Abstract Objective To assess the performance and cost implications of contrast-enhanced mammography-guided biopsy (CEM Bx). Methods This is a prospective study from May 5, 2021, to April 18, 2022, across 2 U.S. academic centers, evaluating technical success, patient/radiologist feedback, and operational factors of CEM Bx. Inclusion criteria included that patients be 40 years or older and recommended for biopsy with suspicious findings on contrast-enhanced mammography (CEM). Descriptive statistics are reported for clinical outcomes, length of procedure, and user and participant feedback. An estimate of cost was made by comparing general Medicare costs that are being billed for CEM Bx and post-clip mammogram ($475.48) to the Medicare costs of MRI-guided biopsy (MRI Bx) and post-clip placement mammogram ($845.94). Results Eighty-two participants enrolled. Twenty-two were excluded at the time of CEM Bx (22/82, 27%). Sixty participants were included (mean age 57 years, range 33 to 81 years) with 63 suspicious CEM lesions. The malignancy rate was 22% (14/63). A technical success rate of 100% was achieved. Average CEM Bx time was 29% to 33% the average reported MRI-guided breast biopsy times (CEM Bx = 11 minutes; MRI Bx = 33 to 38 minutes), indicating operational efficiencies. A positive opinion of CEM Bx was reported by 78% of radiologists, 93% of technologists, and 98% of patients. The estimated cost for each CEM Bx was ~ 45% lower than MRI Bx. Conclusion CEM Bx demonstrates high success rates and satisfaction scores. CEM Bx resulted in shorter procedure times, enhanced operational efficiency, and ~45% reduction in costs compared with MRI Bx. As advancements continue, we anticipate CEM Bx will offer a cost-efficient and timely option for breast biopsy.
Prospective Study of Supplemental Screening With Contrast-Enhanced Mammography in Women With Elevated Risk of Breast Cancer: Results of the Prevalence Round
PURPOSE Contrast-enhanced mammography (CEM) and magnetic resonance imaging (MRI) have shown similar diagnostic performance in detection of breast cancer. Limited CEM data are available for high-risk breast cancer screening. The purpose of the study was to prospectively investigate the efficacy of supplemental screening CEM in elevated risk patients. MATERIALS AND METHODS A prospective, single-institution, institutional review board–approved observational study was conducted in asymptomatic elevated risk women age 35 years or older who had a negative conventional two-dimensional digital breast tomosynthesis screening mammography (MG) and no additional supplemental screening within the prior 12 months. RESULTS Four hundred sixty women were enrolled from February 2019 to April 2021. The median age was 56.8 (range, 35.0-79.2) years; 408 of 460 (88.7%) were mammographically dense. Biopsy revealed benign changes in 22 women (22/37, 59%), high-risk lesions in four women (4/37, 11%), and breast cancer in 11 women (11/37, 30%). Fourteen cancers (10 invasive, tumor size range 4-15 mm, median 9 mm) were diagnosed in 11 women. The overall supplemental cancer detection rate was 23.9 per 1,000 patients, 95% CI (12.0 to 42.4). All cancers were grade 1 or 2, ER+ ERBB2–, and node negative. CEM imaging screening offered high specificity (0.875 [95% CI, 0.844 to 0.906]), high NPV (0.998 [95% CI, 0.993 to 1.000), moderate PPV1 (0.164 [95% CI, 0.076 to 0.253), moderate PPV3 (0.275 [95% CI, 0.137 to 0.413]), and high sensitivity (0.917 [95% CI, 0.760 to 1.000]). At least 1 year of imaging follow-up was available on all patients, and one interval cancer was detected on breast MRI 4 months after negative screening CEM. CONCLUSION A pilot trial demonstrates a supplemental cancer detection rate of 23.9 per 1,000 in women at an elevated risk for breast cancer. Larger, multi-institutional, multiyear CEM trials in patients at elevated risk are needed for validation.
False-Positive and False-Negative Contrast-enhanced Mammograms: Pitfalls and Strategies to Improve Cancer Detection
Imaging Characteristics of and Multidisciplinary Management Considerations for Atypical Ductal Hyperplasia and Flat Epithelial Atypia: Review of Current Literature
Abstract Objective Evaluate women’s anxiety and experience undergoing screening mammography during the COVID-19 pandemic. Methods An IRB-approved anonymous survey was administered to women receiving screening mammography across six sites in the U.S. and Singapore from October 7, 2020, to March 11, 2021. Using a 1–5 Likert scale, women rated their pre- and post-visit anxiety regarding having their mammogram during the COVID-19 pandemic, importance of observed COVID-19 precautions, and personal risk factors for breast cancer and severe COVID-19 illness. Post-visit change in anxiety was evaluated. Multivariable logistic regression was used to test associations of pre-visit anxiety with breast cancer and COVID-19 risk factors. Results In total, 1086 women completed the survey. Of these, 59% (630/1061) had >1 breast cancer risk factor; 27% (282/1060) had >1 COVID-19 risk factors. Forty-two percent (445/1065) experienced pre-visit anxiety. Pre-visit anxiety was independently associated with risk factors for severe COVID-19 (OR for >2 vs 0 risk factors: 2.04, 95% confidence interval [CI]: 1.11–3.76) and breast cancer (OR for >2 vs 0 risk factors: 1.71, 95% CI: 1.17–2.50), after adjusting for age and site. Twenty-six percent (272/1065) of women reported post-visit anxiety, an absolute 16% decrease from pre-visit anxiety (95% CI: 14%–19%, P < 0.001). Provider masking (941/1075, 88%) and physical distancing (861/1085, 79%) were rated as the most important precautions. Conclusion Pre-visit anxiety was associated with COVID-19 or breast cancer risk factors and declined significantly after screening mammography. Provider masking and physical distancing were rated the most important precautions implemented by imaging clinics.
A Picture Is Worth a Thousand Words: RadioGraphics Visual Abstracts for Quick Learning
Abstract Background: Contrast-enhanced mammography (CEM) is an emerging breast imaging technique utilizing iodinated contrast to highlight areas of neovascularity. The role of CEM in patients with breast implants has not yet been characterized. We report our clinical experience of CEM in patients with breast augmentation surgery to better understand the potential diagnostic utility and limitations of CEM in the setting of breast implants. Materials and Methods: A HIPPA compliant, IRB exempt single-institution review of prospective CEM cases who had “breast implants” in their report between 01/2015 and 03/2020. Medical records were reviewed to supplement database information. Results: Forty-six patients were included with a mean age of 52 years (range 33-72). Clinical indications included: high risk research screen 3 (6%), diagnostic evaluation for abnormal imaging 24 (52%), further evaluation of newly diagnosed breast cancer 12 (26%) or assessment of neoadjuvant treatment response 7 (15%). Thirty patients had malignant lesions. Histology was invasive ductal carcinoma (90%), invasive lobular carcinoma (7%), and ductal carcinoma in situ (3%). CEM identified the index cancer and extent of disease in 28/30 (93%) of malignant cases. In two patients (7%), the malignant lesion was not included in the field-of-view due to its location. One of these lesions was a far medial mass within the breast which was detected by ultrasound alone. The other false negative CEM was a palpable axillary mass negative on both mammogram (MG) and MRI but seen by ultrasound. Twenty-three (50%) underwent additional breast MRI of which 20 had an already diagnosed cancer. the findings on CEM were concordant with MR imaging for the index lesion in 19/20 (95%) cases (kappa=0.86; p <0.001). Six additional lesions were found by CEM and confirmed by MRI. Of these lesions, 33% were found to be malignant and changed the surgical procedure. Four were only seen on CEM (no MRI comparison was available) and 75% were found to be malignant. One was only seen on MRI and was benign. One additional lesion was only seen as an asymmetry on MG without CEM or MRI correlate. This was benign on both the biopsy and surgical pathology. Conclusions: CEM appears to be a valuable breast imaging modality for diagnostic evaluations and surgical staging, including patients with breast implants. Due to technical artifacts and positioning limitations for posterior lesions, we recommend performing CEM with implant displaced views. Breast centers that use CEM, should be aware of field of view as a potential limitation when evaluating extent of disease in patients with breast augmentation. Citation Format: Molly Carnahan, Barbara Pockaj, Victor Pizzitola, Marina Giurescu, Roxanne Lorans, William Eversman, Richard Sharpe, Patricia Cronin, Donald Northfelt, Karen Anderson, Brenda Ernst, Bhavika Patel. Experience of contrast-enhanced mammography in patients with breast augmentation surgery [abstract]. In: Proceedings of the 2020 San Antonio Breast Cancer Virtual Symposium; 2020 Dec 8-11; San Antonio, TX. Philadelphia (PA): AACR; Cancer Res 2021;81(4 Suppl):Abstract nr PS3-23.
Concurrent Liver and Mesentery Primary Extraosseous Multiple Myeloma on 18F-FDG PET/CT
Abstract Extramedullary multiple myeloma (EMM) is a subset of multiple myeloma with a poor prognosis. We report a rare case with biopsy-proven concurrent liver and mesentery primary EMM at the time of initial staging after serologic diagnosis of multiple myeloma. 18F-FDG PET/CT is valuable in detection of EMM when the patient has no osseous lesions and a negative bone marrow biopsy.