Back to Authors

Sangi‐Haghpeykar, Haleh

https://orcid.org/0000-0002-2511-5600

Mayo Clinic

Baylor College of Medicine

Citations 8

Obstetric outcomes after fetal intervention – a single-center descriptive review
Narang, Kavita , Ibirogba, Eniola R. , Sangi‐Haghpeykar, Haleh , Ruano, Rodrigo , Ruano, Rodrigo , Ibirogba, Eniola R

The Journal of Maternal-Fetal & Neonatal Medicine | July 11, 2021 | Volume: 35 | Issue: 25 | Pages: 7102-7108

10.1080/14767058.2021.1943658 Get It

EP16.27: Is sonographic stomach position in congenital diaphragmatic hernia reproducible for clinical use?
Ibirogba, Eniola R. , Novoa, V. Arruga Novoa y, Sutton, Laura F., Neis, Allan E., Marroquim, A., Coleman, Tenn, Praska, Kathleen A., Freimund, Tamara A., Ruka, Krystal L., Warzala, Vicki L., Sangi‐Haghpeykar, Haleh , Ibirogba, Eniola R , Ruano, Rodrigo

Ultrasound in Obstetrics & Gynecology | October 1, 2019 | Volume: 54 | Issue: S1 | Pages: 332-333

10.1002/uog.21438 Get It

Standardization and reproducibility of sonographic stomach position grades in fetuses with congenital diaphragmatic hernia
Ibirogba, Eniola R. , Novoa, Victoria Arruga Novoa y, Sutton, Laura F., Neis, Allan E., Marroquin, Amber M., Coleman, Tracey M., Praska, Kathleen A., Freimund, Tamara A., Ruka, Krystal L., Warzala, Vicki L., Sangi‐Haghpeykar, Haleh , Ruano, Rodrigo , Ibirogba, Eniola R , Ruano, Rodrigo

Journal of Clinical Ultrasound | July 17, 2019 | Volume: 47 | Issue: 9 | Pages: 513-517

10.1002/jcu.22759 Get It

AbstractObjectivesThe purpose of this study was to evaluate the reproducibility of stomach position grading in congenital diaphragmatic hernia (CDH) as proposed by Cordier et al and Basta et al after standardization of the methods at our center.MethodsWe collected sonographic images from 23 fetuses with left‐sided CDH at our center from 2010 to 2018. Nine operators (one maternal fetal medicine expert and eight sonographers) reviewed the selected images and graded the stomach position according to the methods of Cordier et al and Basta et al. We assessed the interoperator agreement with Fleiss's kappa statistics.ResultsOverall agreement amongst all operators was moderate for both methods proposed by Cordier et al (k = 0.60, SE 0.07, 95% CI 0.47‐0.73, P < .0001) and Basta et al (k = 0.60, SE 0.06, 95% CI 0.47‐0.73, P < .0001). Interoperator agreement was moderate for grade 3 with the method by Cordier et al (k = 0.45, SE 0.09, 95% CI 0.27‐0.64, P < .0001) and fair for grade 4 with the method by Basta et al (k = 0.33, SE 0.08, 95% CI 0.18‐0.49 P < .0001).ConclusionsOur study demonstrates a fair to moderate interoperator agreement of the stomach position grading methods proposed in the literature after standardization of the methods at our center. Further multicenter studies are needed to confirm our results.
Reproducibility of fetal lung‐to‐head ratio in left diaphragmatic hernia across the North American Fetal Therapy Network (NAFTNet)
Abbasi, Nimrah , Ryan, Greg , Johnson, Anthony , Sangi‐Haghpeykar, Haleh , Ye, Xiang Y. , Shah, Prakesh S. , Benachi, Alexandra , Saada, Julien, Ruano, Rodrigo , NAFTNet*, on behalf of the, Papanna, Ramesha , Cortes, Magda Sanz , Benachi, Alexandra , Ruano, Rodrigo , NAFTNet*, on behalf of the, Papanna, Ramesha

Prenatal Diagnosis | January 9, 2019 | Volume: 39 | Issue: 3 | Pages: 188-194

10.1002/pd.5413 Get It

AbstractObjectiveTo determine the antenatal sonographic lung area measurement method in left congenital diaphragmatic hernia (CDH) with the highest interrater agreement among North American Fetal Therapy Network (NAFTNet) centers within and outside the fetoscopic tracheal occlusion (FETO) consortium and in comparison with a European “expert” reviewer (ER).MethodsNineteen members from nine FETO consortium centers and 29 reviewers from 17 non‐FETO centers reviewed ultrasound clips of the chest from 13 fetuses with isolated left CDH and were asked to select a static plane for lung area measurement using anteroposterior (AP), longest, and trace methods. Interrater agreement in lung area measurements was determined using intraclass correlation coefficient (ICC). Bland‐Altman analysis was used to evaluate mean difference (bias) between NAFTNet reviewers and ER.ResultsAmong FETO centers, agreement was highest using trace (ICC 0.94; 95% CI, 0.83‐0.98), followed by longest (ICC 0.89; 95% CI, 0.75‐0.97) and lowest for A‐P (ICC 0.83; 95% CI, 0.67‐0.94). Similar trends were noted in non‐FETO centers. When compared with ER, bias was lowest for trace: 14 ± 38 mm2 and 19 ± 36 mm2 for FETO and non‐FETO centers, respectively.ConclusionThe trace method demonstrated the highest interrater agreement and lowest bias for lung area estimation in left CDH across NAFTNet.
Reproducibility of Liver‐to‐Thorax Area Ratio Ultrasound Measurements in Congenital Diaphragmatic Hernia
Novoa, Victoria Arruga Novoa y, Sutton, Laura F., Neis, Allan E., Marroquin, Amber M., Coleman, Tracey M., Praska, Kathleen A., Freimund, Tamara A., Ruka, Krystal L., Warzala, Vicki L., Sangi‐Haghpeykar, Haleh , Novoa Y Novoa, Victoria Arruga, Ruano, Rodrigo

Journal of Ultrasound in Medicine | September 23, 2018 | Volume: 38 | Issue: 6 | Pages: 1477-1482

10.1002/jum.14826 Get It

ObjectivesThe aim of this study was to investigate the reproducibility of a standardized method to assess the ultrasound liver‐to‐thoracic area ratio in fetuses with congenital diaphragmatic hernia.MethodsWe selected 24 images of 9 fetuses diagnosed with left‐sided at our institution between January 2010 and December 2017. Eight operators (1 maternal‐fetal medicine specialist and 7 sonographers) reviewed the selected images and assessed the ultrasound liver‐to‐thoracic area ratio according to a standardized protocol. We evaluated the correlation between operators using the intraclass correlation coefficient and compared agreement between the sonographers and a physician with experience in measuring the ultrasound liver‐to‐thoracic area ratio using a Bland‐Altman analysis.ResultsGood intraoperator reproducibility was observed for the standardized ultrasound liver‐to‐thoracic area ratio (intraclass correlation coefficient, 0.78). Good agreement among sonographers and the physician was also observed for the standardized measurements (bias, 0.01; precision, 0.03; limits of agreement, –0.05 to + 0.07).ConclusionsWe demonstrated that good intraoperator and interoperator reproducibility of ultrasound liver‐to‐thoracic area ratio assessment is feasible after standardizing the method in our center.
Reproducibility of Lung‐to‐Head Ratio Ultrasound Measurements in Congenital Diaphragmatic Hernia
Novoa, Victoria Arruga Novoa y, Sutton, Laura F., Neis, Allan E., Marroquin, Amber M., Freimund, Tamara A., Coleman, Tracey M., Praska, Kathleen A., Ruka, Krystal L., Warzala, Vicki L., Sangi‐Haghpeykar, Haleh , Novoa Y Novoa, Victoria Arruga, Ruano, Rodrigo , Ruano, Rodrigo

Journal of Ultrasound in Medicine | February 5, 2018 | Volume: 37 | Issue: 8 | Pages: 2037-2041

10.1002/jum.14557 Get It

ObjectivesThis study investigated the reproducibility of standardization of lung‐to‐head ratio measurements in congenital diaphragmatic hernia (CDH) at our center among sonographers after we standardized the method.MethodsWe reviewed ultrasound images of 12 fetuses with CDH at Mayo Clinic from 2010 to 2016. Nine operators (1 maternal‐fetal medicine specialist with experience in measuring the lung‐to‐head ratio and 8 sonographers), who were blinded to previous findings, reviewed 33 selected images from 12 fetuses with left CDH. The method for lung‐to‐head ratio measurement was standardized before starting the measurements. The lung‐to‐head ratio was assessed by different methods to obtain the lung areas: anteroposterior, longest, and area tracing. We evaluated the correlation between operators using the intraclass correlation coefficient (ICC). We also compared agreement between the sonographers and a physician with experience in measuring the lung‐to‐head ratio using a Bland‐Altman analysis.ResultsThe methods with the best interoperator reproducibility were the standardized anteroposterior lung‐to‐head ratio (ICC, 0.69) and the standardized lung‐to‐head ratio tracing (ICC, 0.65) compared to the longest lung‐to‐head ratio (ICC, 0.56). The standardized lung‐to‐head ratio tracing had the best agreement among sonographers and the physician (bias, 0.11; limits of agreement, −0.27 to +0.49) than the anteroposterior lung‐to‐head ratio (bias, 0.35; limits of agreement, −0.13 to + 0.83) and the longest lung‐to‐head ratio (bias, 0.27; limits of agreement, −0.35 to +0.89).ConclusionsWe demonstrated that the lung‐to‐head ratio tracing method has high interoperator reproducibility and the best agreement among the operators at our center. Further multicenter studies are necessary to confirm our results.
Are ultrasound renal aspects associated with urinary biochemistry in fetuses with lower urinary tract obstruction?
Nassr, Ahmed A. , Koh, Chester J. , Shamshirsaz, Alireza A. , Espinoza, Jimmy , Sangi‐Haghpeykar, Haleh , Sharhan, Dina, Welty, Stephen E. , Angelo, Joseph , Roth, David R. , Belfort, Michael A. , Braun, Michael , Ruano, Rodrigo , Espinoza, J

Prenatal Diagnosis | November 14, 2016 | Volume: 36 | Issue: 13 | Pages: 1206-1210

10.1002/pd.4958 Get It

AbstractObjectiveTo evaluate the association between ultrasonographic renal parameters and urine biochemistry in fetuses with lower urinary tract obstruction (LUTO).MethodsData were collected prospectively from 31 consecutive fetuses with LUTO that underwent vesicocentesis for fetal urinary biochemistry between April 2013 and September 2015. The following renal ultrasound markers were assessed immediately before the vesicocentesis: renal echogenicity, presence of cortical cysts, presence of findings suggestive of ‘renal dysplasia’ (hyperechogenic cystic kidneys with no cortical‐medullary differentiation) and severe oligohydramnios (amniotic fluid < 5th percentile). The association of these parameters to the fetal urinary concentration of sodium, chloride, calcium, osmolality and beta2‐microglobulin was investigated by logistic regression analysis.ResultsThere was no relationship between any of the ultrasonographic fetal renal characteristics and fetal urinary biochemistry.ConclusionsIn LUTO, the ultrasound appearance of the fetal kidneys and urinary biochemistry are not correlated. It may be better to take both ultrasound and biochemistry into account when evaluating fetuses with fetal LUTO. © 2016 John Wiley & Sons, Ltd.
Pregnant patients' risk perception of prenatal test results with uncertain fetal clinical significance: ultrasound versus advanced genetic testing
Richards, Elliott G. , Sangi‐Haghpeykar, Haleh , Veyver, Ignatia B. Van den , Fruhman, Gary , McGuire, Amy L

Prenatal Diagnosis | August 19, 2015 | Volume: 35 | Issue: 12 | Pages: 1213-1217

10.1002/pd.4680 Get It

AbstractObjectiveA common concern of utilizing prenatal advanced genetic testing is that a result of uncertain clinical significance will increase patient anxiety. However, prenatal ultrasound may also yield findings of uncertain significance, such as ‘soft markers’ for fetal aneuploidy, or findings with variable prognosis, such as mild ventriculomegaly. In this study we compared risk perception following uncertain test results from each modality.MethodsA single survey with repeated measures design was administered to 133 pregnant women. It included ‘intolerance of uncertainty’ questions, two hypothetical scenarios involving prenatal ultrasound or advanced genetic testing, and response questions. The primary outcome was risk perception score.ResultsRisk perception did not vary significantly between ultrasound and genetic scenarios (p = 0.17). The genetic scenario scored a higher accuracy (p = 0.04) but lower sense of empowerment (p = 0.01). Furthermore, patients were more likely to seek additional testing after an ultrasound than after genetic testing (p = 0.05). There were no differences in other secondary outcomes including perception of life‐altering consequences and hypothetical worry, anxiety, confusion, or medical care decisions.ConclusionsOur data suggest that uncertain findings on prenatal genetic testing do not elicit a higher perception of risk or anxiety when compared to ultrasound findings of comparable uncertainty. © 2015 John Wiley & Sons, Ltd.