Back to Authors

Nkomo, Vuyisile T.

https://orcid.org/0000-0001-6095-5579

Mayo Clinic

Mayo Clinic

Citations 158

The MIDA Mortality Risk Score: development and external validation of a prognostic model for early and late death in degenerative mitral regurgitation
Grigioni, Francesco , Clavel, Marie‐Annick , Tribouilloy, Christophe, Pizarro, Rodolfo , Huebner, Marianne , Aviérinos, Jean-François , Barbieri, Andréa , Suri, Rakesh M. , Ruşinaru, Dan, Gargiulo, Gaetano , Oberti, Pablo , Bursi, Francesca , Lazam, Siham, Szymanski, Catherine, Reggiani, Maria Letizia Bacchi , Enriquez‐Sarano, Maurice , Investigators, MIDA, Tribouilloy, C, Trojette, F, Szymanski, C., Touati, Gilles, Remadi, J.-P., Pasquale, F, Ferlito, Marinella, Rapezzi, C., Boulif, Jamila, Meester, Christophe de , Khoury, Gébrine El , Lazam, S, Noirhomme, Philippe, Vanoverschelde, J-L, Collard, F., Lugli, R. , Maalouf, Joseph F., Nkomo, Vuyisile T, Michelena, Hector, Vanoverschelde, Jean‐Louis , Tribouilloy, Christophe , Pasquet, Agnès , Théron, Alexis , Michelena, Héctor I. , Nkomo, Vuyisile T. , Schumacher, Martin Christian , Investigators, MIDA, Trojette, Faouzi, Russo, Antonio , Biagini, Elena , Savini, Carlo , Marinelli, Giuseppe , Pacini, Davide , Bartolomeo, Roberto Di , Corazza, Ivan , Gerber, Bernhard , Vancraeynest, David , Vanoverschelde, J-L, Habib, Gilbert , Mantovani, Francesca , Modena, Maria Grazia , Boriani, Giuseppe , Nkomo, Vuyisile T, Enriquez-Sarano, Maurice , Barbieri, Andrea , Clavel, Marie-Annick , Bursi, Francesca , Grigioni, Francesco

European Heart Journal | July 24, 2017 | Volume: 39 | Issue: 15 | Pages: 1281-1291

10.1093/eurheartj/ehx465 Get It

Morbidity and Mortality Associated With Balloon Aortic Valvuloplasty
Zack, Chad, Sarraf, Mohammad , Bashir, Riyaz , Nishimura, Rick A., Eleid, Mackram F. , Sandhu, Gurpreet S. , Gulati, Rajiv , Greason, Kevin L. , Holmes, David R. , Rihal, Charanjit S. , Zack, Chad J, Alkhouli, Mohamad , Nkomo, Vuyisile T. , Rihal, Charanjit S.

Circulation: Cardiovascular Interventions | May 12, 2017 | Volume: 10 | Issue: 5 | Pages: No page available

10.1161/circinterventions.116.004481 Get It

Background— The introduction of transcatheter aortic valve replacement (TAVR) led to renewed interest in balloon aortic valvuloplasty (BAV). We sought to assess contemporary trends in BAV utilization and their outcomes. Methods and Results— The Nationwide Inpatient Sample was used to identify patients who underwent BAV between 2004 and 2013. In-hospital morbidity and mortality, and predictors of death after BAV were assessed. Outcomes of propensity-matched groups of patients undergoing elective BAV or TAVR were evaluated. BAV utilization increased from 707 cases in 2004 to 3715 cases in 2013 (national estimates). Procedural and in-hospital mortality were 1.4% and 8.5%, respectively. Vascular complications occurred in 7.0% of cases, blood transfusion in 17.5%, clinical stroke in 1.8%, and pacemaker implantation in 3.0%. The strongest predictors of in-hospital death were cardiogenic shock (odds ratio, 6.01; 95% confidence interval, 4.19–8.61; P <0.001), need for left ventricular assist device (odds ratio, 3.48; 95% confidence interval, 2.25–5.36; P <0.001), coagulopathy (odds ratio, 2.19; 95% confidence interval, 1.51–3.18; P <0.001), and low institutional volume of BAV (odds ratio, 1.58; 95% confidence interval, 1.06–2.37; P =0.03). In propensity-matched patients undergoing elective BAV or TAVR, rates of in-hospital mortality (2.9% versus 3.5%; P =0.60), clinical stroke (1.6% versus 3.1%; P =0.10), and vascular complications (8.2% versus 10.9%; P =0.14) were similar. However, BAV was associated with lower rates of pacemaker implantation (2.9% versus 8.0%; P <0.001) and blood transfusion (12.8% versus 22.9%; P <0.001). Conclusions— In a contemporary national registry, BAV is associated with significant morbidity and mortality that are similar to TAVR. With the substantial increase in BAV utilization and the continuous improvement in TAVR outcomes, these data have important implications to aid clinicians in the selection of appropriate BAV candidates.
Frequency, Predictors, and Implications of Abnormal Blood Pressure Responses During Dobutamine Stress Echocardiography
Abram, S.E., Arruda‐Olson, Adelaide M. , Pellikka, Patricia A. , Oh, Jae K. , Milan, Alberto , Abidian, Mohamed Modar , McCully, Robert B. , Abram, Sara, Abidian, Mohamed M, Scott, Christopher G. , Nkomo, Vuyisile T. , Pellikka, Patricia A

Circulation: Cardiovascular Imaging | March 28, 2017 | Volume: 10 | Issue: 4 | Pages: No page available

10.1161/circimaging.116.005444 Get It

Background— It is not known whether abnormal blood pressure (BP) responses during dobutamine stress echocardiography (DSE) are associated with abnormal test results, nor if such results indicate obstructive coronary artery disease (CAD). We sought to define the frequency of abnormal BP responses during DSE and their impact on accuracy of test results. Methods and Results— We studied 21 949 patients who underwent DSE at Mayo Clinic, Rochester, MN, grouped by peak systolic BP achieved during the test. We also analyzed a subgroup who underwent coronary angiography within 30 days after positive DSE. The positive predictive value of DSE was calculated for each BP group. Patients with hypertensive response (n=1905; 9%) were more likely to have positive DSE than those with normal (n=19 770; 90%) or hypotensive (n=274; 1%) BP responses (32% versus 21% versus 23%, respectively; P <0.0001). Angiography, performed in 1126 patients, showed obstructive CAD (≥50% stenosis) in 814 patients and severe CAD (≥70% stenosis) in 708 patients. Positive predictive value of DSE was similar for patients who had hypertensive and normal BP responses (69% versus 73%; P =0.3), considering 50% stenosis cut point. The proportion of severe CAD (≥70% stenosis) was lower in patients who had hypertensive response compared with those who had normal BP response (54% versus 65%; P =0.005). Conclusions— Patients with hypertensive response during DSE are more likely to have stress-induced myocardial ischemia compared with those with normal or hypotensive BP responses but are not more likely to have false-positive DSE results. They are, however, less likely to have higher grade or multivessel CAD.
Acute Changes in Left Atrial Pressure After MitraClip Are Associated With Improvement in 6-Minute Walk Distance
Maor, Elad , Panaich, Sidakpal , Reeder, Guy S., Nishimura, Rick A., Rihal, Charanjit S. , Eleid, Mackram F. , Raphael, Claire E. , Panaich, Sidakpal S, Nkomo, Vuyisile T. , Rihal, Charanjit S. , Panaich, Sidakpal S , Maor, Elad

Circulation: Cardiovascular Interventions | March 18, 2017 | Volume: 10 | Issue: 4 | Pages: No page available

10.1161/circinterventions.116.004856 Get It

Background— Data on the clinical use of left atrial (LA) hemodynamic monitoring during MitraClip procedure are limited. This study evaluated the association between intraprocedural changes in LA pressure after MitraClip and improvement in exercise capacity as documented by 6-minute walk test (6MWT). Methods and Results— Study population included 50 patients who underwent MitraClip at the Mayo Clinic (Rochester, MN), between June 2014 and July 2016 and completed both baseline and 30-day follow-up 6MWT. Primary outcome for the current analysis was defined as 6MWT improvement above the median. Mean age of the study population was 79±10 years, and 34 (68%) were men. Baseline preprocedural 6MWT distance was 308 m (interquartile range [IQR], 234–394 m). Acute, intraprocedural change in LA pressure after MitraClip was 3 mm Hg (IQR, 1–6 mm Hg), and change in V wave was 11 mm Hg (IQR, 6–19 mm Hg). Median 6MWT improvement was 25 m (IQR, 19–47 m). Univariate analysis showed that patients with ≤ mild postprocedural mitral regurgitation were 4-fold more likely to experience an improvement in 6MWT ( P =0.02). Multivariate model demonstrated that each 5 mm Hg decrease in V wave was associated with 49% increased likelihood for improvement in 6-minute walk ( P =0.04). Similar model with V-wave change as a dichotomous variable showed that patients with a V-wave decrease of ≥11 mm Hg were 3.8× more likely to improve their 6MWT ( P =0.05). Conclusions— Acute changes in LA pressure after MitraClip procedure are associated with clinical improvement as measured by 6MWT. Continuous LA pressure monitoring may be a useful tool for procedural guidance during transcatheter mitral repair.
Characteristics and outcomes of re‐do percutaneous paravalvular leak closure
Al‐Hijji, Mohammed , Sarraf, Mohammad , Zack, Chad, Malouf, Joseph F., Reeder, Guy S., Rihal, Charanjit S. , Eleid, Mackram F. , Al-Hijji, Mohammed A , Zack, Chad J, Cabalka, Allison K. , Alkhouli, Mohamad , Nkomo, Vuyisile T. , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | February 10, 2017 | Volume: 90 | Issue: 4 | Pages: 680-689

10.1002/ccd.26961 Get It

BackgroundPercutaneous paravalvular leak (PVL) closure is an alternative treatment option for severely symptomatic, high‐surgical risk patients with PVL. Some patients require multiple percutaneous PVL closure procedures. However, the procedural characteristics and success rate of re‐do PVL closure have not been well studied.AimsThe aim of this study is to investigate the indications, procedural characteristics, technical success rate, and 30‐day major adverse cardiovascular events (MACE) in patients who underwent re‐do PVL closure.MethodsConsecutive patients who underwent percutaneous paramitral or paraaortic leak closure at Mayo Clinic, Rochester, Minnesota from 2004 through 2015 were studied. Clinical and procedural characteristics of patients who underwent re‐do PVL closure were compared to age‐ and sex‐matched patients who underwent their first percutaneous PVL closure. Procedure success and 30‐day MACE were compared in both the groups.ResultsAmong 223 identified percutaneous PVL closures, 16 (7%) were re‐do procedures. Patients who underwent re‐do PVL closure were predominantly men (87.5%) with a mean age of 68 ± 15 years and an estimated mean Society of Thoracic Surgery (STS) 30‐day mortality of 4.6 ± 2.8. Half of the re‐do PVL closures were performed on mechanical valves and 62.5% were performed on paramitral defects. Indications for re‐do PVL closure were: (1) emergence of new significant paravalvular defects in 50%, (2) incomplete index defect closure in 43.75%, and (3) index procedural complication in 6.25% of the cases. Procedural success was 75% in re‐do procedures vs. 85.4% in age‐ and sex‐matched control group (P = 0.45). Thirty‐day MACE was 12.5% in the re‐do group compared to 4.2% in the age‐ and‐sex matched patients who underwent PVL closure for the first time (P = 0.35).ConclusionRe‐do percutaneous PVL closure is feasible with favorable procedural success rate and low 30‐day MACE. Development of new paravalvular defects is the most common indication for re‐do PVL closure, highlighting the importance of careful longitudinal monitoring and follow‐up. © 2017 Wiley Periodicals, Inc.
Outcomes of Transvenous Lead Extraction for Cardiovascular Implantable Electronic Device Infections in Patients With Prosthetic Heart Valves
Huang, Xin-Miao, Fu, Hai-xia, Zhong, Li , Cao, Jiang, Asirvatham, Samuel J. , Sohail, M. Rizwan , Nishimura, Rick A., Greason, Kevin L. , Suri, Rakesh M. , Friedman, Paul A. , Cha, Yong‐Mei , Baddour, Larry M. , Nkomo, Vuyisile T. , Suri, Rakesh M. , Asirvatham, Samuel J , Sohail, M Rizwan

Circulation: Arrhythmia and Electrophysiology | September 15, 2016 | Volume: 9 | Issue: 9 | Pages: No page available

10.1161/circep.116.004188 Get It

Background— Lead-related or valve-related endocarditis can complicate cardiovascular implantable electronic device (CIED) infection in patients with both CIED and prosthetic valves. The objective of this study was to determine the outcomes of transvenous lead extraction for CIED infection in patients with prosthetic valves. Methods and Results— We retrospectively screened 794 transvenous lead extraction procedures, between September 1, 2001 and August 31, 2012, at Mayo Clinic to identify patients with prosthetic valves who underwent lead extraction for infection. Demographic, clinical, and follow-up characteristics were analyzed. In total, 51 patients (6%) met the study inclusion criteria, of whom 20 had pocket infection and 31 had lead-related or valve-related, or both, endocarditis or bloodstream infection (mean age, 67 [18] years). Staphylococcal species were the most common pathogens, including Staphylococcus aureus in 20 cases (39%) and coagulase-negative staphylococci in 19 cases (37%). Overall, 127 transvenous leads (median lead age, 52 months) were extracted. Of these leads, 123 (97%) were removed completely. The in-hospital mortality rate was 9.8%; no deaths were attributable to the extraction procedure. Ninety-five percent of patients who survived had no evidence of recurrent device-related or valve-related infection. Conclusions— Transvenous lead extraction seems safe and curative in patients with CIED infection and prosthetic valves. Cure of infection can be achieved in the majority of patients with complete CIED removal and antimicrobial therapy and without valve surgery.
The Learning Curve for Transcatheter Mitral Valve Repair With MitraClip
Eleid, Mackram F. , Reeder, Guy S., Malouf, Joseph F., Lennon, Ryan J. , Pislaru, Sorin V. , Nkomo, Vuyisille T., Rihal, Charanjit S. , Nkomo, Vuyisile T. , Rihal, Charanjit S. , Sabbah, Michael S.

Journal of Interventional Cardiology | July 28, 2016 | Volume: 29 | Issue: 5 | Pages: 539-545

10.1111/joic.12326 Get It

ObjectivesThis study sought to assess the learning curve for TMVR for treatment of primary mitral regurgitation (MR).BackgroundData are lacking regarding the technical experience required to achieve optimal clinical outcomes with transcatheter mitral valve repair (TMVR) using the edge‐to‐edge MitraClip technique.MethodsWe examined the sequential experience of the first 75 patients (age 80 ± 9 years; 77% male) who underwent TMVR at our institution. A sequence number of each patient was assigned as a continuous variable and in tertiles for analysis.ResultsTMVR with MitraClip was successful in 97% with an average procedural time of 106 ± 39 minutes. The 30‐day rate of major adverse cardiovascular events was 7%. With increased case experience, there were decreases in procedural time, fluoroscopy time, length of hospital stay, and major adverse cardiovascular events. Procedural success, residual mitral regurgitation and NYHA functional classification at 30‐day follow‐up remained unchanged throughout the experience.ConclusionsThe learning curve for TMVR with MitraClip for treatment of primary MR is characterized by a sequential reduction in procedure time, fluoroscopy time, procedural complications, and hospital length of stay at a tertiary academic medical center. Thirty‐day procedural results are favorable and similar during the initial learning period.
Assisted care as a baseline patient risk characteristic affecting the outcome of transcatheter aortic valve insertion
Traynor, Megan M. , Greason, Kevin L. , Pochettino, Alberto , Holmes, David R. , Rihal, Charanjit S. , Reeder, Guy S., Bresnahan, John F., Mathew, Verghese, Nkomo, Vuyisile T. , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | June 8, 2016 | Volume: 89 | Issue: 7 | Pages: 1268-1272

10.1002/ccd.26580 Get It

BackgroundObjective measures of frailty have not been well defined as risk factors for a poor outcome after transcatheter aortic valve insertion. We hypothesized that assisted care as a baseline patient characteristic was a simple objective measure of frailty. We reviewed our experience to assess for an association between assisted care and outcome of operation.MethodsWe retrospectively reviewed the records of 597 patients operated with transcatheter aortic valve insertion from November 2008 through July 2015. The study cohort included patients with a dichotomous baseline characteristic of receiving assisted care (AC group, n = 60, 10.1%) or not receiving assisted care (NC group, n = 537, 89.9%). The endpoints of the study were operative stroke/death and 1‐year survival.ResultsThe age of the patients was 80.6 ± 9.0 years, male sex was present in 349 (58.5%), and STS predicted risk of mortality was 9.2 ± 6.2%. Alternate access was used in 26 (43.3%) patients in the AC care group and in 220 (41.0%) in the NC group (P = 0.724). Operative stroke/death occurred in 4 (6.7%) patients in the AC group and in 25 (4.7%) in the NC group (P = 0.492). Mortality at 1 year in the AC group was 14.8 ± 5.2% and in the NC group was 12.9 ± 1.7%; (P = 0. 250).ConclusionsAssisted care as a baseline patient characteristic does not result in increased operative stroke/death or 1‐year mortality in patients following transcatheter aortic valve insertion. Assisted care should not by itself preclude operation. © 2016 Wiley Periodicals, Inc.
Acute LVOT Obstruction with a Carbomedics Mechanical Valve Prosthesis
Joyce, David L. , Malouf, Joseph F., Alsidawi, Said , Nkomo, Vuyisile T.

Journal of Cardiac Surgery | April 18, 2016 | Volume: 31 | Issue: 6 | Pages: 376-379

10.1111/jocs.12749 Get It

Sex-Specific Differences at Presentation and Outcomes Among Patients Undergoing Transcatheter Aortic Valve Replacement
Kodali, Susheel , Williams, Mathew , Doshi, Darshan , Hahn, Rebecca T. , Humphries, Karin H. , Douglas, Pamela S. , Mack, Michael J. , Xu, Ke , Svensson, Lars G. , Thourani, Vinod H. , Tuzcu, E. Murat , Weissman, Neil J., Leon, Martin B. , Kirtane, Ajay J. , Hahn, Rebecca T , Nkomo, Vuyisile T. , Cohen, David Jonathan , Douglas, Pamela S , Williams, Mathew

Annals of Internal Medicine | February 22, 2016 | Volume: 164 | Issue: 6 | Pages: 377

10.7326/m15-0121 Get It