Prospective Study of Supplemental Screening With Contrast-Enhanced Mammography in Women With Elevated Risk of Breast Cancer: Results of the Prevalence Round
PURPOSE Contrast-enhanced mammography (CEM) and magnetic resonance imaging (MRI) have shown similar diagnostic performance in detection of breast cancer. Limited CEM data are available for high-risk breast cancer screening. The purpose of the study was to prospectively investigate the efficacy of supplemental screening CEM in elevated risk patients. MATERIALS AND METHODS A prospective, single-institution, institutional review board–approved observational study was conducted in asymptomatic elevated risk women age 35 years or older who had a negative conventional two-dimensional digital breast tomosynthesis screening mammography (MG) and no additional supplemental screening within the prior 12 months. RESULTS Four hundred sixty women were enrolled from February 2019 to April 2021. The median age was 56.8 (range, 35.0-79.2) years; 408 of 460 (88.7%) were mammographically dense. Biopsy revealed benign changes in 22 women (22/37, 59%), high-risk lesions in four women (4/37, 11%), and breast cancer in 11 women (11/37, 30%). Fourteen cancers (10 invasive, tumor size range 4-15 mm, median 9 mm) were diagnosed in 11 women. The overall supplemental cancer detection rate was 23.9 per 1,000 patients, 95% CI (12.0 to 42.4). All cancers were grade 1 or 2, ER+ ERBB2–, and node negative. CEM imaging screening offered high specificity (0.875 [95% CI, 0.844 to 0.906]), high NPV (0.998 [95% CI, 0.993 to 1.000), moderate PPV1 (0.164 [95% CI, 0.076 to 0.253), moderate PPV3 (0.275 [95% CI, 0.137 to 0.413]), and high sensitivity (0.917 [95% CI, 0.760 to 1.000]). At least 1 year of imaging follow-up was available on all patients, and one interval cancer was detected on breast MRI 4 months after negative screening CEM. CONCLUSION A pilot trial demonstrates a supplemental cancer detection rate of 23.9 per 1,000 in women at an elevated risk for breast cancer. Larger, multi-institutional, multiyear CEM trials in patients at elevated risk are needed for validation.
Contrast-Enhanced Mammography for Newly Diagnosed Breast Cancer in Women With Breast Augmentation: Preliminary Findings
Abstract Background: Contrast-enhanced mammography (CEM) is an emerging breast imaging technique utilizing iodinated contrast to highlight areas of neovascularity. The role of CEM in patients with breast implants has not yet been characterized. We report our clinical experience of CEM in patients with breast augmentation surgery to better understand the potential diagnostic utility and limitations of CEM in the setting of breast implants. Materials and Methods: A HIPPA compliant, IRB exempt single-institution review of prospective CEM cases who had “breast implants” in their report between 01/2015 and 03/2020. Medical records were reviewed to supplement database information. Results: Forty-six patients were included with a mean age of 52 years (range 33-72). Clinical indications included: high risk research screen 3 (6%), diagnostic evaluation for abnormal imaging 24 (52%), further evaluation of newly diagnosed breast cancer 12 (26%) or assessment of neoadjuvant treatment response 7 (15%). Thirty patients had malignant lesions. Histology was invasive ductal carcinoma (90%), invasive lobular carcinoma (7%), and ductal carcinoma in situ (3%). CEM identified the index cancer and extent of disease in 28/30 (93%) of malignant cases. In two patients (7%), the malignant lesion was not included in the field-of-view due to its location. One of these lesions was a far medial mass within the breast which was detected by ultrasound alone. The other false negative CEM was a palpable axillary mass negative on both mammogram (MG) and MRI but seen by ultrasound. Twenty-three (50%) underwent additional breast MRI of which 20 had an already diagnosed cancer. the findings on CEM were concordant with MR imaging for the index lesion in 19/20 (95%) cases (kappa=0.86; p <0.001). Six additional lesions were found by CEM and confirmed by MRI. Of these lesions, 33% were found to be malignant and changed the surgical procedure. Four were only seen on CEM (no MRI comparison was available) and 75% were found to be malignant. One was only seen on MRI and was benign. One additional lesion was only seen as an asymmetry on MG without CEM or MRI correlate. This was benign on both the biopsy and surgical pathology. Conclusions: CEM appears to be a valuable breast imaging modality for diagnostic evaluations and surgical staging, including patients with breast implants. Due to technical artifacts and positioning limitations for posterior lesions, we recommend performing CEM with implant displaced views. Breast centers that use CEM, should be aware of field of view as a potential limitation when evaluating extent of disease in patients with breast augmentation. Citation Format: Molly Carnahan, Barbara Pockaj, Victor Pizzitola, Marina Giurescu, Roxanne Lorans, William Eversman, Richard Sharpe, Patricia Cronin, Donald Northfelt, Karen Anderson, Brenda Ernst, Bhavika Patel. Experience of contrast-enhanced mammography in patients with breast augmentation surgery [abstract]. In: Proceedings of the 2020 San Antonio Breast Cancer Virtual Symposium; 2020 Dec 8-11; San Antonio, TX. Philadelphia (PA): AACR; Cancer Res 2021;81(4 Suppl):Abstract nr PS3-23.
Abstract PS2-41: Supplemental contrast enhanced mammography screening of women with elevated risk of breast cancer
Abstract Objective and Rationale: To investigate the utility of screening Contrast Enhanced Mammography (CEM) imaging as a supplemental screening tool in women at elevated risk for breast cancer. Materials and Methods: This prospective, single institution, IRB approved observational study was conducted in asymptomatic women 35 years of age or older who were deemed at elevated risk of breast cancer, defined as IBIS v.8.0 lifetime risk of breast cancer score >15% or a prior personal history of breast cancer. Enrollment started in January 2019 and is on-going. An interim data analysis was performed. Women were invited to undergo supplemental CEM screening within 180 days of negative (BI-RADS 1 or 2) conventional 2D/3D screening mammography (MG). Patients with prior screening MBI, ultrasound or MR imaging within 12 months were excluded from study participation. Outcome measures were supplemental cancer detection rates, sensitivity, specificity, positive predictive value, and negative predictive value of CEM, along with their 95% confidence intervals, as well as the biologic profiles of MG-occult, CEM detected cancers. Results: A total of 351 women were enrolled in this prospective study over a 20-month period. To date, we have 1 year follow up on 106 cases with negative follow-up MG. Average age of the participants was 56 years ± 9.44 (standard deviation); 11 patients had screening 2D MG, 333 had combined 3-D and 2-D screening MG; 309 dense and 37 non-dense breasts based on ACR BI-RADS categories. CEM depicted 8 additional breast cancers (table 1), which were otherwise MG occult, for an overall supplemental cancer detection rate of 22.7 per 1000 patients, 95% CI (9.9, 44.3). 1 false negative cancer on CEM imaging which was further detected on MR imaging only. Biopsy revealed 16 benign changes (16/28=57%), 4 high-risk lesions (4/28=14%), and 8 breast cancers (8/28=29%) (table 2). CEM imaging screening offered high specificity (0.942, 95% CI (0.917, 0.967), high NPV 0.997, 95% CI (0.991, 1.000) and moderate PPV (0.286, 95% CI (0.118, 0.453) and sensitivity (0.889, 95% CI (0.684, 1.000)). Size of CEM detected cancers ranged from 7 to 57 mm. Conclusion: This pilot trial demonstrates a supplemental cancer detection rate of 22.7 per 1000 during prevalence round of CEM screening in women at an elevated risk for breast cancer. These initial results are comparable to results reported for high-risk surveillance MR imaging. Larger, multi-institutional high-risk CEM trials are needed for those patients who are not otherwise undergoing regular supplemental surveillance MR imaging. Citation Format: Bhavika K. Patel, Victor Pizzitola, Donald Northfelt, Karen Anderson, Marina Giurescu, Gina Mazza, Roxanne Lorans, William Eversman, Richard Sharpe, Juliana Kling, Denise Millstine, Ernst Brenda, Patricia Cronin, Heidi Apsey, Jennifer Palmieri, Barbara Pockaj, Michele Halyard. Supplemental contrast enhanced mammography screening of women with elevated risk of breast cancer [abstract]. In: Proceedings of the 2020 San Antonio Breast Cancer Virtual Symposium; 2020 Dec 8-11; San Antonio, TX. Philadelphia (PA): AACR; Cancer Res 2021;81(4 Suppl):Abstract nr PS2-41.
Multimodality Imaging Techniques for Performing Challenging Core Biopsies
Introduction: This study aims to describe robot assisted surgery of the inferior vena cava (IVC) by assessing techniques utilized, perioperative outcomes, complications, and long-term patency of the IVC. Methods: A retrospective review was performed on all robotic surgeries involving dissection and repair of the IVC at our institution. Patient characteristics, operative reports, and follow-up visits were analyzed. Preoperative and postoperative imaging was independently reviewed by a single radiologist to determine changes in IVC diameter. Complications were analyzed according to early (<30 days) vs late (>30 days). Results: Thirty-four patients underwent robot assisted surgery of the vena cava from 2008 to 2018. Twenty-six cases were performed for urologic malignancy, four were performed for IVC filter explantation, and four renal vein transpositions were performed for nutcracker syndrome. Twenty-four of the 26 patients with urologic malignancy underwent radical nephrectomy with IVC tumor thrombectomy. Three cases were converted to open. Median length of stay was two nights, and mean estimated blood loss (EBL) was 375 mL. There were five complications, ranging from Clavien-Dindo grade II–IIIa, four of which were early complications. No patients required return to the operating room, and there were no perioperative mortalities. IVC diameter was reduced by 41% on axial diameter, with no patients experiencing compromised venous return. Conclusion: Robot assisted surgery offers the advantage of minimally invasive surgery with the ability to apply open surgical principles. In our series, an experienced multidisciplinary team approach yielded low EBL, short length of stay, and low complication rates.
Initial Experience of Tomosynthesis-Guided Vacuum-Assisted Biopsies of Tomosynthesis-Detected (2D Mammography and Ultrasound Occult) Architectural Distortions
Abdominal paracentesis complicated by perforation of a penetrating arterial branch is an extremely rare complication. We report 2 patients who presented with abdominal wall pseudoaneurysms following abdominal paracentesis for the evaluation and treatment of their hepatic dysfunction. We subsequently review the treatment modalities and interventions performed in each case.
Ureteroarterial Fistula Following Laser Endopyelotomy