Back to Authors

Glaser, Kevin J.

https://orcid.org/0000-0002-7464-5042

Mayo Clinic

Mayo Clinic

Citations 55

Characterization of Cellular Sources and Circulating Levels of Extracellular Vesicles in a Dietary Murine Model of Nonalcoholic Steatohepatitis
Liu, Huimin , Mauer, Amy S. , Raiter, Abagail M., Bandla, Harikrishna, Mounajjed, Taofic, Yin, Ziying , Glaser, Kevin J. , Yin, Meng , Li, Jiahui , Raiter, Abagail, Malhi, Harmeet , Yin, Meng , Yin, Ziying , Li, Jiahui , Lucien, Fabrice , Li, Jiahui

Hepatology Communications | July 10, 2019 | Volume: 3 | Issue: 9 | Pages: 1235-1249

10.1002/hep4.1404 Get It

Circulating extracellular vesicles (EVs) are a novel and emerging biomarker for nonalcoholic steatohepatitis (NASH). It has been demonstrated that total circulating EVs and hepatocyte‐derived EVs are elevated in male mice with diet‐induced NASH. How hepatocyte‐derived EVs change over time and other cellular sources of EVs in NASH have not been determined. Our objective was to define the quantitative evolution of hepatocyte‐derived, macrophage‐derived, neutrophil‐derived, and platelet‐derived EVs in male and female mice with dietary NASH. Fluorescently labeled antibodies and a nanoscale flow cytometer were used to detect plasma levels of EVs. Asialoglycoprotein receptor 1 (ASGR1) and cytochrome P450 family 2 subfamily E member 1 (CYP2E1) are markers of hepatocyte‐derived EVs; galectin 3 is a marker of macrophage‐derived EVs; common epitope on lymphocyte antigen 6 complex, locus G/C1 (Ly‐6G and Ly‐6C) is a marker of neutrophil‐derived EVs; and clusters of differentiation 61 (CD61) is a marker of platelet‐derived EVs. Nonalcoholic fatty liver disease activity score (NAS) was calculated using hematoxylin and eosin‐stained liver sections, and magnetic resonance imaging (MRI) was used for measurement of the fat fraction and elastography. Hepatocyte‐derived EVs increased in both male and female mice at 12 and 10 weeks of feeding, respectively, and remained elevated at 24 weeks in both male and female mice and at 48 weeks in male mice and 36 weeks in female mice. Macrophage‐ and neutrophil‐derived EVs were significantly elevated at 24 weeks of dietary feeding concomitant with the histologic presence of inflammatory foci in the liver. In fat‐, fructose‐, and cholesterol‐ (FFC) fed male mice, platelet‐derived EVs were elevated at 12, 24, and 48 weeks, whereas in female mice, platelet derived EVs were significantly elevated at 24 weeks. Hepatocyte‐, macrophage‐ and neutrophil‐derived EVs correlated well with the histologic NAS. Conclusion: Circulating cell‐type‐specific EVs may be a novel biomarker for NASH diagnosis and longitudinal follow up.
The Role of Three‐Dimensional Magnetic Resonance Elastography in the Diagnosis of Nonalcoholic Steatohepatitis in Obese Patients Undergoing Bariatric Surgery
Shah, Vijay H. , Therneau, Terry M. , Venkatesh, Sudhakar K. , Mounajjed, Taofic, Larson, Joseph J. , Mara, Kristin C. , Schulte, Phillip J. , Kellogg, Todd A., Kendrick, Michael L. , McKenzie, Travis J. , Greiner, Suzanne , Li, Jiahui , Glaser, Kevin J. , Wells, Michael , Yin, Meng , Greiner, Suzanne M, Wells, Michael L, Venkatesh, Sudhakar K , Mara, Kristin C , Yin, Meng , Allen, Alina M. , Chen, Jun , Ehman, Richard L. , Li, Jiahui

Hepatology | December 24, 2018 | Volume: 71 | Issue: 2 | Pages: 510-521

10.1002/hep.30483 Get It

The lack of reliable, noninvasive methods to diagnose early nonalcoholic steatohepatitis (NASH) is a major unmet need. We aimed to determine the diagnostic accuracy of three‐dimensional magnetic resonance elastography (3D‐MRE), with shear stiffness measured at 60 Hz, damping ratio at 40 Hz, and magnetic resonance imaging proton density fat fraction (MRI‐PDFF) in the detection of NASH in individuals undergoing bariatric surgery. Obese adults at risk for NASH were enrolled between 2015 and 2017 (prospective cohort, n = 88) and 2010 and 2013 (retrospective cohort, n = 87). The imaging protocol consisted of multifrequency 3D‐MRE (mf3D‐MRE) with shear waves delivered at different frequencies to explore parameters that best correlated with histologic NASH, and MRI‐PDFF to estimate steatosis. The prospective cohort was used to establish the optimal mf3D‐MRE technical parameters for NASH detection. The two cohorts were then combined to derive predictive models of NASH and disease activity by nonalcoholic fatty liver disease activity score (NAS) using the three imaging parameters that correlated with NASH. A total of 175 patients (median age 45, 81% women, and 81 [46%] with histologic NASH) were used for model derivation. From the complex shear modulus output generated by mf3D‐MRE, the damping ratio at 40 Hz and shear stiffness at 60 Hz best correlated with NASH. The fat fraction obtained from MRI‐PDFF correlated with steatosis ( P < 0.05 for all). These three parameters were fit into a logistic regression model that predicted NASH with cross‐validated area under the receiver operating characteristic curve (AUROC) = 0.73, sensitivity = 0.67, specificity = 0.80, positive predictive value = 0.73 and negative predictive value = 0.74, and disease activity by NAS with cross‐validated AUROC = 0.82. Conclusion: The mf3D‐MRE allows identification of imaging parameters that predict early NASH and disease activity. This imaging biomarker represents a promising alternative to liver biopsy for NASH diagnosis and monitoring. The results provide motivation for further studies in nonbariatric cohorts.
3D MR Elastography of Hepatocellular Carcinomas as a Potential Biomarker for Predicting Tumor Recurrence
Shan, Qungang , Yang, Hao , Kuang, Sichi , He, Bingjun , Zhang, Yao , Chen, Jingbiao , Zhang, Tianhui , Glaser, Kevin J. , Yin, Meng , Venkatesh, Sudhakar K. , Venkatesh, Sudhakar K , Yin, Meng , Wang, Jin , Liu, Yong , Zhu, Cairong , Chen, Jun , Ehman, Richard L.

Journal of Magnetic Resonance Imaging | September 8, 2018 | Volume: 49 | Issue: 3 | Pages: 719-730

10.1002/jmri.26250 Get It

BackgroundPreoperative prediction of tumor recurrence is important in the management of patients with hepatocellular carcinoma (HCC).PurposeTo investigate whether tumor stiffness derived by magnetic resonance elastography (MRE) could predict early recurrence of HCC after hepatic resection.Study TypeRetrospective.PopulationIn all, 99 patients with pathologically confirmed HCCs after surgical resection.Field Strength/Sequence3.0T; preoperative MRE with 60‐Hz mechanical vibrations using an active acoustic driver.AssessmentRegions of interest (ROIs) were manually drawn in the tumors to measure mean tumor stiffness. Surgical specimens were reviewed for histological grade, capsule, vascular invasion, and surgical margins. The early recurrence of HCC was defined as that occurring within 2 years after resection.Statistical TestsCox proportional hazard models were used to evaluate risk factors associated with the time to early recurrence.ResultsHCCs with recurrence had higher tumor stiffness, higher rate of advanced T stage, vascular invasion, lower rate of capsule formation, larger tumor size, higher aspartate aminotransferase (AST), and hepatitis B virus (HBV)‐DNA level and aspartate aminotransferase / alanine aminotransferase ratio (P = 0.031, 0.007, 0.01, <0.001, 0.015, 0.034, 0.01, and 0.014, respectively) than HCCs without recurrence. Vascular invasion (hazard ratio [HR] = 2.922; 95% confidence interval [CI]: [1.079, 7.914], P = 0.035) and mean tumor stiffness (HR = 1.163; 95% CI: [1.055, 1.282], P = 0.002) were risk factors associated with early recurrence. Each 1‐kPa increase in tumor stiffness was associated with a 16.3% increase in the risk for tumor recurrence.Data ConclusionThe mean stiffness of HCCs may be a useful, noninvasive, quantitative biomarker for the prediction of early HCC recurrence after hepatic resection.Level of Evidence: 4Technical Efficacy: Stage 5J. Magn. Reson. Imaging 2019;49:719–730.
Waveguide effects and implications for cardiac magnetic resonance elastography: A finite element study
Manduca, Armando , Rossman, Timothy, Lake, David S. , Glaser, Kevin J. , Arani, Arvin , Rossman, Phillip J. , Trzasko, Joshua D. , Dragomir‐Daescu, Dan , Araoz, Philip A. , Manduca, A , Arunachalam, S P , Arani, Arvin , Arunachalam, Shivaram P. , Ehman, Richard L.

NMR in Biomedicine | August 13, 2018 | Volume: 31 | Issue: 10 | Pages: No page available

10.1002/nbm.3996 Get It

Magnetic resonance elastography (MRE) is increasingly being applied to thin or small structures in which wave propagation is dominated by waveguide effects, which can substantially bias stiffness results with common processing approaches. The purpose of this work was to investigate the importance of such biases and artifacts on MRE inversion results in: (i) various idealized 2D and 3D geometries with one or more dimensions that are small relative to the shear wavelength; and (ii) a realistic cardiac geometry. Finite element models were created using simple 2D geometries as well as a simplified and a realistic 3D cardiac geometry, and simulated displacements acquired by MRE from harmonic excitations from 60 to 220 Hz across a range of frequencies. The displacement wave fields were inverted with direct inversion of the Helmholtz equation with and without the application of bandpass filtering and/or the curl operator to the displacement field. In all geometries considered, and at all frequencies considered, strong biases and artifacts were present in inversion results when the curl operator was not applied. Bandpass filtering without the curl was not sufficient to yield accurate recovery. In the 3D geometries, strong biases and artifacts were present in 2D inversions even when the curl was applied, while only 3D inversions with application of the curl yielded accurate recovery of the complex shear modulus. These results establish that taking the curl of the wave field and performing a full 3D inversion are both necessary steps for accurate estimation of the shear modulus both in simple thin‐walled or small structures and in a realistic cardiac geometry when using simple inversions that neglect the hydrostatic pressure term. In practice, sufficient wave amplitude, signal‐to‐noise ratio, and resolution will be required to achieve accurate results.
Feasibility and agreement of stiffness measurements using gradient-echo and spin-echo MR elastography sequences in unselected patients undergoing liver MRI
Cunha, Guilherme Moura , Glaser, Kevin J. , Bergman, Anke, Luz, Rodrigo, Figueiredo, Eduardo H de, Lopes, Flávia Paiva Proença Lobo

The British Journal of Radiology | May 2, 2018 | Volume: No volume available | Issue: No issue available | Pages: 20180126

10.1259/bjr.20180126 Get It

Pancreatic Stiffness Quantified with MR Elastography: Relationship to Postoperative Pancreatic Fistula after Pancreaticoenteric Anastomosis
Shi, Yu , Liu, Ying , Gao, Feng , Liu, Yanqing , Tao, Shengzhen , Li, Yue , Glaser, Kevin J. , Guo, Qiyong , Guo, Qiyong , Ehman, Richard L.

Radiology | April 17, 2018 | Volume: 288 | Issue: 2 | Pages: 476-484

10.1148/radiol.2018170450 Get It

Cardiac MR elastography using reduced‐FOV, single‐shot, spin‐echo EPI
Sui, Yi , Arunachalam, Shivaram P. , Arani, Arvin , Trzasko, Joshua D. , Young, Phillip M. , Glockner, James F., Glaser, Kevin J. , Lake, David S. , McGee, Kiaran P. , Rossman, Phillip J. , Araoz, Philip A. , Arunachalam, S P , Arani, Arvin , Manduca, Armando , Ehman, Richard L. , Sui, Yi

Magnetic Resonance in Medicine | December 1, 2017 | Volume: 80 | Issue: 1 | Pages: 231-238

10.1002/mrm.27029 Get It

PurposeTo implement a reduced field of view (rFOV) technique for cardiac MR elastography (MRE) and to demonstrate the improvement in image quality of both magnitude images and post‐processed MRE stiffness maps compared to the conventional full field of view (full‐FOV) acquisition.MethodsWith Institutional Review Board approval, 17 healthy volunteers underwent both full‐FOV and rFOV cardiac MRE scans using 140‐Hz vibrations. Two cardiac radiologists blindly compared the magnitude images and stiffness maps and graded the images based on several image quality attributes using a 5‐point ordinal scale. Fisher's combined probability test was performed to assess the overall evaluation. The octahedral shear strain‐based signal‐to‐noise ratio (OSS‐SNR) and median stiffness over the left ventricular myocardium were also compared.ResultsOne volunteer was excluded because of an inconsistent imaging resolution during the exam. In the remaining 16 volunteers (9 males, 7 females), the rFOV scans outperformed the full‐FOV scans in terms of subjective image quality and ghosting artifacts in the magnitude images and stiffness maps, as well as the overall preference. The quantitative measurements showed that rFOV had significantly higher OSS‐SNR (median: 1.4 [95% confidence interval (CI): 1.2–1.5] vs. 2.1 [95% CI: 1.8–2.4]), P < 0.05) compared to full‐FOV. Although no significant change was found in the median myocardial stiffness between the 2 scans, we observed a decrease in the stiffness variation within the myocardium from 2.1 kPa (95% CI: [1.9, 2.3]) to 1.9 kPa (95% CI: [1.7, 2.0]) for full‐FOV and rFOV, respectively (P < 0.05) in a subgroup of 7 subjects with ghosting present in the myocardium.ConclusionThis pilot volunteer study demonstrated that rFOV cardiac MRE has the capability to reduce ghosting and to improve image quality in both MRE magnitude images and stiffness maps. Magn Reson Med 80:231–238, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
Artificial neural networks for stiffness estimation in magnetic resonance elastography
Murphy, Matthew C. , Trzasko, Joshua D. , Glaser, Kevin J. , Manduca, Armando , Huston, John , Ehman, Richard L.

Magnetic Resonance in Medicine | November 29, 2017 | Volume: 80 | Issue: 1 | Pages: 351-360

10.1002/mrm.27019 Get It

PurposeTo investigate the feasibility of using artificial neural networks to estimate stiffness from MR elastography (MRE) data.MethodsArtificial neural networks were fit using model‐based training patterns to estimate stiffness from images of displacement using a patch size of ∼1 cm in each dimension. These neural network inversions (NNIs) were then evaluated in a set of simulation experiments designed to investigate the effects of wave interference and noise on NNI accuracy. NNI was also tested in vivo, comparing NNI results against currently used methods.ResultsIn 4 simulation experiments, NNI performed as well or better than direct inversion (DI) for predicting the known stiffness of the data. Summary NNI results were also shown to be significantly correlated with DI results in the liver (R2 = 0.974) and in the brain (R2 = 0.915), and also correlated with established biological effects including fibrosis stage in the liver and age in the brain. Finally, repeatability error was lower in the brain using NNI compared to DI, and voxel‐wise modeling using NNI stiffness maps detected larger effects than using DI maps with similar levels of smoothing.ConclusionArtificial neural networks represent a new approach to inversion of MRE data. Summary results from NNI and DI are highly correlated and both are capable of detecting biologically relevant signals. Preliminary evidence suggests that NNI stiffness estimates may be more resistant to noise than an algebraic DI approach. Taken together, these results merit future investigation into NNIs to improve the estimation of stiffness in small regions. Magn Reson Med 80:351–360, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Assessment of advanced hepatic MR elastography methods for susceptibility artifact suppression in clinical patients
Wang, Jin , Glaser, Kevin J. , Zhang, Tianhui , Shan, Qungang , He, Bingjun , Yin, Meng , Dzyubak, Bogdan , Kugel, Jennifer L., Kruse, Scott A., Grimm, Roger C., Venkatesh, Sudhakar K. , Dzyubak, Bogdan , Venkatesh, Sudhakar K , Yin, Meng , Chen, Jun , Ehman, Richard L.

Journal of Magnetic Resonance Imaging | August 12, 2017 | Volume: 47 | Issue: 4 | Pages: 976-987

10.1002/jmri.25818 Get It

PurposeTo assess the success rate, image quality, and the ability to stage liver fibrosis of a standard 2D gradient‐recalled echo (GRE) and four different spin‐echo (SE) magnetic resonance elastography (MRE) sequences in patients with different liver iron concentrations.Materials and MethodsA total of 332 patients who underwent 3T MRE examinations that included liver fat and iron quantification were enrolled, including 136 patients with all five MRE techniques. Thirty‐four patients had biopsy results for fibrosis staging. The liver stiffness, region of interest area, image quality, and success rate of the five sequences were compared in 115/136 patients. The area under the receiver operating characteristic curves (AUCs) and the accuracies for diagnosing early‐stage fibrosis and advanced fibrosis were compared. The effect of BMI (body mass index), the R2* relaxation time, and fat fraction on the image quality and liver stiffness measurements were analyzed.ResultsThe success rates were significantly higher in the four SE sequences (99.1–100%) compared with GRE MRE (85.3%) (all P < 0.001). There were significant differences of the mean ROI area between every pair of sequences (all P < 0.0001). There were no significant differences in the AUC of the five MRE sequences for discriminating advanced fibrosis (10 P‐values ranging from 0.2410–0.9171). R2* had a significant effect on the success rate and image quality for the noniron 2D echo‐planar imaging (EPI), 3D EPI and 2D GRE (all P < 0.001) sequences. BMI had a significant effect on the iron 2D EPI (P = 0.0230) and iron 2D SE (P = 0.0040) sequences.ConclusionAll five techniques showed good diagnostic performance in staging liver fibrosis. The SE MRE sequences had higher success rates and better image quality than GRE MRE in 3T clinical hepatic imaging.Level of Evidence: 3Technical Efficacy: Stage 5J. Magn. Reson. Imaging 2018;47:976–987.
Magnetic resonance elastography measured shear stiffness as a biomarker of fibrosis in pediatric nonalcoholic fatty liver disease
Schwimmer, Jeffrey B. , Behling, Cynthia , Angeles, Jorge E., Paiz, Melissa, Durelle, Janis, Africa, Jonathan A. , Newton, Kimberly P. , Brunt, Elizabeth M. , Lavine, Joel E. , Abrams, Stephanie H., Masand, Prakash, Krishnamurthy, Rajesh , Wong, Kelvin, Yin, Meng , Glaser, Kevin J. , Wolfson, Tanya, Gamst, Anthony, Hooker, Jonathan , Haufe, William, Schlein, Alexandra , Hamilton, Gavin , Middleton, Michael S. , Dzyubak, Bogdan , Ehman, Richard L. , Hamilton, Gavin , Sirlin, Claude B. , Schwimmer, Jeffrey B , Yin, Meng

Hepatology | May 11, 2017 | Volume: 66 | Issue: 5 | Pages: 1474-1485

10.1002/hep.29241 Get It

Magnetic resonance elastography (MRE) is a promising technique for noninvasive assessment of fibrosis, a major determinant of outcome in nonalcoholic fatty liver disease (NAFLD). However, data in children are limited. The purpose of this study was to determine the accuracy of MRE for the detection of fibrosis and advanced fibrosis in children with NAFLD and to assess agreement between manual and novel automated reading methods. We performed a prospective, multicenter study of two‐dimensional (2D) MRE in children with NAFLD. MR elastograms were analyzed manually at two reading centers, and using a new automated technique. Analysis using each approach was done independently. Correlations were determined between MRE analysis methods and fibrosis stage. Thresholds for classifying the presence of fibrosis and of advanced fibrosis were computed and cross‐validated. In 90 children with a mean age of 13.1 ± 2.4 years, median hepatic stiffness was 2.35 kPa. Stiffness values derived by each reading center were strongly correlated with each other (r = 0.83). All three analyses were significantly correlated with fibrosis stage (center 1, ρ = 0.53; center 2, ρ = 0.55; and automated analysis, ρ = 0.52; P < 0.001). Overall cross‐validated accuracy for detecting any fibrosis was 72.2% for all methods (95% confidence interval [CI], 61.8%‐81.1%). Overall cross‐validated accuracy for assessing advanced fibrosis was 88.9% (95% CI, 80.5%‐94.5%) for center 1, 90.0% (95% CI, 81.9%‐95.3%) for center 2, and 86.7% (95% CI, 77.9%‐92.9%) for automated analysis. Conclusion : 2D MRE can estimate hepatic stiffness in children with NAFLD. Further refinement and validation of automated analysis techniques will be an important step in standardizing MRE. How to best integrate MRE into clinical protocols for the assessment of NAFLD in children will require prospective evaluation. (H epatology 2017;66:1474–1485)