Cardiac vasoplegia remains a significant contributor of morbidity and mortality in cardiac surgery patients after cardiopulmonary bypass. Effective therapeutic options for vasopressor-refractory vasoplegia are limited. We report 3 patients in whom we administered high-dose intravenous ascorbic acid (vitamin C), a cofactor for endogenous catecholamine synthesis, to treat vasoplegia refractory to epinephrine, vasopressin, and norepinephrine after surgery requiring cardiopulmonary bypass. Reductions in vasopressor requirements were observed in all 3 patients, and, in 2 patients, norepinephrine was completely discontinued within 24 hours. Ascorbic acid is a novel potential therapeutic option for cardiac vasoplegia that warrants rigorous prospective studies.
Clinical presentation and outcome of tricuspid regurgitation in patients with systolic dysfunction
Hydroxocobalamin (vitamin B12a) is an emerging treatment for vasoplegic syndrome (VS) associated with cardiopulmonary bypass (CPB). Given its cost and scarcity, an institutional guideline for its use as a rescue treatment in cases of suspected VS was developed. Hemodynamic variables and vasopressor requirements were reviewed for a series of 24 post-CPB patients who received B12a. Favorable changes in hemodynamic parameters and vasopressor requirements were seen after B12a administration although guideline criteria for VS were inconsistently met. These findings support the continued study of B12a in patients with CPB-associated VS.
Pump Position Impacts HeartMate II Left Ventricular Assist Device Thrombosis
The PREVENtion of HeartMate II pump Thrombosis through clinical management (PREVENT) study was a multicenter, prospective investigation to evaluate the rate of pump thrombosis (PT) with adoption of a uniform set of surgical and medical practices for left ventricular assist device implantation. We sought to quantify pump position at baseline and retrospectively define a pump position associated with poor clinical outcomes. Chest x-rays at baseline were prospectively obtained per protocol. Pump pocket depth, inflow cannula (IC) angle relative to the pump, and IC angle relative to the vertical were measured. Pumps falling in the tail-ends of the IC angle and pump pocket depth distributions were categorized as having an extreme pump position within the PREVENT study. Patients with extreme pump position had a significantly higher risk of confirmed and suspected PT, hemolysis, and elevated lactate dehydrogenase. In a multivariable analysis of survival free of confirmed PT, extreme pump position was an independent risk factor (hazard ratio = 3.6; 95% confidence interval = 1.5–8.9; p = 0.006) when adjusting for differences in pump speed and anticoagulation level. Our analysis shows that HeartMate II pump position at implant can significantly impact event-free survival and the incidence of adverse events at 6 months.
Medical Therapy As Compared To Surgical Device Exchange for Left Ventricular Assist Device Thrombosis: A Systematic Review and Meta-Analysis
Pump thrombosis is a major adverse event in patients supported on continuous-flow left ventricular assist devices (CF-LVAD). The aim of this systematic review and meta-analysis was to determine the outcomes of various treatment approaches for pump thrombosis, including surgical as compared to medical therapy. Electronic search was performed to identify all studies in the English literature addressing surgical and medical management of pump thrombosis in the modern CF-LVAD era. All identified articles were systematically assessed for inclusion and exclusion criteria. In the meta-analysis, because of significant overlap of the data, reports based on trials, registries, and individual cohort studies were analyzed separately. Forty-three studies were included in the analysis (2 trials, 4 registry reports, and 37 individual cohort studies). 2,281/28,728 (10.6%) patients developed pump thrombosis, of which 44.4% and 55.1% were supported on the HeartWare and HeartMate II, respectively. To avoid overlap in studies and to seek more granular data, pooled individual cohort studies were found to be representative of the entire population, and further in-depth analysis of this category was performed. Of the 610/5,545 (11.8%) patients with pump thrombosis in these individual cohort studies, 225 patients had surgical pump exchange, and 186 were treated medically. Surgical therapy resulted in higher success as compared to medical therapy (81.3% vs. 45.4%; p < 0.001), lower 30 day mortality rate (16.7% vs. 34.5%; p = 0.013) and recurrence rate (11.8% vs. 38.3%; p < 0.001). Meta-regression of all studies demonstrates a possible temporal increase of pump thrombosis rate (p = 0.040). Surgical pump exchange is superior to medical therapy with a higher success rate of pump thrombosis resolution, lower mortality rate, and lower recurrence rate. Randomized controlled prospective studies are needed to compare these clinical approaches and their resultant outcomes to guide decision-making for the management of CF-LVAD thrombosis.
Noninvasive Blood Pressure Monitor Designed for Patients With Heart Failure Supported with Continuous-Flow Left Ventricular Assist Devices
The gold standard for noninvasive blood pressure (BP) measurement, the Doppler technique, does not provide systolic blood pressure (SBP) and diastolic blood pressure (DBP) and may limit therapy outcomes. To improve patient care, we tested specifically designed experimental BP (ExpBP) monitor and the Doppler technique by comparing noninvasive measures to the intraarterial (I-A) BP in 31 patients with end-stage heart failure (4 females) 2.6 ± 3.4 days post-LVAD implantation (20 HeartMate II and 11 HeartWare). Bland–Altman plots revealed that the ExpBP monitor overestimated mean arterial pressure (MAP) by 1.2 (4.8) mm Hg (mean difference [standard deviation]), whereas the Doppler by 6.7 (5.8) mm Hg. The ExpBP SBP was overestimated by 0.8 (6.1) mm Hg and DBP by 1.9 (5.3) mm Hg compared with the respective I-A pressures. Both techniques achieved similar measurement reliability. In the measurement “success rate” expressed as a frequency (percent) of readable BP values per measurement attempts, Doppler accomplished 100% vs. 97%, 97%, and 94% of successful detections of MAP, SBP, and DBP provided by the ExpBP monitor. The ExpBP monitor demonstrated higher accuracy in the MAP assessment than the Doppler in addition to providing SBP and DBP in majority of subjects. Improved BP control may help to mitigate related neurologic adverse event rates.
Impact of Diabetes Mellitus on Outcomes in Patients Supported With Left Ventricular Assist Devices
Background Diabetes mellitus (DM) is a risk factor for morbidity and mortality in patients with heart failure. The effect of DM on post–left ventricular assist device (LVAD) implantation outcomes is unclear. This study sought to investigate whether patients with DM had worse outcomes than patients without DM after LVAD implantation and whether LVAD support resulted in a better control of DM. Methods and Results We retrospectively reviewed 341 consecutive adults who underwent implantation of LVAD from 2007 to 2016. Patient characteristics and adverse events were studied and compared between patients with and without DM. One hundred thirty-one patients (38%) had DM. Compared with patients without DM, those with DM had higher rates of ischemic cardiomyopathy, LVAD implantation as destination therapy, and increased baseline body mass index. In a proportional hazards (Cox) model with adjustment for relevant covariates and median follow-up of 16.1 months, DM was associated with increased risk of all-cause mortality (hazard ratio, 1.73; 95% confidence interval: 1.18–2.53; P =0.005) and increased risk of nonfatal LVAD-related complications, including a composite of stroke, pump thrombosis, and device infection (hazard ratio, 2.1; 95% confidence interval: 1.35–3.18; P =0.001). Preoperative hemoglobin A1c was not significantly associated with mortality or adverse events among patients with DM. LVAD implantation resulted in a remarkable decrease in hemoglobin A1c levels (7.4±1.9 pre-LVAD versus 6.0±1.5 and 6.3±1.4 after 3 and 12 months post-LVAD, respectively; P <0.0001) and a significant reduction in requirements of DM medications. Conclusions DM is associated with increased rates of all-cause mortality and major adverse events despite favorable glycemic control after LVAD implantation.
Letter by Maltais et al Regarding Article, “Hemocompatibility-Related Outcomes in the MOMENTUM 3 Trial at 6 Months: A Randomized Controlled Study of a Fully Magnetically Levitated Pump in Advanced Heart Failure”
Left Lateral Thoracotomy for Centrifugal Continuous-Flow Left Ventricular Assist Device Placement: An Analysis from the Mechanical Circulatory Support Research Network
Continuous-flow left ventricular assist devices (CF-LVADs) have revolutionized the management of patients with advanced heart failure. Alternative implant strategies are increasingly used for device placement. We reviewed our experience from the Mechanical Circulatory Support Research Network registry with the HeartWare centrifugal CF-LVAD (HVAD). From May 2004 to August 2015, 1,150 patients underwent primary CF-LVAD implantation at our institutions. Within this group, a total of 283 patients (25%) were implanted with the HVAD. A minimally invasive left lateral thoracotomy (MILT) implant strategy was used in 53 patients (20%), of which 22 (42%) were implanted off-pump. Median age at implant was 59 years and 183 patients (65%) were implanted as bridge-to-transplantation. Follow-up was 100% complete for a total of 302 patient-years of support. In-hospital mortality was 4.9% (14 patients), and was comparable between the conventional sternotomy (CS) and MILT cohorts (p = 0.15). Patients in the MILT cohort had a shorter median length of stay (p < 0.01) and had a lower incidence of postimplant pump thrombus (p = 0.02). Cumulative survival at the end of follow-up reached 84%, and was comparable between the two groups (p = 0.298). Multivariate analysis identified preoperative bilirubin level as the only independent predictor of survival. Surgical technique had no impact on survival. In this large, multicenter experience, data demonstrate excellent survival and adverse event profiles for patients supported with the HVAD technology, regardless of surgical implant technique. With constant advancements in device technology along with our increasing clinical experience with the newer techniques, minimally invasive LVAD implantation continues to evolve as a valuable alternative to CS in selected patients.
Atrial Fibrillation Should Guide Prophylactic Tricuspid Procedures During Left Ventricular Assist Device Implantation
Atrial fibrillation (AF) and tricuspid regurgitation (TR) are common in patients undergoing left ventricular assist device (LVAD) implantation. TR progression is associated with the presence of AF, and questions remain as to who benefits from tricuspid valve procedures (TVPs). We examined the impact of preoperative AF on TR progression after LVAD implantation. From February 2007 to May 2014, 250 patients underwent LVAD implantation at our institution. Patients with concomitant TVP were excluded from this analysis (113 patients). The indication for LVAD was destination therapy in 80 patients (58%) and the etiology of heart failure was ischemic in 73 (53%). Follow-up was available in all early survivors for a total of 393 patient-years of support. Of the 137 non-TVP patients, 52 (38%) had AF preoperatively. Observed overall survival at 1, 3, and 5 years was 82%, 67%, and 55%, respectively. Median grade of TR increased from 2 preoperatively to 3 (p = 0.04) in the AF group and 2.2 (p = 0.75) in the non-AF group at 5 years of follow-up. We also observed a significant difference in the degree of TR between groups at 3 months (p = 0.03) and 12 months (p = 0.01) postimplantation, and a trend toward significance at 18 (p = 0.06) and 24 (p = 0.07) months. The presence of AF is associated with early progression of TR after LVAD implantation. Addition of concomitant TVP in patients with preoperative AF may be considered in patients with less than severe TR. The impact of these findings on right ventricular failure/remodeling remains to be evaluated.