Back to Authors

Tang, Shanshan

https://orcid.org/0000-0002-1115-6479

Mayo Clinic

Mayo Clinic

Citations 11

Ultrasound Microvessel Imaging of the Human Placenta Demonstrates Altered Vessel Densities in Fetal Growth Restriction With Vascular and Immune Pathologies
Scott, Hannah M. , Tang, Shanshan , Santos, Janelle, Pone, Karina, Nienow, Michael K., Ruka, Krystal L., Breutzman, Emily N., Cheek‐Norgan, E. Heidi, Quintin, Reade A., Schenone, Mauro , Chen, Shigao , Enninga, Elizabeth Ann L. , Lok, U-Wai , Pone, Karina A, Cheek-Norgan, E Heidi, Branda, Megan E. , Ruano, Rodrigo , Schenone, Mauro H , Enninga, Elizabeth Ann L , Lok, U‐Wai , Gong, Ping , Huang, Chengwu , Breutzman, Emily, Ruano, Rodrigo

Journal of Ultrasound in Medicine | October 18, 2024 | Volume: 44 | Issue: 2 | Pages: 285-299

10.1002/jum.16604 Get It

ObjectivesFetal growth restriction (FGR) is commonly associated with placental dysfunction, increasing perinatal morbidity and mortality. Visualizing placental vessels in utero would be advantageous for identifying functional FGR cause and determining proper management strategies. We aimed to utilize high‐sensitivity ultrasound microvessel imaging (HUMI) for quantifying placental vessel density (VD) in pregnancies diagnosed with FGR.MethodsThis pilot case–control study enrolled subjects in the third trimester with a diagnosis of FGR (n = 40) and gestational age‐matched controls with normal fetal growth (n = 20) at a 2:1 ratio, respectively. The Verasonics Vantage ultrasound system was used to perform HUMI on each participant at one timepoint. Scanning involved randomized singular value decomposition‐based clutter filtering to identify the villous tree, followed by step‐by‐step scanning to acquire 3‐dimensional‐like data. Mean VD was calculated from three ultrasound measurements per subject. Additional clinical and pathology data were also collected and compared.ResultsSixteen participants were utilized to establish the scanning protocol and 2 met exclusion criteria at delivery. Thus, VD was successfully measured on 42 pregnancies scanned at 35 weeks 5 days on average. In FGR (n = 24), placental VD was significantly reduced compared to controls (P < .01). VD measures were as good at predicting FGR as systolic/diastolic (S/D) ratios (area under the curve 0.86 versus 0.80). In a smaller cohort, VD in placentas with a diagnosis of inflammatory villitis (n = 10) by histology showed an increase in VD compared to those without inflammation (P = .01). Low VD was correlated with increased S/D ratios (P = .03).ConclusionsHUMI is useful for identifying altered placental vascularization in utero for FGR. VD may be a valuable indicator for placental health and could lead to improved risk stratification methods considering underlying biology.
Novel Quantitative Liver Steatosis Assessment Method With Ultrasound Harmonic Imaging
Zhang, Jingke , Huang, Chengwu , Tang, Shanshan , Liu, Hui , DeRuiter, Ryan M. , Petersen, Kendra E , Knoll, Kate M , Robinson, Kathryn, Watt, Kymberly D., Callstrom, Matthew R. , Chen, Shigao , Petersen, Kendra E. , Zhang, Jingke , Lok, U-Wai , Liu, Hui , DeRuiter, Ryan , Petersen, Kendra, Knoll, Kate, Watt, Kymberly, Callstrom, Matthew, Huang, Chengwu , Gong, Ping , Lok, U‐Wai , Robinson, Kathryn

Journal of Ultrasound in Medicine | September 24, 2024 | Volume: 44 | Issue: 1 | Pages: 77-85

10.1002/jum.16582 Get It

ObjectivesMetabolic dysfunction‐associated steatotic liver disease (MASLD) is the most prevalent liver disorder in Western countries, with approximately 20%–30% of the MASLD patients progressing to severe stages. There is an urgent need for noninvasive, cost‐effective, widely accessible, and precise biomarkers to evaluate liver steatosis. This study aims to assess and compare the diagnostic performance of a novel reference frequency method‐based ultrasound attenuation coefficient estimation (ACE) in both fundamental (RFM‐ACE‐FI) and harmonic (RFM‐ACE‐HI) imaging for detecting and grading liver steatosis.MethodsAn Institutional Review Board‐approved prospective study was carried out between December 2018 and October 2022. A total number of 130 subjects were enrolled in the study. The correlation between RFM‐ACE‐HI values and magnetic resonance imaging proton density fat fraction (MRI‐PDFF), as well as between RFM‐ACE‐FI values and MRI‐PDFF were calculated. The diagnostic performance of RFM‐ACE‐FI and RFM‐ACE‐HI was evaluated using receiver operating characteristic (ROC) curve analysis, as compared to MRI‐PDFF. The reproducibility of RFM‐ACE‐HI was assessed by interobserver agreement between two sonographers.ResultsA strong correlation was observed between RFM‐ACE‐HI and MRI‐PDFF, with R = 0.88 (95% confidence interval [CI]: 0.83–0.92; P < .001), while the correlation between RFM‐ACE‐FI and MRI‐PDFF was R = 0.65 (95% CI: 0.50–0.76; P < .001). The area under the ROC (AUROC) curve for RFM‐ACE‐HI in staging liver steatosis grades of S ≥ 1 and S ≥ 2 was 0.97 (95% CI: 0.91–0.99; P < .001) and 0.98 (95% CI: 0.93–1.00; P < .001), respectively, and 0.76 (95% CI: 0.65–0.85) and 0.80 (95% CI: 0.70–0.88) for RFM‐ACE‐FI, respectively. Great reproducibility was achieved for RFM‐ACE‐HI, with an interobserver agreement of R = 0.97 (95% CI: 0.94–0.99; P < .001).ConclusionsThe novel RFM‐ACE‐HI method offered high liver steatosis diagnostic accuracy and reproducibility, which has important clinical implications for early disease intervention and treatment evaluation.
Technical note: Exploring the detectability of coronary calcification using ultra‐high‐resolution photon‐counting‐detector CT
Chang, Shaojie , Ren, Liqiang , Tang, Shanshan , Marsh, Jeffrey F., Hsieh, Scott S. , Hsieh, Scott, McCollough, Cynthia H. , Leng, Shuai

Medical Physics | August 31, 2023 | Volume: 50 | Issue: 11 | Pages: 6836-6843

10.1002/mp.16712 Get It

AbstractBackgroundCoronary calcification is a strong indicator of coronary artery disease, and patients with a “zero” coronary calcification score have a much lower risk of future cardiac events than those with even small amounts of calcium. However, false‐negative (incorrect zero scores) may occur if small calcifications are missed at CT due to limited spatial resolution.PurposeTo demonstrate lower limits of detection for coronary calcification using an ultra‐high‐resolution (UHR) mode on a clinical photon‐counting‐detector CT (PCD‐CT), compared to a conventional energy‐integrating‐detector CT (EID‐CT).MethodsChicken eggshell fragments (0.4–0.8 mm) mimicking coronary calcifications were scanned on a clinical PCD‐CT (NAEOTOM Alpha) in UHR mode and a conventional EID‐CT (SOMATOM Force) with matched tube potential and radiation dose levels to the PCD‐CT. PCD‐CT images were reconstructed with a sharp kernel (Qr68) and a quantum iterative algorithm (QIR‐3). Two sets of EID‐CT images were reconstructed: routine clinical kernel (Qr36, ADMIRE‐3) and a sharper kernel (Qr54) with similar noise to PCD‐CT images. With institutional review board approval, in vivo exams performed with the PCD‐CT in UHR mode were compared against patients’ clinical EID‐CT exams. The visibility of calcifications on PCD‐CT and EID‐CT images was assessed and compared qualitatively.ResultsPCD‐CT images visualized all calcified fragments, while EID‐CT failed to detect those below 0.6 mm using a routine protocol. EID‐CT with Qr54 improved visibility but distorted boundaries. Calcifications were less visible on EID‐CT than PCD‐CT as phantom sizes increased. 0.6‐ and 0.7‐mm calcified fragments were barely visible on 35‐ and 40‐cm phantom EID‐CT images. Patient cases showed small calcifications missed on EID‐CT but detected on PCD‐CT.ConclusionAt matched radiation dose, PCD‐CT in UHR mode provided higher spatial resolution and improved the detectability of small calcified fragments for different phantom/patient sizes in comparison to EID‐CT.
Robust Principal Component Analysis with Wavelet-Based Sparsity Promotion to Mitigate Reverberation Clutters for Ultrasound Attenuation Estimation
Lok, U‐Wai , Tang, Shanshan , Zhou, Chenyun , Watt, Kymberly D., Callstrom, Matthew R. , Trzasko, Joshua D. , Chen, Shigao , Lok, U-Wai , Gong, Ping , Huang, Chengwu , Yang, Lulu

2022 IEEE International Ultrasonics Symposium (IUS) | December 1, 2022 | Volume: No volume available | Issue: No issue available | Pages: 1-4

10.1109/ius54386.2022.9957606 Get It

Reverberation clutter signal suppression in ultrasound attenuation estimation using wavelet-based robust principal component analysis
Lok, U‐Wai , Huang, Chengwu , Tang, Shanshan , Zhou, Chenyun , Watt, Kymberly D., Callstrom, Matthew R. , Trzasko, Joshua D. , Chen, Shigao , Gong, Ping , Huang, Chengwu , Yang, Lulu, Callstrom, Matthew, Lok, U-Wai , Gong, Ping , Yang, Lulu

Physics in Medicine & Biology | March 31, 2022 | Volume: 67 | Issue: 9 | Pages: 095018

10.1088/1361-6560/ac62fd Get It

Abstract Objective . Ultrasound attenuation coefficient estimation (ACE) has diagnostic potential for clinical applications such as quantifying fat content in the liver. Previously, we have proposed a system-independent ACE technique based on spectral normalization of different frequencies, called the reference frequency method (RFM). This technique does not require a well-calibrated reference phantom for normalization. However, this method may be vulnerable to severe reverberation clutter introduced by the body wall. The clutter superimposed on liver echoes may bias the estimation. Approach . We proposed to use robust principal component analysis, combined with wavelet-based sparsity promotion, to suppress the severe reverberation clutters. The capability to mitigate the reverberation clutters was validated through phantom and in vivo studies. Main Results . In the phantom studies with added reverberation clutters, higher normalized cross-correlation and smaller mean absolute errors were attained as compared to RFM results without the proposed method, demonstrating the capability to reconstruct tissue signals from reverberations. In a pilot patient study, the correlation between ACE and proton density fat fraction (PDFF), a measurement of liver fat by MRI as a reference standard, was investigated. The proposed method showed an improvement of the correlation (coefficient of determination, R = 0.82) as compared with the counterpart without the proposed method ( R = 0.69). Significance : The proposed method showed the feasibility of suppressing the reverberation clutters, providing an important basis for the development of a robust ACE with large reverberation clutters.
Clinically-translatable High-fidelity Photoacoustic Tomography Enhanced by Virtual Point Sources
Tang, Yuqi , Tang, Shanshan , Huang, Chengwu , Chen, Shigao , Huang, Chengwu , Yao, Junjie

No container title available | December 17, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-1153472/v1 Get It

Abstract Photoacoustic tomography (PAT), a hybrid imaging modality that acoustically detects the optical absorption contrast, is a promising technology for imaging hemodynamic functions in deep tissues. Particularly, PAT is capable of measuring the blood oxygenation level using hemoglobin as the endogenous contrast. However, the most clinically compatible PAT configuration usually employs a linear ultrasound transducer array and often suffers from the poor image fidelity, mostly due to the limited detection view of the transducer array. PAT can be improved by employing highly-absorbing contrast agents such as droplets and nanoparticles, which, however, have low clinical translation potential due to safety concerns and regulatory hurdles. Moreover, unlike hemoglobin, these exogenous contrast agents cannot report the functional hemodynamic information. In this work, we have developed a new methodology that can improve PAT’s image fidelity without hampering its functional capability or clinical translation potential. By using clinically-approved microbubbles as virtual point sources that strongly scatter the local pressure waves generated by surrounding hemoglobin, we can overcome the limited-detection-view problem and achieve high-fidelity functional PAT in deep tissues, a technology referred to as virtual-point-source PAT (VPS-PAT). We have thoroughly investigated the working principle of VPS-PAT by numerical simulations and phantom validations, showing the acoustic origin of signal enhancement and the superiority over traditional PAT. We have also demonstrated proof-of-concept applications of functional VPT-PAT for in vivo small-animal studies with physiological challenges. We expect that VPS-PAT can find broad applications in biomedical research and accelerated translation to clinical impact.
Photoacoustic computed tomography of mechanical HIFU-induced vascular injury
Vu, Tri , Tang, Yuqi , Li, Mucong , Sankin, Georgii, Tang, Shanshan , Chen, Shigao , Zhong, Pei , Yao, Junjie

Biomedical Optics Express | June 17, 2021 | Volume: 12 | Issue: 9 | Pages: 5489

10.1364/boe.426660 Get It

Mechanical high-intensity focused ultrasound (HIFU) has been used for cancer treatment and drug delivery. Existing monitoring methods for mechanical HIFU therapies such as MRI and ultrasound imaging often suffer from high cost, poor spatial-temporal resolution, and/or low sensitivity to tissue’s hemodynamic changes. Evaluating vascular injury during mechanical HIFU treatment, therefore, remains challenging. Photoacoustic computed tomography (PACT) is a promising tool to meet this need. Intrinsically sensitive to optical absorption, PACT provides high-resolution imaging of blood vessels using hemoglobin as the endogenous contrast. In this study, we have developed an integrated HIFU-PACT system for detecting vascular rupture in mechanical HIFU treatment. We have demonstrated singular value decomposition for enhancing hemorrhage detection. We have validated the HIFU-PACT performance on phantoms and in vivo animal tumor models. We expect that PACT-HIFU will find practical applications in oncology research using small animal models.
Quantitative Shear Wave Speed Assessment for Muscles With the Diagnosis of Taut Bands and/or Myofascial Trigger Points Using Probe Oscillation Shear Wave Elastography: A Pilot Study
Lok, U‐Wai , Zhou, Chenyun , Tang, Shanshan , Madson, Timothy J., Gay, Ralph E. , Chen, Shigao , Yang, Lulu, Ling, Wenwu, Gong, Ping , Lok, U-Wai , Huang, Chengwu , Yang, Lulu , Ling, Wenwu , Gong, Ping , Jensen, Mark A.

Journal of Ultrasound in Medicine | June 4, 2021 | Volume: 41 | Issue: 4 | Pages: 845-854

10.1002/jum.15764 Get It

ObjectiveTo use probe oscillation shear wave elastography (PROSE) with two vibration sources to generate two shear waves in the imaging plane to quantitatively assess the shear wave speeds (SWSs) of muscles with and without the diagnosis of taut bands (TB) and/or myofascial trigger points (MTrPs).MethodsThirty‐three patients were scanned with the PROSE technique. Shear waves were generated through continuous vibration of the ultrasound probe, while the shear wave motions were detected using the same probe. SWSs for the sides with and without TBs and/or MTrPs were computed and compared. The pressure pain thresholds (PPTs) were measured as an indicator of maximum pain tolerance of patients. The statistical differences between the SWSs with and without TBs and/or MTrPs with different PPT values were analyzed using the nonparametric Wilcoxon rank‐sum test.ResultsThe mean SWSs for the sides with TBs and/or MTrPs are faster than that of the contralateral side without TBs and/or MTrPs. A significant difference was observed between mean SWSs with and without TBs and/or MTrPs without any information of PPT, with rank‐sum test P < .005. Additionally, with the information of PPT, a significant difference was observed between mean SWSs for the sides with and without TBs and/or MTrPs, for PPT values between 0 and 50 N/cm2 (P < .005), but for PPT values between 50 and 90 N/cm2, it was difficult to differentiate mean SWSs with and without TBs and/or MTrPs.ConclusionOur preliminary results show that SWSs measured from patients had a significant difference between the mean SWSs with and without TBs and/or MTrPs.
Fast super-resolution ultrasound microvessel imaging using spatiotemporal data with deep fully convolutional neural network
Lok, U‐Wai , Tang, Shanshan , Zhang, Wei , Korfiatis, Panagiotis , Blezek, Daniel J. , Zheng, Rongqin , Trzasko, Joshua D. , Chen, Shigao , Gong, Ping , Yang, Lulu, Zhang, Wei , Lok, U-Wai , Huang, Chengwu , Gong, Ping , Yang, Lulu , Kim, Yohan , Lucien, Fabrice

Physics in Medicine & Biology | March 2, 2021 | Volume: 66 | Issue: 7 | Pages: 075005

10.1088/1361-6560/abeb31 Get It

Abstract Ultrasound localization microscopy (ULM) has been proposed to image microvasculature beyond the ultrasound diffraction limit. Although ULM can attain microvascular images with a sub-diffraction resolution, long data acquisition time and processing time are the critical limitations. Deep learning-based ULM (deep-ULM) has been proposed to mitigate these limitations. However, microbubble (MB) localization used in deep-ULMs is currently based on spatial information without the use of temporal information. The highly spatiotemporally coherent MB signals provide a strong feature that can be used to differentiate MB signals from background artifacts. In this study, a deep neural network was employed and trained with spatiotemporal ultrasound datasets to better identify the MB signals by leveraging both the spatial and temporal information of the MB signals. Training, validation and testing datasets were acquired from MB suspension to mimic the realistic intensity-varying and moving MB signals. The performance of the proposed network was first demonstrated in the chicken embryo chorioallantoic membrane dataset with an optical microscopic image as the reference standard. Substantial improvement in spatial resolution was shown for the reconstructed super-resolved images compared with power Doppler images. The full-width-half-maximum (FWHM) of a microvessel was improved from 133 μ m to 35 μ m, which is smaller than the ultrasound wavelength (73 μ m). The proposed method was further tested in an in vivo human liver data. Results showed the reconstructed super-resolved images could resolve a microvessel of nearly 170 μ m (FWHM). Adjacent microvessels with a distance of 670 μ m, which cannot be resolved with power Doppler imaging, can be well-separated with the proposed method. Improved contrast ratios using the proposed method were shown compared with that of the conventional deep-ULM method. Additionally, the processing time to reconstruct a high-resolution ultrasound frame with an image size of 1024 × 512 pixels was around 16 ms, comparable to state-of-the-art deep-ULMs.
Liraglutide reduces attenuation coefficient as a measure of hepatic steatosis during 16 weeks' treatment in nondiabetic obese patients: A pilot trial
Zhou, Chenyun , Lok, U‐Wai , Tang, Shanshan , Taylor, Ann, Eckert, Deborah J., Chen, Shigao , Camilleri, Michael , Eckert, Deborah, Camilleri, M , Lok, U-Wai , Wang, Xiao Jing, Gong, Ping , Huang, Chengwu

JGH Open | December 30, 2020 | Volume: 5 | Issue: 2 | Pages: 193-198

10.1002/jgh3.12464 Get It

AbstractBackground and AimLiraglutide, a long‐acting GLP‐1 analog, is approved for the treatment of obesity with improvements in fasting blood glucose, hemoglobin A1c, and cardiovascular health. Our aim was to measure the impact of liraglutide dose for obesity on hepatic steatosis measured by ultrasound.MethodsA single‐center, randomized, double‐blind, placebo‐controlled pilot trial was undertaken in nondiabetic obese, otherwise healthy patients aged 18–65 years. Participants were randomly assigned to receive subcutaneous liraglutide (3.0 mg) or placebo over 16 weeks with dose escalation following US Food and Drug Administration guidelines. Both groups received standardized nutritional and behavioral counseling during the 16 weeks. Hepatic fat content was measured by ultrasound at baseline, 8 weeks, and 16 weeks as an attenuation coefficient (ACE). Effects of treatment were assessed using t‐test for the entire groups and for patient subgroup with baseline ACE >0.66 (indicating significant steatosis).ResultsAmong 30 patients (93% female) enrolled, 16 were randomized to placebo and 14 to liraglutide. Baseline body mass indices (BMIs) and average age were similar in the two groups. After 16 weeks, the liraglutide group had a significant improvement in steatosis ACE scores (−0.068 ± 0.02 vs −0.0077 ± 0.02 placebo, P = 0.05). Change in steatosis was positively correlated with change in BMI (R2 = 0.402, P = 0.0007). Within the liraglutide group, patients with baseline ACE >0.66 had improvement in ACE (−0.134 ± 0.03) compared to those without significant steatosis (−0.041 ± 0.02, P = 0.05).ConclusionsIn this pilot trial, liraglutide, 3.0 mg over 16 weeks, reduced hepatic steatosis; a reduction in hepatic steatosis is correlated with BMI reduction, and effects are particularly evident in those with a significant degree of steatosis by ultrasound imaging.