Back to Authors

Homb, Andrew C

Mayo Clinic

From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 559905 (A.P., A.C.H., P.S.R.); Department of Radiology, All India Institute of Medical Sciences, Jodhpur, India (A.P); Department of Radiology, University of Tubingen, Tubingen, Ge

Citations 4

Pathology-Based Validation of Quantitative SPECT/CT in Patients With Suspected Transthyretin Amyloid Cardiomyopathy
Tersalvi, Gregorio , Bois, Melanie C. , Scott, Christopher G. , Carey, Patricia , Garmany, Armin , Davies, Daniel R. , HOFFMAN, Andrew C., Zhang, Jun , Hruska, Carrie B. , Jouni, Hayan, Rodriguez-Porcel, Martin G., Askew, J. Wells , Bois, John P. , Young, Kathleen A. , Anavekar, Nandan S., CHANG, IAN C., Grogan, Martha , Maleszewski, Joseph J. , Homb, Andrew, Redfield, Margaret M. , Dispenzieri, Angela , Maleszewski, Joseph J , Homb, Andrew C, Redfield, Margaret M , Chareonthaitawee, Panithaya , Johnson, Geoffrey B , AbouEzzeddine, Omar F , Hruska, Carrie B , Scott, Christopher , Tersalvi, Gregorio , Carey, Patricia , Rodriguez‐Porcel, Martin , Anavekar, Nandan S., Dispenzieri, Angela , Chareonthaitawee, Panithaya , Johnson, Geoffrey B. , AbouEzzeddine, Omar F.

Circulation: Cardiovascular Imaging | July 23, 2026 | Volume: 19 | Issue: 8 | Pages: No page available

10.1161/circimaging.126.019832 Get It

BACKGROUND: Technetium-based cardiac amyloid radionuclide imaging enables noninvasive diagnosis of transthyretin amyloid cardiomyopathy (ATTR-CM), but conventional planar and visual semiquantitative approaches have important limitations. We developed the quantitative 3-dimensional Mayo 3D Score, defined as the ratio of mean left ventricular myocardial radiotracer uptake to right atrial blood-pool uptake using computed tomography (CT)-fused single-photon emission CT (SPECT) volumes of interest, and sought to validate its diagnostic performance against myocardial pathology. METHODS: Consecutive patients who underwent 99m Tc-pyrophosphate SPECT/CT at Mayo Clinic for suspected ATTR-CM between June 2017 and January 2025 with archived myocardial tissue were included. Baseline characteristics, including demographics, echocardiogram, biomarkers, visual semiquantitative, and Mayo 3D Score metrics, were collected. Myocardial specimens underwent histopathologic confirmation of amyloid, with amyloid subtype determination and further semiquantitative grading of amyloid burden and deposition patterns. RESULTS: Among 230 patients (median age, 72 years; 78% male), 107 (47%) had ATTR-CM, of whom 9 had hereditary ATTR-CM. The Mayo 3D Score showed excellent discrimination against pathology (area under the receiver operating characteristic curve, 0.92 [0.88–0.96]), exceeding planar Perugini (0.87 [0.83–0.92]; P =0.006), and heart-to-contralateral lung ratio (0.86 [0.81–0.91]; P =0.004) and comparable to SPECT Perugini (0.90 [0.86–0.94]; P =0.12). A cutoff ≥1.0 yielded 86.0% sensitivity, 92.7% specificity, 91.1% positive predictive value, and 88.4% negative predictive value. Among ATTR-positive cases, the Mayo 3D Score correlated strongly with semiquantitative amyloid burden (Spearman ρ=0.69), was higher in pericellular than nodular deposition patterns ( P <0.001), and was not associated with vascular involvement ( P =0.42). CONCLUSIONS: In patients with suspected ATTR-CM undergoing 99m Tc-pyrophosphate SPECT/CT, the Mayo 3D Score demonstrated superior diagnostic performance compared with planar metrics and comparable to SPECT Perugini, while correlating with myocardial ATTR burden and deposition patterns on pathology. These findings support its integration as a quantitative adjunct within clinical diagnostic ATTR-CM workflows.
Diagnostic Performance and Interpreter Experience of 1-Hour Versus 3-Hour 99m Tc-HMDP Cardiac Amyloid Radionuclide Imaging: A Prospective, Blinded Comparison
Tersalvi, Gregorio , Carey, Patricia , Garmany, Armin , Scott, Christopher G. , Maldonado, Francisco J., Krüger, Leandi , Hruska, Carrie B. , Johnson, Geoffrey B. , Jouni, Hayan, Rodriguez‐Porcel, Martin , Askew, J. Wells , Bois, John P. , Young, Kathleen A. , Anavekar, Nandan S., Grogan, Martha , Homb, Andrew, Zhang, Jun , Kruger, Livia F , Hruska, Carrie B , Johnson, Geoffrey B , Rodriguez-Porcel, Martin G., Askew, J Wells , Young, Kathleen , Grogan, Martha , Dispenzieri, Angela , Chareonthaitawee, Panithaya , Homb, Andrew C, AbouEzzeddine, Omar F , Scott, Christopher , Tersalvi, Gregorio , Carey, Patricia , Zhang, Jun , Maldonado, Francisco J., Dispenzieri, Angela , Chareonthaitawee, Panithaya , AbouEzzeddine, Omar F.

Circulation: Cardiovascular Imaging | December 8, 2025 | Volume: 19 | Issue: 1 | Pages: No page available

10.1161/circimaging.125.018745 Get It

BACKGROUND: Guidelines recommend 3-hour cardiac amyloid radionuclide imaging (CARI) for transthyretin amyloid cardiomyopathy. Citing rapid blood clearance of 99m Tc-hydroxymethylene-diphosphonate (HMDP) and efficient laboratory throughput, 1-hour imaging is increasingly practiced despite limited supporting evidence. We sought to compare diagnostic performance and interpreter experience of 1-hour versus 3-hour HMDP-CARI. METHODS: Consecutive patients with suspected transthyretin amyloid cardiomyopathy (n=114) underwent both 1-hour and 3-hour HMDP single photon emission computed tomography (CT)/CT. Two cardiologist-radiologist reader teams, blinded to imaging timepoint (1 versus 3 hours), assessed overall interpretation, single photon emission CT–based Perugini grade, interpretation difficulty, interpreter confidence, and need for CT-fused images for anatomic localization. Discordant, equivocal, and difficult cases were arbitrated by a third tie-breaking team. The myocardial-to-blood-pool radiotracer uptake ratio (3-dimensional Score) was measured as a surrogate of contrast resolution. RESULTS: Interinterpreter agreement was high at both time points (κ≥0.81), with more cases requiring arbitration at 3 hours versus 1 hour (22% versus 13%; P =0.049). Overall interpretation and Perugini grades were concordant between time points in 111/114 (97%) and 106/114 (93%) patients, respectively. Three patients (3%) were negative at 1 hour but equivocal at 3 hours, all of which were clinically ruled out for transthyretin amyloid cardiomyopathy. Interpreter confidence was comparable at both timepoints (97% versus 95%; P =0.317). Compared with 3-hour imaging, contrast resolution was inferior (lower 3-dimensional score, P <0.001) and CT fusion was more frequently needed (57% versus 31%, P <0.001) at 1-hour imaging. CONCLUSIONS: In a prospective, blinded comparison of 1-hour versus 3-hour HMDP-CARI, diagnostic performance and interpreter experience were similar, with readers requesting CT fusion more frequently at 1 hour to optimize myocardial-to-blood pool discrimination.
Bayesian penalized likelihood PET reconstruction impact on quantitative metrics in diffuse large B-cell lymphoma
Young, Jason R. , Mugu, Vamshi , Johnson, Geoffrey B. , Ehman, Eric C. , Packard, Annie T. , Homb, Andrew, Nathan, Mark A., Thanarajasingam, Gita , Kemp, Bradley J. , Mugu, Vamshi K, Homb, Andrew C, Johnson, Geoffrey B , Young, Jason R

Medicine | February 10, 2023 | Volume: 102 | Issue: 6 | Pages: e32665

10.1097/md.0000000000032665 Get It

Evaluate the quantitative, subjective (Deauville score [DS]) and reader agreement differences between standard ordered subset expectation maximization (OSEM) and Bayesian penalized likelihood (BPL) positron emission tomography (PET) reconstruction methods. A retrospective review of 104 F-18 fluorodeoxyglucose PET/computed tomography (CT) exams among 52 patients with diffuse large B-cell lymphoma. An unblinded radiologist moderator reviewed both BPL and OSEM PET/CT exams. Four blinded radiologists then reviewed the annotated cases to provide a visual DS for each annotated lesion. Significant (P < .001) differences in BPL and OSEM PET methods were identified with greater standard uptake value (SUV) maximum and SUV mean for BPL. The DS was altered in 25% of cases when BPL and OSEM were reviewed by the same radiologist. Interobserver DS agreement was higher for OSEM (>1 cm lesion = 0.89 and ≤1 cm lesion = 0.84) compared to BPL (>1 cm lesion = 0.85 and ≤1 cm lesion = 0.81). Among the 4 readers, average intraobserver visual DS agreement between OSEM and BPL was 0.67 for lesions >1cm and 0.4 for lesions ≤1 cm. F-18 Fluorodeoxyglucose PET/CT of diffuse large B-cell lymphoma reconstructed with BPL has higher SUV values, altered DSs and reader agreement when compared to OSEM. This report finds volumetric PET measurements such as metabolic tumor volume to be similar between BPL and OSEM PET reconstructions. Efforts such as adoption of European Association Research Ltd accreditation should be made to harmonize PET data with an aim at balancing the need for harmonization and sensitivity for lesion detection.
Cardiac Nuclear Medicine: Techniques, Applications, and Imaging Findings
Panda, Ananya , Homb, Andrew, Krumm, Patrick , Huang, Steve S. , Bolen, Michael A. , Rajiah, Prabhakar , Homb, Andrew C, Nikolaou, Konstantin , Huang, Steve S , Jaber, Wael, Bolen, Michael A , Rajiah, Prabhakar , Jaber, Wael A.

RadioGraphics | December 9, 2022 | Volume: 43 | Issue: 1 | Pages: No page available

10.1148/rg.220027 Get It