Abstract Objective To assess the performance and cost implications of contrast-enhanced mammography-guided biopsy (CEM Bx). Methods This is a prospective study from May 5, 2021, to April 18, 2022, across 2 U.S. academic centers, evaluating technical success, patient/radiologist feedback, and operational factors of CEM Bx. Inclusion criteria included that patients be 40 years or older and recommended for biopsy with suspicious findings on contrast-enhanced mammography (CEM). Descriptive statistics are reported for clinical outcomes, length of procedure, and user and participant feedback. An estimate of cost was made by comparing general Medicare costs that are being billed for CEM Bx and post-clip mammogram ($475.48) to the Medicare costs of MRI-guided biopsy (MRI Bx) and post-clip placement mammogram ($845.94). Results Eighty-two participants enrolled. Twenty-two were excluded at the time of CEM Bx (22/82, 27%). Sixty participants were included (mean age 57 years, range 33 to 81 years) with 63 suspicious CEM lesions. The malignancy rate was 22% (14/63). A technical success rate of 100% was achieved. Average CEM Bx time was 29% to 33% the average reported MRI-guided breast biopsy times (CEM Bx = 11 minutes; MRI Bx = 33 to 38 minutes), indicating operational efficiencies. A positive opinion of CEM Bx was reported by 78% of radiologists, 93% of technologists, and 98% of patients. The estimated cost for each CEM Bx was ~ 45% lower than MRI Bx. Conclusion CEM Bx demonstrates high success rates and satisfaction scores. CEM Bx resulted in shorter procedure times, enhanced operational efficiency, and ~45% reduction in costs compared with MRI Bx. As advancements continue, we anticipate CEM Bx will offer a cost-efficient and timely option for breast biopsy.
Cystic Breast Disease: What to Do When It’s Not So Cystic
Abstract Cystic breast masses are a common entity encountered by breast radiologists. The imaging features of benign and malignant cystic masses may overlap, causing confusion and miscategorization with the potential to produce diagnostic delay and harm. This article provides a review of key differentiating imaging features that help guide appropriate mass characterization and treatment.
Biliary Disorders, Anomalies, and Malignancies in Children
Imaging Characteristics of and Multidisciplinary Management Considerations for Atypical Ductal Hyperplasia and Flat Epithelial Atypia: Review of Current Literature
Abstract Contrast-enhanced mammography (CEM) has emerged as an important new technology in breast imaging. It can demonstrate a number of imaging artifacts that have the potential to limit interpretation by either obscuring or potentially mimicking disease. Commonly encountered artifacts on CEM include patient motion artifacts (ripple and misregistration), pectoral highlighting artifact, breast implant artifact, halo artifact, corrugation artifact, cloudy fat artifact, contrast artifacts (retention and contamination), skin artifacts (skin line enhancement and skin overexposure), and skin lesions. Skin lesions may demonstrate a variety of imaging appearances and have both benign and malignant etiologies. It is important that the technologist, radiologist, and physicist be aware of potential artifacts and skin enhancement on CEM that may affect interpretation and understand their causes and potential solutions.
Bargain Hunting for Buffered Lidocaine: A Collaborative Discovery of Cost-saving Strategies That Can Improve Patient Care
Abstract Buffered lidocaine is a local anesthetic option during percutaneous needle-directed procedures in the breast. At our institution, sodium bicarbonate (the buffer) is dispensed in volumes that frequently lead to medical waste and shortages. In this study, we describe how moving the buffering of lidocaine from the procedure room to our clinical hospital pharmacy results in a reduction in costs and improves satisfaction across the breast radiology department. While cost savings are difficult to tease out in practices that opt for bundled payments, we were able to access pricing and supply data and coordinate with our pharmacy to change our practice. Making these changes saves our practice $26 000 a year and allows us to continue to offer buffered lidocaine even during sodium bicarbonate shortages. This manuscript describes how these changes came about and their economic impact.