Back to Authors

Ruka, Krystal L.

Mayo Clinic

Mayo Clinic

Citations 5

Ultrasound Microvessel Imaging of the Human Placenta Demonstrates Altered Vessel Densities in Fetal Growth Restriction With Vascular and Immune Pathologies
Scott, Hannah M. , Tang, Shanshan , Santos, Janelle, Pone, Karina, Nienow, Michael K., Ruka, Krystal L., Breutzman, Emily N., Cheek‐Norgan, E. Heidi, Quintin, Reade A., Schenone, Mauro , Chen, Shigao , Enninga, Elizabeth Ann L. , Lok, U-Wai , Pone, Karina A, Cheek-Norgan, E Heidi, Branda, Megan E. , Ruano, Rodrigo , Schenone, Mauro H , Enninga, Elizabeth Ann L , Lok, U‐Wai , Gong, Ping , Huang, Chengwu , Breutzman, Emily, Ruano, Rodrigo

Journal of Ultrasound in Medicine | October 18, 2024 | Volume: 44 | Issue: 2 | Pages: 285-299

10.1002/jum.16604 Get It

ObjectivesFetal growth restriction (FGR) is commonly associated with placental dysfunction, increasing perinatal morbidity and mortality. Visualizing placental vessels in utero would be advantageous for identifying functional FGR cause and determining proper management strategies. We aimed to utilize high‐sensitivity ultrasound microvessel imaging (HUMI) for quantifying placental vessel density (VD) in pregnancies diagnosed with FGR.MethodsThis pilot case–control study enrolled subjects in the third trimester with a diagnosis of FGR (n = 40) and gestational age‐matched controls with normal fetal growth (n = 20) at a 2:1 ratio, respectively. The Verasonics Vantage ultrasound system was used to perform HUMI on each participant at one timepoint. Scanning involved randomized singular value decomposition‐based clutter filtering to identify the villous tree, followed by step‐by‐step scanning to acquire 3‐dimensional‐like data. Mean VD was calculated from three ultrasound measurements per subject. Additional clinical and pathology data were also collected and compared.ResultsSixteen participants were utilized to establish the scanning protocol and 2 met exclusion criteria at delivery. Thus, VD was successfully measured on 42 pregnancies scanned at 35 weeks 5 days on average. In FGR (n = 24), placental VD was significantly reduced compared to controls (P < .01). VD measures were as good at predicting FGR as systolic/diastolic (S/D) ratios (area under the curve 0.86 versus 0.80). In a smaller cohort, VD in placentas with a diagnosis of inflammatory villitis (n = 10) by histology showed an increase in VD compared to those without inflammation (P = .01). Low VD was correlated with increased S/D ratios (P = .03).ConclusionsHUMI is useful for identifying altered placental vascularization in utero for FGR. VD may be a valuable indicator for placental health and could lead to improved risk stratification methods considering underlying biology.
EP16.27: Is sonographic stomach position in congenital diaphragmatic hernia reproducible for clinical use?
Ibirogba, Eniola R. , Novoa, V. Arruga Novoa y, Sutton, Laura F., Neis, Allan E., Marroquim, A., Coleman, Tenn, Praska, Kathleen A., Freimund, Tamara A., Ruka, Krystal L., Warzala, Vicki L., Sangi‐Haghpeykar, Haleh , Ibirogba, Eniola R , Ruano, Rodrigo

Ultrasound in Obstetrics & Gynecology | October 1, 2019 | Volume: 54 | Issue: S1 | Pages: 332-333

10.1002/uog.21438 Get It

Standardization and reproducibility of sonographic stomach position grades in fetuses with congenital diaphragmatic hernia
Ibirogba, Eniola R. , Novoa, Victoria Arruga Novoa y, Sutton, Laura F., Neis, Allan E., Marroquin, Amber M., Coleman, Tracey M., Praska, Kathleen A., Freimund, Tamara A., Ruka, Krystal L., Warzala, Vicki L., Sangi‐Haghpeykar, Haleh , Ruano, Rodrigo , Ibirogba, Eniola R , Ruano, Rodrigo

Journal of Clinical Ultrasound | July 17, 2019 | Volume: 47 | Issue: 9 | Pages: 513-517

10.1002/jcu.22759 Get It

AbstractObjectivesThe purpose of this study was to evaluate the reproducibility of stomach position grading in congenital diaphragmatic hernia (CDH) as proposed by Cordier et al and Basta et al after standardization of the methods at our center.MethodsWe collected sonographic images from 23 fetuses with left‐sided CDH at our center from 2010 to 2018. Nine operators (one maternal fetal medicine expert and eight sonographers) reviewed the selected images and graded the stomach position according to the methods of Cordier et al and Basta et al. We assessed the interoperator agreement with Fleiss's kappa statistics.ResultsOverall agreement amongst all operators was moderate for both methods proposed by Cordier et al (k = 0.60, SE 0.07, 95% CI 0.47‐0.73, P < .0001) and Basta et al (k = 0.60, SE 0.06, 95% CI 0.47‐0.73, P < .0001). Interoperator agreement was moderate for grade 3 with the method by Cordier et al (k = 0.45, SE 0.09, 95% CI 0.27‐0.64, P < .0001) and fair for grade 4 with the method by Basta et al (k = 0.33, SE 0.08, 95% CI 0.18‐0.49 P < .0001).ConclusionsOur study demonstrates a fair to moderate interoperator agreement of the stomach position grading methods proposed in the literature after standardization of the methods at our center. Further multicenter studies are needed to confirm our results.
Reproducibility of Liver‐to‐Thorax Area Ratio Ultrasound Measurements in Congenital Diaphragmatic Hernia
Novoa, Victoria Arruga Novoa y, Sutton, Laura F., Neis, Allan E., Marroquin, Amber M., Coleman, Tracey M., Praska, Kathleen A., Freimund, Tamara A., Ruka, Krystal L., Warzala, Vicki L., Sangi‐Haghpeykar, Haleh , Novoa Y Novoa, Victoria Arruga, Ruano, Rodrigo

Journal of Ultrasound in Medicine | September 23, 2018 | Volume: 38 | Issue: 6 | Pages: 1477-1482

10.1002/jum.14826 Get It

ObjectivesThe aim of this study was to investigate the reproducibility of a standardized method to assess the ultrasound liver‐to‐thoracic area ratio in fetuses with congenital diaphragmatic hernia.MethodsWe selected 24 images of 9 fetuses diagnosed with left‐sided at our institution between January 2010 and December 2017. Eight operators (1 maternal‐fetal medicine specialist and 7 sonographers) reviewed the selected images and assessed the ultrasound liver‐to‐thoracic area ratio according to a standardized protocol. We evaluated the correlation between operators using the intraclass correlation coefficient and compared agreement between the sonographers and a physician with experience in measuring the ultrasound liver‐to‐thoracic area ratio using a Bland‐Altman analysis.ResultsGood intraoperator reproducibility was observed for the standardized ultrasound liver‐to‐thoracic area ratio (intraclass correlation coefficient, 0.78). Good agreement among sonographers and the physician was also observed for the standardized measurements (bias, 0.01; precision, 0.03; limits of agreement, –0.05 to + 0.07).ConclusionsWe demonstrated that good intraoperator and interoperator reproducibility of ultrasound liver‐to‐thoracic area ratio assessment is feasible after standardizing the method in our center.
Reproducibility of Lung‐to‐Head Ratio Ultrasound Measurements in Congenital Diaphragmatic Hernia
Novoa, Victoria Arruga Novoa y, Sutton, Laura F., Neis, Allan E., Marroquin, Amber M., Freimund, Tamara A., Coleman, Tracey M., Praska, Kathleen A., Ruka, Krystal L., Warzala, Vicki L., Sangi‐Haghpeykar, Haleh , Novoa Y Novoa, Victoria Arruga, Ruano, Rodrigo , Ruano, Rodrigo

Journal of Ultrasound in Medicine | February 5, 2018 | Volume: 37 | Issue: 8 | Pages: 2037-2041

10.1002/jum.14557 Get It

ObjectivesThis study investigated the reproducibility of standardization of lung‐to‐head ratio measurements in congenital diaphragmatic hernia (CDH) at our center among sonographers after we standardized the method.MethodsWe reviewed ultrasound images of 12 fetuses with CDH at Mayo Clinic from 2010 to 2016. Nine operators (1 maternal‐fetal medicine specialist with experience in measuring the lung‐to‐head ratio and 8 sonographers), who were blinded to previous findings, reviewed 33 selected images from 12 fetuses with left CDH. The method for lung‐to‐head ratio measurement was standardized before starting the measurements. The lung‐to‐head ratio was assessed by different methods to obtain the lung areas: anteroposterior, longest, and area tracing. We evaluated the correlation between operators using the intraclass correlation coefficient (ICC). We also compared agreement between the sonographers and a physician with experience in measuring the lung‐to‐head ratio using a Bland‐Altman analysis.ResultsThe methods with the best interoperator reproducibility were the standardized anteroposterior lung‐to‐head ratio (ICC, 0.69) and the standardized lung‐to‐head ratio tracing (ICC, 0.65) compared to the longest lung‐to‐head ratio (ICC, 0.56). The standardized lung‐to‐head ratio tracing had the best agreement among sonographers and the physician (bias, 0.11; limits of agreement, −0.27 to +0.49) than the anteroposterior lung‐to‐head ratio (bias, 0.35; limits of agreement, −0.13 to + 0.83) and the longest lung‐to‐head ratio (bias, 0.27; limits of agreement, −0.35 to +0.89).ConclusionsWe demonstrated that the lung‐to‐head ratio tracing method has high interoperator reproducibility and the best agreement among the operators at our center. Further multicenter studies are necessary to confirm our results.