Back to Authors

Zhou, Yuxiang

https://orcid.org/0000-0002-3462-2305

Mayo Clinic

Mayo Clinic in Arizona

Citations 31

Deep residual inception encoder‐decoder network for amyloid PET harmonization
Shah, Jay , Gao, Fei , Ghisays, Valentina , Luo, Ji , Chen, Yinghua , Lee, Wendy , Zhou, Yuxiang, Reiman, Eric M. , Li, Baoxin , Zhou, Yuxiang , Benzinger, Tammie L.S. , Chen, Kewei , Su, Yi , Wu, Teresa

Alzheimer's & Dementia | February 10, 2022 | Volume: 18 | Issue: 12 | Pages: 2448-2457

10.1002/alz.12564 Get It

AbstractIntroductionMultiple positron emission tomography (PET) tracers are available for amyloid imaging, posing a significant challenge to consensus interpretation and quantitative analysis. We accordingly developed and validated a deep learning model as a harmonization strategy.MethodA Residual Inception Encoder‐Decoder Neural Network was developed to harmonize images between amyloid PET image pairs made with Pittsburgh Compound‐B and florbetapir tracers. The model was trained using a dataset with 92 subjects with 10‐fold cross validation and its generalizability was further examined using an independent external dataset of 46 subjects.ResultsSignificantly stronger between‐tracer correlations (P < .001) were observed after harmonization for both global amyloid burden indices and voxel‐wise measurements in the training cohort and the external testing cohort.DiscussionWe proposed and validated a novel encoder‐decoder based deep model to harmonize amyloid PET imaging data from different tracers. Further investigation is ongoing to improve the model and apply to additional tracers.
Editorial for “Elaboration of Multiparametric MRI‐Based Radiomics Signature for the Preoperative Quantitative Identification of the Histological Grade in Patients With Non‐Small‐Cell Lung Cancer”
Li, Zhiqiang , Zhou, Yuxiang , Srivastava, Shiv P., Zhou, Yuxiang

Journal of Magnetic Resonance Imaging | January 4, 2022 | Volume: 56 | Issue: 2 | Pages: 590-591

10.1002/jmri.28052 Get It

Real-Time MRI–Guided Stereotactic Aspiration of Spontaneous Intracerebral Hematoma: A Preclinical Feasibility Study
Patra, Devi Prasad, Welz, Matthew E., Turcotte, Evelyn L. , Pandey, Rajesh, Vij, Kamal, Daly, Max, Rabon, Matthew , Korszen, Stephanie, Halpin, Brooke S. , Marchese, Marco L., Syal, Arjun , Krishna, Chandan , Patra, Devi P. , Bendok, Bernard R , Pandey, Rajesh, Zhou, Yuxiang , Bendok, Bernard R.

Operative Neurosurgery | December 22, 2021 | Volume: 22 | Issue: 2 | Pages: 80-86

10.1227/ons.0000000000000005 Get It

BACKGROUND: Minimally invasive surgical techniques have reinvigorated the role of surgical options for spontaneous intracranial hematomas; however, they are limited by the lack of real-time feedback on the extent of hematoma evacuation. OBJECTIVE: To describe the development of a MRI-guided catheter-based aspiration system, the ClearPoint Pursuit Neuroaspiration Device (ClearPoint Neuro) and validation in phantom models. METHODS: In this preclinical experimental trial, 8 phantom brains with skull models were created to simulate an intracranial hematoma with 2 clot sizes, 30 cc (small clot) and 60 cc (large clot). After registration, the aspiration catheter (Pursuit device) was aligned to the desired planned trajectory. The aspiration of the clot was performed under real-time MRI scan in 3 orthogonal views. The primary end point was reduction of the clot volume to less than 15 cc or 70% of the original clot volume. RESULTS: Successful completion of clot evacuation was achieved in all models. The average postaspiration clot volume was 9.5 cc (8.7 cc for small clots and 10.2 cc for large clots). The average percentage reduction of clot volume was 76.3% (range 58.7%-85.2%). The average total procedure time (from frame registration to final postaspiration clot assessment) was 50 min. The average aspiration time was 6.9 min. CONCLUSION: This preclinical trial confirms the feasibility and efficacy of MRI-guided aspiration under real-time image guidance in simulation models for intracranial hematoma. Clinical use of the system in patients would further validate its efficacy and safety.
Editorial for “Short‐Term Repeatability of In Vivo Cardiac Intravoxel Incoherent Motion (IVIM) Tensor Imaging in Healthy Human Volunteers”
Zhou, Yuxiang , Jokerst, Clinton, Panda, Anshuman , Zhou, Yuxiang

Journal of Magnetic Resonance Imaging | November 19, 2021 | Volume: 55 | Issue: 6 | Pages: 1853-1854

10.1002/jmri.28001 Get It

Association of Breast Cancer Risk, Density, and Stiffness: Global Tissue Stiffness on Breast MR Elastography (MRE)
Patel, Bhavika , Pepin, Kay , Brandt, Kathy R., Pockaj, Barbara A. , Northfelt, Donald W. , Anderson, Karen R., Swanson, Kristin R. , Patel, Bhavika K , Swanson, Kristin R , Mazza, Gina L , Chen, Jun , Zhou, Yuxiang , Anderson, Karen, Kling, Juliana M. , Nikkhah, Mehdi , Ehman, Richard L.

No container title available | June 15, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-611943/v1 Get It

Abstract Purpose:Quantify in vivo biomechanical tissue properties in various breast densities and in normal risk and high risk women using Magnetic Resonance Imaging (MRI)/MRE and examine the association between breast biomechanical properties and cancer risk.Methods: Patients with normal risk or high risk of breast cancer underent 3.0 T breast MR imaging and elastography. Breast parenchymal enhancement (BPE), density (from most recent mammogram), stiffness, elasticity, and viscosity were recorded. Within each breast density group (non-dense versus dense), stiffness, elasticity, and viscosity were compared across risk groups (normal versus high). A multivariable logistic regression model was used to evaluate whether the MRE parameters (separately for stiffness, elasticity, and viscosity) predicted risk status after controlling for clinical factors.Results: 50 normal risk and 86 high risk patients were included. Risk groups were similar on age, density, and menopausal status. Among patients with dense breasts, mean stiffness, elasticity, and viscosity were significantly higher in high risk patients (N = 55) compared to normal risk patients (N = 34; all p < 0.001). Stiffness remained a significant predictor of risk status (OR=4.26, 95% CI [1.96, 9.25]) even after controlling for breast density, BPE, age, and menopausal status. Similar results were seen for elasticity and viscosity.Conclusion: A structurally-based, quantitative biomarker of tissue stiffness obtained from MRE is associated with differences in breast cancer risk in dense breasts. Tissue stiffness could provide a novel prognostic marker to help identify high risk women with dense breasts who would benefit from increased surveillance and/or risk reduction measures.
Global tissue stiffness on breast MR elastography: High-risk dense breast patients have higher stiffness compared to average-risk dense breast patients.
Pepin, Kay , Brandt, Kathy R., Pockaj, Barbara A. , Northfelt, Donald W. , Anderson, Karen S. , Ahmad, Sarwat , Millstine, Denise , Apsey, Heidi A., Vachon, Celine M. , Nelson, Ilyse, Patel, Bhavika , Mazza, Gina L , Chen, Jun , Zhou, Yuxiang , Ernst, Brenda , Cronin, Patricia A. , Kling, Juliana M. , Vachon, Celine M. , Ehman, Richard L.

Journal of Clinical Oncology | June 2, 2021 | Volume: 39 | Issue: 15_suppl | Pages: 10541-10541

10.1200/jco.2021.39.15_suppl.10541 Get It

10541 Background: Biomechanical tissue properties may vary in the breasts of patients at elevated risk for breast cancer. We aim to quantify in vivo biomechanical tissue properties in various breast densities and in both normal risk and high risk women using Magnetic Resonance Imaging (MRI)/MRE and examine the association of biomechanical properties of the breast with cancer risk. Methods: In this IRB–approved prospective single-institution study, we recruited two groups of women differing by breast cancer risk to undergo a 3.0 T dynamic contrast enhanced MRI/MRE of the breast. Low-average risk women were defined as having no personal or significant family history of breast cancer, no prior high risk breast biopsies and a negative mammography within 12 months. High-risk breast cancer patients were recruited from those patients who underwent standard of care breast MR. Within each breast density group (non-dense versus dense), two-sample t-tests were used to compare breast stiffness, elasticity, and viscosity across risk groups (low-average vs high). Results: There were 50 low-average risk and 86 high-risk patients recruited to the study. The risk groups were similar on age (mean age = 55.6 and 53.6 years), density (68% vs. 64% dense breasts) and menopausal status (66.0% vs. 69.8%). Among patients with dense breasts, mean stiffness, elasticity, and viscosity were significantly higher in high risk patients ( N = 55) compared to low-average risk patients ( N = 34; all p < 0.001). In the multivariate logistic regression model, breast stiffness remained a significant predictor of risk status (OR=4.26, 95% CI [1.96, 9.25]) even after controlling for breast density, MRI BPE, age, and menopausal status. Similar results were seen for breast elasticity (OR=4.88, 95% CI [2.08, 11.43]) and viscosity (OR=11.49, 95% CI [1.15, 114.89]). Conclusions: Structurally-based, quantitative biomarker of tissue stiffness obtained from global 3D breast MRE is associated with differences in breast cancer risk in dense breasts. As such, tissue stiffness could provide a novel prognostic marker to help identify the subset of high-risk women with dense breasts who would benefit from increased surveillance.[Table: see text]
Sample content of kinesthetic educational training: Reducing scattered X‐ray exposures to interventional physician operators of fluoroscopy
Pavlicek, William , Paden, Robert G., Panda, Anshuman , Hines, Justin K. , Naidu, Sailendra , Öklü, Rahmi , Sensakovic, William F. , Hines, Justin, Naidu, Sailendra G, Oklu, Rahmi , Zhou, Yuxiang , Hines, Justin

Journal of Applied Clinical Medical Physics | December 30, 2019 | Volume: 21 | Issue: 7 | Pages: 196-208

10.1002/acm2.12801 Get It

AbstractContent used by Medical Physicists for fluoroscopy safety training to staff is deliverable via several formats, that is, online content or a live audience slide presentations. Here, we share one example of a kinesthetic (live, hands‐on simulation) educational program in use at our facility for some time (~10 years). In this example, the format and content specifically target methods of reducing physician operator exposures from scattered x rays. A kinesthetic format identifies and promotes the adoption of exposure‐reducing behaviors. Key kinesthetic elements of this type of training include: physician hands‐on measurements of radiation levels at locations specific to their standing positions (e.g., primary arterial access points) in the room using handheld exposure rate meters, measurement of exposure rate reduction to physicians provided by using personal protective equipment, that is, wearable aprons, hanging lead drapes, and pull‐down shields. Physician choice of procedure‐specific tableside selectable controls affecting exposure rate from optional fluoroscopy, Cine or digital subtraction angiography (DSA), along with comparative measured contribution to physician exposure is demonstrated. The inverse square exposure rate reduction to physicians when stepping back from the table during DSA is a key observation. Kinesthetic simulations in the rooms used by physicians have been found to provide the highest level of understanding giving rise to adoption of practices that are impactful for physicians. Specific training scripts are in place for physician sub‐specialization in interventional radiology, cardiology, neurosurgery, vascular surgery, and gastroenterology. This training is used for new physician staff while classroom presentations (whose content mimics in room training) are used with staff who have had previously had in room training.
NIMG-50. DOES THE PRESENCE OF GADOLINIUM AFFECT T2 –WEIGHTED IMAGES OF GLIOMA?: IMPLICATIONS FOR MRI PROTOCOL STANDARDIZATION
Swanson, Kristin R. , Hu, Leland , Swanson, Kristin R , Jackson, Pamela , Zhou, Yuxiang , Hoxworth, Joseph M.

Neuro-Oncology | November 11, 2019 | Volume: 21 | Issue: Supplement_6 | Pages: vi172-vi172

10.1093/neuonc/noz175.719 Get It

Abstract There have been increasing efforts to standardize MRI scanning protocols for both routine and clinical trial imaging of glioma. The recent BTIP guidelines propose acquisition of T2-weighted images after gadiolinium (Gd) based contrast injection and before post-contrast 3D T1-weighted (T1W) images to control timing of images after contrast administration. While Gd-contrast shortens T1W signal and appears hyperintense on magnetic resonance imaging (MRI), Gd-contrast also shortens T2W signal, which could result in unintended alternations in T2W signal intensities. This has potential implications for model-based approaches for GBM diagnosis and the differential diagnosis of other tumor types (e.g., lymphoma) that rely on T2W signal characteristics. To our knowledge, no neuroimaging studies have formally evaluated the impact of Gd contrast on T2W imaging. We acquired multi-echo T2 sequences (TE=14, 28, 41, 55, 69 ms) both prior to and after the administration of Gd for 5 patients suspected of having a brain tumor. Quantitative T2 maps were created by fitting the signal decay to a signal exponential with the Levenburg-Marqurdt algorithm. Percent difference maps were calculated to compare the quantitative T2 changes between the pre- and post-Gd T2 maps. Additionally, we performed a Wilcoxon Rank-Sum test comparing T2 values within regions of interest (ROIs) representing the tumor and normal appearing white matter (NAWM). Significant differences between the T2 values in the tumor and NAWM ROIs were seen for 4 and 3 of the patients, respectively (all p-values < 0.01). Our initial data suggests that the administration of Gd contrast may affect T2 values in both the tumor and NAWM, which could impact quantitative image-based models and diagnoses in glioma. We are currently replicating these preliminary results in an expanded cohort.
NIMG-28. VALIDATION OF SINGLE-DOSE DSC-MRI PROTOCOLS FOR ROBUST PERFUSION ASSESSMENT IN BRAIN TUMORS
Quarles, C. Chad , Semmineh, Natenael , Fuentes, Alberto, Nespodzany, Ashley , Alhilai, Lea, Karis, John P. , Rand, Scott D. , Dardis, Chris, Braun, Kelly, Connelly, Jennifer , Hu, Leland , Boxerman, J. L., Stokes, Ashley M. , Bell, Laura C. , Prah, Melissa A. , Connelly, Jennifer , Zhou, Yuxiang , Schmainda, Kathleen M

Neuro-Oncology | November 11, 2019 | Volume: 21 | Issue: Supplement_6 | Pages: vi167-vi167

10.1093/neuonc/noz175.699 Get It

Abstract Dynamic susceptibility contrast (DSC) MRI measures of brain tumor cerebral blood volume (CBV) are able to predict grade, overall survival and response to treatment. Wide-spread acceptance of DSC-MRI has been challenged by the need to balance contrast agent dose and CBV accuracy. The goal of this study was to identify and validate single-dose, BTIP compliant, DSC-MRI protocols. Using a validated, patient-based DRO, we evaluated CBV accuracy across a range of acquisition parameters (field strength, TR, TE, flip angle, multi-echo acquisitions, dosing protocols) and post-processing steps. To validate the optimal protocols, we next collected DSC-MRI data following ASFNR’s recommended “double – dose” approach, where a single-dose preload (to minimize T1 effects) is given prior to a second bolus injection (for DSC-MRI data acquisition). The single-dose DSC-MRI data was collected during the preload bolus injection. Consistency of the derived CBV data, visual agreement and data characteristics (e.g. CNR) was statistically evaluated. When using a single-dose and routine single-echo pulse sequence, the DRO analysis found that a low flip angle (LFA = 30o) and 30ms TE provided the highest CBV accuracy (concordance correlation coefficient (CCC) = 0.92) and precision (coefficient of variation (CV) = 8.2%)). For comparison, the maximum accuracy found with the DRO utilizes a double-dose injection protocol and yielded a CCC of 0.98 and CV of 6.8%. Single-dose, multi-echo acquisitions provided higher accuracy than the LFA data and matched that found with the double-dose approach. In patients (data collection ongoing), the agreement between single-dose LFA (n > 40) or multi-echo (n > 40) based CBV values and the reference double-dose approach was very high (CCC > 0.94) and were statistically equivalent. Optimized single-dose DSC-MRI protocols provide highly accurate CBV data, use lower doses of contrast agent, and simplify scan procedures, indicating their potential for robust use in clinical practice and trials.