A-189 Volume Matters: Continuous Improvement to Reduce Blood Collection Volumes and Collection Tube Utilization
Hain, Erin A, Hendrix, B K, Stelpflug, Amy J., Elliott, Eileen A., Boedecker, S A, Faber, Tracy L., Block, Darci R , Baumann, N, Elliott, E A, Faber, T L

Clinical Chemistry | September 27, 2023 | Volume: 69 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvad097.170 Get It

Abstract Background Clinical laboratories are constantly changing with automated analyzers and total lab automation (TLA) implemented and replaced over time. Some benefits of newer technologies include decreased specimen volume requirements, less need for repeat testing, and greater throughput. Recent implementation of new analyzers and replacement of TLA in the Central Clinical Laboratory (CCL) at Mayo Clinic, Rochester, MN, prompted the laboratory to reassess blood collection volumes for commonly ordered tests. Objectives The aim of this study was to evaluate whether updating the blood collection volumes for clinical chemistry and immunoassay tests performed in the CCL could reduce the volume of blood collected from patients and the number of blood collection tubes utilized. Methods Nearly 100 different serum assays from the CCL test menu were reviewed including the basic and comprehensive metabolic, hepatic function, renal function, electrolyte, and lipid panels as well as thyroid function tests, enzymes, hormones, electrolytes, and iron status tests. Cortisol, ferritin, folate, and Vitamin B12 testing were performed on the Beckman DxI800; all other testing was on Roche Diagnostics Cobas 8000 chemistry (ISE, c701, c502) and immunoassay (e801) analyzers. Updated blood volumes for each assay were calculated utilizing manufacturer’s analytical volumes and “dead volume” requirements. Baseline data retrieved from the laboratory information system (LIS) included blood collection volumes and number of tubes collected for 128 patients with physician-orders for laboratory testing on 5/2/21. The collection logic was then updated in the test LIS environment using the new blood volumes requirements and applied to the same 128 orders. Blood volumes and number of tubes collected per order were compared before and after the volume updates. Results Baseline data from 128 unique orders showed that 414 total tubes were collected with a median(range) of 3 (2–6) tubes per order and 5 (1–18) tests per tube. The total volume of blood requested at baseline was 2065 mL. Post-intervention, 197 tubes were needed with a median(range) of 2 (1–3) tubes per order and 13 (1–30) tests per tube. The total volume of blood requested after updating volumes was 851 mL. Conclusions The practice of reviewing and updating specimen volume requirements when replacing or implementing new analyzers or TLA can greatly reduce the volume of blood collected from patients and the number of blood collection tubes per order. In this study of 128 physician orders for common laboratory tests, updating blood collection information in the LIS reduced the requested blood collection volumes by 59% and decreased the number of blood collection tubes required by 52%. This not only benefits patients because less blood is collected but also conserves blood collection tubes and reduces supply chain demands. Additionally, fewer tubes on the TLA system has the potential to improve throughput and test turnaround time.
Validation of a Commercial Reagent for the Depletion of Biotin from Serum/Plasma: A Rapid and Simple Tool to Detect Biotin Interference with Immunoassay Testing
Katzman, Brooke M. , Hain, Erin A, Baumann, N, Baumann, Nikola A, Donato, Leslie J.

The Journal of Applied Laboratory Medicine | March 22, 2021 | Volume: 6 | Issue: 4 | Pages: 992-997

10.1093/jalm/jfab022 Get It

Abstract Background It is important for clinical laboratories to have protocols for investigating suspected biotin interference in patient samples. VeraPrep Biotin™ is a commercial product used to rapidly deplete biotin from serum/plasma samples. The objectives of this study were to verify that VeraPrep Biotin™: (a) does not impact immunoassay analyte recovery in control samples and (b) can effectively deplete biotin from samples (both biotin-spiked and samples from donors who ingested biotin supplements). Methods De-identified residual waste serum/plasma samples were combined to create 9 pools for each immunoassay. Plasma/serum samples (n = 23) were obtained from 6 healthy donors at varying times following ingestion of biotin (20 mg, 100 mg, or 200 mg). Nine Elecsys immunoassays were evaluated using the e 602 (Roche Diagnostics Inc.). Control, biotin-spiked (n = 10, ∼400 ng/mL), and donor samples were assayed pre- and post-VeraPrep treatment. Percentage analyte recovery [(posttreatment/pretreatment) × 100] was calculated for control samples. A laboratory-developed LC–MS/MS method was used to quantify biotin. Results In control samples (n = 81), 90–110% analyte recovery was observed post-VeraPrep treatment in over 95% of samples (77/81). The pre- and post-VeraPrep treatment biotin concentration [mean ± standard deviation (SD)] for specimens spiked with up to 500 ng/mL biotin was 357 ± 47 ng/mL and 1.0 ± 0.6 ng/mL, respectively. The mean (range) biotin concentration for the donor samples pre- and post-treatment was 166 (15–1029) ng/mL and 0.2 (<0.1–3) ng/mL, respectively (P = 0.004). Conclusions These data demonstrate that treatment with VeraPrep Biotin™ does not affect analyte recovery in biotin-negative samples and effectively depletes both spiked and endogenous biotin in serum/plasma.