Abstract Aims The increasing adoption of transcatheter tricuspid valve replacement (TTVR) offers a promising therapeutic option for patients with severe tricuspid regurgitation. However, many of these patients have pre-existing cardiac implantable electronic devices (CIEDs), raising concerns about potential lead-related complications. Despite these concerns, limited data exist on the impact of TTVR on CIED integrity and function. This study aimed to evaluate the impact of TTVR on CIED lead function, including pacing thresholds, sensing, and impedance, in patients undergoing TTVR with the EVOQUE valve system. Methods and results A retrospective observational study was conducted at Mayo Clinic Rochester, including 32 consecutive patients who underwent TTVR with pre-existing CIEDs. A total of 32 patients were included, with a mean age of 79.2 ± 8.4 years; 59% were female. A total of 62.5% had a permanent pacemaker, 12.5% had an implantable cardioverter-defibrillator, 15.6% had a cardiac resynchronization therapy pacemaker, and 9.4% had a cardiac resynchronization therapy defibrillator. Following TTVR, 10 (31%) of patients developed lead function changes during a median device follow-up of 210 days (IQR: 43–307 days). The right ventricular lead was primarily affected, with only one case involving an atrial lead. Neither the Ottawa score nor the anatomical lead position reliably predicted lead abnormality (P = 0.86 and P = 0.53, respectively). R-wave sensing changes were the most common lead change observed, affecting 55% of cases. In 67% of these cases, R-wave sensing alterations occurred as an isolated finding, with no significant change in impedance or thresholds, and were managed conservatively without any need for device reprogramming. Four patients (13%) had findings concerning for a lead insulation breach, in which one (3%) required a lead revision. Among five patients with follow-up exceeding 600 days, two patients exhibited a statistically significant gradual decline in impedance without other lead dysfunction, suggesting potential subclinical lead degradation. Conclusion Transcatheter tricuspid valve replacement with the EVOQUE system in the setting of cardiac device leads is associated with lead function changes in 31%. The majority of lead-related changes were managed conservatively, but 13% of patients had findings concerning for an insulation breach. Future studies should focus on refining implantation techniques and defining optimal strategies for managing device-lead interactions in this population.
Atrioventricular node ablation for refractory atrial fibrillation in patients with hypertrophic cardiomyopathy: a case–control study
Background Atrial dysfunction is a risk factor for atrial arrhythmia and can be detected by atrial strain imaging in patients with biventricular circulation. However, the role of atrial strain imaging for risk stratification of atrial arrhythmia in patients with Fontan palliation has not been studied, despite the high prevalence and prognostic implications of atrial arrhythmia in this population. We hypothesized that pulmonary venous atrial strain was associated with new‐onset and recurrent atrial arrhythmia in Fontan physiology. Method and Results This is a retrospective study of adults with Fontan palliation and no prior history of atrial arrhythmia who underwent atrial strain imaging by speckle tracking echocardiography (2003–2023). New‐onset and recurrent atrial arrhythmias were ascertained from baseline encounter to last follow‐up. Of 404 patients, atrial reservoir strain assessment was feasible in 329 patients (81%), with modest intra‐ and interobserver agreement. The median atrial reservoir strain was 18% (interquartile range, 13%–24%), and atrial dysfunction (atrial reservoir strain <28%) was present in 294 (89%). Atrial reservoir strain <15% was associated with new‐onset atrial arrhythmia (adjusted hazard ratio [HR], 1.59 [95% CI, 1.09–2.34]; P =0.009), and recurrent atrial arrhythmia (adjusted HR, 2.01 [95% CI, 1.06–3.93]; P =0.003). Rhythm control therapy was associated with lower risk of recurrence compared with rate control therapy (adjusted HR, 0.92 [95% CI, 0.86–0.98]; P =0.003). Conclusions Atrial dysfunction was common and was associated with new‐onset and recurrent atrial arrhythmias. The higher prevalence of atrial arrhythmias in patients with reduced atrial strain and the apparent protective effect of rhythm control therapy suggest that rhythm control therapy may be the preferred treatment in patients with reduced atrial strain.
Outcomes in Patients With Mitral Annular Disjunction and an Implantable‐Cardioverter Defibrillator
ABSTRACT Background Mitral annular disjunction (MAD) carries an increased risk of complex ventricular arrhythmias, which can lead to sudden cardiac death. Many of these patients undergo implantable cardioverter defibrillator (ICD) implantation, but their ICD outcomes are not known. Objective The aim of this study was to assess the outcomes of ICD implantation and the predictors of appropriate ICD therapies in patients with MAD. Methods The study included patients with MAD who underwent ICD implantation. Clinical, electrocardiographic, cardiac imaging, and device therapy data were collected. Results Forty‐nine patients with MAD and ICD were included. Median age was 49 (21) years, and 29 (59%) were female. 13 (27%) patients underwent ICD implantation for primary prevention and 36 (73%) patients for secondary prevention. Over a median follow‐up of 27.3 (35.3) months, 23 (47%) patients received ICD therapies. 18 (37%) patients had appropriate ICD therapies, and 5 (10%) patients had inappropriate ICD shocks. Median time to first appropriate therapy was 22.3 (63.3) months. In patients with a secondary prevention ICD indication, the rate of appropriate ICD therapies was 44%, while in patients with a primary prevention ICD indication, it was 15%. Among patients with appropriate ICD therapies, the first therapies were delivered for monomorphic ventricular tachycardia (VT) in 7 (39%) patients and polymorphic VT or ventricular fibrillation (VF) in 11 (61%) patients. Patients with appropriate ICD therapies were more likely to have a history of SCA ( p = 0.003) and/or low left ventricular ejection fraction (LVEF) ( p = 0.022) before ICD implantation as compared to patients without appropriate ICD therapies. Conclusions In our cohort of patients with MAD and ICD, appropriate ICD therapies were common. Most appropriate ICD therapies were delivered for polymorphic VT or VF. Larger studies are needed to elucidate the mechanisms of VAs and refine risk stratification in MAD.
State-of-the-Art Review: Complexities in Cardiac Implantable Electronic Device Infections: A Contemporary Practical Approach
Abstract Cardiac implantable electronic device infections (CIEDIs) present substantial challenges for infectious diseases specialists, encompassing diagnosis, management, and complex decision making involving patients, families, and multidisciplinary teams. This review, guided by a common clinical case presentation encountered in daily practice, navigates through the diagnostic process, management strategies in unique scenarios, long-term follow-up, and critical discussions required for CIEDIs.
Executive Summary: State-of-the-Art Review: Complexities in Cardiac Implantable Electronic Device Infections: A Contemporary Practical Approach
Abstract Cardiac implantable electronic device infections (CIEDIs) present substantial challenges for infectious diseases specialists, encompassing diagnosis, management, and complex decision-making involving patients, families, and multidisciplinary teams. This review, guided by a common clinical case presentation encountered in daily practice, navigates through the diagnostic process, management strategies in unique scenarios, long-term follow-up, and critical discussions required for CIEDIs.
Electrophysiologic Considerations in Adult Patients with Ebstein’s Anomaly
Ebstein’s anomaly (EA) is a rare cyanotic form of congenital heart disease (CHD) characterized by apical displacement of the tricuspid valve, with resultant hemodynamic and electrical manifestations. The severity of symptoms is determined by the degree of apical displacement and deformity and incompetence of the tricuspid valve. As a result, patients with EA can be severely symptomatic during infancy and childhood or can be incidentally discovered in the sixth or seventh decade of life. Hallmarks of Ebstein’s anomaly include progressive cyanosis, right-sided heart failure, and tachyarrhythmias, among which tachyarrhythmias (most commonly atrial, but also ventricular) are the most common presenting symptoms in Ebstein’s anomaly patients during adulthood. This review aims to provide insight into the genetic and electrophysiological (EP) basis underlying the tachyarrhythmias encountered when managing patients with EA.
Abstract 4147722: Clinical impact of new severe tricuspid regurgitation following device lead extraction
Introduction: Tricuspid regurgitation (TR) is a common complication of right ventricle lead extraction (RVLE) in 5 to 10% of cases. This study aims to identify clinical outcomes such as predictors of heart failure hospitalization, need for tricuspid valve intervention, and death among patients with new severe TR after device lead removal (DLR). Methods: Patients who underwent DLR (pacemaker/ICD) between 3/1997 and 3/2024 were identified. Those who had an echocardiogram before and after RVLE with evidence of new severe TR were included. Cox univariable regression controlling for current age was used to assess association with death. Prentice Williams Peterson total time (PWPTT) Cox univariable regression was used to determine the rate of heart failure hospitalization up to three events per subject. Bivariable cox regression was used to control for ejection fraction for ICD and coil removal. Analysis was conducted using Stata IC16. Results: We identified 2,122 people who underwent RVLE, of whom 90 (4.24%) developed new severe TR and were included in the analysis. There were 68 hospitalizations among 38 people at a median of 2 years following lead extraction (IQR 0.57 to 4.5 years). The rate of hospitalization was 11.60 [9.14 to 14.71] per 100 person-years. Removal of an ICD was associated with increased hospitalization (HR 5.48 p<0.001) but not mortality (HR 1.21, p=0.707). Removal of a single coil ICD lead was associated with increased hospitalization rate (HR 3.01, p=0.031) but not mortality (HR =0.51, p=0.380). Removal of dual coil ICD lead was associated with more than a tenfold increase in hospitalization rate (HR 11.55, p=0.001) and four times the mortality rate (HR 4.05, p=0.031) (Figures 1&2). The presence of an abandoned (pacemaker/ICD) lead was associated with increased hospitalization (HR 5.75, p=0.004) and mortality (HR4.95, p=0.034). There was no change in hospitalization rate following tricuspid valve replacement (HR 1.33, p=0.716, n=18). Conclusion: Among people with new severe TR following DLR, the characteristics of the leads are strongly correlated with morbidity and mortality.
Abstract 4147530: Artificial Intelligence Predicted Age using the Electrocardiogram Predicts Mortality in Adults with Congenital Heart Disease.
Background: Artificial intelligence (AI) can be used to predict a person’s age from the electrocardiogram (ECG) (AI-ECG age) and has been proposed as a measurement of biological age. The difference between AI-ECG age and chronological age (defined as delta-age) is an independent predictor of mortality in the general population. This study assessed the relationship between AI ECG estimated age and mortality among adults living with congenital heart disease (CHD). Methods: A previously validated neural network to estimate AI-ECG age was used to analyze standard digital 12-lead ECGs in a cohort of subjects aged >18 years seen in the adult CHD (ACHD) clinic between 1992 to 2023. A single ECG, collected during the year of the first visit to the ACHD clinic was analyzed to compute the delta-age.. A positive delta-age indicates an AI ECG estimated age higher than the subject’s chronological age. The relationship between the delta-age and mortality was evaluated using Cox proportional hazard models adjusting for influential clinical factors including chronologic age, sex, ACHD severity, NYHA class and history of arrhythmia. Results: Of 5,780 subjects tested (50% females), the mean chronological age was 39.1 ± 15.0 years. AI ECG estimated age was 52.3 ± 16.6 years. Complexity of CHD was classified as mild, moderate, and severe in 7.4%, 73.9% and 18.7% of patients respectively. Patients with severe CHD had the highest delta-age of 17.1 (±18.2) years followed by moderate 12.7 (±13.6) y and simple 7.7 (±11.5) y. Patients with single ventricle had the highest deviation in AI estimated age [median delta-age 21.0 (IQR 28.6) y] followed by those with a systemic right ventricle [median delta-age of 16.3 (IQR 29.3) y]. During a median follow-up of 6.4 y (25th – 75th centile 1.58 – 13.7 y), mortality occurred in 839 (14.5%) patients. After adjusting for chronological age, CHD severity, and other clinical variables, delta-age gap was associated with increased mortality risk (HR 1.06 (1.03 – 1.09) per 5-year increment in delta-age, p<0.005), Table 1. Conclusion: The difference between AI ECG and chronological age is an independent predictor of all-cause mortality in ACHD patients.
Abstract 4146722: Incidence and Risk Factors for Atrial Arrhythmia in Adults with Systemic Right Ventricle
Introduction: The incidence and risk factors for atrial arrhythmia (AA) [atrial fibrillation (AF) and atrial flutter (AFL)] in adults with systemic right ventricle (SRV), specifically congenitally corrected-TGA (cc-TGA) and D-TGA palliated with atrial switch procedures, is not well understood. This study aims to better define these risks. Methods: Adults with SRV presenting to the Mayo Clinic between 1971 and 2022 were identified. Clinical characteristics, ECG and echocardiographic parameters were recorded at first evaluation. Sustained AA (> 30s) incidence at follow-up was documented using ECG. Cox regression analysis identified associations of incident AA. Results: Among 447 patients with SRV (mean age 34.7±14.8, 55.9% male, cc-TGA n=247; D-TGA post-atrial baffle n=200), AA was documented in 231 (51.6%) at a mean age of 37.5±18.8y. Isolated AF was observed in 88 (38.1%), isolated AFL in 71 (30.7%), and both AF and AFL in 72 (31.2%) patients. Univariate analysis showed significant predictors of AA as: age (HR:1.03, p<0.001), male sex (HR:1.49, p=0.026), NYHA class≥2 (HR:1.98, p<0.001), ventricular pacing (HR:1.64, p=0.019), QRS duration (HR:1.008, p<0.001), SRV enlargement (HR:1.73, p=0.01), SRV ejection fraction (HR:0.979,p=0.012), left atrial enlargement (HR:1.947, p=0.006), hypertension (HR:1.57, p=0.047), CKD (HR:0.991, p=0.021), and obesity (HR:1.66, p=0.023). In multivariable analysis, age (HR:1.032, p<0.001) and QRS duration (HR:1.007, p=0.013) were significant predictors of AA. Kaplan Meier analysis of time from first evaluation to incidence of AA is shown in the figure. AA was associated with heart failure in 56 (26.7%) patients. During 11.2±10.5 years of follow-up, mortality occurred in 50 (21.6%) with AA and 19 (8.8%) without AA. Conclusion: Atrial arrhythmia occurred in more than half of patients with SRV, predominantly in the third decade of life. Significant associations of AA included advancing age, longer QRS duration, enlargement of pulmonary venous atrium, reduced SRV function, hypertension and obesity. AA was associated with heart failure in one-fourth of patients and higher mortality. Close monitoring and early intervention in patients with risk factors may help mitigate the development of AA.