeutic consideration.
Short- and Long-Term Biological Variability of Small Dense LDL, HDL3, and Triglyceride-Rich Lipoprotein Cholesterol
Fatica, Erica M. , Jenkins, Sarah M. , Scott, Renee, Block, Darci R , Meeusen, Jeffrey W. , Baumann, N, Saenger, Amy K., Scott, Renee’ J, Baumann, Nikola A, Donato, Leslie J.

The Journal of Applied Laboratory Medicine | May 11, 2022 | Volume: 7 | Issue: 5 | Pages: 1047-1061

10.1093/jalm/jfac039 Get It

Abstract Background Measurement of cholesterol within lipoprotein subfractions may aid in cardiovascular disease prediction. Simple, homogenous enzymatic assays for the direct measurement of lipoprotein subfractions have been developed to measure small dense low-density lipoprotein cholesterol (sdLDL-C), high-density lipoprotein-3 cholesterol (HDL3-C), and triglyceride-rich lipoprotein (TRL-C) cholesterol. The objective of this study was to determine biological variability for sdLDL-C, HDL3-C, and TRL-C in a healthy reference population to facilitate interpretation of these analytes. Methods Serum samples were collected from 24 healthy subjects (n = 14 female/10 male) daily for 3 days while non-fasting, and daily for 5 days, weekly for 4 weeks, and monthly for 6 months after overnight fasting. sdLDL-C, HDL3-C, and TRL-C cholesterol were measured by homogenous enzymatic assays. Sources of variability (between-subject, within-subject, and analytical) were calculated using random-effects regression models. Reference change value (RCV) and index of individuality (II) for each time period were determined from the variance components. Results Analytic variability (daily, weekly, and monthly CVA) was <3% for each analyte. Monthly within-subject variability (CVI) was 17.1% for sdLDL-C, 7.4% for HDL3-C, and 25.7% for TRL-C. Most of the monthly variation was attributed to between-subject variation for all 3 analytes. Overall RCVs for monthly measurements were 18.1 mg/dL for sdLDL-C, 6.1 mg/dL for HDL3-C, and 16.0 mg/dL for TRL-C. IIs were <0.6 for sdLDL-C and HDL3-C, and 0.81 for TRL-C. Conclusions sdLDL-C, HDL3-C, and TRL-C showed moderate within-subject variability, but high between-subject variability, in a healthy reference population. Given the high individuality of each analyte, population-based reference intervals may be inadequate to detect clinically significant changes.
The Biological Variability of Plasma Ceramides in Healthy Subjects
Ramos, Paola , Jenkins, Sarah M. , Hartman, Stacy, Saenger, Amy K., Baumann, N, Block, Darci R , Jaffe, Allan S. , Meeusen, Jeffrey W. , Donato, Leslie J. , Hartman, Stacy J, Baumann, Nikola A, Block, Darci R , Jaffe, Allan S.

The Journal of Applied Laboratory Medicine | January 6, 2022 | Volume: 7 | Issue: 4 | Pages: 863-870

10.1093/jalm/jfac002 Get It

AbstractBackgroundCeramides are bioactive lipid species that mediate numerous cell-signaling events. Elevated plasma ceramides concentration constitutes a risk factor for several pathologies. Multiple studies have affirmed the plasma concentrations of 4 specific ceramides (Cer16:0, Cer18:0, Cer24:0, and Cer24:1) can predict cardiovascular disease risk. Furthermore, these ceramides can be altered by many lipid-lowering therapies. Understanding the biological variability within an individual, and within a population, will further inform the clinical use of plasma ceramides as a biomarker. In this study, we aimed to define the intra- and interbiological variability of ceramides in a healthy reference population in a weekly and monthly manner.MethodsFasting plasma from 24 healthy adults was collected daily (5 days), weekly (4 weeks), and monthly (7 months). Ceramide concentrations were measured with liquid chromatography–mass spectrometry (LC–MS). For analysis, we used random-effects regression models to estimate variance components.ResultsThe analytical variability was smaller compared to the biological variability overall. The greatest variation reported was between-subject variation for all ceramide species. The critical difference-reference change value (RCV) for within-subject variations monthly were 0.07 mcmol/L (Cer16:0), 0.04 mcmol/L (Cer18:0), 1.09 mcmol/L (Cer24:0), and 0.27 mcmol/L (Cer24:1). The index of individuality (IOI) of ceramides were 0.82 (Cer16:0), 0.96 (Cer18:0), 1.06 (Cer24:0), and 0.89 (Cer24:1). The most consistent ceramide species was Cer18:0 with the lowest within- and between-subject critical differences in weekly and monthly measurements.ConclusionsOverall, this study demonstrates that the variability of ceramide concentrations at different time points is minimal within individuals, allowing a single draw to be sufficient at least in a yearly time frame.
SARS-CoV-2 Serologic Assays Dependent on Dual-Antigen Binding Demonstrate Diverging Kinetics Relative to Other Antibody Detection Methods
Theel, Elitza S. , Gorsh, Amy P., Granger, Dane, Roforth, Matthew M., Jerde, Calvin R. , Lasho, Michael A., Andersen, Kylie J. , Murphy, Brenna M., Harring, Julie, Lake, Douglas F. , Svarovsky, Sergei, Senefeld, Jonathon W. , Carter, Rickey E. , Joyner, Michael J. , Baumann, N, Mills, John R. , Kunze, Katie L. , Wu, Liang, Lasho, Michael, Baumann, Nikola A, Carter, Rickey E , Andersen, Kylie , Joyner, Michael J , Senefeld, Jonathon W , Johnson, Patrick W. , Wu, Liang Li

Journal of Clinical Microbiology | August 18, 2021 | Volume: 59 | Issue: 9 | Pages: No page available

10.1128/jcm.01231-21 Get It

Longitudinal studies assessing durability of the anti-severe acute respiratory syndrome coronavirus 2 (anti-SARS-CoV-2) humoral immune response have generated conflicting results. This has been proposed to be due to differences in patient populations, the lack of standardized methodologies, and the use of assays that measure distinct aspects of the humoral response.
The new Roche Elecsys TSH assay conforms with current IFCC C-STFT standards
Kratzsch, Jüergen, Baumann, N, Ceriotti, Ferruccio , Lu, Zhong X. , Herwaarden, Antonius E. van , Lehmann, H. , Kasapic, Dusanka , Giovanella, Luca , Baumann, Nikola A, Giovanella, Luca , Schott, Matthias , Vieira, José Gilberto H. , Lehmann, Holger

Clinical Chemistry and Laboratory Medicine (CCLM) | July 12, 2021 | Volume: 59 | Issue: 12 | Pages: e445-e448

10.1515/cclm-2021-0352 Get It

Validation of a Commercial Reagent for the Depletion of Biotin from Serum/Plasma: A Rapid and Simple Tool to Detect Biotin Interference with Immunoassay Testing
Katzman, Brooke M. , Hain, Erin A, Baumann, N, Baumann, Nikola A, Donato, Leslie J.

The Journal of Applied Laboratory Medicine | March 22, 2021 | Volume: 6 | Issue: 4 | Pages: 992-997

10.1093/jalm/jfab022 Get It

Abstract Background It is important for clinical laboratories to have protocols for investigating suspected biotin interference in patient samples. VeraPrep Biotin™ is a commercial product used to rapidly deplete biotin from serum/plasma samples. The objectives of this study were to verify that VeraPrep Biotin™: (a) does not impact immunoassay analyte recovery in control samples and (b) can effectively deplete biotin from samples (both biotin-spiked and samples from donors who ingested biotin supplements). Methods De-identified residual waste serum/plasma samples were combined to create 9 pools for each immunoassay. Plasma/serum samples (n = 23) were obtained from 6 healthy donors at varying times following ingestion of biotin (20 mg, 100 mg, or 200 mg). Nine Elecsys immunoassays were evaluated using the e 602 (Roche Diagnostics Inc.). Control, biotin-spiked (n = 10, ∼400 ng/mL), and donor samples were assayed pre- and post-VeraPrep treatment. Percentage analyte recovery [(posttreatment/pretreatment) × 100] was calculated for control samples. A laboratory-developed LC–MS/MS method was used to quantify biotin. Results In control samples (n = 81), 90–110% analyte recovery was observed post-VeraPrep treatment in over 95% of samples (77/81). The pre- and post-VeraPrep treatment biotin concentration [mean ± standard deviation (SD)] for specimens spiked with up to 500 ng/mL biotin was 357 ± 47 ng/mL and 1.0 ± 0.6 ng/mL, respectively. The mean (range) biotin concentration for the donor samples pre- and post-treatment was 166 (15–1029) ng/mL and 0.2 (<0.1–3) ng/mL, respectively (P = 0.004). Conclusions These data demonstrate that treatment with VeraPrep Biotin™ does not affect analyte recovery in biotin-negative samples and effectively depletes both spiked and endogenous biotin in serum/plasma.
Effect of pH on the Quantification of Common Chemistry Analytes in Body Fluid Specimens Using the Roche cobas Analyzer for Clinical Diagnostic Testing
Nandakumar, Vijayalakshmi, Dolan, Christopher, Baumann, N, Block, Darci R , Dolan, Christopher T, Baumann, Nikola A

American Journal of Clinical Pathology | March 10, 2021 | Volume: 156 | Issue: 5 | Pages: 722-727

10.1093/ajcp/aqab025 Get It

Abstract Objectives To determine the influence of pH on recovery of analytes in body fluids (BFs), investigate the mechanism of pH interference, measure the frequency of abnormal-pH BFs received, and compare pH measured by meter and paper. Methods We performed pH titration in residual BFs. A low-pH BF was spiked and neutralized to investigate pH interference. We measured analytes on a Roche cobas c501 analyzer (Roche Diagnostics) and calculated the percent recovery. Measurement of pH using a meter and paper was conducted on 122 BF samples received in the laboratory. Results Enzyme activity in BFs was unaffected when pH = 7.4-8.5 lactate dehydrogenase, pH = 7.3-10.2 amylase, pH = 6.0-9.9 lipase, and pH = 1.3-11.7 all other analytes. BFs had mean (range) pH of 8.0 (5.1-8.9), with a mean (range) difference (paper ‒ meter) of ‒0.4 (‒0.6 to 1.1). Conclusions Irreversible loss of enzyme activity occurs in BFs at low pH. Few clinical BFs have pH < 7.0, but laboratories should incorporate pH measurement in BF workflows.