Back to Authors

Harmsen, Scott

Mayo Clinic

Mayo Clinic

Citations 4

Response Rates of Invasive Lobular Cancer in Patients Undergoing Neoadjuvant Endocrine or Chemotherapy
Jakub, James W. , Zhang, Wenexia , Solanki, Malvika , Harmsen, Scott, Zhang, Wenxia , Yonkus, Jennifer, Jakub, James W , Yonkus, Jennifer A. , Boughey, Judy C. , Giridhar, Karthik V.

The American Surgeon™ | October 28, 2022 | Volume: 89 | Issue: 2 | Pages: 230-237

10.1177/00031348221135778 Get It

Background A gap remains in the role of neoadjuvant therapy for patients with ILC. Method Single-institution retrospective review of patients with ILC who received neoadjuvant therapy between 2008 and 2019. Results 141 patients met inclusion criteria: 71 neoadjuvant chemotherapy (NACT) and 70 neoadjuvant endocrine therapy (NET). 7/71 (9.9%) patients had a pCR following NACT compared to 1/70 (1.4%) with NET ( P = .063). pCR was observed in 5/18 (27.8%) patients with Her2Neu-positive disease following NACT, compared to 2/53 (3.8%) with Her2Neu-negative disease ( P = .01). For luminal B tumors, median Ki-67 decrease was similar following NACT and NET (18.3 vs 16.3, P = .26). T category decreased in 59 (42.1%) patients following neoadjuvant therapy, increased in 9 (6.4%), and was unchanged in 72 (51.4%). More patients had an increase (28.6%) than decrease (12.1%) in their N category, including 13/60 (21.7%) who were clinically node-negative at diagnosis and identified to have node-positive disease following neoadjuvant therapy, at definitive surgery. Conclusion In Her2Neu-negative ILC, the potential of a pCR with NACT or NET is low. Most patients’ nodal status and tumor size remain unchanged. There is a potential for pathologic stage to be higher at surgery compared to the clinical stage prior to neoadjuvant therapy.
Intraductal Papillary Mucinous Neoplasms of the Pancreas: CT Patterns of Recurrence and Multiobserver Performance in Detecting Recurrent Neoplasm After Surgical Resection
Christensen, Jared A. , Fidler, Jeff L. , Wold, Peter B., Binstock, Aaron J., Smyrk, Thomas C. , Harmsen, Scott, Crownhart, Brian S., Chari, Suresh T. , Fletcher, Joel G. , Fidler, Jeff L. , Chari, Suresh T

American Journal of Roentgenology | February 28, 2013 | Volume: 183 | Issue: 5 | Pages: 1367-1374

10.2214/ajr.183.5.1831367 Get It

Culture with BACTEC Peds Plus/F Bottle Compared with Conventional Methods for Detection of Bacteria in Synovial Fluid
Vetter, Emily A., Patel, Robin , Schleck, Cathy D. , Harmsen, Scott, Turgeant, L. Thomas, Cockerill, Franklin R., Hughes, John , Patel, Robin

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 12 | Pages: 4468-4471

10.1128/jcm.39.12.4468-4471.2001 Get It

ABSTRACT An evaluation was undertaken to determine the utility of the BACTEC Peds Plus/F bottle and the BACTEC 9240 instrument (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) for the detection of clinically significant microorganisms in synovial fluid specimens. The Peds Plus/F bottle was used because in our laboratory the quantity of synovial fluid available for culture is frequently in the range of 0.5 to 3.0 ml. The culture results obtained with the Peds Plus/F bottle were compared to those obtained by a conventional agar plate method for a total of 805 synovial fluid specimens. Microbial growth was produced by 74 cultures (9.2%) from 60 patients, yielding a total of 77 microorganisms. Organisms were classified as pathogens ( n = 62), contaminants ( n = 12), or indeterminate ( n = 3) on the basis of a review of the patients' medical histories. Culture using BACTEC Peds Plus/F bottle detected statistically significantly more pathogens overall (62 versus 51 pathogens [ P = 0.001]) and statistically fewer contaminants overall (1 versus 11 contaminants [ P = 0.006]) than culture by the agar plate method. These results indicate the superior performance of the BACTEC Peds Plus/F bottle over the conventional agar plate method for the detection of clinically significant microorganisms from synovial fluid specimens.
Comparison of the BACTEC MYCO/F Lytic Bottle to the Isolator Tube, BACTEC Plus Aerobic F/Bottle, and BACTEC Anaerobic Lytic/10 Bottle and Comparison of the BACTEC Plus Aerobic F/Bottle to the Isolator Tube for Recovery of Bacteria, Mycobacteria, and Fungi
Vetter, Emily A., Torgerson, C A, Feuker, A., Harmsen, Scott, Schleck, Cathy D. , Horstmeier, C D, Roberts, Glenn D., Cockerill, Franklin R., Hughes, John

Journal of Clinical Microbiology | July 27, 2002 | Volume: 39 | Issue: 12 | Pages: 4380-4386

10.1128/jcm.39.12.4380-4386.2001 Get It

ABSTRACT The BACTEC MYCO/F Lytic blood culture bottle (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) is designed to optimize the recovery of fungi and mycobacteria; however, this bottle also supports the growth of most aerobic bacteria. We compared the MYCO/F Lytic bottle with two other BACTEC bottles and the Isolator system for the recovery of bacteria as well as fungi and mycobacteria from blood. A total of 6,108 blood culture sets were inoculated with blood obtained from adult patients. Twenty-five to 28 ml of blood collected by a phlebotomy team for each blood culture set was randomly distributed into each of four blood culture receptacles: the Isolator tube (Wampole Laboratories, Cranbury, N.J.) and three BACTEC bottles: the MYCO/F Lytic bottle, the BACTEC Plus Aerobic/F bottle, and the BACTEC Anaerobic Lytic/10 bottle. The sediment from the Isolator tube was inoculated onto chocolate agar (CA), brain heart infusion agar (BHI), and Sabouraud dextrose agar (SDA) and into a BACTEC 13A bottle. Incubation durations were as follows: MYCO/F Lytic bottle, 42 days; Plus Aerobic/F bottle, 5 days; Anaerobic Lytic/10 bottle, 5 days; sediment from Isolator tube on CA, 3 days; sediment from Isolator tube on BHI, 30 days; sediment from Isolator tube on SDA, 30 days; and sediment from Isolator tube in a BACTEC 13A bottle, 42 days. Two isolates of Histoplasma capsulatum were recovered from the Isolator tube only. Three isolates of Mycobacterium tuberculosis complex were recovered: two isolates from the MYCO/F Lytic bottle only and one isolate from the Isolator tube (whose sediment was inoculated into the BACTEC 13A bottle) only. Two isolates of Cryptococcus neoformans were recovered: one from the MYCO/F Lytic bottle only and the other from the MYCO/F Lytic bottle and the Isolator tube (whose sediment was inoculated into the BACTEC 13A bottle). For potential pathogens overall, there was a statistical difference in recovery that favored the Isolator system over the MYCO/F Lytic bottle ( P = 0.0015), including statistically significant differences for Staphylococcus aureus ( P = 0.0001) and Streptococcus pneumoniae ( P = 0.0313). However, there was no statistically significant difference between the two blood culture systems when detection of bloodstream infection was considered. The time to detection for all potential pathogens combined was less for the MYCO/F Lytic bottle than for the Isolator system ( P = 0.0004). Overall, the potential pathogen recovery was greater for the BACTEC Plus Aerobic/F bottle than for either the Isolator system ( P = 0.0003) or the MYCO/F Lytic bottle ( P = 0.0001). However, the BACTEC Plus Aerobic/F bottle did not recover M. tuberculosis , H. capsulatum , or C. neoformans isolates. The combination of the Isolator system and MYCO/F Lytic bottle may be useful as a selective blood culture method to optimize the recovery of fungi and mycobacteria from blood. Compared with the manual Isolator system, the MYCO/F Lytic system has the advantage of less preanalytic processing and continuous automated monitoring of bottles for growth by the BACTEC 9240 instrument.