Subclinical Venous Injury in Transvenous Lead Extraction: Histological Correlation With Clinical Risk Factors
Lateef, Azalfa , Vardar, Ufuk , Hochwald, Alex, Nassar, Aziza , Ladas, Thomas, Chiriac, Anca, Niekerk, Christoffel J. van , Kusumoto, Fred , Kella, Danesh , Lateef, Azalfa U , Van Niekerk, Christoff , Kella, Danesh K , Nassar, Aziza , Kusumoto, Fred M , Hochwald, Alexander , Ladas, Thomas P. , Chiriac, Anca

Journal of Cardiovascular Electrophysiology | July 8, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1111/jce.70402 Get It

ABSTRACT Background Transvenous lead extraction (TLE) is a commonly performed and generally safe procedure, though procedural complexity and risk can vary based on clinical and procedural factors. Objective This study aims to identify clinical and procedural factors associated with histologic evidence of subclinical vascular injury, defined by elastin positivity on extracted leads and its clinical significance. Methods Patients undergoing TLE with a lead dwell time of ≥ 1 year were included. Extracted leads with tissue were analyzed histologically using Verhoeff–Van Gieson staining to assess the presence of elastin. Demographic data, procedural and lead characteristics, and indication for extraction were obtained. Established extraction risk scores were calculated to determine efficacy in predicting subclinical vascular injury. Results The cohort included 49 patients with 92 leads extracted. A total of 25 patients (51%) had elastin‐positive leads. Complete procedural success occurred in 95.9% of cases. The multivariate regression model did not identify any independent predictors of elastin presence, including age (OR = 1.00; 95% CI 0.95–1.05; p = 0.89), female gender (OR = 3.04; 95% CI 0.67–13.65; p = 0.14), lead dwell time (OR = 1.13; 95% CI 0.98–1.29; p = 0.07). Additionally, no scoring system, such as the CCF, EROS, MB, SAFeTY, and LECOM, predicted the presence of elastin. Conclusion Subclinical venous injury was common following TLE, yet did not predict adverse clinical outcomes, reinforcing that TLE performed in experienced centers carries a favorable safety profile. Future studies in larger cohorts are needed to further characterize the clinical utility of subclinical vascular injury.
Device-lead abnormalities and function after transcatheter tricuspid valve replacement
Abbasi, Muhannad , Killu, Ammar M. , Niekerk, Christoffel J. van , Deshmukh, Abhishek , Madhavan, Malini , Cha, Yong-Mei , Mulpuru, Siva K. , Friedman, Paul A. , Holst, Kimberly , Rihal, Charanjit S. , Eleid, Mackram F. , Sugrue, Alan , Van Niekerk, Christoff , Cha, Yong‐Mei , Rihal, Charanjit S.

Europace | October 14, 2025 | Volume: 27 | Issue: 10 | Pages: No page available

10.1093/europace/euaf219 Get It

Abstract Aims The increasing adoption of transcatheter tricuspid valve replacement (TTVR) offers a promising therapeutic option for patients with severe tricuspid regurgitation. However, many of these patients have pre-existing cardiac implantable electronic devices (CIEDs), raising concerns about potential lead-related complications. Despite these concerns, limited data exist on the impact of TTVR on CIED integrity and function. This study aimed to evaluate the impact of TTVR on CIED lead function, including pacing thresholds, sensing, and impedance, in patients undergoing TTVR with the EVOQUE valve system. Methods and results A retrospective observational study was conducted at Mayo Clinic Rochester, including 32 consecutive patients who underwent TTVR with pre-existing CIEDs. A total of 32 patients were included, with a mean age of 79.2 ± 8.4 years; 59% were female. A total of 62.5% had a permanent pacemaker, 12.5% had an implantable cardioverter-defibrillator, 15.6% had a cardiac resynchronization therapy pacemaker, and 9.4% had a cardiac resynchronization therapy defibrillator. Following TTVR, 10 (31%) of patients developed lead function changes during a median device follow-up of 210 days (IQR: 43–307 days). The right ventricular lead was primarily affected, with only one case involving an atrial lead. Neither the Ottawa score nor the anatomical lead position reliably predicted lead abnormality (P = 0.86 and P = 0.53, respectively). R-wave sensing changes were the most common lead change observed, affecting 55% of cases. In 67% of these cases, R-wave sensing alterations occurred as an isolated finding, with no significant change in impedance or thresholds, and were managed conservatively without any need for device reprogramming. Four patients (13%) had findings concerning for a lead insulation breach, in which one (3%) required a lead revision. Among five patients with follow-up exceeding 600 days, two patients exhibited a statistically significant gradual decline in impedance without other lead dysfunction, suggesting potential subclinical lead degradation. Conclusion Transcatheter tricuspid valve replacement with the EVOQUE system in the setting of cardiac device leads is associated with lead function changes in 31%. The majority of lead-related changes were managed conservatively, but 13% of patients had findings concerning for an insulation breach. Future studies should focus on refining implantation techniques and defining optimal strategies for managing device-lead interactions in this population.