Back to Authors

Kadirvel, Ramanathan

https://orcid.org/0000-0002-6786-9953

Mayo Clinic

Mayo Clinic

Citations 185

Optimizing the hemodynamics of hand injections in neuroangiography
Bayraktar, Esref Alperen , Bilgin, Cem , Ueki, Yasuhito , Kadirvel, Ramanathan , Brinjikji, Waleed , Cloft, Harry J. , Kallmes, David F. , Bilgin, Cem , Kadirvel, Ram , Kallmes, David F , Bayraktar, Esref Alperen , Li, Jiahui , Cortese, Jonathan

Interventional Neuroradiology | September 23, 2024 | Volume: 30 | Issue: 6 | Pages: 833-838

10.1177/15910199241285944 Get It

Purpose Optimizing the preparation of a 10 ml syringe for manual injection of contrast media can help operators obtain easier and faster injections. This study aims to compare the flow rates of different contrast media injection methods. Methods Different contrast media solutions were compared: 100% contrast (10 ml contrast), mixed contrast solution (8:2 contrast/saline), and layered contrast below saline (“Parfait”) in different volumes. Contrast media were injected at room temperature (20°C) and after heating (37°C). Four operators injected 10 ml syringes filled with different mediums through 5-French angiographic catheters. The average flow rate was used to compare different contrast injection mediums. The Kruskal-Wallis test with post-hoc pairwise comparisons using Bonferroni correction or Mann-Whitney U-tests were employed depending on the type of comparison. Results Compared to the 100% contrast solution, every Parfait media and mixed contrast solution demonstrated significantly higher flow rates (p < 0.001). The 5 ml saline Parfait had the highest flow rate among the Parfait solutions. The 5 ml saline Parfait and the mixed solution had comparable flow rates (p = 0.237). Higher flow rates were observed upon heating both 100% contrast (p < 0.001) and mixed contrast solutions (p < 0.001) in comparison to their flow rates at room temperature. Conclusion This study demonstrates the capability of the Parfait and mixed contrast injections to achieve higher flow rates than the 100% contrast solutions. Heating the contrast media to 37°C also proves to be a viable strategy for further enhancing the flow rates for 100% and mixed contrast solutions.
Efficacy and safety of flow diverters in retreatment of recurrent intracranial aneurysms—A systematic review and meta-analysis
Zarrintan, Armin , Ghozy, Sherief , Maroufi, Seyed Farzad , Reda, Abdullah, Brinjikji, Waleed , Kadirvel, Ramanathan , Kallmes, David F. , Gajjar, Aryan , Ghozy, Sherief , Zarrintan, Armin

Interventional Neuroradiology | September 14, 2024 | Volume: 32 | Issue: 4 | Pages: 1729-1740

10.1177/15910199241282713 Get It

Background and purpose Treatment of recurrent intracranial aneurysms after their initial therapy has been a significant challenge in the field of neurointervention. Recently flow diverters stents are widely used for treating intracranial aneurysms. In this systematic review and meta-analysis, we assessed the safety and efficacy of flow diverter in treating recurrent or recanalized intracranial aneurysms. Methods This meta-analysis is reported following the PRISMA 2020 guidelines. We conducted a systematic review of literature in the PubMed, Embase, Web of Sciences, and Scopus databases. Pooled prevalence and the corresponding 95% are calculated from extracted data using a random-effect model. Results The systematic literature search included 21 studies involving 411 patients, with 135 (32.8%) being male and 276 (67.2%) being females with a total number of 447 aneurysms. The overall rate of adequate occlusion was 90.67% (95% CI: 84.23%–94.65%), and the rates were comparable between the surgery (93.48%), coiling (91.78%), and stenting (85.77%) groups. The overall pooled rate of complete occlusion was 81.80 (95% CI: 71.14%–89.13%). On doing a subgroup analysis, the complete occlusion rates were 89.68%, 84.39%, and 73.47% for the surgery, coiling, and stenting groups, respectively. The overall mortality rate and achieving modified Rankin scale score of 0-2 was 1.28% (95% CI: 0.45%–3.64%) and (95% CI: 89.92%–97.84%), respectively. No significant heterogeneity is noted in the included studies. Conclusion Flow diverter stents are an effective and safe method for retreating recurrent or residual intracranial aneurysms with a high rate of complete and adequate occlusion. The rate of mortality, intracerebral hemorrhage, and overall and procedural complications following using flow diverters for intracranial aneurysms is low.
Neck apposition is a key factor for aneurysm occlusion after Woven EndoBridge device embolization
Cortese, Jonathan , Juhász, J , Rodriguez‐Erazú, Fernanda , Ghozy, Sherief , Bayraktar, Esref Alperen , Zarrintan, Armin , Ueki, Yasuhito , Caroff, Jildaz , Kallmes, David F. , Kadirvel, Ramanathan , Zarrintan, Armin , Caroff, Jildaz , Spelle, Laurent , Kadirvel, Ram , Ghozy, Sherief , Cortese, Jonathan , Bayraktar, Esref Alperen , Mihalea, Cristian , Spelle, Laurent

Journal of NeuroInterventional Surgery | August 8, 2024 | Volume: 17 | Issue: 10 | Pages: 1083-1088

10.1136/jnis-2024-022155 Get It

Background Sealing of the aneurysm neck with a Woven EndoBridge (WEB) device is recommended for disrupting the blood flow inside the aneurysm. This study investigates the relationship between WEB neck apposition and aneurysm occlusion rates. Methods Aneurysms treated with a WEB from March 2017 to May 2022 at a single center were included. WEB neck apposition (poor/good) and WEB protrusion (yes/no) were evaluated on post-detachment high resolution cone beam CT images. Angiographic occlusion was assessed with the Bicêtre Occlusion Scale score (BOSS). Univariate and multivariable analysis tested the association between neck apposition and occlusion rates. Results The study included 159 aneurysms in 141 patients (mean age 55.8±11.2 years; 64.2% women). Good neck apposition and protrusion were noted in 123 (77.4%) and 30 (18.9%) cases, respectively. Inter-rater agreements were good for neck apposition (κ=0.75) and protrusion (κ=0.78). Complete and adequate occlusion was achieved in 104 (65%) and 130 (82%) cases, respectively (median follow-up 18 months). Good neck apposition was a strong independent predictor for both adequate (adjusted OR (aOR)=5.9, 95% CI 2.4 to 14.9; P<0.001) and complete occlusion (aOR=7.1, 95% CI 3.0 to 18.1; P<0.001). Protrusion was more frequent in the adequate occlusion group versus the aneurysm recurrence group without reaching statistical significance (P=0.06), but was associated with more thromboembolic complications (9/30 (30%) vs 12/129 (9%); P<0.01). WEB shape modification was significantly greater in poor apposition cases (P=0.03). Conclusions Achieving good neck apposition of the WEB strongly predicts aneurysm occlusion during follow-up. WEB protrusion should be minimized due to the increase in thromboembolic risk with limited impact on aneurysm occlusion.
The Utilization of Systematic Reviews and Meta-Analyses in Stroke Guidelines
Ghozy, Sherief , Amoukhteh, Melika , Kadirvel, Ramanathan , Brinjikji, Waleed , Carpenter, Christopher R. , Kallmes, David F. , Amoukhteh, Melika , Carpenter, Christopher R , Ghozy, Sherief , Kobeissi, Hassan , Rabinstein, Alejandro A.

Brain Sciences | July 23, 2024 | Volume: 14 | Issue: 7 | Pages: 728

10.3390/brainsci14070728 Get It

Background: Stroke guideline statements are important references for clinicians due to the rapidly evolving nature of treatments. Guideline statements should be informed by up-to-date systematic reviews (SRs) and meta-analyses (MAs) because they provide the highest level of evidence. To investigate the utilization of SRs/MAs in stroke management guidelines, we conducted a literature review of guidelines and extracted relevant information regarding SRs/MAs. Methods: A literature review was conducted in PubMed with supplementation using the Trip medical database with the term “stroke” as the target population, followed by using the filter “guidelines”. We extracted the number of included SRs/MAs, the years of publication, the country of origin, and other characteristics of interest. Descriptive statistics were generated using the R software version 4.2.1. Results: We included 27 guideline statements. The median number of overall SRs or MAs within the guidelines was 4.0 (interquartile range [IQR] = 2–9). For MAs only, the median number included in the guidelines was 3.0 (IQR = 2.0–5.5). Canadian guidelines had the oldest citations, with a median gap of 12.0 (IQR = 5.2–18.0) years for the oldest citation, followed by European (median = 12; IQR = 9.5–13.5) and US (median = 10.0; IQR = 5.2–16) guidelines. Conclusions: Stroke guideline writing groups and issuing bodies should devote greater effort to the inclusion of up-to-date SRs/MAs in their guideline statements so that clinicians can reference recent data with the highest level of evidence.
E-164 Safety profile of surgical embolectomy in acute ischemic stroke patients: a systematic review and meta-analysis
Pakkam, Madona , Bilgin, Cem , Kadirvel, R, Kallmes, D, Orscelik, Atakan , Musmar, Basel , Senol, Y, Ghozy, Sherief , Kadirvel, Ramanathan , Kallmes, David F.

SNIS 21st annual meeting electronic poster abstracts | July 22, 2024 | Volume: No volume available | Issue: No issue available | Pages: A183.2-A184

10.1136/jnis-2024-snis.269 Get It

Pipeline versus non-pipeline flow diverter treatment for M1 aneurysms: A systematic review and meta-analysis
Şenol, Yiğit Can , Orscelik, Atakan , Bilgin, Cem , Kallmes, David F. , Kadirvel, Ramanathan , Arul, Santhosh , Orscelik, Atakan , Senol, Yigit Can , Kobeissi, Hassan , Ghozy, Sherief

The Neuroradiology Journal | July 21, 2024 | Volume: 38 | Issue: 2 | Pages: 133-141

10.1177/19714009241260805 Get It

Background The flow diversion treatment of aneurysms located distal to the Circle of Willis has recently increased in frequency. We conducted a systematic review and meta-analysis of the clinical and radiological outcomes of flow diverter (FD) embolization in treating M1 aneurysms. Methods PubMed, Web of Science, Ovid Medline, Ovid Embase, and Scopus were searched up to May 2024 using the Nested Knowledge platform. We included studies assessing the long-term clinical and radiological outcomes for M1 aneurysms. Results of FDs classified as Pipeline Embolization Devices (PED) versus other types of FDs. Angiographic occlusion rates, ischemic and hemorrhagic complications, and favorable clinic outcomes were included. All data were analyzed using R software version 4.2.2. Results Thirteen studies with 112 total patients (58 patients for PED and 54 patients for other FD devices) were included in our meta-analysis. The overall adequate (complete + near-complete) occlusion rates were 85.1%. The complete occlusion rate was higher with PED than with other FD devices (72.9% PED and 41.6% for non-PED FDs, respectively, p -value <.01). The ischemic complications were 9.9% and 9.0% for the PED and non-PED groups, respectively ( p -value = .89). The overall modified Rankin Scale 0–2 was 100% for the non-PED and 97.1% for the PED group ( p -value = .51). In-stent stenosis rate was 7.5% for PED devices compared to 2.6% in the non-PED group ( p -value = .35). Conclusions This relatively small meta-analysis showed high rates of adequate and complete occlusion in FD treatment of M1 segment aneurysms, with favorable safety profiles. PEDs were associated with higher rates of complete aneurysm occlusion compared to other types of FDs.
In vitro evaluation of flow diverter performance using a human fibrinogen–based flow model
Bilgin, Cem , Kallmes, David F. , Kadirvel, Ramanathan , Bayraktar, Esref Alperen , Oliver, Alexander A , Li, Jiahui , Cebral, Juan R.

Journal of Neurosurgery | July 12, 2024 | Volume: 142 | Issue: 1 | Pages: 154-161

10.3171/2024.4.jns232567 Get It

OBJECTIVE Fibrin deposition represents a key step in aneurysm occlusion, promoting endothelization of implants and connective tissue organization as part of the aneurysm-healing mechanism. In this study, the authors introduce a novel in vitro testing platform for flow diverters based on human fibrinogen. METHODS A flow diverter was deployed in 4 different glass models. The glass models had the same internal parent artery (4 mm) and aneurysm (8 mm) diameters with varying parent artery angulations (paraophthalmic, sidewall, bifurcation, and slightly curved models). The neck size and area were 4 mm and 25 mm 2 , respectively. Human fibrinogen (330 mg/dl) was circulated within the glass models at varying flow rates (0, 3, 4, and 5 ml/sec) with or without heparin, calcium chloride, and thrombin for as long as 6 hours or until complete fibrin coverage of the flow diverter’s neck was achieved. Aneurysm neck coverage was defined as macroscopic fibrin deposition occluding the flow diverters’ pores. Flow characteristics after flow diverter deployment were assessed with computational fluid dynamics analysis. The effects of flow rates, heparin, calcium chloride, and thrombin on fibrin deposition rates were tested using 1-way ANOVA and the Tukey test. RESULTS A total of 84 replicates were performed. Human fibrin did not accumulate on the flow diverter stents under static conditions. The fibrin deposition rate on the aneurysm neck was significantly greater with the 5 ml/sec flow rate as compared to 3 ml/sec for all models. The paraophthalmic model had the highest inflow velocity of 48.7 cm/sec. The bifurcation model had the highest maximum shear stress (SS) and maximum normalized shear stress values at the device cells at 843.3 dyne/cm 2 and 35.1 SS/SS inflow , respectively. The fibrin deposition rates of the paraophthalmic and bifurcation models were significantly higher than those of sidewall and slightly curved models for all additive or flow rate comparisons (p = 0.001 for all comparisons). The incorporation of thrombin significantly increased the fibrin deposition rates across all models (p = 0.001 for all models). CONCLUSIONS Rates of fibrin deposition varied widely across different configurations and additive conditions in this novel in vitro model system. Fibrin accumulation started at the aneurysm inflow zone where flow velocity and shear stress were the highest. The primary factors influencing fibrin deposition included flow velocities, shear stress, and the addition of thrombin at a physiological concentration. Further research is needed to test the clinical utility of fibrinogen-based models for patient-specific aneurysms.
Creating elastase aneurysms in rabbits: a video primer
Cortese, Jonathan , Bayraktar, Esref Alperen , Oliver, Alexander A , Bilgin, Cem , Ding, Yong-Hong, Ueki, Yasuhito , Lortscher, Sarah, Brinjikji, Waleed , Kadirvel, Ramanathan , Kallmes, David F. , Cortese, Jonathan , Bayraktar, Esref Alperen , Oliver, Alexander A , Ding, Yonghong

Journal of NeuroInterventional Surgery | June 11, 2024 | Volume: 17 | Issue: 10 | Pages: 1133-1133

10.1136/jnis-2024-021912 Get It

The New Zealand rabbit elastase-induced arterial aneurysm of the right common carotid artery remains a widely used model for assessing the effectiveness and safety of new neuroendovascular devices.1 This model offers a simple and reliable platform for pre-clinical in vivo investigations, crucial for comprehending the biological processes underlying aneurysm healing after endovascular treatment.2 Notably, the induced aneurysm exhibits morphological, hemodynamic, and histological characteristics similar to human intracranial aneurysms. The creation of the aneurysm is performed using open and endovascular techniques. Each step of the procedure requires a meticulous and controlled gesture to ensure reproducibility of the aneurysm and minimize animal misuse. In video 1 we present a step-by-step procedural guide for aneurysm creation and follow-up. We hope this resource will help in promoting this model and provide useful guidance for researchers in the field. Video 1 Surgical procedure of creating elastase-induced aneurysms in rabbits.
How the elastase-induced rabbit aneurysm heals following flow diverter treatment: a histopathological study
Bilgin, Cem , Kallmes, David F. , Kadirvel, Ramanathan , Dai, Daying , Ding, Yonghong , Ghozy, Sherief , Mereuta, Oana Madalina

Journal of Neurosurgery | May 17, 2024 | Volume: 141 | Issue: 5 | Pages: 1262-1269

10.3171/2024.2.jns232262 Get It

OBJECTIVE Fibrin deposition is integral to thrombus formation and wound healing. The role of fibrin deposition and subsequent metabolism following flow diversion for aneurysm treatment remains poorly characterized. This study aimed to evaluate the role of fibrin in early thrombus organization after flow diverter treatment. METHODS Thirty-five elastase-induced aneurysms were induced in New Zealand white rabbits and subjected to endoluminal flow diversion treatment. The device-bearing arteries were harvested at 1, 3, and 6 months postimplantation and processed for histopathological examination, including a modified picro-Mallory stain (Carstairs method) to visualize fibrin and platelets, immunohistochemical targeting of smooth muscle actin (SMA), and H&E staining for conventional morphological evaluation. Quantitative analysis of tissue components was carried out using the Orbit Image Analysis software. The samples were also assessed qualitatively to investigate the morphology and location of fibrin and other thrombus components within the intra-aneurysmal thrombi. Statistical analyses were conducted using R software version 4.3.1. RESULTS Fibrin constituted 27.9% of the thrombus tissue within the aneurysm sac for aneurysms harvested at 1 month, and this rate was significantly lower in the 3-month group (10.2%, p = 0.018). The proportion of blood cells within the sac was also notably higher in the 1-month group compared with other time points. The primary tissue filling the dome at 1 month (14/15, 93%) was an unorganized thrombus primarily composed of fibrin, platelets, and red blood cells. Conversely, aneurysms harvested at 1 month had the lowest collagen level (25.6%). However, collagen became the dominant tissue component within the aneurysm sac, accounting for 71.8% of tissue in the 3-month group (p = 0.007). There were no differences observed among the examined components between the 3-month and 6-month groups. On qualitative analysis, collagen-producing SMA-positive myofibroblasts were located near or in between fibrin molecules. Healed aneurysms exhibited myofibroblasts, collagen, and a well-organized fibrin network on the aneurysm neck. In contrast, unhealed aneurysms displayed a poorly organized fibrin network with scattered myofibroblasts at the neck area. CONCLUSIONS These findings indicate that fibrin plays a foundational role in the gradual occlusion of aneurysms after flow diverter treatment. Endovascular approaches that enhance fibrin accumulation could potentially improve aneurysm occlusion rates. Further research is needed to establish the precise role of fibrin in aneurysm occlusion.