Back to Authors

Douglas, Pamela S.

https://orcid.org/0000-0001-9876-4049

Mayo Clinic

Duke University

Citations 30

Outcomes of Transcatheter Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Disease
Halim, Sharif, Edwards, Fred H., Dai, David , Li, Zhuokai , Mack, Michael J. , Holmes, David R. , Tuzcu, E. Murat , Thourani, Vinod H. , Harrison, J. Kevin , Brennan, James M. , Douglas, Pamela S. , Douglas, Pamela S

Circulation | March 18, 2020 | Volume: 141 | Issue: 13 | Pages: 1071-1079

10.1161/circulationaha.119.040333 Get It

Background: Patients with bicuspid aortic valve (AV) stenosis were excluded from the pivotal evaluations of transcatheter AV replacement (TAVR) devices. We sought to evaluate the outcomes of TAVR in patients with bicuspid AV stenosis in comparison with those with tricuspid AV stenosis. Methods: We used data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry (November 2011 through November 2018) to determine device success, procedural outcomes, post-TAVR valve performance, and in-hospital clinical outcomes (mortality, stroke, and major bleeding) according to valve morphology (bicuspid versus tricuspid). Results were stratified by older and current (Sapien 3 and Evolut R) generation valve prostheses. Medicare administrative claims were used to evaluate mortality and stroke to 1 year among eligible individuals (≥65 years). Results: After exclusions, there were 170 959 eligible procedures at 593 sites during the specified interval. Of these, 5412 TAVR procedures (3.2%) were performed in patients with bicuspid AV, including 3705 with current-generation devices. In comparison with patients with tricuspid valves, patients with bicuspid AV were younger and had a lower Society of Thoracic Surgeons Predicted Risk of Operative Mortality score. When current-generation devices were used to treat patients with bicuspid AV, device success increased (93.5 versus 96.3; P =0.001) and the incidence of 2+ aortic insufficiency declined (14.0% versus 2.7%; P <0.001) in comparison with older-generation devices. With current-generation devices, device success was slightly lower in the bicuspid (versus tricuspid) AV group (96.3% in bicuspid versus 97.4% in tricuspid, P =0.07), with a slightly higher incidence of residual moderate or severe aortic insufficiency among patients with bicuspid AV (2.7% versus 2.1%; P <0.001). A lower 1-year adjusted risk of mortality (hazard ratio, 0.88 [95% CI, 0.78–0.99]) was observed for patients with bicuspid AV versus patients with tricuspid AV in the Medicare-linked cohort, whereas no difference was observed in the 1-year adjusted risk of stroke (hazard ratio, 1.14 [95% CI, 0.94–1.39]). Conclusions: Using current-generation devices, procedural, postprocedural, and 1-year outcomes were comparable following TAVR for bicuspid AV versus tricuspid AV disease. With newer-generation devices, TAVR is a viable treatment option for patients with bicuspid AV disease.
Thirty-Day Outcomes of Transcatheter Mitral Valve Replacement for Degenerated Mitral Bioprostheses (Valve-in-Valve), Failed Surgical Rings (Valve-in-Ring), and Native Valve With Severe Mitral Annular Calcification (Valve-in-Mitral Annular Calcification) in
Vemulapalli, Sreekanth , Xiang, Qun, Wang, Dee Dee , Eleid, Mackram F. , Sandhu, Gurpreet S. , Salinger, Michael H., Russell, Hyde M., Kodali, Susheel , Dvir, Danny , Russo, Mark J., Fang, Kenith, Coylewright, Megan , Shah, Pinak , Babaliaros, Vasilis , Khan, Jaffar M. , Tommaso, Carl L. , Saucedo, Jorge , Makkar, Rajj, Mack, Michael J. , Holmes, David R. , Leon, Martin B. , Bapat, Vinayak , Thourani, Vinod H. , Rihal, Charanjit S. , O’Neill, William, Feldman, Ted , Douglas, Pamela S. , Eleid, Mackram, Cabalka, Allison K. , Rihal, Charanjit, Wang, Dee Dee , Douglas, Pamela S , Guerrero, Mayra , Greenbaum, Adam B. , George, Isaac , Whisenant, Brian K. , Pershad, Ashish , Shah, Pinak , Kar, Saibal , Makkar, Raj , Rihal, Charanjit S.

Circulation: Cardiovascular Interventions | March 6, 2020 | Volume: 13 | Issue: 3 | Pages: No page available

10.1161/circinterventions.119.008425 Get It

Background: Transcatheter mitral valve replacement using aortic transcatheter heart valves has recently become an alternative for patients with degenerated mitral bioprostheses, failed surgical repairs with annuloplasty rings or severe mitral annular calcification who are poor surgical candidates. Outcomes of these procedures are collected in the Society of Thoracic Surgeons/American College of Cardiology/Transcatheter Valve Therapy Registry. A comprehensive analysis of mitral valve-in-valve (MViV), mitral valve-in-ring (MViR), and valve-in-mitral annular calcification (ViMAC) outcomes has not been performed. We sought to evaluate short-term outcomes of early experience with MViV, MViR, and ViMAC in the United States. Methods: Retrospective analysis of data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. Results: Nine hundred three high-risk patients (median Society of Thoracic Surgeons score 10%) underwent MViV (n=680), MViR (n=123), or ViMAC (n=100) between March 2013 and June 2017 at 172 hospitals. Median age was 75 years, 59.2% female. Technical and procedural success were higher in MViV. Left ventricular outflow tract obstruction occurred more frequently with ViMAC (ViMAC=10%, MViR=4.9%, MViV=0.7%; P <0.001). In-hospital mortality (MViV=6.3%, MViR=9%, ViMAC=18%; P =0.004) and 30-day mortality (MViV=8.1%, MViR=11.5%, ViMAC=21.8%; P =0.003) were higher in ViMAC. At 30-day follow-up, median mean mitral valve gradient was 7 mm Hg, most patients (96.7%) had mitral regurgitation grade ≤1 (+) and were in New York Heart Association class I to II (81.7%). Conclusions: MViV using aortic balloon-expandable transcatheter heart valves is associated with a low complication rate, a 30-day mortality lower than predicted by the Society of Thoracic Surgeons score, and superior short-term outcomes than MViR and ViMAC. At 30 days, patients in all groups experienced improvement of symptoms, and valve performance remained stable. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02245763.
Incidence, Temporal Trends, and Associated Outcomes of Vascular and Bleeding Complications in Patients Undergoing Transfemoral Transcatheter Aortic Valve Replacement
Sherwood, Matthew W. , Xiang, Katelyn, Li, Zhuokai , Vemulapalli, Sreekanth , Vora, Amit N. , Harrison, J. Kevin , Thourani, Vinod H. , Holmes, David R. , Kirtane, Ajay J. , Pineda, Andrés M. , Douglas, Pamela S. , Douglas, Pamela S , Matsouaka, Roland , Fanaroff, Alexander C. , Peterson, Eric D. , Rao, Sunil V.

Circulation: Cardiovascular Interventions | January 15, 2020 | Volume: 13 | Issue: 1 | Pages: No page available

10.1161/circinterventions.119.008227 Get It

Background: Vascular and bleeding complications were commonly reported in transcatheter aortic valve replacement clinical trials. Little is known about complication rates in contemporary US clinical practice or clinical outcomes associated with these complications. Methods: In the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry, we evaluated patients undergoing transcatheter aortic valve replacement from November 1, 2011 to June 30, 2016. The primary outcomes were in-hospital vascular complications and bleeding events. Secondary outcomes included all-cause mortality, stroke, and rehospitalization at 1 year. P values for trends were calculated for rates over time, and multivariable logistic regression was used to determine the association between vascular/bleeding complications and in-hospital clinical outcomes. Results: Overall, 34 893 patients undergoing transcatheter aortic valve replacement at 445 hospitals were analyzed. Of these, 9.3% (n=3257) experienced a vascular complication while 7.6% (n=2651) had an in-hospital bleeding event. Rates of both vascular complications and bleeding events decreased over time ( P value for trend test <0.0001); however, there was significant variation in rates across hospital sites (adjusted median rate, 11.4%; IQR, 8.9–14.5). Vascular complications were independently associated with 30-day death (adjusted HR, 2.23 [95% CI, 1.80–2.77]) and death (adjusted HR, 1.17 [95% CI, 1.05–1.30]) and rehospitalization (adjusted HR, 1.14 [95% CI, 1.07–1.22]) at 1 year. Bleeding events were also associated with 30-day death (adjusted HR, 3.71 [95% CI, 2.94–4.69]), and with death (adjusted HR, 1.39 [95% CI, 1.23–1.56]) and hospital readmission (adjusted HR, 1.19 [95% CI, 1.11–1.27]) at 1 year. Conclusions: In patients undergoing transcatheter aortic valve replacement in the US, vascular complications and in-hospital bleeding events were common, but rates have declined over time with significant variation in complication rates across hospital sites. Vascular and bleeding complications are both associated with worse short- and long-term clinical outcomes including all-cause mortality. Further innovation to reduce sheath sizes and optimize antithrombotic therapy is necessary to reduce the incidence of these detrimental complications.
Age-Related Differences in the Noninvasive Evaluation for Possible Coronary Artery Disease
Lowenstern, Angela , Hill, C. Larry , Pellikka, Patricia A. , Mehta, Rajendra H. , Cooper, Lawton S. , Hoffmann, Udo , Douglas, Pamela S. , Pellikka, Patricia A , Douglas, Pamela S , Alexander, Karen P. , Alhanti, Brooke , Nanna, Michael G. , Bullock-Palmer, Renée P.

JAMA Cardiology | November 18, 2019 | Volume: 5 | Issue: 2 | Pages: 193

10.1001/jamacardio.2019.4973 Get It

Discordances between predicted and actual risk in obese patients with suspected cardiac ischaemia
Litwin, Sheldon E. , Coles, Adrian , Hill, C. Larry , Pagidipati, Neha J. , Lee, Kerry L. , Pellikka, Patricia A. , Udelson, James E. , Cooper, Lawton S. , Hoffmann, Udo , Douglas, Pamela S. , Pellikka, Patricia A , Douglas, Pamela S , Alhanti, Brooke , Mark, Daniel B. , Tardif, Jean‐Claude

Heart | October 10, 2019 | Volume: 106 | Issue: 4 | Pages: 273-279

10.1136/heartjnl-2018-314503 Get It

Objectives To test the relationship between increasing severity of obesity, calculated risk and observed outcomes. Methods Patients with symptoms suggestive of coronary artery disease (CAD) (n=10 003) were stratified according to body mass index (BMI). We compared risk factors, pooled risk scores and physicians’ perception of risk. Cox regression tested the association between BMI and (1) presence of obstructive CAD and (2) composite clinical endpoints (death, cardiovascular death, unstable angina hospitalisation and myocardial infarction). Results BMI was ≥30 kg/m2 in 48% of patients and ≥35 in 20%. Increasingly obese patients were younger, female and non-smoking but with higher prevalence of hypertension, diabetes, black race and sedentary lifestyle. Pooled risk estimates of CAD were highest in those with mid-range BMI. In contrast, physicians’ estimation of the likelihood of significant CAD based on clinical impression increased progressively with BMI. For a 10% increase in the Diamond-Forrester probability of CAD, the adjusted OR for obstructive CAD was 1.5 (95% CI 1.4 to 1.5) in patients with BMI <35, but only 1.2 (95% CI 1.1 to 1.3) in those with BMI ≥35 (interaction p<0.001). Framingham Risk Score increased across increasing BMI categories. However, there was a strong and consistent inverse relationship between degree of obesity and all three composite clinical endpoints over a median 25 months of follow-up. Conclusions Despite perceptions of higher risk and higher risk scores, increasingly obese patients had obstructive CAD less frequently than predicted and had fewer adverse clinical outcomes. There is a need for risk assessment tools and guidelines that account for obesity. Trial registration number NCT01174550.
Clinical Impact of Diabetes Mellitus on Outcomes After Transcatheter Aortic Valve Replacement
Abramowitz, Yigal, Vemulapalli, Sreekanth , Chakravarty, Tarun , Li, Zhuokai , Holmes, David R. , Wang, Alice , Cheng, Wen , Forrester, James S. , Smalling, Richard W. , Thourani, Vinod H. , Mack, Michael J. , Leon, Martin B. , Makkar, Raj , Douglas, Pamela S. , Matsouaka, Roland A, Smalling, Richard, Thourani, Vinod, Mack, Michael, Leon, Martin, Makkar, Raj R., Douglas, Pamela S , Kapadia, Samir , Matsouaka, Roland

Circulation: Cardiovascular Interventions | November 14, 2017 | Volume: 10 | Issue: 11 | Pages: No page available

10.1161/circinterventions.117.005417 Get It

Background— Diabetes mellitus (DM) adversely affects morbidity and mortality for cardiovascular diseases and procedures. Data evaluating the outcomes of transcatheter aortic valve replacement (TAVR) in diabetic patients are limited by small sample size and contradictory results. We aimed to establish the magnitude of risk and the incremental influence of insulin dependency by examining short- and long-term adverse outcomes according to DM status and therapy in the world’s largest TAVR registry. Methods and Results— We analyzed data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. In-hospital mortality, 30-day mortality, and 1-year mortality after TAVR in patients with and without DM were evaluated using multivariate modeling. Among 47 643 patients treated with TAVR from November 2011 through September 2015 at 394 US hospitals, there were 17 849 (37.5%) patients with DM. Overall, 6600 of the diabetic patients were insulin treated (IT). Thirty-day mortality was 5.0% in patients with DM (6.1% in IT DM and 4.4% in non-IT DM; P <0.001) versus 5.9% in patients without DM ( P <0.001). Overall, 1-year mortality was 21.8% in patients with DM (24.8% in IT DM and 20.1% in non-IT DM; P <0.001) versus 21.2% in patients without DM ( P =0.274). In a multivariable model, DM was associated with increased 1-year mortality (hazard ratio, 1.30; 95% confidence interval, 1.13–1.49; P <0.001). Subgroup multivariable analysis showed stronger mortality association in IT diabetics (hazard ratio, 1.57; 95% confidence interval, 1.28–1.91; P <0.001) than in non-IT diabetics (hazard ratio, 1.17; 95% confidence interval, 1.00–1.38; P =0.052). Conclusions— Our data establish the magnitude of short- and long-term risk conferred by DM and the incremental risk conferred by insulin dependency in the performance of TAVR. Clinical Trial Registration— URL: https://www.clinicaltrials.gov . Unique identifier: NCT01737528.
Impact of Diabetes Mellitus on the Evaluation of Stable Chest Pain Patients: Insights From the PROMISE (Prospective Multicenter Imaging Study for Evaluation of Chest Pain) Trial
Sharma, Abhinav , Sekaran, Nishant K., Coles, Adrian , Pagidipati, Neha J. , Hoffmann, Udo , Lee, Kerry L. , Al‐Khalidi, Hussein R. , Lu, Michael T. , Pellikka, Patricia A. , Truong, Quynh A. , Douglas, Pamela S. , Pellikka, Patricia A , Douglas, Pamela S , Mark, Daniel B.

Journal of the American Heart Association | November 1, 2017 | Volume: 6 | Issue: 11 | Pages: No page available

10.1161/jaha.117.007019 Get It

Background The impact of diabetes mellitus on the clinical presentation and noninvasive test ( NIT ) results among stable outpatients presenting with symptoms suggestive of coronary artery disease ( CAD ) has not been well described. Methods and Results The PROMISE (Prospective Multicenter Imaging Study for Evaluation of Chest Pain) trial enrolled 10 003 patients with known diabetic status, of whom 8966 were tested as randomized and had interpretable NIT results (1908 with diabetes mellitus, 21%). Differences in symptoms and NIT results were evaluated using logistic regression. Patients with diabetes mellitus (versus without) were similar in age (median 61 versus 60 years) and sex (female 54% versus 52%), had a greater burden of cardiovascular comorbidities, and had a similar likelihood of nonchest pain symptoms (29% versus 27%). The Diamond‐Forrester/Coronary Artery Surgery Study score predicted that patients with diabetes mellitus (versus without) had similar likelihood of obstructive CAD (low 1.8% versus 2.7%; intermediate 92.3% versus 92.6%; high 5.9% versus 4.7%). Physicians estimated patients with diabetes mellitus to have a higher likelihood of obstructive CAD (low to very low: 28.3% versus 40.1%; intermediate 63.9% versus 55.9%; high to very high 7.8% versus 4.0%). Patients with diabetes mellitus (versus without) were more likely to have a positive NIT result (15% versus 11%; adjusted odds ratio, 1.23; P =0.01). Conclusions Stable chest pain patients with and without diabetes mellitus have similar presentation and pretest likelihood of obstructive CAD ; however, physicians perceive that patients with diabetes mellitus have a higher pretest likelihood of obstructive CAD , an assessment supported by increased risk of a positive NIT . Further evaluation of diabetes mellitus's influence on CAD assessment is required. Clinical Trial Registration URL : https://www.clinicaltrials.gov . Unique identifier: NCT 01174550.
Peripheral Artery Disease and Transcatheter Aortic Valve Replacement Outcomes
Fanaroff, Alexander C. , Manandhar, Pratik , Holmes, David R. , Harrison, J. Kevin , Thourani, Vinod H. , Mack, Michael J. , Sherwood, Matthew W. , Vemulapalli, Sreekanth , Douglas, Pamela S. , Hughes, G Chad, Jones, W Schuyler, Douglas, Pamela S , Cohen, David Jonathan , Hughes, George Chad , Jones, W. Schuyler , Fanaroff, Alexander C

Circulation: Cardiovascular Interventions | October 17, 2017 | Volume: 10 | Issue: 10 | Pages: No page available

10.1161/circinterventions.117.005456 Get It

Background— Peripheral artery disease (PAD) is associated with increased cardiovascular mortality, and PAD risk factors overlap with those for aortic stenosis. The prevalence and outcomes associated with PAD in a population undergoing transcatheter aortic valve replacement (TAVR) are unknown. Methods and Results— Using the Society of Thoracic Surgeons/Transcatheter Valve Therapy Registry linked to Medicare claims data, we identified patients ≥65 years old undergoing TAVR from 2011 to 2015. We calculated hazard ratios for 1-year adverse outcomes, including mortality, readmission, and bleeding, for patients with PAD compared with those without, adjusting for baseline characteristics and postprocedure medications. Analyses were performed separately by access site (transfemoral and nontransfemoral). Of 19 660 patients undergoing transfemoral TAVR, 4810 (24.5%) had PAD; 3730 (47.9%) of 7780 patients undergoing nontransfemoral TAVR had PAD. In both groups, patients with PAD were significantly more likely to have coronary and carotid artery diseases. At 1-year follow-up, patients with PAD undergoing TAVR via transfemoral access had a higher incidence of death (16.8% versus 14.4%; adjusted hazard ratio, 1.14; P =0.01), readmission (45.5% versus 42.1%; hazard ratio, 1.11; P <0.001), and bleeding (23.1% versus 19.7%; hazard ratio, 1.18; P <0.001) compared with patients without PAD. Patients with PAD undergoing TAVR via nontransfemoral access did not have significantly higher rates of 1-year mortality or readmission compared with patients without PAD. Conclusions— PAD is common among patients undergoing commercial TAVR via transfemoral and nontransfemoral access. Among patients undergoing transfemoral TAVR, PAD is associated with a higher incidence of 1-year adverse outcomes compared with absence of PAD. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT01737528.
Educational intervention for improving the appropriateness of transthoracic echocardiograms ordered by pediatric cardiologists
Sachdeva, Ritu , Douglas, Pamela S. , McCracken, Courtney , Lopez, Leo , Stern, Kenan W.D. , Eidem, Benjamin W., Benavidez, Oscar J., Weiner, Rory B., Welch, Elizabeth , Campbell, Robert M. , Kelleman, Michael Scott , Lai, Wyman W. , Douglas, Pamela S

Congenital Heart Disease | February 22, 2017 | Volume: 12 | Issue: 3 | Pages: 373-381

10.1111/chd.12455 Get It

Application of pediatric appropriate use criteria for initial outpatient evaluation of syncope
Phelps, Heather M. , McCracken, Courtney , Benavidez, Oscar J., Campbell, Robert M. , Douglas, Pamela S. , Eidem, Benjamin W., Lopez, Leo , Stern, Kenan W.D. , Welch, Elizabeth , Sachdeva, Ritu , Kelleman, Michael Scott , Lai, Wyman W. , Douglas, Pamela S

Echocardiography | February 8, 2017 | Volume: 34 | Issue: 3 | Pages: 441-445

10.1111/echo.13475 Get It

BackgroundSyncope is a common reason for outpatient transthoracic echocardiography (TTE). We studied the applicability of pediatric appropriate use criteria (AUC) on initial outpatient evaluation of children (≤18 years) with syncope.MethodsData were obtained before (Phase I, April–September 2014) and after (Phase II, January‐April 2015) the release of the AUC document from six participating pediatric cardiology centers. Site investigators determined the indication for TTE and assigned appropriateness rating based on the AUC document: Appropriate (A), May Be Appropriate (M), Rarely Appropriate (R), or “unclassifiable” (U) if it did not fit any scenario in the AUC document.ResultsOf the total 4562 TTEs, 310 (6.8%) were performed for syncope: 174/2655 (6.6%) Phase I and 136/1907 (7.1%) Phase II, P=.44. Overall, 168 (50.5%) were for indications rated A, 63 (18.9%) for M, 79 (23.7%) for R, and 23 (6.9%) for U. Release of AUC did not change the appropriateness of TTEs [A=51.6% vs 49.0%, P=.63, R=20.2% vs 28.3%, P=.09]. Overall syncope‐related R indications formed 15.7% of R indications for all the echocardiograms performed in the entire Pediatric Appropriate Use (PAUSE) study (11.9% Phase I and 22.4% Phase II, P=.002). TTEs were normal in majority of the patients except 7 that had incidental findings.ConclusionsIn conclusion, syncope is a common reason for indications rated R and release of the AUC document did not improve appropriate utilization of TTE in syncope. Targeted educational interventions are needed to reduce unnecessary TTEs in children with syncope.