Back to Authors

Rajiah, Prabhakar

https://orcid.org/0000-0001-7538-385X

Mayo Clinic

Mayo Clinic

Citations 62

“Uncomplicated” Type B Aortic Dissection: It’s Complicated
Rajiah, Prabhakar , Rajiah, Prabhakar

Radiology: Cardiothoracic Imaging | December 22, 2022 | Volume: 4 | Issue: 6 | Pages: No page available

10.1148/ryct.220278 Get It

Cardiac Nuclear Medicine: Techniques, Applications, and Imaging Findings
Panda, Ananya , Homb, Andrew, Krumm, Patrick , Huang, Steve S. , Bolen, Michael A. , Rajiah, Prabhakar , Homb, Andrew C, Nikolaou, Konstantin , Huang, Steve S , Jaber, Wael, Bolen, Michael A , Rajiah, Prabhakar , Jaber, Wael A.

RadioGraphics | December 9, 2022 | Volume: 43 | Issue: 1 | Pages: No page available

10.1148/rg.220027 Get It

Myocarditis Mimicking Stress-Induced (Takotsubo) Cardiomyopathy
Canan, Arzu , Woerkom, Ryan C. Van , Rajiah, Prabhakar , Rajiah, Prabhakar Shantha, Rajiah, Prabhakar

Texas Heart Institute Journal | December 9, 2022 | Volume: 49 | Issue: 6 | Pages: No page available

10.14503/thij-20-7430 Get It

High‐pitch, high temporal resolution, multi‐energy cardiac imaging on a dual‐source photon‐counting‐detector CT
Ahmed, Zaki, Campeau, David, Gong, Hao , Rajiah, Prabhakar , McCollough, Cynthia, Rajiah, Prabhakar , Rajendran, Kishore , McCollough, Cynthia H. , Leng, Shuai

Medical Physics | November 25, 2022 | Volume: 50 | Issue: 3 | Pages: 1428-1435

10.1002/mp.16124 Get It

AbstractObjectiveTo measure the accuracy of material decomposition using a dual‐source photon‐counting‐detector (DS‐PCD) CT operated in the high‐pitch helical scanning mode and compare the results against dual‐source energy‐integrating‐detector (DS‐EID) CT, which requires use of a low‐pitch value in dual‐energy mode.MethodsA DS‐PCD CT and a DS‐EID CT were used to scan a cardiac motion phantom consisting of a 3‐mm diameter iodine cylinder. Iodine maps were reconstructed using DS‐PCD in high‐pitch mode and DS‐EID in low‐pitch mode. Image‐based circularity, diameter, and iodine concentration of the iodine cylinder were calculated and compared between the two scanners. With institutional review board approval, in vivo exams were performed with the DS‐PCD CT in high‐pitch mode. Images were qualitatively compared against patients with similar heart rates that were scanned with DS‐EID CT in low‐pitch dual‐energy mode.ResultsOn iodine maps, the mean circularity was 0.97 ± 0.02 with DS‐PCD in high‐pitch mode and 0.95 ± 0.06 with DS‐EID in low‐pitch mode. The mean diameter was 2.9 ± 0.2 mm with DS‐PCD and 3.1 ± 0.2 mm with DS‐EID, both of which are close to the 3 mm ground truth. For DS‐PCD, the mean iodine concentration was 9.6 ± 0.8 mg/ml and this was consistent with the 9.4 ± 0.6 mg/ml value obtained with the cardiac motion disabled. For DS‐EID, the concentration was 12.7 ± 1.2 mg/ml with motion enabled and 11.7 ± 0.5 mg/ml disabled. The background noise in the iodine maps was 15.1 HU with DS‐PCD and 14.4 HU with DS‐EID, whereas the volume CT dose index (CTDIvol) was 3 mGy with DS‐PCD and 11 mGy with DS‐EID. On comparison of six patients (three on PCD, three on EID) with similar heart rates, DS‐PCD provided iodine maps with well‐defined coronaries even at a high heart rate of 86 beats per minute. Meanwhile, there were substantial motion artifacts in iodine maps obtained with DS‐EID for patients with similar heart rates.ConclusionIn a cardiac motion phantom, DS‐PCD CT can perform accurate material decomposition in high‐pitch mode, providing iodine maps with excellent geometric accuracy and robustness to motion at approximately 38% of the dose for similar noise as DS‐EID CT.
Dynamic CT Angiography in Vascular Imaging: Principles and Applications
Rajiah, Prabhakar , Weber, Nikkole M. , Loewen, Jennifer M. , Kasten, Holly J., Williamson, Eric , Moore, Alastair , Leng, Shuai , Rajiah, Prabhakar , Weber, Nikkole , Loewen, Jennifer , Kasten, Holly, Leng, Shuai

RadioGraphics | September 30, 2022 | Volume: 42 | Issue: 7 | Pages: E224-E225

10.1148/rg.210177 Get It

Articular Findings on Chest Computed Tomography: An Algorithmic Approach for Radiologists
Mansoori, Bahar , Kosaraju, Vijaya, Yoon, James, Zadeh, Firoozeh Shomal , Vo, Kiet V. , Shafiei, Mehrzad , Rajiah, Prabhakar , Rajiah, Prabhakar , Chalian, Hamid , Chalian, Majid

Journal of Computer Assisted Tomography | September 2, 2022 | Volume: 46 | Issue: 6 | Pages: 914-922

10.1097/rct.0000000000001364 Get It

Abstract Chest computed tomography (CT) is one of the most frequently performed imaging studies. Incidental osseous and articular findings are commonly encountered in chest CTs in daily practice. The spectrum of findings is broad, varying from benign to malignant, and interpretation of these incidental musculoskeletal findings could be challenging for radiologists. In this review, we provide a systematic algorithmic approach for the diagnosis of common articular findings seen on chest CT with recommendations for appropriate follow-up evaluation.
Photon-Counting Detector CT: Key Points Radiologists Should Know
Esquivel, Andrea , Ferrero, Andrea , Mileto, Achille , Baffour, Francis , Horst, Kelly K. , Rajiah, Prabhakar , Inoue, Akitoshi , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G. , Horst, Kelly , Rajiah, Prabhakar , McCollough, Cynthia H , Fletcher, Joel G , Leng, Shuai , Baffour, Francis I , Inoue, Akitoshi

Korean Journal of Radiology | August 10, 2022 | Volume: 23 | Issue: 9 | Pages: 854

10.3348/kjr.2022.0377 Get It

Optimizing low contrast volume thoracic CT angiography: From the basics to the advanced
Kaproth-Joslin, Katherine , Hobbs, Susan K. , Chaturvedi, Apeksha , Chaturvedi, Abhishek , Rajiah, Prabhakar

Journal of Clinical Imaging Science | July 29, 2022 | Volume: 12 | Issue: No issue available | Pages: 41

10.25259/jcis_51_2022 Get It

Contrast-enhanced CT angiography (CTA) is a widely used, noninvasive imaging technique for evaluating cardiovascular structures. Contrast-induced nephrotoxicity is a concern in renal disease; however, the true nephrotoxic potential of iodinated contrast media (CM) is unknown. If a renal impaired patient requires CTA, it is important to protect the kidneys from further harm by reducing total iodinated CM volume while still obtaining diagnostic quality imaging. These same reduced volume CM techniques can also be applied to nonrenal impaired patients in times of CM shortage. This educational review discusses several modifications to CTA that can be adapted to both conventional 64-slice and the newer generation CT scanners which enable subsecond acquisition with a reduced CM volume technique. Such modifications include hardware and software adjustments and changes to both the volume and flow rate of administered CM, with the goal to reduce the dose of CM without compromising diagnostic yield.
Pre- and Postprocedure Imaging of Transcatheter Pulmonary Valve Implantation
Canan, Arzu , Ocazionez-Trujillo, Daniel , Vargas, Daniel , Foley, Thomas A. , Rajiah, Prabhakar , Cabalka, Allison K. , Rajiah, Prabhakar

RadioGraphics | June 10, 2022 | Volume: 42 | Issue: 4 | Pages: 991-1011

10.1148/rg.210160 Get It

Novel imaging biomarkers predict outcomes in stage III unresectable non-small cell lung cancer treated with chemoradiation and durvalumab
Khorrami, Mohammadhadi , Gad, Mohamed M. , Gupta, Amit , Patil, Pradnya D. , Viswanathan, Vidya Sankar , Rajiah, Prabhakar , Nock, Charles, Gilkey, Michael , Pennell, Nathan A , Madabhushi, Anant , Rajiah, Prabhakar , Madabhushi, Anant , Jazieh, Khalid , Saad, Anas M. , Fu, Pingfu , Madabhushi, Anant

Journal for ImmunoTherapy of Cancer | March 7, 2022 | Volume: 10 | Issue: 3 | Pages: e003778

10.1136/jitc-2021-003778 Get It

Background The landmark study of durvalumab as consolidation therapy in NSCLC patients (PACIFIC trial) demonstrated significantly longer progression-free survival (PFS) in patients with locally advanced, unresectable non-small cell lung cancer (NSCLC) treated with durvalumab (immunotherapy, IO) therapy after chemoradiotherapy (CRT). In clinical practice in the USA, durvalumab continues to be used in patients across all levels of programmed cell death ligand-1 (PD-L1) expression. While immune therapies have shown promise in several cancers, some patients either do not respond to the therapy or have cancer recurrence after an initial response. It is not clear so far who will benefit of this therapy or what the mechanisms behind treatment failure are. Methods A total of 133 patients with unresectable stage III NSCLC who underwent durvalumab after CRT or CRT alone were included. Patients treated with durvalumab IO after CRT were randomly split into training (D1=59) and test (D2=59) sets and the remaining 15 patients treated with CRT alone were grouped in D3. Radiomic textural patterns from within and around the target nodules were extracted. A radiomic risk score (RRS) was built and was used to predict PFS and overall survival (OS). Patients were divided into high-risk and low-risk groups based on median RRS. Results RRS was found to be significantly associated with PFS in D1 (HR=2.67, 95% CI 1.85 to 4.13, p<0.05, C-index=0.78) and D2 (HR=2.56, 95% CI 1.63 to 4, p<0.05, C-index=0.73). Similarly, RRS was associated with OS in D1 (HR=1.89, 95% CI 1.3 to 2.75, p<0.05, C-index=0.67) and D2 (HR=2.14, 95% CI 1.28 to 3.6, p<0.05, C-index=0.69), respectively. RRS was found to be significantly associated with PFS in high PD-L1 (HR=3.01, 95% CI 1.41 to 6.45, p=0.0044) and low PD-L1 (HR=2.74, 95% CI 1.8 to 4.14, p=1.77e-06) groups. Moreover, RRS was not significantly associated with OS in the high PD-L1 group (HR=2.08, 95% CI 0.98 to 4.4, p=0.054) but was significantly associated with OS in the low PD-L1 group (HR=1.61, 95% CI 1.14 to 2.28, p=0.0062). In addition, RRS was significantly associated with PFS (HR=2.77, 95% CI 1.17 to 6.52, p=0.019, C-index=0.77) and OS (HR=2.62, 95% CI 1.25 to 5.51, p=0.01, C-index=0.77) in D3, respectively. Conclusions Tumor radiomics of pretreatment CT images from patients with stage III unresectable NSCLC were prognostic of PFS and OS to CRT followed by durvalumab IO and CRT alone.