ABSTRACT Background Transvenous lead extraction (TLE) is a commonly performed and generally safe procedure, though procedural complexity and risk can vary based on clinical and procedural factors. Objective This study aims to identify clinical and procedural factors associated with histologic evidence of subclinical vascular injury, defined by elastin positivity on extracted leads and its clinical significance. Methods Patients undergoing TLE with a lead dwell time of ≥ 1 year were included. Extracted leads with tissue were analyzed histologically using Verhoeff–Van Gieson staining to assess the presence of elastin. Demographic data, procedural and lead characteristics, and indication for extraction were obtained. Established extraction risk scores were calculated to determine efficacy in predicting subclinical vascular injury. Results The cohort included 49 patients with 92 leads extracted. A total of 25 patients (51%) had elastin‐positive leads. Complete procedural success occurred in 95.9% of cases. The multivariate regression model did not identify any independent predictors of elastin presence, including age (OR = 1.00; 95% CI 0.95–1.05; p = 0.89), female gender (OR = 3.04; 95% CI 0.67–13.65; p = 0.14), lead dwell time (OR = 1.13; 95% CI 0.98–1.29; p = 0.07). Additionally, no scoring system, such as the CCF, EROS, MB, SAFeTY, and LECOM, predicted the presence of elastin. Conclusion Subclinical venous injury was common following TLE, yet did not predict adverse clinical outcomes, reinforcing that TLE performed in experienced centers carries a favorable safety profile. Future studies in larger cohorts are needed to further characterize the clinical utility of subclinical vascular injury.
AV Node Ablation and Conduction System Pacing Versus Biventricular Pacing in Patients With AF and HF
ABSTRACT Background In patients with atrial fibrillation (AF) and heart failure with reduced ejection fraction (HFrEF), atrioventricular node ablation (AVNA) and permanent pacing are often pursued when rhythm control is not pursued. Biventricular pacing (BiVP) has demonstrated benefits over right ventricular pacing, while conduction system pacing (CSP) has emerged as an alternative. However, evidence directly comparing CSP with BiVP in this high‐risk population remains inconsistent. Objective To compare CSP versus BiVP in patients with AF and HFrEF undergoing AVNA, focusing on cardiac function, clinical outcomes, and procedural metrics. Methods Following PRISMA guidelines, we searched PubMed, Scopus, and Web of Science through February 2026 for studies comparing CSP and BiVP in adults with AF and HFrEF undergoing AVNA. Outcomes included all‐cause mortality, heart failure hospitalization (HFH), changes in left ventricular ejection fraction (LVEF), QRS duration, New York Heart Association (NYHA) class, pacing threshold, procedure duration, and fluoroscopy duration. A random‐effects model was used to pool mean differences (MDs) or risk ratios (RRs) with 95% confidence intervals (CIs). Results Six studies (one randomized crossover trial and five observational studies; N = 766 patients: CSP = 356, BiVP = 410) were included. All‐cause mortality was significantly reduced in favor of CSP (RR 0.64 [CI: 0.44 to 0.94], p = 0.02, I 2 = 0%). There was also a trend towards lower HFH, but it marginally missed statistical significance (RR 0.77 [CI: 0.58 to 1.03], p = 0.08; I 2 = 0%). Additionally, CSP decreased NYHA class (MD ‐0.64 [CI: −1.18 to −0.10], p = 0.02; I 2 = 85%) and significantly reduced QRS duration (MD −33.56 ms [CI: −52.36 to −14.76], p = 0.0005; I 2 = 97%). LVEF improvement did not significantly differ between groups (MD 4.51% [95% CI: −1.50 to 10.52], p = 0.14; I 2 = 98%). Procedure duration and fluoroscopy times did not show statistically significant difference between the two groups (MD −11.54 min [CI: −50.05 to 26.97], p = 0.56, I 2 = 96%), and (MD −5.75 min [CI: −13.13 to 1.63], p = 0.13, I 2 = 88%), respectively. Overall pacing thresholds did not significantly differ between CSP and BiVP; however, modality‐specific subgroup analysis showed comparable thresholds between HBP and BiVP, whereas LBBP was associated with significantly lower pacing thresholds than BiVP. Conclusions Among patients with AF and HFrEF undergoing AVNA, CSP may offer symptomatic and electrocardiographic advantages over BiVP, with a possible signal toward improved major clinical outcomes that requires confirmation in larger randomized studies.
Percutaneous aspiration of infective endocarditis vegetations prior to transvenous lead extraction: a single-center experience
Abstract Background Cardiovascular implantable electronic device (CIED)-associated infective endocarditis with large vegetations carries substantial morbidity and a high risk of embolization during transvenous lead extraction (TLE). Purpose To evaluate procedural outcomes, microbiological clearance, and embolic risk in patients undergoing percutaneous aspiration of vegetations in the setting of CIED-associated infective endocarditis prior to TLE. Methods Between January 2023 and October 2025, patients with confirmed CIED-associated infective endocarditis and echocardiographic evidence of vegetations on transvenous leads or cardiac valves were included. Mechanical aspiration was performed at the operator’s discretion for vegetation size > 20 mm, multiple vegetations, prior or potential embolization risk, or ongoing sepsis. All patients underwent percutaneous aspiration using the AngioVac or Penumbra system, followed by TLE either during the same session or in a staged procedure. Baseline clinical characteristics, microbiologic data, procedural details, and outcomes were reviewed. Results Our cohort comprised five patients (60% male) with a median age of 56.8 years (IQR 49.4–66.1). Median lead dwell time was 6.1 years (IQR 3.9–14.8). Median vegetation size was 12.5 mm (IQR 8–17). Two patients had prior septic pulmonary emboli. Microbiology identified Staphylococcus aureus in 2, Streptococcus spp. in 2, and Salmonella spp. in 1. The tricuspid valve and lead were involved in 4 patients, the mitral valve in 2, and the aortic valve in 1. The AngioVac system was used in 4 cases and Penumbra in 1. Successful aspiration (≥70% reduction in vegetation size of the targeted valve) was achieved in all cases. Two patients underwent staged extraction and three underwent concomitant TLE with complete removal of the transvenous system. A total of 8 leads were extracted (median 1, IQR 1–2.5); 4 patients had ICD leads, 2 with dual coil. No clinically significant embolic events occurred during the procedures. Among two patients with persistent infection, blood cultures cleared within 24 hours in one and 96 hours in the other. There were no major procedural complications or in-hospital or 30-day mortality. One patient with multivalvular involvement (aortic, mitral, tricuspid) subsequently underwent valve replacement surgery after blood cultures became sterile post-aspiration and TLE. Conclusion Percutaneous mechanical aspiration of vegetations prior to TLE was feasible and safe, resulting in effective microbiological clearance without periprocedural embolic events or major complications. This approach provides a viable alternative to surgical extraction in selected high-risk patients with large vegetations and device-related infective endocarditis and helps control sepsis.TEE images of the TV vegetationMacroscopic image of the vegetation
Abstract 4352628: Time-Sensitive Cardiovascular Risk After COVID-19: A Population-Based Study Across Variant Eras
Introduction: Cardiovascular risks following SARS-CoV-2 infection are incompletely defined. We evaluated evolving cardiovascular outcomes across COVID-19 variant eras using a large community-based cohort to inform risk stratification and clinical care. Methods: We conducted a retrospective cohort study of 162,471 adults with COVID-19 between March 2020 and December 2023 using the Rochester Epidemiology Project. Patients were stratified by variant era (Pre-Delta, Delta, and Omicron). Cardiovascular outcomes included major adverse cardiovascular events (MACE: myocardial infarction, stroke, death), ischemic and inflammatory heart disease, thrombotic events, and dysrhythmias. Diagnoses were identified using ICD-10 codes and validated in a subset. Cumulative incidence was estimated using Kaplan-Meier and competing risk models. Cox proportional hazards regression was used to assess differences by era and age. Results: MACE occurred in 4,922 patients, primarily in those ≥80 (2-year incidence: 17%). Event rates peaked within 30 days post-infection, with marked variation by variant. In patients ≥80, 30-day MACE risk was highest in the Pre-Delta (HR 3.85; 95% CI, 3.14–4.71) and Delta (HR 2.72; 95% CI, 2.13–3.47) eras versus Omicron. After 30 days, event rates fell and era differences narrowed. Thrombotic events (n=2,090; 1.4%) decreased across eras. Ischemic and inflammatory heart disease rates were stable. Myocarditis/pericarditis were rare (0.1%) without age trends. Dysrhythmias affected 6,765 patients (2-year incidence: 4.9%) and rose with age (2.0% in <40 vs. 19.9% in ≥80). Within 30 days, risk was higher in the Pre-Delta and Delta eras for age ≥40, especially ≥80 (Delta HR 3.08; 95% CI, 2.08–4.56) and 60–79 (HR 2.23; 95% CI, 1.75–2.85). Among those 40–59, Delta posed the highest risk (HR 2.74; 95% CI, 1.94–3.86 vs. Pre-Delta HR 1.77; 95% CI, 1.26–2.49). No differences were observed in <40. Beyond 30 days, risk converged across variants. Conclusion: Cardiovascular risk after SARS-CoV-2 infection was concentrated in the first 30 days, with attenuation thereafter. While MACE and thrombotic event rates declined over time, early dysrhythmia risk varied by variant and age, especially in older adults. These findings define a time-sensitive, variant-specific risk window and support short-term, risk-stratified post-COVID monitoring. This work informs targeted follow-up protocols by infection era and age, with implications for quality improvement, resource use, and equitable care.
Background: Subaortic membrane (SAM) is a fibromuscular ridge beneath the aortic valve that causes fixed left ventricular outflow tract (LVOT) obstruction. Surgical resection is the standard treatment for symptomatic patients or those with high gradients; however, recurrence occurs in up to 14% of adults within 5 years. While radiofrequency ablation (RFA) is well-established in arrhythmia management, its role in treating SAM has not been previously described. Case Information: 53-year-old man with HTN, BMI 51.7, and well-controlled OSA presented with worsening exertional dyspnea and fatigue in April 2024. He had prior surgical SAM resection in 2018, complicated by third-degree AV block requiring pacemaker implantation. Follow-up echocardiography revealed SAM recurrence with peak LVOT gradient of 52 mmHg. Given elevated surgical risk, a novel catheter-based RFA approach was pursued. In July 2024, the patient underwent catheter-based RFA under general anesthesia. A ThermoCool SmartTouch SF catheter was advanced retroaortically across the aortic valve toward the subaortic ridge, guided by CARTO 3 with CartoSound. A semi-circular lesion set was delivered to the septum inferior to the membrane. Two steam pops occurred during ablation in this area. Serial transthoracic echocardiograms at 3 and 8 months demonstrated sustained LVOT gradient reduction, from 52 mmHg pre-ablation to 49 mmHg and 38 mmHg, respectively. Left ventricular ejection fraction (EF) remained stable at 61%, with no new wall motion abnormalities or pericardial effusion. The patient reported marked improvement in symptoms and normalization of daily activity tolerance. No procedural complications or hospital readmissions occurred. Decision-Making: Given the patient’s high surgical risk and recurrent symptoms, the multidisciplinary team determined that repeat sternotomy carried elevated morbidity. RFA offered a targeted, minimally invasive solution that leveraged electrophysiology tools and preserved structural integrity while maximizing safety. Conclusions: This first-in-human case illustrates the feasibility of intracardiac RFA for recurrent SAM. The patient experienced sustained LVOT gradient reduction, preserved EF, and marked symptomatic improvement. This novel approach may offer a viable option for select patients with recurrent subaortic obstruction and prior sternotomy, warranting further investigation to define lesion durability, depth of tissue effect, and conduction system safety.
Device-lead abnormalities and function after transcatheter tricuspid valve replacement
Abstract Aims The increasing adoption of transcatheter tricuspid valve replacement (TTVR) offers a promising therapeutic option for patients with severe tricuspid regurgitation. However, many of these patients have pre-existing cardiac implantable electronic devices (CIEDs), raising concerns about potential lead-related complications. Despite these concerns, limited data exist on the impact of TTVR on CIED integrity and function. This study aimed to evaluate the impact of TTVR on CIED lead function, including pacing thresholds, sensing, and impedance, in patients undergoing TTVR with the EVOQUE valve system. Methods and results A retrospective observational study was conducted at Mayo Clinic Rochester, including 32 consecutive patients who underwent TTVR with pre-existing CIEDs. A total of 32 patients were included, with a mean age of 79.2 ± 8.4 years; 59% were female. A total of 62.5% had a permanent pacemaker, 12.5% had an implantable cardioverter-defibrillator, 15.6% had a cardiac resynchronization therapy pacemaker, and 9.4% had a cardiac resynchronization therapy defibrillator. Following TTVR, 10 (31%) of patients developed lead function changes during a median device follow-up of 210 days (IQR: 43–307 days). The right ventricular lead was primarily affected, with only one case involving an atrial lead. Neither the Ottawa score nor the anatomical lead position reliably predicted lead abnormality (P = 0.86 and P = 0.53, respectively). R-wave sensing changes were the most common lead change observed, affecting 55% of cases. In 67% of these cases, R-wave sensing alterations occurred as an isolated finding, with no significant change in impedance or thresholds, and were managed conservatively without any need for device reprogramming. Four patients (13%) had findings concerning for a lead insulation breach, in which one (3%) required a lead revision. Among five patients with follow-up exceeding 600 days, two patients exhibited a statistically significant gradual decline in impedance without other lead dysfunction, suggesting potential subclinical lead degradation. Conclusion Transcatheter tricuspid valve replacement with the EVOQUE system in the setting of cardiac device leads is associated with lead function changes in 31%. The majority of lead-related changes were managed conservatively, but 13% of patients had findings concerning for an insulation breach. Future studies should focus on refining implantation techniques and defining optimal strategies for managing device-lead interactions in this population.