Back to Authors

Inoue, Akitoshi

https://orcid.org/0000-0002-8610-2571

Mayo Clinic

Mayo Clinic

Citations 25

Estimating the Clinical Impact of Photon-Counting-Detector CT in Diagnosing Usual Interstitial Pneumonia
Inoue, Akitoshi , Johnson, Tucker F. , White, Darin , Cox, Christian W. , Hartman, Thomas E. , Thorne, Jamison E. , Shanblatt, Elisabeth R. , Johnson, Matthew P. , Carter, Rickey E. , Lee, Yong S. , Fletcher, Joel G , Carter, Rickey E , Inoue, Akitoshi , Rajendran, Kishore , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G.

Investigative Radiology | June 15, 2022 | Volume: 57 | Issue: 11 | Pages: 734-741

10.1097/rli.0000000000000888 Get It

Objective The aim of this study was to evaluate the clinical impact of a higher spatial resolution, full field-of-view investigational photon-counting detector computed tomography (PCD-CT) on radiologist confidence in imaging findings and diagnosis of usual interstitial pneumonia (UIP) compared with conventional energy-integrating detector CT (EID-CT). Materials and Methods Patients suspected of interstitial lung disease were scanned on a PCD-CT system after informed consent and a clinically indicated EID-CT. In 2 sessions, 3 thoracic radiologists blinded to clinical history and scanner type evaluated CT images of the right and left lungs separately on EID- or PCD-CT, reviewing each lung once/session, rating confidence in imaging findings of reticulation, traction bronchiectasis, honeycombing, ground-glass opacities (GGOs), mosaic pattern, and lower lobe predominance (100-point scale: 0–33, likely absent; 34–66, indeterminate; 67–100, likely present). Radiologists also rated confidence for the probability of UIP (0–20, normal; 21–40, inconsistent with UIP; 41–60, indeterminate UIP; 61–81; probable UIP; 81–100, definite UIP) and graded image quality. Because a confidence scale of 50 represented completely equivocal findings, magnitude score (the absolute value of confidence scores from 50) was used for analysis (higher scores were more confident). Image noise was measured for each modality. The magnitude score was compared using linear mixed effects regression. The consistency of findings and diagnosis between 2 scanners were evaluated using McNemar test and weighted κ statistics, respectively. Results A total of 30 patients (mean age, 68.8 ± 11.0 years; M:F = 18:12) underwent conventional EID-CT (median CTDIvol, 7.88 mGy) and research PCD-CT (median CTDIvol, 6.49 mGy). The magnitude scores in PCD-CT were significantly higher than EID-CT for imaging findings of reticulation (40.7 vs 38.3; P = 0.023), GGO (34.4 vs 31.7; P = 0.019), and mosaic pattern (38.6 vs 35.9; P = 0.013), but not for other imaging findings (P ≥ 0.130) or confidence in UIP (34.1 vs 22.2; P < 0.059). Magnitude score of probability of UIP in PCD-CT was significantly higher than EID-CT in one reader (26.0 vs 21.5; P = 0.009). Photon-counting detector CT demonstrated a decreased number of indeterminate GGO (17 vs 26), an increased number of unlikely GGO (74 vs 50), and an increased number of likely reticulations (140 vs 130) relative to EID-CT. Interobserver agreements among 3 readers for imaging findings and probability of UIP were similar between PCD-CT and EID-CT (intraclass coefficient: 0.507–0.818 vs 0.601–0.848). Photon-counting detector CT had higher scores in overall image quality (4.84 ± 0.38) than those in EID-CT (4.02 ± 0.40; P < 0.001) despite increased image noise (mean 85.5 vs 36.1 HU). Conclusions Photon-counting detector CT provided better image quality and improved the reader confidence for presence or absence of imaging findings of reticulation, GGO, and mosaic pattern with idiosyncratic improvement in confidence in UIP presence.
Letter: normalizing the ileoanal pouch—more than a one‐step technique. Authors' reply
Quinn, Kevin P. , Busciglio, Irene, Burton, Duane D. , Lee, Yong S. , Heiken, Jay P. , Sheedy, Shannon P. , Raffals, Laura E. , Busciglio, Irene A, Inoue, Akitoshi , Raffals, Laura , Fletcher, Joel G.

Alimentary Pharmacology & Therapeutics | June 11, 2022 | Volume: 56 | Issue: 1 | Pages: 176-177

10.1111/apt.16988 Get It

LINKED CONTENTThis article is linked to Quinn et al papers. To view these articles, visit https://doi.org/10.1111/apt.16859 and https://doi.org/10.1111/apt.16954
Pineal cyst: results of long-term MRI surveillance and analysis of growth and shrinkage rates
Helal, Ahmed , Kashiwabara, Kosuke , Meyer, Fredric B. , Inoue, Akitoshi , Hasegawa, Hirotaka

Journal of Neurosurgery | May 28, 2022 | Volume: 138 | Issue: 1 | Pages: 113-119

10.3171/2022.4.jns22276 Get It

OBJECTIVE Pineal cyst (PC) is a relatively common true cyst in the pineal gland. Its long-term natural course remains ill defined. This study aims to evaluate the long-term natural history of PC and examine MRI risk factors for cyst growth and shrinkage to help better define which patients might benefit from surgical intervention. METHODS The records and MRI of 409 consecutive patients with PC were retrospectively examined (nonsurgical cohort). Cyst growth and shrinkage were defined as a ≥ 2-mm increase and decrease in cyst diameter in any direction, respectively. In addition to size, MRI signal intensity ratios were analyzed. RESULTS The median radiological follow-up period was 10.7 years (interquartile range [IQR] 6.4–14.3 years). The median change in maximal diameter was −0.6 mm (IQR −1.5 to 1.3 mm). During the observation period, cyst growth was confirmed in 21 patients (5.1%). Multivariate logistic regression analysis revealed that only age (odds ratio [OR] 0.96, 95% confidence interval [CI] 0.93–0.99, p < 0.01) was significantly associated with cyst growth. No patient required resection during the observation period. Cyst shrinkage was confirmed in 57 patients (13.9%). Multivariate analysis revealed that maximal diameter (OR 1.22, 95% CI 1.12–1.35, p < 0.01) and cyst CSF T2 signal intensity ratio (OR 9.06, 95% CI 1.38–6.62 × 101, p = 0.02) were significantly associated with cyst shrinkage. CONCLUSIONS Only 5% of PCs, mainly in patients younger than 50 years of age, have the potential to grow, while cyst shrinkage is more likely to occur across all age groups. Younger age is associated with cyst growth, while larger diameter and higher signal intensity on T2-weighted imaging are associated with shrinkage. Surgery is rarely needed for PCs, despite the possibility of a certain degree of growth.
Editorial: what is normal function of a pelvic pouch? Authors' reply
Quinn, Kevin P. , Busciglio, Irene, Burton, Duane D. , Lee, Yong S. , Heiken, Jay P. , Sheedy, Shannon P. , Raffals, Laura E. , Busciglio, Irene A, Inoue, Akitoshi , Raffals, Laura , Fletcher, Joel G.

Alimentary Pharmacology & Therapeutics | May 11, 2022 | Volume: 55 | Issue: 11 | Pages: 1454-1455

10.1111/apt.16944 Get It

LINKED CONTENTThis article is linked to Quinn et al papers. To view these articles, visit https://doi.org/10.1111/apt.16859 and https://doi.org/10.1111/apt.16916
Application of the advanced lung cancer inflammation index for patients with coronavirus disease 2019 pneumonia: Combined risk prediction model with lung cancer inflammation index, computed tomography and chest radiograph
Takahashi, Hiroaki , Ibe, Tatsuya, Ishii, Hisashi, Kurata, Yuhei, Ishizuka, Yoshikazu, Batsaikhan, Bolorkhand, Hamamoto, Yoichiro , Inoue, Akitoshi , Takahashi, Hiroaki , Ishii, Hisashi, Ishizuka, Yoshikazu

Experimental and Therapeutic Medicine | April 12, 2022 | Volume: 23 | Issue: 6 | Pages: No page available

10.3892/etm.2022.11315 Get It

Defining normal pouch function in patients with ileal pouch‐anal anastomosis: a pilot study
Quinn, Kevin P. , Busciglio, Irene, Burton, Duane D. , Lee, Yong S. , Heiken, Jay P. , Sheedy, Shannon P. , Raffals, Laura E. , Busciglio, Irene A, Inoue, Akitoshi , Raffals, Laura , Fletcher, Joel G.

Alimentary Pharmacology & Therapeutics | March 11, 2022 | Volume: 55 | Issue: 12 | Pages: 1560-1568

10.1111/apt.16859 Get It

SummaryBackgroundMost patients experience good functional outcomes following ileal pouch‐anal anastomosis (IPAA) for ulcerative colitis.AimWe aimed to determine if asymptomatic patients with an IPAA had findings consistent with normal defecation on standard objective anorectal tests.MethodsPatients 18–65 years old with IPAA and self‐reported healthy pouch function were recruited. Patients with chronic pouchitis, Crohn’s disease, anastomotic stricture, or indication for IPAA other than ulcerative or indeterminate colitis were excluded. Patients underwent an interview with an abbreviated Rome Questionnaire followed by high‐resolution ano‐pouch manometry, balloon expulsion test, pouch barostat, and magnetic resonance (MR) defecography.ResultsTwenty patients completed all testing. Six patients were excluded from the final analysis due to symptoms suggestive of pouch evacuation disorder on the abbreviated Rome Questionnaire (n = 2), structural abnormality on MR imaging (n = 3), or both (n = 1). Of the remaining 14 patients, mean anal resting pressure during high‐resolution manometry was 72 ± 16 mmHg, mean anal squeeze pressure was 247 ± 69 mmHg, and mean pouch‐anal gradient during the simulated evacuation was −27 ± 37 mmHg. The meantime to balloon expulsion was 54 seconds. During dynamic MR defecography, the mean descent of ano‐pouch junction was 2.6 cm, and mean pouch evacuation was 44.5% and 74.2% pre‐ and posttoilet phase, respectively.ConclusionsA substantial proportion of patients with IPAA and self‐reported healthy pouch function have anatomic and/or functional abnormalities of the pouch. In asymptomatic IPAA patients with an anatomically normal pouch, we have proposed normal parameters for high‐resolution ano‐pouch manometry, time to balloon expulsion, pouch barostat, and MR defecography.
CT or MR Enterography to Assess Response During Vedolizumab Therapy for Small Bowel Crohn’s Disease
Kwapisz, Lukasz , Bruining, David H. , Lee, Yong S. , Edwards, Phillip K , Holmes, David R. , Carter, Rickey E. , Siegelman, Jenifer , Fletcher, Joel G. , Inoue, Akitoshi , Fletcher, Joel G , Carter, Rickey E

Crohn's & Colitis 360 | February 1, 2022 | Volume: 4 | Issue: 1 | Pages: No page available

10.1093/crocol/otac003 Get It

Abstract Background To describe response to therapy of small bowel (SB) Crohn’s disease (CD) at CT or MR enterography (CTE/MRE) in patients on vedolizumab. Methods Patients with SB CD who underwent CTE/MRE exams greater than 12 months apart on vedolizumab therapy were included. Length (in cm) and inflammation severity (EMBARK score) of inflamed SB segments were assessed. Changes in inflammation length of 3.4 cm or greater or inflammation severity of 2 EMBARK points or greater was categorized as response or progression, as appropriate, with development of newly inflamed segments, strictures, or penetrating complications also indicating progression. Patients not meeting the criteria for response or progression were categorized as having stable disease. Results Of 36 SB CD patients, the large majority had prior surgery (86%; 31), anti-TNF use (92%; 33), and internal penetrating (78%; 28) disease. Thirty-two patients had paired baseline and follow-up CTE/MRE exams without interval surgery, with clinical response observed in 24/32 (75%). Based on imaging response criteria, 22% (7/32; 95% CI: 9%–40%) had response, 50% (16/32; 95% CI: 32%–68%) were stable, and 28% (9/32; 95% CI: 14%–47%) had disease progression. Fifty-six percent of (18/32; 95% CI: 38%–74%) patients had clinical improvement with response or stable disease by imaging. Patients with stable disease had shorter median baseline lengths of SB inflammation (P = .012). Proportion of patients with colonic inflammation, perianal disease, or penetrating complications did not change. Conclusions Most patients on vedolizumab for over 12 months demonstrated response or stable SB disease when using objective cross-sectional radiologic imaging criteria using CTE/MRE.
Predicting Risk of Surgery in Patients With Small Bowel Crohn’s Disease Strictures Using Computed Tomography and Magnetic Resonance Enterography
Inoue, Akitoshi , Bartlett, David J. , Shahraki, Narges, Sheedy, Shannon P. , Heiken, Jay P. , Voß, Benjamin, Fidler, Jeff L. , Tootooni, M. Samie , Sır, Mustafa Y. , Baker, Mark E. , Rieder, Florian , Deepak, Parakkal , Bruining, David H. , Voss, Benjamin A, Lightner, A L , Deepak, Parakkal , Fletcher, Joel G , Inoue, Akitoshi , Fidler, Jeff L. , Pasupathy, Kalyan S. , Lightner, Amy L. , Fletcher, Joel G.

Inflammatory Bowel Diseases | January 15, 2022 | Volume: 28 | Issue: 11 | Pages: 1677-1686

10.1093/ibd/izab332 Get It

Abstract Background We aimed to determine if patient symptoms and computed tomography enterography (CTE) and magnetic resonance enterography (MRE) imaging findings can be used to predict near-term risk of surgery in patients with small bowel Crohn’s disease (CD). Methods CD patients with small bowel strictures undergoing serial CTE or MRE were retrospectively identified. Strictures were defined by luminal narrowing, bowel wall thickening, and unequivocal proximal small bowel dilation. Harvey-Bradshaw index (HBI) was recorded. Stricture observations and measurements were performed on baseline CTE or MRE and compared to with prior and subsequent scans. Patients were divided into those who underwent surgery within 2 years and those who did not. LASSO (least absolute shrinkage and selection operator) regression models were trained and validated using 5-fold cross-validation. Results Eighty-five patients (43.7 ± 15.3 years of age at baseline scan, majority male [57.6%]) had 137 small bowel strictures. Surgery was performed in 26 patients within 2 years from baseline CTE or MRE. In univariate analysis of patients with prior exams, development of stricture on the baseline exam was associated with near-term surgery (P = .006). A mathematical model using baseline features predicting surgery within 2 years included an HBI of 5 to 7 (odds ratio [OR], 1.7 × 105; P = .057), an HBI of 8 to 16 (OR, 3.1 × 105; P = .054), anastomotic stricture (OR, 0.002; P = .091), bowel wall thickness (OR, 4.7; P = .064), penetrating behavior (OR, 3.1 × 103; P = .096), and newly developed stricture (OR: 7.2 × 107; P = .062). This model demonstrated sensitivity of 67% and specificity of 73% (area under the curve, 0.62). Conclusions CTE or MRE imaging findings in combination with HBI can potentially predict which patients will require surgery within 2 years.
Impact of dual-energy 50-keV virtual monoenergetic images on radiologist confidence in detection of key imaging findings of small hepatocellular carcinomas using multiphase liver CT
Voß, Benjamin, Khandelwal, Ashish , Wells, Michael , Venkatesh, Sudhakar K. , Lee, Yong S. , Johnson, Matthew P. , Fletcher, Joel G. , Voss, Benjamin A, Wells, Michael L, Inoue, Akitoshi , Fletcher, Joel G , Venkatesh, Sudhakar K

Acta Radiologica | November 1, 2021 | Volume: 63 | Issue: 11 | Pages: 1443-1452

10.1177/02841851211052993 Get It

Background Dual-energy virtual monoenergetic images can increase iodine signal, potentially increasing the conspicuity of hepatic masses. Purpose To determine if dual-energy 50-keV virtual monoenergetic images improve visualization of key imaging findings or diagnostic confidence for small (≤2 cm) hepatocellular carcinomas (HCC) at multiphase, contrast-enhanced liver computed tomography (CT). Material and Methods Patients with chronic liver disease underwent multiphase dual-energy CT imaging for HCC, with late arterial and delayed phase dual-energy 50-keV images reconstructed. Two non-reader subspecialized gastrointestinal (GI) radiologists established the reference standard, determining the location and diagnosis of all hepatic lesions using predetermined criteria. Three GI radiologists interpreted mixed kV CT images without or with dual-energy 50-keV images. Radiologists identified potential HCCs and rated their confidence (0–100 scales) in imaging findings of arterial enhancement, enhancing capsule, tumor washout, and LI-RADS 5 (2018) category. Results In total, 45 patients (14 women; mean age = 59.5 ± 10.9 years) with chronic liver disease were included. Of them, 19 patients had 25 HCCs ≤2 cm (mean size = 1.5 ± 0.4 cm). There were 17 LI-RADS 3 and 4 lesions and 19 benign lesions. Reader confidence in imaging findings of arterial enhancement, enhancing capsule, and non-peripheral washout significantly increased with dual-energy images ( P ≤ 0.022). Overall confidence in HCC diagnosis increased significantly with dual-energy 50-keV images (52.4 vs. 68.8; P = 0.001). Dual-energy images demonstrated a slight but significant decrease in overall image quality. Conclusion Radiologist confidence in key imaging features of small HCCs and confidence in imaging diagnosis increases with use of dual-energy 50-keV images at multiphase, contrast-enhanced liver CT.
A Pilot Study to Estimate the Impact of High Matrix Image Reconstruction on Chest Computed Tomography
Johnson, Tucker F. , Voß, Benjamin, Lee, Yong S. , Koo, Chi Wan , McCollough, Brian, Weaver, Jayse , Gong, Hao , Carter, Rickey E. , Inoue, Akitoshi , Voss, Benjamin A, McCollough, Brian D, Weaver, Jayse M, Carter, Rickey E , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G.

Journal of Clinical Imaging Science | September 30, 2021 | Volume: 11 | Issue: No issue available | Pages: 52

10.25259/jcis_143_2021 Get It

Objectives: The objectives of the study were to estimate the impact of high matrix image reconstruction on chest computed tomography (CT) compared to standard image reconstruction. Material and Methods: This retrospective study included patients with interstitial or parenchymal lung disease, airway disease, and pulmonary nodules who underwent chest CT. Chest CT images were reconstructed using high matrix (1024 × 1024) or standard matrix (512 × 512), with all other parameters matched. Two radiologists, blinded to reconstruction technique, independently examined each lung, viewing image sets side by side and rating the conspicuity of imaging findings using a 5-point relative conspicuity scale. The presence of pulmonary nodules and confidence in classification of internal attenuation was also graded. Overall image quality and subjective noise/artifacts were assessed. Results: Thirty-four patients with 68 lungs were evaluated. Relative conspicuity scores were significantly higher using high matrix image reconstruction for all imaging findings indicative of idiopathic lung fibrosis (peripheral airway visualization, interlobular septal thickening, intralobular reticular opacity, and end-stage fibrotic change; P ≤ 0.001) along with emphysema, mosaic attenuation, and fourth order bronchi for both readers (P ≤ 0.001). High matrix reconstruction did not improve confidence in the presence or classification of internal nodule attenuation for either reader. Overall image quality was increased but not subjective noise/artifacts with high matrix image reconstruction for both readers (P < 0.001). Conclusion: High matrix image reconstruction significantly improves the conspicuity of imaging findings reflecting interstitial lung disease and may be useful for diagnosis or treatment response assessment.