Back to Authors

Smith, Thomas F.

Mayo Clinic

Mayo Clinic

Citations 64

Detection of herpes simplex virus in conventional tube cell cultures and in shell vials with a DNA probe kit and monoclonal antibodies
Espy, Mark J., Smith, Thomas F.

Journal of Clinical Microbiology | January 5, 2020 | Volume: 26 | Issue: 1 | Pages: 22-24

10.1128/jcm.26.1.22-24.1988 Get It

Specimens submitted for diagnosis of herpes simplex virus (HSV) infection were inoculated into shell vials and reacted with a commercial DNA probe kit (Pathogene; Enzo Biochem, Inc., New York, N.Y.) and an immunofluorescence assay at 16 h postinoculation. The results were compared with isolation of the virus in conventional tube cell cultures. Of 504 specimens, 105 (20.8%) were positive for HSV. Of the 105, 93 HSV-positive specimens (89%) were detected by all three assay systems. Maximum detection of HSV (100 of 105 [95%]) was obtained by probe or monoclonal antibody assay in shell vials, which had sensitivities of 98 and 97%, respectively, compared with viral recovery in conventional tube cell cultures (mean time for recognition of cytopathic effects, 2 days). Both shell vial assays were 99% specific. The DNA probe kit may be used as an alternative to a monoclonal antibody and fluorescence assay in shell vials as a diagnostic method for rapid laboratory detection of HSV infection.
Evaluation of the COBAS AMPLICOR CMV MONITOR Test for Detection of Viral DNA in Specimens Taken from Patients after Liver Transplantation
Sia, Irene G. , Espy, Mark J., Payá, Carlos V., Smith, Thomas F., Sia, Irene G , Wilson, Jennie

Journal of Clinical Microbiology | December 31, 2019 | Volume: 38 | Issue: 2 | Pages: 600-606

10.1128/jcm.38.2.600-606.2000 Get It

ABSTRACT Detection of cytomegalovirus (CMV) DNA in blood by PCR is a sensitive method for the detection of infection in patients posttransplantation. The test, however, has low specificity for the identification of overt CMV disease. Quantitative CMV PCR has been shown to overcome this shortcoming. The COBAS AMPLICOR CMV MONITOR test was evaluated by using consecutive serum and peripheral blood mononuclear cell (PBMN) samples from liver transplant patients. Twenty-five patients had CMV viremia (by shell vial cell culture assay) and/or tissue-invasive disease (by biopsy); 20 had no active infection. A total of 262 serum and 62 PBMN specimens were tested. Of 159 serum specimens from patients with overt CMV infection, the COBAS assay detected CMV DNA in 21 patients (sensitivity, 84%). Only 1 of 103 samples from patients with no evidence of active infection had detectable CMV DNA (341 copies/ml). By comparison of 62 matching serum and PBMN samples by the same assay, 12 PBMN samples were exclusively positive, whereas only 2 serum samples were exclusively positive (P < 0.05). At the time of clinical CMV infection, viral copy numbers were higher in PBMNs than serum from four of five patients. The COBAS AMPLICOR CMV MONITOR test is a sensitive and specific test for the quantitative detection of CMV DNA in blood. Clinical applications of the assay will require further validation with samples from a larger population of transplant patients.
Analytical Performance and Clinical Utility of a Nucleic Acid Sequence-Based Amplification Assay for Detection of Cytomegalovirus Infection
Witt, Donald J., Kemper, Marti, Stead, Andrew, Sillekens, Peter, Ginocchio, Christine C. , Espy, Mark J., Payá, Carlos V., Smith, Thomas F., Roeles, Frits, Caliendo, Angela M.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 38 | Issue: 11 | Pages: 3994-3999

10.1128/jcm.38.11.3994-3999.2000 Get It

ABSTRACT A nucleic acid sequence-based amplification (NASBA) assay for qualitative detection of human cytomegalovirus (CMV) pp67 mRNA was evaluated in a multicenter study. Negative results were obtained for all specimens from 50 CMV-seronegative and 50 CMV-seropositive low-risk whole-blood donors. No interference with CMV mRNA amplification was observed in the testing of 288 specimens containing various potential interfering substances, nonspecifically reacting substances (including mRNA from other herpesviruses), and three anticoagulants. A total of 95% (50 of 51) of CMV-positive (cell culture- and antigenemia immunofluorescence [AG-IFA]-positive) clinical specimens were positive by the NASBA assay. Results from different operators over multiple testing days were consistent for each of four panel members containing different concentrations of CMV mRNA, indicating the reproducibility of the assay. The estimated 95% reliable upper detection limit of the assay was 600 mRNA copies; the lower limit of detection was less than 25 mRNA copies. The clinical utility of the assay was evaluated with longitudinally collected specimens from solid-organ transplant patients ( n = 21). A total of 98% (81 of 83) of the specimens from CMV-negative patients were negative by the NASBA assay, while 90% (10 of 11) of patient specimens that were positive by cell culture or AG-IFA were positive by the NASBA assay. Positive NASBA assay results were obtained earlier than AG-IFA or cell culture results for 55% of the patients and at the same time for the remainder of the patients (45%). The overall agreement between the NASBA assay and current reference tests was 86% when active CMV infection was present. These studies indicate that the CMV pp67 mRNA NASBA assay has reproducible and sensitive performance characteristics that should enable more rapid diagnosis of CMV infection.
Molecular Diagnosis of Herpes Simplex Virus Infections in the Central Nervous System
Mitchell, P. Shawn, Espy, Mark J., Smith, Thomas F., Persing, David H., Tang, Yi‐Wei

Journal of Clinical Microbiology | December 31, 2019 | Volume: 37 | Issue: 7 | Pages: 2127-2136

10.1128/jcm.37.7.2127-2136.1999 Get It

Clinical Comparison of the Treponema pallidum CAPTIA Syphilis-G Enzyme Immunoassay with the Fluorescent Treponemal Antibody Absorption Immunoglobulin G Assay for Syphilis Testing
Halling, Valerie W., Jones, Mary F. , Bestrom, Jean E., Wold, Arlo D., Rosenblatt, Jon E., Smith, Thomas F., Cockerill, F. R., Cockerill, Franklin R.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 37 | Issue: 10 | Pages: 3233-3234

10.1128/jcm.37.10.3233-3234.1999 Get It

ABSTRACT Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTIA-positive samples (antibody indices of ≥0.650 and ≤0.900) were retested; if the second analysis produced an index of >0.900, the sample was considered positive. Thirteen of 89 (15%) samples had discrepant results. Compared to the FTA-ABS assay, the CAPTIA EIA had a sensitivity and specificity and positive and negative predictive values of 70.7, 97.9, 96.7, and 79.7%, respectively. In another analysis, discrepancies between results were resolved by repeated FTA-ABS testing (technologists were blinded to previous RPR results) and patient chart reviews. Seven CAPTIA-negative samples which were previously interpreted (unblinded) as minimally reactive by the FTA method were subsequently interpreted (blinded) as nonreactive. One other discrepant sample (CAPTIA negative and FTA-ABS positive [at an intensity of 3+], unblinded) was FTA negative with repeated testing (blinded). For the five remaining discrepant samples, chart reviews indicated that one patient (CAPTIA negative and FTA-ABS positive [minimally reactive], blinded) had possible syphilis. These five samples were also evaluated and found to be negative by another treponema-specific test, the Treponema pallidum microhemagglutination assay. Therefore, after repeated testing and chart reviews, 2 of the 89 (2%) samples had discrepant results; the adjusted sensitivity, specificity, and positive and negative predictive values were 96.7, 98.3, 96.7, and 98.3%, respectively. This study demonstrates that the CAPTIA IgG EIA is a reliable method for syphilis testing and that personnel performing tests which require subjective interpretation, like the FTA-ABS test, may be biased by RPR test results.
Comparative Evaluation of Colorimetric Microtiter Plate Systems for Detection of Herpes Simplex Virus in Cerebrospinal Fluid
Rys, Paul N., RUTLEDGE, BARBARA J., Mitchell, P. Shawn, Smith, Thomas F., Persing, David H., Tang, Yi‐Wei

Journal of Clinical Microbiology | December 31, 2019 | Volume: 36 | Issue: 9 | Pages: 2714-2717

10.1128/jcm.36.9.2714-2717.1998 Get It

ABSTRACT In the past few years, application of the PCR to the detection of herpes simplex virus (HSV) DNA in the cerebrospinal fluid (CSF) from patients with encephalitis and meningitis has become standard laboratory practice. However, from an operational perspective, the true diagnostic value of PCR in this setting is yet to be realized because most laboratories subject the amplification products to lengthy probe hybridization procedures by Southern blotting. As alternatives to Southern blotting, we evaluated colorimetric microtiter plate (MTP) systems from ViroMed Laboratories, Inc. (PrimeCapture), CPG, Inc. (Quanti-PATH), and Incstar Corp. (GEN-ETI-K), in addition to a system developed at the Mayo Clinic with the PCR ELISA system (Boehringer Mannheim Corp.). We tested PCR products from 86 clinical CSF specimens submitted to our Molecular Microbiology Laboratory. The CSF specimens used had to have sufficient volume for comparative analysis. By conventional Southern blotting methods, 54 were positive and 32 were negative for HSV DNA. Compared with Southern blotting, the sensitivity and specificity were 63.0 and 100.0%, respectively, for the PrimeCapture system, 98.2 and 96.9%, respectively, for the Quanti-PATH system, 98.2 and 100.0%, respectively, for the GEN-ETI-K system, and 100.0 and 96.9%, respectively, for the Mayo system. All four MTP systems had turnaround times 12 to 24 h less than that for Southern blotting. There were no significant differences in costs or technologist time between the Mayo system and Southern blotting. Other features of the Mayo system include type-specific genotypic identification of HSV and the potential for determination of drug resistance by DNA sequencing. Overall, we found that colorimetric MTP systems were likely to improve test turnaround times and patient care at no additional cost.
Detection and Semiquantitative Analysis of Human Herpesvirus 8 DNA in Specimens from Patients with Kaposi’s Sarcoma
Mendez, Julio, Procop, Gary W. , Espy, Mark J., Paya, C. V., Smith, Thomas F.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 36 | Issue: 8 | Pages: 2220-2222

10.1128/jcm.36.8.2220-2222.1998 Get It

ABSTRACT Kaposi’s sarcoma (KS) is the most common neoplasm in patients with AIDS. Epidemiologic evidence and the recent identification of herpesvirus-like DNA sequences in patients with KS have suggested a role for viral agents in the etiopathogenesis of this disease. It is unclear if these sequences are present in all types of KS and if the copy number of these sequences has a correlation with disease severity (staging). In order to clarify these issues, we retrospectively analyzed, by PCR and Southern blotting, formalin-fixed, paraffin-embedded biopsy specimens from 12 patients previously diagnosed with KS by histopathologic examination of these specimens between the years of 1977 and 1996. We also analyzed tissue samples from these patients taken from dermal sites without KS lesions and control tissues from healthy subjects. Of the 12 patients, 6 had classic KS, 5 had AIDS-associated KS, and 1 had the endemic type of KS. We tested the specimens for other herpesviruses, including cytomegalovirus, human herpesvirus 6 (HHV-6), HHV-7, HHV-8, and Epstein-Barr virus. Of 20 biopsy specimens from patients previously diagnosed with KS, 19 were positive for HHV-8 sequences (95%), while PCR for the DNAs of other herpesvirus agents was negative. Uninvolved tissue from these patients and control tissue from healthy subjects gave negative results for all viruses. Semiquantitative analysis of Southern blots showed higher levels of HHV-8 DNA in those patients with multicentric and visceral involvement than in those patients with localized involvement. In addition, in patients with localized skin disease, the nodular stage had higher levels of HHV-8 DNA than the patch or plaque stages. Our data confirmed that HHV-8 is involved in the etiopathogenesis of all types of KS and that there is a correlation between HHV-8 DNA load and the severity and staging of this disease.
Use of Lambda Phage DNA as a Hybrid Internal Control in a PCR-Enzyme Immunoassay To Detect Chlamydia pneumoniae
Pham, Dien G., Madico, Guillermo, Quinn, Thomas C. , Enzler, Mark J., Smith, Thomas F., Gaydos, Charlotte A.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 36 | Issue: 7 | Pages: 1919-1922

10.1128/jcm.36.7.1919-1922.1998 Get It

ABSTRACT An inherent problem in the diagnostic PCR assay is the presence of ill-defined inhibitors of amplification which may cause false-negative results. Addition of an amplifiable fragment of foreign DNA in the PCR to serve as a hybrid internal control (HIC) would allow for a simple way to identify specimens containing inhibitors. Two oligonucleotide hybrid primers were synthesized to contain nucleic acid sequences of the Chlamydia pneumoniae 16S rRNA primers in a position flanking two primers that target the sequences of a 650-bp lambda phage DNA segment. By using the hybrid primers, hybrid DNA comprising a large sequence of lambda phage DNA flanked by short pieces of chlamydia DNA was subsequently generated by PCR, cloned into a plasmid vector, and purified. Plasmids containing the hybrid DNA were diluted and used as a HIC by adding them to each C. pneumoniae PCR test. Consequently, C. pneumoniae primers were able to amplify both chlamydia DNA and the HIC DNA. The production of a 689-bp HIC DNA band on an acrylamide gel indicated that the specimen contained no inhibitors and that internal conditions were compatible with PCR. Subsequently, a biotinylated RNA probe for the HIC was transcribed from a nested sequence of the HIC and was used for its hybridization. Detection of the HIC DNA-RNA hybrid was achieved by enzyme immunoassay (EIA). This PCR-EIA system with a HIC was initially tested with 12 previously PCR-positive and 14 previously PCR-negative specimens. Of the 12 PCR-positive specimens, 11 were reconfirmed as positive; 1 had a negative HIC value, indicating inhibition. Of the 14 previously PCR-negative specimens, 13 were confirmed as true negative; 1 had a negative HIC value, indicating inhibition. The assay was then used with 237 nasopharyngeal specimens from patients with pneumonia. Twenty-one of 237 (8.9%) were positive for C. pneumoniae , and 42 (17.7%) were found to inhibit the PCR. Specimens showing inhibitory activity were diluted 1:10 and were retested. Ten specimens were still inhibitory to the PCR and required further DNA purification. No additional positive samples were detected and 3 nasopharyngeal specimens remained inhibitory to PCR. Coamplification of a HIC DNA can help confirm true-negative PCR results by ruling out the presence of inhibitors of DNA amplification.
Evaluation of PCR Primers for Early Diagnosis of Cytomegalovirus Infection following Liver Transplantation
Mendez, Julio, Espy, Mark J., Smith, Thomas F., Payá, Carlos V., Wilson, Jennie

Journal of Clinical Microbiology | December 31, 2019 | Volume: 36 | Issue: 2 | Pages: 526-530

10.1128/jcm.36.2.526-530.1998 Get It

ABSTRACT The availability of microbiologic methods that detect early replication of cytomegalovirus (CMV) posttransplantation will enhance the process of initiating preemptive antiviral therapy prior to the appearance of CMV disease. Using PCR techniques we sought to determine which region of the CMV genome present in peripheral blood leukocytes (PBLs) or serum provides the highest sensitivity for the detection of CMV posttransplantation. Blood samples were prospectively collected weekly for at least 8 weeks from a cohort of 21 consecutive liver transplant recipients not receiving anti-CMV prophylaxis. Results of PCR assays were correlated with recovery of CMV in cell cultures and histopathological findings from biopsy specimens of infected organs to assess clinical symptomatic infection. Of 148 specimens, primer pairs directed to the Hin dIII-X fragment region of CMV detected target DNA with a 94% sensitivity, compared to an 87% sensitivity with primer pairs directed to Eco RI fragment D, 32% sensitivity with primer pairs directed to the immediate-early antigen 1 gene (IEA1 gene), and 20% sensitivity with primer pairs directed to the major immediate-early (MIE) gene. The performance characteristics in terms of the sensitivity of primers for amplifying CMV DNA associated with symptomatic infection ranged from 100% ( Hin dIII-X) to 20% (MIE gene); however, specificity was inversely related ( Hin dIII-X, 45%; MIE gene, 91%) to primers directed to these gene targets. When Hin dIII-X and Eco RI-D primer sets were used, CMV DNA from PBLs was a more sensitive target than CMV DNA from serum for the early detection of symptomatic CMV infection (17 versus 12 days). Importantly, CMV DNA was not detected in five patients with no evidence of this viral infection. In conclusion, primers directed to the Hin dIII-X fragment region were the most optimal for the early detection of CMV DNA in PBLs and sera from symptomatic liver transplant recipients.
Evaluation of LightCycler PCR for Implementation of Laboratory Diagnosis of Herpes Simplex Virus Infections
Espy, Mark J., Ross, Teri K., Teo, Rosaline, Svien, Kathleen A., Wold, Arlo D., Uhl, James R., Smith, Thomas F.

Journal of Clinical Microbiology | December 31, 2019 | Volume: 38 | Issue: 8 | Pages: 3116-3118

10.1128/jcm.38.8.3116-3118.2000 Get It

ABSTRACT Five hundred specimens (288 genital, 192 dermal, and 20 ocular) were extracted by technologists, and the DNA was assayed by LightCycler PCR (DNA polymerase and thymidine kinase [TK] gene targets) and by conventional tube and shell vial cell culture. One hundred fifty-eight confirmed (by cell culture and TK target PCR) positive and LightCycler-positive specimens were detected during the first 30 PCR cycles. LightCycler PCR-positive results for cycles 31 to 45 (39 of 67 [58.2%]) required confirmation by another PCR target (TK). LightCycler PCR is more sensitive ( n = 197; 23.1%) than cell cultures ( n = 150) for the routine laboratory detection of herpes simplex virus infections.